Search NASA⌕ Search

SEARCH · Search NASA

Results for “side load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Development of Multi-Filament Textured-Powder Bi-2212/Ag Wire with Enhanced Local Area Ratio (Final Technical Report)

ATC has successfully developed a new method for making high-performance Bi-2212/Ag su-perconducting wire with a favorable local area ratio (LAR)=Ag:Bi-2212. The method begins by texturing a fine powder of Bi-2212: the powder is loaded uniformly into an open-sided silver foil channel, the flaps of foil are folded over the powder filling, and the package is hydraulically com-pressed in a die set to form a textured-powder (TP) bar. XRD analysis of the interior powder in a compressed bar shows a texture of 80% after 200 MPa compression.

36 MATERIALS SCIENCE↗

South Africa: Framework for Energy Efficiency Demand Side Management

In July 2022, President Cyril Ramaphosa announced an emergency response plan to address the growing electricity crisis in South Africa, which included the necessity for customers of Eskom, South Africa’s primary electricity supplier, to implement demand-side energy efficiency measures. This report is the second of two reports that provides the foundation for a strategic Demand-Side Management (DSM) approach to reduce load shedding and maximize energy savings in South Africa, though inter-governmental collaboration and increased coordination of energy efficiency activities. The first report focuses on the experience of Eskom’s rate-funded Integrated Demand Management (IDM) programme, from its beginning in 2004 to today, highlighting the factors that led to failed support for the programme. This second report focuses on addressing the challenges identified in the first report and describes the elements of a policy framework to develop a sustained DSM program to meet the government’s energy efficiency goals in terms of greenhouse gas emissions reduction and social equity and inclusion to achieve a just transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

South Africa: Energy Efficiency Demand Side Management Experience (2004-2022)

In July 2022, President Cyril Ramaphosa announced an emergency response plan to address the growing electricity crisis in South Africa, which included the necessity for customers of Eskom, South Africa’s primary electricity supplier, to implement demand-side energy efficiency measures. This report is the first of two reports that provides the foundation for a strategic Demand-Side Management (DSM) approach to reduce load shedding and maximize energy savings in South Africa, through inter-governmental collaboration and increased coordination of energy efficiency activities. This first report focuses on the experience of Eskom’s rate-funded Integrated Demand Management (IDM) programme, from its beginning in 2004 to today, highlighting the factors that led to failed support for the programme, and emphasizing the measures that will need to be addressed to meet the government’s energy efficiency (EE) goals, as well as other socio-economic and environmental priorities, such as job creation, affordability and greenhouse gas (GHG) emission reduction goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Status Update for the Bearing Test Article Design Development – FY2025

Argonne National Laboratory’s (ANL) Mechanism Engineering Test Loop (METL) team has completed the design of a new Bearing Test Article (BTA) to test mechanical bearings for sodium fast reactor (SFR) mechanism applications. Recognition of the need for further bearing testing arose due to failure of rolling element bearings during testing of components for in-vessel fuel handling machines (FHMs) conducted at ANL in the METL facility. While the initial concept of the BTA arose from a need for bearing testing for FHM applications, the BTA design is configurable to test bearings of various sizes, types, and materials submerged in liquid sodium. Requirements for loading, shaft speed, temperature, and bearing size range were chosen based on requirements for SFR fuel handling. Modular components in the test bearing housings and shaft sleeves allow the design to accommodate a wide range of bearing sizes without modification to the larger assembly. Loading will be applied with screw jacks on the air side of the test article that will be adjusted to apply radial, thrust, or combined loading conditions. Applied force will be measured by load cells in-line with the loading mechanisms. In FY25 we have completed the design of the test article that will be fabricated and undergo testing at the METL facility. Drawing packages for the fabrication of the test article have been drafted and are being reviewed to add part tolerances and we have started ordering off-the-shelf components. The report will summarize the development of the Bearing Test Article design starting with an overview of the entire test article, then a more detailed examination of the bearing test section, loading mechanisms, test article ports and seals, and support structures, including analysis that went into significant design choices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Shuttle active thermal control system development testing. Volume 2: Modular radiator system tests

Tests were designed to investigate the validity of the "modular" approach to space radiator system design for space shuttle and future applications by gathering performance data on various systems comprised of different numbers of identical panels, subject to nominal and extreme heat loads and environments. Both one-sided and two-sided radiation was tested, and engineering data was gathered on simulated low a/e coatings and system response to changes in outlet temperature control point. The results of the testing showed system stability throughout nominal orbital transients, unrealistically skewed environments, freeze-thaw transients, and rapid changes in outlet temperature control point. Various alternative panel plumbing arrangements were tested with no significant changes in performance being observed. With the MRS panels arranged to represent the shuttle baseline system, a maximum heat rejection of 76,600 Btu/hr was obtained in segmented tests under the expected worst case design environments. Testing of an alternate smaller two-sided radiation configuration yielded a maximum heat rejection of 52,931 Btu/hr under the maximum design environments.

Scheps, P. B.↗

The magma budget of Volcan Arenal, Costa Rica from 1968 to 1980

The magma volume emitted by Volcan Arenal, Costa Rica, has been calculated to be 304 x 10 to the 6th cu m. A near-continuous rise from very deep within the crust is proposed as an explanation for Arenal's magma supply, and the long-term seismic pattern is interpreted as individual batches of magma using previously fractured pathways. During a break in activity (1973) the effusion site moved from Crater A to Crater C, approximately 400 m higher. It is maintained that the steady downward tilting of the volcano's summit was caused by the loading of the volcano's western side by about 19 x 10 to the 6th cu m of lava. Also noted is the abrupt decrease in effusion rate compatible with the increased magmatic head needed to reach Crater C. It is concluded that the constancy of magma composition and effusion rate from 1974 to 1980 indicates a homogeneous magma reservoir.

Wadge, G.↗

Vibroacoustic Characterization of a New Hybrid Wing-Body Fuselage Concept

A lighter, more robust airframe design is required to withstand the loading inherent to next generation non cylindrical commercial airliners. The Pultruded Rod Stitched Efficient Unitized Structure concept, a highly integrated composite design involving a stitched and co-cured substructure, has been developed to meet such requirements. While this structure has been shown to meet the demanding out-of-plane loading requirements of the flat-sided pressurized cabin design, there are concerns that the stiff co-cured details will result in relatively high acoustic radiation efficiencies at frequencies well below the thin skin acoustic coincidence frequency. To address this concern and establish a set of baseline vibroacoustic characteristics, a representative test panel was fabricated and a suite of tests were conducted that involved measurements of panel vibration and radiated sound power during point force and diffuse acoustic field excitations. Experimental results are shown and compared with Finite Element and Statistical Energy Analysis model predictions through the use of modal and energy correlation techniques among others. The behavior of the structure subject to turbulent boundary layer excitation is also numerically examined.

Allen, Albert R.↗

The peptide-receptive transition state of MHC-1 molecules: Insight from structure and molecular dynamics

MHC class I (MHC-I) proteins of the adaptive immune system require antigenic peptides for maintenance of mature conformation and immune function via specific recognition by MHC-I-restricted CD8(+) T lymphocytes. New MHC-I molecules in the endoplasmic reticulum are held by chaperones in a peptide-receptive (PR) transition state pending release by tightly binding peptides. In this study, we show, by crystallographic, docking, and molecular dynamics methods, dramatic movement of a hinged unit containing a conserved 3(10) helix that flips from an exposed 'open' position in the PR transition state to a 'closed' position with buried hydrophobic side chains in the peptide-loaded mature molecule. Crystallography of hinged unit residues 46-53 of murine H-2L(d) MHC-I H chain, complexed with mAb 64-3-7, demonstrates solvent exposure of these residues in the PR conformation. Docking and molecular dynamics predict how this segment moves to help form the A and B pockets crucial for the tight peptide binding needed for stability of the mature peptide-loaded conformation, chaperone dissociation, and Ag presentation.

59 BASIC BIOLOGICAL SCIENCES↗

Demand Response Potential from the Bulk Grid Perspective

Gain insight from an exploration of the potential value of demand response (DR) in future power systems. Using hourly DR resource estimates by sub-sector, electrical end-use, and grid service, we incorporate virtual generator models of DR resources into large-scale production cost models, and analyze the grid-level impacts in terms of the ability of DR to reduce system costs and potentially help integrate renewables or reduce system emissions. Additionally, we examine the value of DR, its revenue, and how these change under different system conditions. In this panel session, we will describe our input data and modeling methods, provide an overview of the production cost models used, and summarize key results from analyses in Florida and the western United States. Findings include variations in DR value by end-use and geography, an ability to increase economic PV deployment potential in high penetration systems, and mixed emissions outcomes depending on system composition and fuel prices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Smart Microgrids for the Developing World with Probabilistic Supply and Demand Inputs

Developing world microgrids often balance insufficient supply with growing, unpredictable demand. Deterministic and probabilistic simulators exist to model these microgrids, and each focuses on different technical aspects. With the addition of smart meters into microgrids, monitoring and control is now available at high granularity, which enriches microgrid planning and operation. This research is designing a new simulator to model smart microgrids with discrete probability distributions as supply and demand inputs. In our model, smart meters allow real-time power clipping for demand side management, effectively smoothing the system load curve as needed. To compare clipping schemes for grid operation and generation mixes for planning, we aggregate inputs by convolution then compute expected energy sold and probability of avoiding power cuts. The simulator plots these values for different combinations of power clipping threshold and number of customers clipped.

13 HYDRO ENERGY↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Determining and Unlocking Untapped Demand-Side Management Potential in South Africa: Demand Response at the Grid Edge

The National Renewable Energy Laboratory (NREL), funded through the Climate Technology and Change Network (CTCN), has provided technical assistance to key energy sector entities in South Africa to examine untapped demand-side management potential. NREL partnered with the Council for Scientific and Industrial Research (CSIR) and included key South Africa stakeholders: Eskom, the South African National Energy Development Institute (SANEDI), and the Department of Mineral and Resources and Energy (DMRE), including the CTCN National Designated Entity (NDE), the Department of Science and Innovation (DSI). South Africa is currently experiencing an energy crisis with extensive load shedding. While the load shedding crisis in South Africa is a supply side problem, demand-side management provides opportunities to achieve energy efficiency and to reduce peak demand. DSM also has huge potential to help alleviate load shedding, which is a last resort form of DSM.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Requirements for Auxiliary Stiffeners Attached to Panels Under Combined Compression and Shear

Panels of aluminum alloy sheets, framed by side and end stiffeners, were subjected to combined loading by means of offset knife edges applying loads to top and bottom end plates with reacting forces against the end plates supplied by laterally acting rollers. The test specimens were 17S-T aluminum alloy shoots 0.040 inch thick in panels of 10-inch width and three different lengths (approximately 10, 26, and 30 inch). Data were obtained for the bowing of transverse and longitudinal ribs of rectangular cross section and varying depths mounted on one side of the sheet only, for several ratios of compression to shear loads. Limiting values of the moments of inertia were calculated from these measurements. The experimental values exceed the theoretical values given by Timoshenko for the case of simply supported sheets with uniformly distributed boundary stresses. The work reported includes measurements of the effective shear moduli of the nine test panels with and without ribs. These data are compared with values published by Lahdo and Wagner.

ALUMINUM ALLOYS, SHEET - ALCOA 17ST - STRENGTH↗

Space Shuttle Orbiter Atlantis Liquid Oxygen Pre-Valve Detent Roller Cracking Investigation

During routine inspections of the Space Shuttle s Main Propulsion System Liquid Oxygen (LO2) pre-valve, the mechanism provided to maintain the valve in the open position was found cracked. The mechanism is a Vespel roller held against the valve visor by a stack of Belleville springs. The roller has been found cracked 3 times. All three instances were in the same valve in the same location. There are 6 pre-valves on each orbiter, and only one has exhibited this problem. Every-flight inspections were instituted and the rollers were found to be cracked after only one flight. Engineers at Marshall Space Flight Center, Johnson Space Center, and Kennedy Space Center worked together to determine a solution. There were several possible contributors to the failure: a misaligned visor, an out-of-specification edge with a sharp radius, an out-of-specification tolerance stack up of a Belleville spring stack that caused un-predicted loads on the Vespel SP-21 roller, and a dimple machined into the side of the roller to indicate LO2 compatibility that created a stress riser. The detent assembly was removed and replaced with parts that were on the low side of the tolerance stack up to eliminate the potential for high loads on the detent roller. After one flight, the roller was inspected and showed fewer signs of wear and no cracks.

Holleman, Elizabeth↗

Space Shuttle Orbiter Atlantis Liquid Oxygen Prevalve Detent Roller Cracking Investigation

During routine inspections of the Space Shuttle's Main Propulsion System (MPS) Liquid Oxygen (LO2) pre-valve, the mechanism provided to maintain the valve in the open position was found cracked. The mechanism is a Vespel roller held against the valve visor by a stack of Belleville springs. The roller has been found cracked 3 times. All three instances were in the same valve in the same location. There are 6 pre-valves on each orbiter, and only one has exhibited this problem. Every-flight inspections were instituted and the rollers were found to be cracked after only one flight. Engineers at Marshall Space Flight Center, Johnson Space Center and Kennedy Space Center worked together to determine a solution. There were several possible contributors to the failure: a mis-aligned visor, an out of specification edge with a sharp radius, an out of specification tolerance stack up of a Belleville spring stack that caused un-predicted loads on the Vespel SP-21 roller, and a dimple machined into the side of the roller to indicate LO2 compatibility that created a stress riser. The detent assembly was removed and replaced with parts that were on the low-side of the tolerance stack up to eliminate the potential for high loads on the detent roller. After one flight, the roller was inspected and showed fewer signs of wear and no cracks.

Holleman, Elizabeth↗

SunDial – An Integrated SHINES System to Enable High-penetration Feeder-level PV

The Project Team of Fraunhofer USA, National Grid, and IPKeys developed and conducted a pilot deployment of the SunDial system, a virtual power plant platform that enables high-penetrations of solar PV to be integrated into the distribution grid. The pilot was conducted over a 15-month period from August 2018 through October 2019 on a National Grid distribution feeder in Shirley, MA. A vendor-agnostic control platform (the “Global Scheduler”) optimally shaped the net load for a virtual portfolio of non-co-located DERs based on user-defined policy objectives. The goal of the SunDial project was to simplify and reduce the risk associated with the deployment of solar in high-penetration environments by: (1) Developing an open-source, vendor-agnostic dispatch platform that can be readily adapted to optimize control of DERs over a variety of use cases; (2) Developing auto-calibrating load and solar prediction methodologies that can be readily implemented and scaled to new deployments; (3) Developing a methodology to use demand-side management with traditional electrochemical energy storage to provide “load shaping” services in high solar penetration environments; (4) Using grid-scale storage to minimize short-term intermittency association with PV production; and (5) Deploying on the National Grid distribution system to gain experience on the potential for (and limits of) integrated storage with demand-side management.

14 SOLAR ENERGY↗

Visualization and Analytics of Distribution Systems with Deep Penetration of Distributed Energy Resources (VADER)

In its current state, the distribution system is incapable of handling small to moderate amounts of photovoltaic (PV) penetration. This is because it was initially designed for handling passive loads which, at the level of a substation, have low variability and are forecastable with high accuracy. It has been an open loop system with little monitoring and control. With the addition of PV energy sources, the overall scenario will change dramatically due to (1) two way power flow on network; and (2) high aggregate variability. Additionally, changes on the consumption side lead to a number of smart loads, Electric Vehicles (EVs), and Demand Response. These fundamental changes in the characteristics of the generation and consumption of power will lead to a number of practical engineering problems which must be overcome to allow increased penetration of Distributed PV. Solving the unique engineering challenges which arise at moderate levels of PV penetration requires closed loop integration of data from (1) PV sources; (2) customer load data from smart meters; (3) EV charging data; and (4) local and line mounted precision instruments. These data are not traditionally used by utilities in operations since they are ”non-SCADA” and the current grid does not require such levels of control. To integrate this data and provide real time intelligence from these non-SCADA data, we created the Visualization and Analytics of Distribution Systems with Deep Penetration of Distributed Energy Resources (VADER) platform. VADER is a collection of analytics enabled by integration of massive and heterogeneous data streams for granular real-time monitoring, visualization and control of Distributed Energy Resources (DER) in distribution networks. VADER analytics enable utilities to have greater visibility into distributed energy resources. We built several batch- and stream-analytics in VADER which help operators better understand the impact of distributed energy resources on the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗