Search NASA⌕ Search

SEARCH · Search NASA

Results for “single photon source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Gain Stability of Hamamatsu R5912-MOD Photo-Multipliers at Low Temperature

The Photon Detection System is a crucial component of the ICARUS detector in the Short Baseline Neutrino (SBN) Program at Fermi National Accelerator Laboratory (FNAL). It consists of 360 Photo Multiplier Tubes (PMTs) 8” Hamamatsu R5912-MOD and, since June 2020, it has been operated at the liquid Argon cryogenic temperature. During these years, the PMTs have shown gain losses as an aging effect. Using a climatic chamber at the INFN Sezione di Catania, we confirmed a stable gain for a single PMT 8” Hamamatsu 5912-MOD when operated at room temperature, and a persistent gain loss at temperatures around -70°C, although far from the liquid Argon one. No gain recovery was obtained bringing the PMT back to room temperature. We suspect that dynode deterioration due to temperature gradient plays a significant role in this phenomenon. During our test, the PMT was illuminated by a 520 nm laser source and operated in current mode. The laser beam was split into two optical fibers, the first one transmitting light through Neutral Density filters and then diffusing it over the surface of the PMT photocathode. The other optical fiber was used for an independent reference measurement of the injected light via a bolometric photodetector. In this presentation, the main technical characteristics of the measurement system are shown together with preliminary results which need further investigation to elucidate the underlying mechanisms driving the gain loss and to propose new mitigation strategies.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Forbidden scalar dark matter and dark Higgses

As experimental searches for WIMP dark matter continue to yield null results, models beyond the WIMP paradigm have proliferated in order to elude ever improving observational constraints, among them that of sub-GeV dark matter mediated by a massive vector portal (a dark photon) associated with a new dark U(1) gauge symmetry. It has been previously noted that for a significant range of the parameter space of this class of models, the annihilation of dark matter particles into a pair of dark photons can dominate the freeze-out process even when this process is kinematically forbidden for dark matter at rest — this is known as the “forbidden dark matter” (FDM) regime. Prior studies of this regime, however, assume that any “dark Higgs” associated with breaking the dark U(1) and imparting mass to the dark photon is decoupled from the dark matter and as such plays no role in the freeze-out process. In this paper, we explore the effects of a dark Higgs on sub-GeV dark matter phenomenology in this FDM regime by considering the simplest possible construction in which there exist non-trivial dark matter-dark Higgs couplings: a model with a single complex scalar DM candidate coupled directly to the dark Higgs field. We find that for a wide range of parameter space, the dark Higgs can alter the resulting relic abundance by many orders of magnitude, and that this effect can remain significant even for a small dark matter-dark Higgs coupling constant. Considering measurements from direct detection and measurements of the CMB, we further find that points in this model’s parameter space which recreate the appropriate dark matter relic abundance suffer only mild constraints from other sources at present, but may become accessible in near-future direct detection experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray wavefront sensor development at the Advanced Light Source

At Lawrence Berkeley National Laboratory's Advanced Light Source, we are developing x-ray wavefront sensors to support the creation and operation of beamlines with diffraction-limited quality. Our new approach to rapid, intermittent wavefront sensing operates in reflection at glancing incidence angles and is compatible with the high-power densities of modern beamlines. For soft x-ray applications especially, the wavefront sensor can operate upstream of the exit slit in a vertically dispersed beam. This single-shot technique supports lateral shearing interferometry and Hartmann wavefront sensing; it can be adapted to speckle-based techniques as well. The reflected beam is directed to an off-axis YAG crystal that produces scintillated visible light. A small mirror reflects the light to a microscope and camera, and the measured wavefront shape information can be used as feedback to adaptive x-ray mirror elements. A compact array of gratings enables measurement across a broad range of photon energies or wavefront curvatures. We describe recent demonstrations at soft x-ray and hard x-ray wavelengths measuring an adaptive x-ray mirror, and a toroidal focusing mirror.

Goldberg, Kenneth A↗

Quadratic strong coupling in AlN Kerr cavity solitons

Photonic platforms with χ (2) nonlinearity offer new degrees of freedom for Kerr frequency comb development. Here, we demonstrate Kerr soliton generation at 1550 nm with phase-matched quadratic coupling to the 775 nm harmonic band in a single AlN microring and thus the formation of dual-band mode-locked combs. In the strong quadratic coupling regime where the χ (2) phase-matching window overlaps the pump mode, the pump-to-harmonic-comb conversion efficiency is optimized. However, the strong quadratic coupling also drastically modifies the Kerr comb generation dynamics and decreases the probability of soliton generation. By engineering the χ (2) phase-matching wavelength, we are able to achieve a balance between high conversion efficiency and high soliton formation rate under the available pump power and microring quality factors. Our numerical simulations confirm the experimental observations. These findings provide guidance on tailoring single-cavity dual-band coherent comb sources.

Gong, Zheng (ORCID:0000000301704870)↗

Sensitivity analysis towards trace-uranium detection with γ-γ coincidence NAA

An improved approach for detection of trace amounts of 238 U by means of neutron activation analysis (NAA) is presented. The analysis enhancement is obtained by utilizing γ-γ coincidence counting. An empirical method for evaluating the sensitivity gain in the presence of a large source-related background is presented. A comparison of detection limits is made between two counting schemes; namely, counting single gammas using one HPGe detector versus counting coincident gammas using two HPGe detectors placed face-to-face. Furthermore, a data-validated radiation transport model, created in GEANT4 for a single HPGe detector, is extended to handle the two detector setup. In this counting scheme, a 238 U-detection sensitivity enhancement of about a factor of 8 is predicted for a sample of Saint-Gobain G3 Sapphire when compared to the simpler singles counting approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-silicon quantum light source by embedding an atomic emissive center in a nanophotonic cavity

Silicon is the most scalable optoelectronic material but has suffered from its inability to generate directly and efficiently classical or quantum light on-chip. Scaling and integration are the most fundamental challenges facing quantum science and technology. We report an all-silicon quantum light source based on a single atomic emissive center embedded in a silicon-based nanophotonic cavity. We observe a more than 30-fold enhancement of luminescence, a near-unity atom-cavity coupling efficiency, and an 8-fold acceleration of the emission from the all-silicon quantum emissive center. Our work opens immediate avenues for large-scale integrated cavity quantum electrodynamics and quantum light-matter interfaces with applications in quantum communication and networking, sensing, imaging, and computing.

36 MATERIALS SCIENCE↗

SQuaD: Smart Quantum Detection for Photon Recognition and Dark Count Elimination

Quantum detectors of single photons are an essential component for quantum information processing across computing, communication and networking. Today's quantum detection system, which consists of single photon detectors, timing electronics, control and data processing software, is primarily used for counting the number of single photon detection events. However, it is largely incapable of extracting other rich physical characteristics of the detected photons, such as their wavelengths, polarization states, photon numbers, or temporal waveforms. This work, for the first time, demonstrates a smart quantum detection system, SQuaD, which integrates a field programmable gate array (FPGA) with a neural network model, and is designed to recognize the features of photons and to eliminate detector dark-count. The SQuaD is a fully integrated quantum system with high timing-resolution data acquisition, onboard multi-scale data analysis, intelligent feature recognition and extraction, and feedback-driven system control. Our \name experimentally demonstrates 1) reliable photon counting on par with the state-of-the art commercial systems; 2) high-throughput data processing for each individual detection events; 3) efficient dark count recognition and elimination; 4) up to 100% accurate feature recognition of photon wavelength and polarization. Additionally, we deploy the SQuaD to an atomic (erbium ion) photon emitter source to realize noise-free control and readout of a spin qubit in the telecom band, enabling critical advances in quantum networks and distributed quantum information processing.

Linne, Karl C. [U. Chicago (main)] (ORCID:00090009↗

Phonon-mediated temperature dependence of Er 3+ optical transitions in Er 2 O 3

Characterization of the atomic level processes that determine optical transitions in emerging materials is critical to the development of new platforms for classical and quantum networking. Such understanding often emerges from studies of the temperature dependence of the transitions. We report measurements of the temperature dependent Er 3+ photoluminescence in single crystal Er 2 O 3 thin films epitaxially grown on Si(111) focused on transitions that involve the closely spaced Stark-split levels. Radiative intensities are compared to a model that includes relevant Stark-split states, single phonon-assisted excitations, and the well-established level population redistribution due to thermalization. This approach, applied to the individual Stark-split states and employing Er 2 O 3 specific single-phonon-assisted excitations, gives good agreement with experiment. This model allows us to demonstrate the difference in the electron-phonon coupling of the 4 S 3/2 and 2 H 11/2 states of Er 3+ in E 2 O 3 and suggests that the temperature dependence of Er 3+ emission intensity may vary significantly with small shifts in the wavelength (~0.1 nm) of the excitation source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser, vacuum and gas reaction chamber for operando measurements at NSLS-II's 28-ID-2

We present a laser reaction chamber that we have developed for in situ/operando X-ray diffraction measurements at the NSLS-II 28-ID-2 X-ray powder diffraction beamline. This chamber allows for rapid and dynamic sample heating under specialized gas environments, spanning ambient conditions down to vacuum pressures. We demonstrate the capabilities of this setup through two applications: laser-driven heating in polycrystalline iron oxide and in single-crystal WTe 2 . Our measurements reveal the ability to resolve chemical reaction kinetics over minutes with 1 s time resolution. This setup advances opportunities for in situ/operando X-ray diffraction studies of both bulk and single-crystal materials.

36 MATERIALS SCIENCE↗

VERITAS Discovery of Very High Energy Gamma-Ray Emission from S3 1227+25 and Multiwavelength Observations

We report the detection of very high energy gamma-ray emission from the blazar S3 1227+25 (VER J1230+253) with the Very Energetic Radiation Imaging Telescope Array System (VERITAS). VERITAS observations of the source were triggered by the detection of a hard-spectrum GeV flare on 2015 May 15 with the Fermi-Large Area Telescope (LAT). A combined 5 hr VERITAS exposure on May 16 and 18 resulted in a strong 13σ detection with a differential photon spectral index, Γ = 3.8 ± 0.4, and a flux level at 9% of the Crab Nebula above 120 GeV. This also triggered target-of-opportunity observations with Swift, optical photometry, polarimetry, and radio measurements, also presented in this work, in addition to the VERITAS and Fermi-LAT data. A temporal analysis of the gamma-ray flux during this period finds evidence of a shortest variability timescale of τ obs = 6.2 ± 0.9 hr, indicating emission from compact regions within the jet, and the combined gamma-ray spectrum shows no strong evidence of a spectral cutoff. An investigation into correlations between the multiwavelength observations found evidence of optical and gamma-ray correlations, suggesting a single-zone model of emission. Finally, the multiwavelength spectral energy distribution is well described by a simple one-zone leptonic synchrotron self-Compton radiation model.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamically controlled random lasing with colloidal titanium carbide MXene

Control of lasing properties through tailorable and dynamically tunable materials and reconfigurable compositions can augment the performance of random lasers for a wide range of applications. Here, a colloid of randomly dispersed weakly scattering single-layer titanium carbide (Ti 3 C 2 T x ) MXene flakes embedded within rhodamine 101 gain medium is experimentally shown to provide feedback for random lasing. Additionally, in contrast to previously reported random laser systems where the optical properties of scatterers are static, the relative permittivity of Ti 3 C 2 T x MXene flakes can be varied under optical pumping due to the saturable absorption properties. Numerical simulations indicate that the observed nonlinear response of Ti 3 C 2 T x MXene flakes enables dynamically tunable random lasing. Thus, pumping the Ti 3 C 2 T x MXene flakes with a second optical source decreases the gain threshold required to obtain random lasing. Also, using numerical simulations, it is shown that the control over the intensity of the second pump enables tuning the field distribution of the random lasing modes. Considering the diversity of the MXenes family, the proposed MXene colloidal metamaterial design opens up a new avenue to advanced control of lasing properties for photonic applications.

36 MATERIALS SCIENCE↗

Sub-threshold ultrafast one-photon photoemission from a Cu(111) photocathode

Single-photon photoemission of electrons for incident photon energies below the surface work function is reported for a single-crystal Cu(111) photocathode. Spectral characterization of the quantum efficiency and mean transverse energy of the emitted electrons is shown to be consistent with emission from a thermalized hot electron distribution photoexcited on sub-picosecond time scales into an upper conduction band at the L-point of the Brillouin zone of copper. To our knowledge, this is the first time that such excited-state thermionic emission has been observed from a planar metal photocathode, and then from a commonly used photocathode material. The results, therefore, indicate the potential importance of such band structure dependent sub-threshold photoemission mechanisms on the performance of photocathodes employed for the generation of short electron pulses using sub-picosecond laser pulses. Consequently, the combined experimental and theoretical work presented in this paper contributes to solid-state photocathode-based research aimed at our understanding and selection (or discovery) of high brightness photo-electron sources required for many electron-based diffraction, imaging, and accelerator applications.

43 PARTICLE ACCELERATORS↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Probing and Tuning Strain‐Localized Exciton Emission in 2D Material Bubbles at Room Temperature

In monolayer transition metal dichalcogenides bubbles-nanoscale deformations typically exhibiting a dome-like shape-Excitons are confined by the strain effect, which exhibits extraordinary emission properties, such as single photon generation, enhanced light emission, and spectrally tunable excitonic states. While the strain profiles of these bubbles are extensively studied, this work provides an approach 1) to directly visualize the associated exciton properties in bubbles formed in WSe2 monolayer, revealing an intrinsic emission wavelength shift of ≈40 nm, and 2) actively modify local strain, enabling further exciton emission tuning over a range of 50 nm. These are achieved by emission mapping and nanoindentation using a dielectric near-field probe, which enables the detection of local emission spectra and emission lifetimes within individual bubbles. Statistical analysis of 67 bubbles uncovers an emission wavelength distribution centered around 780 nm. Furthermore, saturation behavior in the power-dependent studies and the associated lifetime change reveal the localized nature of the strain-induced states. These findings provide direct insights into the strain-localized emission dynamics in bubbles and establish a robust framework for non-destructive, reversible, and predictable nanoscale emission control, presenting a potential avenue for developing next-generation tunable quantum optical sources.

2D materials bubbles↗

An extraction scheme for future CEBAF FFA based energy upgrade

Jefferson lab is considering an energy increase from current 12 GeV to 22 GeV for its CEBAF accelerator. This will be accomplished by recirculating 5-6 additional turns through two parallel CEBAF LINACs using an FFA arc at each end of the racetrack. The total recirculation turns would be 10 times, the first four turns use present conventional arcs to make the 180-degree bends from one LINAC to the other. However, the last 5-6 turns will all share a single beam line inside two FFA arcs. This reduces the footprint and the cost of the project significantly. On the other hand, having the trajectories of last 5-6 recirculating beams close to each other makes it challenging to extract beams from different passes with different energies. In this paper we will explain our present extraction system for 12 GeV, our challenges and limitations, and a possible extraction solution for the 22 GeV upgrade with the goal of extracting beam at different turns/energies to different experimental halls.

Accelerator Physics↗

Quantum vacuum processes in the extremely intense light of relativistic plasma mirror sources

Abstract The advent of petawatt-class laser systems allows generating electromagnetic fields of unprecedented strength in a controlled environment, driving increasingly more efforts to probe yet unobserved processes through their interaction with the quantum vacuum. Still, the lowest intensity scale governing these effects lies orders of magnitude beyond foreseen capabilities, so that such endeavor is expected to remain extremely challenging. In recent years, however, plasma mirrors have emerged as a promising bridge across this gap, by enabling the conversion of intense infrared laser pulses into coherently focused Doppler harmonic beams lying in the X-UV range. In this work, we present predictions on the quantum vacuum signatures produced when such beams are focused to intensities between 10 24 and 10 28 W cm −2 , specifically photon–photon scattering and electron–positron pair creation. These signatures are computed via the stimulated vacuum formalism, combined with a model of perfectly focused beam built from PIC-generated harmonics spectra, and implemented on state-of-the-art massively parallel numerical tools. In view of identifying experimentally favorable configurations, we also consider the coupling of the focused harmonic beam with an auxiliary optical beam, and provide comparison with other established schemes. Our results show that a single coherently focused harmonic beam can produce as much scattered photons as two infrared pulses in head-on collision, and confirm that the coupling of the harmonic beam to an auxiliary beam gives rise to significant levels of inelastic scattering, and hence holds the potential to strongly improve the attainable signal to noise ratios in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗