Search NASA⌕ Search

SEARCH · Search NASA

Results for “soft materials design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

All-organic self-separating three-dimensionally nanoarchitected electrochemical energy storage devices

This work realizes a three-dimensionally (3D) nanoarchitected, all organic, "self-separating" lithium-ion electrochemical energy storage (EES) device that is cycled as a solid-state full cell. The device is enabled by a monolithic carbon anode with a co-continuous pore network, derived from the structure direction of resols by an ultra-large molar mass block copolymer (BCP), poly(styrene-block-2-dimethylaminoethyl methacrylate) (SA). Electropolymerization of a single-phase conductive and redox-active material, poly((2,3-dihydrothieno[3,4-b][1,4]dioxin-2-yl)methyl 9,10-dioxo-9,10-dihydroanthracene-2-carboxylate) (PAQEDOT), into the pore space provides the cathode of the cell. The device is electronically contacted to the relevant electrode network enabled by the co-continuous nature of each electrode. Electrochemical processing via cycling against external lithium in an electrolyte generates a solid electrolyte interphase (SEI) as a separator and lithiates the cell electrodes, after which the EES device is cycled in the solid state. While the full cell does not demonstrate high cyclability, the best full cell demonstrates a discharge capacity of 267 milliamp hours per gram (mAh/g). This work marks, to the best of knowledge of the authors, the first example of an all-organic materials derived 3D nanoarchitected EES device, as well as the first design of "self-separating" cell fabrication. Furthermore, generalization of the design to another co-continuous carbon form factor is demonstrated.

FOS: Physical sciences↗

Ion transport through reconfigurable nanoparticle-surfactant stabilized droplet interface bilayers

Despite their adaptability and mechanical stability, Pickering emulsions based on the interfacial assembly of colloidal particles have not found use in iontronics, since the dense interfacial packing of micron-sized particles precludes functional connectivity between two droplets. In this work, we introduce a chemically reconfigurable droplet interface bilayer (DIB) platform based on the interfacial assembly of nanoparticle-surfactants (NPSs) that enables spontaneous or field-induced formation of ion-conducting nanochannels, eliminating the need of ionophores or nanochannel-forming proteins. These nanoscopic channels emerge from packing defects in the jammed interfacial assemblies of the charged NPSs and support size and charge selective, hysteretic ion transport governed by interfacial electrostatics and dimensional constraints. The NPS-DIBs show short-term and long-term plasticity, hallmarks of neuromorphic behavior, that are mediated by the structural and chemical design of the bilayer. These assemblies establish a versatile, chemically tunable platform that couples soft-matter mechanics with interfacial ionic functionality, offering a robust foundation for soft iontronic systems.

36 MATERIALS SCIENCE↗

Aberration corrected RF flipper for high resolution neutron spectroscopy

Project Summary Company: Adelphi Technology, Inc. Title: Aberration-corrected High Frequency RF Flipper for High-Resolution Neutron Spectroscopy PI: Dr. Jay Theodore Cremer Topic: C55-11 Enhancement of Scattering Instrumentation Technology Used at Pulsed and Continuous Sources Subtopic: d. Other Statement of the problem or situation that is being addressed. The quest to understand heterogeneous and hierarchical materials is gathering momentum, as described in a 2015 report by the Basic Energy Sciences Advisory Committee on Challenges at the Frontiers of Matter and Energy. For the past 40 years a technique called neutron spin echo (NSE) has been used to probe molecular motions in such non-crystalline materials over time scales from 10’s of picoseconds to 100’s of nanoseconds. The method has provided unique information about the dynamics of soft heterogeneous materials, including confirmation of the de Gennes model of polymer reptation and quantitative measurement of bending constants of biologically relevant lipid membranes. However, scientists continue to clamor for even higher resolution than NSE can provide. Biomaterials, polymers, glasses, and artificially nanostructured materials all manifest slow molecular motions because of weak or competing interactions between subunits and are amenable to study with neutrons, provided sufficiently long dynamical correlation times can be achieved. All these materials have important applications to advanced technologies so understanding them is key to technological progress. General statement of how this problem is being addressed. We will address the need for high-resolution neutron spectroscopy by using a technique called Neutron Resonance Spin Echo (NRSE). While similar to NSE in many respects, this method has the potential to exceed the NSE capabilities, if 2 technical hurdles can be overcome. The major impediments to successful high-resolution NRSE are the availability of two technologies: a very high frequency, efficient, radiofrequency (rf) flipper for neutrons and a method to correct certain magnetic aberrations. Based on previous STTR support and follow-on research we have developed a suitable rf flipper and we have invented a method to correct the magnetic aberrations. Both technologies need refinement to make them suitable for implementation at a neutron source such as the Oak Ridge National Laboratory nuclear reactor. In this proposal we seek to perfect the two technologies and to combine them into a single, operationally convenient device. Commercial Applications and Other Benefits In view of the increasing demand for the unique scientific information that high resolution neutron spectroscopy can provide, we expect several major instrumentation upgrades at both U.S. and foreign neutron centers will require make use of the NRSE method over the coming decade, creating a market for the devices we will design. These components will enhance scientists’ abilities to probe the time dependence of density fluctuations in a wide range of hierarchical and heterogeneous materials many of which are vital to existing and future technologies. Key Words – Polarized Neutrons, Neutron Spin Echo, Neutron Scattering, advanced materials. Summary for Members of Congress Neutron beams are a powerful materials-science probe that provide unique information about the structure of matter. The proposed devices will accelerate scientific discoveries required to achieve national goals for new technological materials.

36 MATERIALS SCIENCE↗

Soft interface instability and gas flow channeling in low-permeability deformable media

Understanding gas percolation through a clay layer or a shale formation is of great importance for the development of a geologic repository for nuclear waste disposal, a subsurface system for gas storage, and an engineering approach for hydrocarbon extraction from unconventional reservoirs. Gas injection experiments have revealed complex dynamic behaviours of gas percolation through water saturated compacted bentonite, characterized by a high breakthrough pressure, rapid breakthrough, a pressure/stress decay after the breakthrough, a relatively high migration rate, high-frequency periodic/nonperiodic variations in flow rate, stepwise rate reductions during relaxation, and low gas saturation over the whole process, all indicating channelling nature of the processes. Using linear stability analyses, we show that this channelling can autonomously emerge from the instability of the deformable interface between the injected gas and the compacted bentonite matrix driven by local stress concentration, pore dilation, and hydrologic gradient. Channel patterns formed would possess a fractal geometry. We further show that, once a percolating channel is established, the gas injected would percolate through the channel in a chain of gas bubbles, also due to the interface instability, resulting in periodic/chaotic variations in gas flow rate. Our work provides a unified explanation for key features observed for gas percolation in low-permeability deformable media. The work also suggests a possibility of designing an engineered barrier system for a nuclear waste repository that can have controllable gas release while limit water transport.

Bentonite↗

Hooks versus Pedicle Screws at the Upper Instrumented Level: An In Vitro Biomechanical Comparison

Study Design. Controlled laboratory study Objective. To compare motions at the upper instrumented vertebra (UIV) and supra-adjacent level (UIV+1) between two fixation techniques in thoracic posterior spinal fusion (PSF) constructs. We hypothesized there would be greater motion at UIV+1 after cyclic loading across all constructs and bilateral pedicle screws (BPS) with posterior ligamentous compromise would demonstrate the greatest UIV+1 range of motion (ROM). Summary of Background Data. Proximal junctional kyphosis (PJK) is a well-recognized complication following long thoraco-lumbar PSF, however its mechanism is poorly understood. Methods. Twenty-seven thoracic functional spine units (FSU) were randomly divided into three UIV fixation groups (n=9): (1) BPS, (2) bilateral transverse process hooks (TPH), and (3) BPS with compromise of the posterior elements between UIV and UIV+1 (BPS-C). Specimens were tested on a servohydraulic materials testing system in native state, following instrumentation, and after cyclic loading. FSUs were loaded in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Results. After cyclic testing, the TPH group had a mean 29.4% increase in FE ROM at UIV+1 versus 76.6% in the BPS group ( P <0.05). The BPS-C group showed an increased FE of 49.9% and 62.19% with sectioning of the facet joints and interspinous ligament respectively prior to cyclic testing. Conclusion. Bilateral pedicle screws at the UIV led to greater motion at UIV+1 compared to bilateral TPH after cyclic loading. This is likely due to the increased rigidity of BPS compared to TPH leading to a “softer” transition between the TPH construct and native anatomy at the supra-adjacent level. Facet capsule compromise led to a 49.9% increase in UIV+1 motion, underscoring the importance of preserving the posterior ligamentous complex. Clinical studies that account for fusion rates are warranted to determine if constructs with a “soft transition” result in less PJK in vivo.

Neurosciences & Neurology↗

Ion Pairing Mediates Molecular Organization Across Liquid/Liquid Interfaces

Liquid/liquid interfaces play a central role in scientific fields ranging from nanomaterial synthesis and soft matter electronics to nuclear waste remediation and chemical separations. This diversity of functions arises from an interface’s ability to respond to changing conditions in its neighboring bulk phases. Understanding what drives this interfacial flexibility can provide novel avenues for designing new functional interfaces. However, limiting this progress is an inadequate understanding of the subtle intermolecular and interphase interactions taking place at the molecular level. Here, we use surface-specific vibrational sum frequency generation spectroscopy combined with atomistic molecular dynamics simulations to investigate the self-assembly and structure of model ionic oligomers consisting of an oligodimethylsiloxane (ODMS) tail covalently attached to a positively charged methyl imidazolium (MIM + ) head group at buried oil/aqueous interfaces. We show how the presence of seemingly innocuous salts can impart dramatic changes to the ODMS tail conformations in the oil phase via specific ion effects and ion-pairing interactions taking place in the aqueous phase. These specific ion interactions are shown to drive enhanced amphiphile adsorption, induce morphological changes, and disrupt emergent hydrogen-bonding structures at the interface. Tuning these interactions allows for independent control over the oligomer structure in the oil phase versus interfacial population changes and represents key mechanistic insight that is needed to control chemical reactions at liquid/liquid interfaces.

36 MATERIALS SCIENCE↗

SANS quantification of bound water in water-soluble polymers across multiple concentration regimes

Contrast-variation small-angle neutron scattering (CV-SANS) is a widely used technique for quantifying hydration water in soft matter systems, but it is predominantly applied in the dilute regime or for systems with a well-defined structure factor. Here, CV-SANS was used to quantify the number of hydration water molecules associating with three water-soluble polymers with different critical solution temperatures and types of water–solute interactions in dilute, semidilute, and concentrated solution through the exploration of novel methods of data fitting and analysis. Multiple SANS fitting workflows with varying levels of model assumptions were evaluated and compared to give insight into SANS model selection. These fitting pathways ranged from general, model-free algorithms to more standard form and structure factor fitting. In addition, Monte Carlo bootstrapping was evaluated as a method to estimate parameter uncertainty through simulation of technical replicates. The most robust fitting workflow for dilute solutions was found to be form factor fitting without CV-SANS ( i.e. polymer in 100% D 2 O). For semidilute and concentrated solutions, while the model-free approach can be mathematically defined for CV-SANS data, the addition of a structure factor imposes physical constraints on the optimization problem, suggesting that the optimal fitting pathway should include appropriate form and structure factor models. The measured hydration numbers were consistent with the number of tightly bound water molecules associated with each monomer unit, and the concentration dependence of the hydration number was largely governed by the chemistry-specific interactions between water and polymer. Polymers with weaker water–polymer interactions ( i.e. those with fewer hydration water molecules) were found to have more bound water at higher concentrations than those with stronger water–polymer interactions due to the increase in the number of forced water–polymer contacts in the concentrated system. This SANS-based method to count hydration water molecules can be applied to polymers in any concentration regime, which will lead to improved understanding of water–polymer interactions and their impact on materials design.

36 MATERIALS SCIENCE↗

Superstructural phase transitions in polymer-grafted nanooctahedra

Superlattices of polyhedral nanocrystals exhibit emergent properties defined by their structural arrangements, but native nanocrystal ligands often limit their programmability. Polymeric ligands address this limitation by enabling tunable nanocrystal softness through modifications of polymer molecular weight and grafting density. Here, we investigate phase transitions in polymer-grafted nanooctahedra by varying polymer length, nanocrystal size, truncation, and ligand density. In two-dimensional superlattices, longer polymers or smaller nanooctahedra induce a transition from orientationally ordered to hexagonal rotator lattices. In three-dimensional superlattices, increasing polymer length drives transitions from Minkowski to body-centered cubic and plastic hexagonal close-packed phases, while higher grafting densities further enable transitions to simple hexagonal phases. Polymer brush and thermodynamic perturbation theories, supported by Monte Carlo simulations, uncover the entropic and enthalpic forces that govern these transitions. This work highlights the versatility of polymer-grafted anisotropic nanocrystals as building blocks for designing hierarchical superstructures and metamaterials with customizable properties.

36 MATERIALS SCIENCE↗

A New Experimental Station for Liquid Interface X-Ray Scattering At NSLS-II Beamline 12-ID

Open Platform and Liquids Scattering (OPLS) is a new experimental station recently built and currently being commissioned at the Soft Matter Interfaces (SMI) beamline 12-ID at NSLS-II. The new instrument expands SMI’s beamline scientific capabilities via the addition of X-ray scattering techniques from liquid surfaces and interfaces. The design of this new instrument, located inside the 12-ID beamline shielding enclosure (hutch B), is based on a single Ge (111) crystal deflector, which bounces the incident x-ray beam downward towards a liquid sample which must be maintained in a horizontal orientation (gravity-driven consideration). The OPLS instrument has a variable deflector-to-sample distance ranging from 0.6 m to 1.5 m. X-ray detectors are mounted on a 2-theta scattering arm located downstream of the sample location. The 2-theta arm is designed to hold up to three X-ray detectors, with fixed 2-theta angular offsets, each dedicated to a different X-ray technique such as X-ray reflectivity, grazing-incidence X-ray scattering, and small- and wide-angle X-ray scattering. Currently, the OPLS experimental station intercepts the SMI beam that otherwise propagates to the experimental endstation located in hutch C and can be retracted to a ’parking’ position laterally out of this beam to allow installation of a removable beam pipe that is needed to support operations in hutch C. The design of OPLS is flexible enough to quickly adapt to a planned future configuration of the SMI beamline in which a OPLS is illuminated separately from the main SMI branch via a second, canted undulator source and a separate photon delivery system. In this future configuration, both branches will be able to operate independently and simultaneously.

36 MATERIALS SCIENCE↗

Enhancing actuation control in monolithic liquid crystal elastomer films with dual heat and light responsiveness

This study presents a dual heat and light-responsive monolithic liquid crystal elastomers (LCEs) film designed to enhance actuation control. The LCE films were capable of various motion types, including curvature reversal, oscillation, and sustainable flipping. By incorporating an azobenzene compound, the films exhibited additional functionalities such as enhanced curvature reversal, accelerated oscillation, and the ability to lock continuous flipping motion upon light stimulation. Furthermore, by adjusting the aspect ratio (AR) of a single film, different thermal motion states were realized, demonstrating the flexibility of this approach. Observations using an NIR camera confirmed temperature fluctuations corresponding to thermal exchange, and the influence of UV light on motion regulation was quantitatively analyzed. In conclusion, the ability to regulate motion through dual stimuli paves the way for improved dynamic motion control and thermal management in advanced robotic applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ X-ray Scattering Reveals Coarsening Rates of Superlattices Self-Assembled from Electrostatically Stabilized Metal Nanocrystals Depend Nonmonotonically on Driving Force

Self-assembly of colloidal nanocrystals (NCs) into superlattices (SLs) is an appealing strategy to design hierarchically organized materials with promising functionalities. Mechanistic studies are still needed to uncover the design principles for SL self-assembly, but such studies have been difficult to perform due to the fast time and short length scales of NC systems. To address this challenge, we developed an apparatus to directly measure the evolving phases in situ and in real time of an electrostatically stabilized Au NC solution before, during, and after it is quenched to form SLs using small-angle X-ray scattering. By developing a quantitative model, we fit the time-dependent scattering patterns to obtain the phase diagram of the system and the kinetics of the colloidal and SL phases as a function of varying quench conditions. The extracted phase diagram is consistent with particles whose interactions are short in range relative to their diameter. We find the degree of SL order is primarily determined by fast (subsecond) initial nucleation and growth kinetics, while coarsening at later times depends nonmonotonically on the driving force for self-assembly. We validate these results by direct comparison with simulations and use them to suggest dynamic design principles to optimize the crystallinity within a finite time window. The combination of this measurement methodology, quantitative analysis, and simulation should be generalizable to elucidate and better control the microscopic self-assembly pathways of a wide range of bottom-up assembled systems and architectures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Distinguishing electronic contributions of surface and sub-surface transition metal atoms in Ti-based MXenes

MXenes are a rapidly-expanding family of 2D transition metal carbides and nitrides that have attracted attention due to their excellent performance in applications ranging from energy storage to electromagnetic interference shielding. Numerous other electronic and magnetic properties have been computationally predicted, but not yet realized due to the experimental difficulty in obtaining uniform surface terminations (T x ), necessitating new design approaches for MXenes that are independent of surface groups. In this study, we distinguished the contributions of surface and sub-surface Ti atoms to the electronic structure of four Ti-based MXenes (Ti 2 CT x , Ti 3 C 2 T x , Cr 2 TiC 2 T x , and Mo 2 TiC 2 T x ) using soft x-ray absorption spectroscopy, revealing minimal changes in the spectral features between the parent MAX phase and its MXene when no surface Ti atoms are present in the MXene, such as Mo 2 TiC 2 T x and Cr 2 TiC 2 T x . In contrast, for MXenes with surface Ti atoms, here Ti 3 C 2 T x and Ti 2 CT x , the Ti L-edge spectra are significantly modified compared to their parent MAX phase compounds. First principles calculations provide similar trends in the partial density of states derived from surface and interior Ti atoms, corroborating the spectroscopic measurements. Furthermore, these results reveal that electronic states derived from sub-surface M-site layers are largely unperturbed by the surface groups, indicating a relatively short length scale over which the T x groups alter the nominal electron count associated with Ti atoms and suggesting that desired band features should be hosted by sub-surface M-sites that are electronically more robust than their surface M-site counterparts.

36 MATERIALS SCIENCE↗

Thermal Scattering Law Data Development for Paraffin Wax

Paraffin wax is often used as a nuclear moderator to slow down the fast neutrons in experimental critical assemblies [1]. It is a colorless and soft solid material that consists primarily of straight-chain alkanes (n-alkanes), which are hydrocarbons with the general formula CnH2n+2 [2-3]. The length of the hydrocarbon chain ranges from C20 to C30 and higher [2]. It is distinguished by its solid state at room temperature and begins to melt above approximately 310 K [4]. Paraffin wax is a commonly employed substance in the manufacture of shielding. One of its noteworthy characteristics is its ability to effectively absorb the neutrons. Also, it possesses a high macroscopic cross section, which enables it to efficiently moderate neutrons. As a result, paraffin wax is extensively utilized in various applications where moderation and shielding of neutrons are needed. For simulations, it is necessary to evaluate its thermal scattering law (TSL) and cross sections. Computationally, classical molecular dynamics (CMD) simulations provide the capability of simulating atomic details. For example, several unary, binary, and few multi component mixtures have been investigated of the paraffin model by using molecular dynamics simulations [5-12]. An assessment of thermal neutron scattering in a heavy paraffinic oil treated both as a solid and a viscous fluid containing 25% linear branched paraffin (C30H62), 35% one ring cycloalkane (C30H60), 15% two rings cycloalkane (C30H58), and 25% aromatic (C30H60) chains has been studied using CMD simulations for producing TSL data [13]. Nevertheless, there is lack of TSL and cross section data for paraffin wax as most of the reported analyses focus on the unary and binary mixture of n-alkanes, which is not consistent with actual paraffin wax [2]. In this work, we applied the equilibrium CMD simulations technique to explore the structure and dynamical properties of wax, which are fundamental input to calculate the TSL. A paraffin wax system was modeled using the CMD code LAMMPS (Large-scale Atomic/Molecular Massively Parallel Simulator) [14-15] with the semi-empirical COMPASS [16] force field. The density of state (DOS) was calculated from the normalized velocity autocorrelation function (VACF), which is the Fourier transform of the normalized VACF. The DOS was used for the calculation of the TSL and thermal scattering cross sections. The paraffin wax atomic system was constructed by using the MedeA material design platform [17], and was benchmarked using available properties (i.e., density, bond lengths, angles, diffusivity, and viscosity).

Nuclear Criticality Safety Program (NCSP)↗

Measurement Uncertainty of Highly Asymmetrically Curved Elliptical Mirrors Using Multi-Pitch Slope Stitching Technique

Soft X-ray off-axis elliptical mirrors bring new challenges for X-ray mirror metrology. These highly asymmetrically curved elliptical cylindrical mirrors with a total slope range >10 mrad are extremely challenging to measure. Their total slope range exceeds the measuring range of most angular sensors used for X-ray mirror inspection. To overcome this problem, it is possible to stitch partial slope data by measuring the mirror at different pitch angles (multi-pitch angles). By revisiting the theory of the multi-pitch Nano-accuracy Surface Profiler (NSP), we derive the sampling position error on the mirror surface as a function of the mirror height profile and the measurement error of the pitch rotation center. When measuring “extreme”, highly asymmetrically curved, elliptical mirrors, the calculation of the mirror height profile with iterative reconstruction outperforms the classical “flat assumption” (i.e., assuming that the mirror sag is negligible). As demonstrated by our simulations, a proper tolerance evaluation on the measurement of pitch rotation center is needed to assess the measurement accuracy (systematic error) for these strongly aspherical mirrors using the multi-pitch NSP technique. Taking a real design of an “extreme” elliptical mirror as a case study, we conduct a Monte Carlo simulation to mimic the measurement and characterization process to analyze the impact of several error sources. With the measurement uncertainty of the pitch rotation center, the multi-pitch NSP measurement can estimate the grazing angle θ and the chief ray location x o with their uncertainties, as well as the slope residuals.

36 MATERIALS SCIENCE↗

A coded aperture microscope for X-ray fluorescence full-field imaging

The design and construction of an instrument for full-field imaging of the X-ray fluorescence emitted by a fully illuminated sample are presented. The aim is to produce an X-ray microscope with a few micrometers spatial resolution, which does not need to scan the sample. Since the fluorescence from a spatially inhomogeneous sample may contain many fluorescence lines, the optic which will provide the magnification of the emissions must be achromatic, i.e. its optical properties must be energy-independent. The only optics which fulfill this requirement in the X-ray regime are mirrors and pinholes. The throughput of a simple pinhole is very low, so the concept of coded apertures is an attractive extension which improves the throughput by having many pinholes, and retains the achromatic property. Modified uniformly redundant arrays (MURAs) with 10 µm openings and 50% open area have been fabricated using gold in a lithographic technique, fabricated on a 1 µm-thick silicon nitride membrane. The gold is 25 µm thick, offering good contrast up to 20 keV. The silicon nitride is transparent down into the soft X-ray region. MURAs with various orders, from 19 up to 73, as well as their respective negative (a mask where open and closed positions are inversed compared with the original mask), have been made. Having both signs of mask will reduce near-field artifacts and make it possible to correct for any lack of contrast.

36 MATERIALS SCIENCE↗

Nonlinear viscoelastic response of silicone additively manufactured direct ink write (DIW) foams under repetitive compression

To investigate dynamic fatigue behavior of foam in military protective applications, such as helmets, additively manufactured (AM) foams were compressively strained into the plateau region using a reduced design of experiments. A simple power law was found to govern the decline in dynamic stiffness (complex modulus) as the foams underwent the purchase order requirement of 10,000 cycles of small deformation in the plateau region. This rate of decline was newly found to correlate with the degree of nonlinearity in the material’s deformation, quantified using total harmonic distortion. Materials with low nonlinearity exhibited relatively stable stiffness across cycles, while those with high nonlinearity experienced greater losses. The observed nonlinearity depended on both applied stress and strain rate. A strong linear correlation (R 2 = 0.78) was identified between second-order nonlinearity and the time-dependent stiffness response. Two lattice structures were examined: face-centered tetragonal (FCT) and simple cubic (SC). The SC material exhibited higher total harmonic distortion (5%) and lower stiffness retention than the FCT (2%). In conclusion, these results suggest that for cyclic compression applications in a wide variety of industries such as packaging, personal protective equipment, or aerospace, selecting materials with lower stress and greater structural uniformity can enhance the stability of dynamic performance.

42 ENGINEERING↗

Anisotropic Motions of Fibrils Dictated by Their Orientations in the Lamella: A Coarse-Grained Model of a Plant Cell Wall

Plant cell walls are complex systems that exhibit the characteristics of both rigid and soft material depending on their external perturbations. The three main polymeric components in a plant primary cell wall are cellulose fibrils, hemicellulose, and pectins. These components interact in a hierarchical fashion giving rise to mesoscale structural features such as cellulose bundles, lamella stacking, and so on. Although several studies have focused on understanding these unique structural features, a clear picture linking them to cell wall mechanics is still lacking. As a first step toward this goal, a phenomenological model of plant cell wall has been developed in this work by using available experimental data to investigate the underlying connections between mesoscale structural features and the motions of fibrils during deformation. In this model cellulose fibrils exhibit motions such as angular reorientations and kinking upon forced stretching. Furthermore, these motions are dependent on the orientation of fibrils with respect to the stretch direction, i.e., fibrils that are at an angle to the stretch direction exhibit predominant angular reorientations, while fibrils transverse to the stretch direction undergo kinking as a result of transverse compression. Varying the chain length of pectin had negligible effects on these motions. One of the main contributions from this work is the development of a simple model that can be easily fine-tuned to test other hypotheses and extended to include additional experimental knowledge about the structural aspects of cell walls in the future.

36 MATERIALS SCIENCE↗

Silicon wafer fracture stress for tracking sensors in particle physics experiments

For the construction of the ATLAS Inner Tracker strip detector, silicon strip sensor modules are glued directly onto carbon fibre support structures using a soft silicone gel. During tests at temperatures below -35°C, several of the sensors were found to crack due to a mismatch in coefficients of thermal expansion between polyimide circuit boards with copper metal layers (glued onto the sensor) and the silicon sensor itself. While module assembly procedures were developed to minimise variations between modules, cold tests showed a wide range of temperatures at which supposedly comparable modules failed. The observed variance (fracture temperatures between -35°C and -70°C) for supposedly comparable modules suggests an undetected variation between modules suspected to be intrinsic to the silicon wafer itself. Therefore, a test programme was developed to investigate the fracture stress of representative sensor wafer cutoffs. This paper presents results for the fracture stress of silicon sensors used in detector modules.

Detector design and construction technologies and ↗