Search NASA⌕ Search

SEARCH · Search NASA

Results for “software based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

TU-G-BRD-02: Automated Systematic Quality Assurance Program for Radiation Oncology Information System Upgrades

Purpose: To: (1) describe an independent, automated, systematic software-based protocol for verifying clinical data accuracy/integrity for mitigation of data corruption/loss risks following radiation oncology information system (ROIS) upgrades; and (2) report on application of this approach in an academic/community practice environment. Methods: We propose a robust approach to perform quality assurance on the ROIS after an upgrade, targeting four data sources: (1) ROIS relational database; (2) ROIS DICOM interface; (3) ROIS treatment machine data configuration; and (4) ROIS-generated clinical reports. We investigated the database schema for differences between pre-/post-upgrade states. Paired DICOM data streams for the same object (such as RT-Plan/Treatment Record) were compared between pre-/post-upgrade states for data corruption. We examined machine configuration and related commissioning data files for changes and corruption. ROIS-generated treatment appointment and treatment parameter reports were compared to ensure patient encounter and treatment plan accuracy. This protocol was supplemented by an end-to-end clinical workflow test to verify essential ROI functionality and integrity of components interfaced during patient care chain of activities. We describe the implementation of this protocol during a Varian ARIA system upgrade at our clinic. Results: We verified 1,638 data tables with 2.4 billion data records. For 222 under-treatment patients, 605 DICOM RT plans and 13,480 DICOM treatment records retrieved from the ROIS DICOM interface were compared, with no differences in fractions, doses delivered, or treatment parameters. We identified 82 new data tables and 78 amended/deleted tables consistent with the upgrade. Reports for 5,073 patient encounters over a 2-week horizon were compared and were identical to those before the upgrade. Content in 12,237 xml machine files was compared, with no differences identified. Conclusion: An independent QA/validation approach for ROIS upgrades was developed and implemented at our clinic. The success of this approach ensures a robust QA of ROIS upgrades without manual paper/electronic checks and associated intensive labor.

60 APPLIED LIFE SCIENCES↗

SU-F-P-09: A Global Medical Physics Collaboration for Implementation of Modern Radiotherapy in Botswana

Purpose: The global burden of cancer is considerable, particularly in low and middle-income countries. Massachusetts General Hospital (MGH) and Botswana-Harvard AIDS Institute have partnered with the oncology community and government of Botswana to form BOTSOGO (BOTSwana Oncology Global Outreach) to address the rising burden of cancer in Botswana. Currently, radiation therapy (RT) is only available at a single linear accelerator (LINAC) in Gaborone Private Hospital (GPH). BOTSOGO worked to limit the absence of RT during a LINAC upgrade and ensure a safe transition to modern radiotherapy techniques. Methods: The existing Elekta Precise LINAC was decommissioned in November 2015 and replaced with a new Elekta VERSA-HD with IMRT/VMAT/CBCT capability. Upgraded treatment planning and record-and-verify systems were also installed. Physicists from GPH and MGH collaborated during an intensive on-site visit in Botswana during the commissioning process. Measurements were performed using newly purchased Sun Nuclear equipment. Photon beams were matched with an existing model to minimize the time needed for beam modeling and machine down time. Additional remote peer review was also employed. Independent dosimetry was performed by irradiating OSLDs, which were subsequently analyzed at MGH. Results: Photon beam quality agreed with reference data within 0.2%. Electron beam data agreed with example clinical data within 3%. Absolute dose calibration was performed using both IAEA and AAPM protocols. Absolute dose measurements with OSLDs agreed within 5%. Quentry cloud-based software was installed to facilitate remote review of treatment plans. Patient treatments resumed in February 2016. The time without RT was reduced, therefore likely resulting in reduced patient morbidity/mortality. Conclusion: A global physics collaboration was utilized to commission a modern LINAC in a resource-constrained setting. This can be a useful model in other areas with limited resources. Further use of technology and on-site exchanges will facilitate the introduction of more advanced techniques in Botswana. We acknowledge funding support from the AAPM International Educational Activities Committee and the NCI Federal Share Proton Beam Program Income Grant.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP3-01: Evaluation of Specific Absorption Rate and Temperature Increase Induced by Artificial Medical Implants During MRI Scan

Purpose: Heating of patients or burning of biological tissues around medical implants by RF power during MRI scan is a significant patient safety concern. The purpose of this study is to not only measure SAR values, but also RF-induced temperature elevation due to artificial hip joints during MRI scans. Methods: SAR measurement experiment was performed on three discrete manufacturers at 1.5 and 3T. Three MRI RF sequences (T1w TSE, T2w inversion recovery, and T2w TSE) with imaging parameters were selected. A gelled saline phantom mimicking human body tissue was made (Fig.1). FDTD method was utilized to calculate the SAR distribution using Sim4Life software. Based on the results of the simulation, 4 electrical field (E-field) sensors were located around two artificial hip joints inside the phantom. 56 Fiber Bragg Grating (FBG) temperature sensors (28 sensors on each artificial hip joint) were located on both left and right artificial hip joints to measure temperature change during MRI scan (Fig.1). Both E-field and FBG temperature sensors were calibrated with traceability at Korea Research Institute of Standards and Science (KRISS). Results: Simulation shows that high SAR values occur in the head and tail of the implanted artificial hip joints (Fig.1 lower right). 3T MRI scanner shows that the local averaged-SAR values measured by probe 1, 2, and 3 are 2.30, 2.77, and 1.68 W/kg, compared to MRI scanner-reported whole body SAR value (≤1.5 W/kg) for T1w TSE and T2w-IR (Table 1). The maximum temperature elevation measured by FBG sensors is 1.49°C at 1.5 T, 2.0°C at 3 T, and 2.56°C at 3 T for T1w TSE, respectively (Table 2). Conclusion: It is essential to assess the safety of MRI system for patient with medical implant by measuring not only accurate SAR deposited in the body, but also temperature elevation due to the deposited SAR during clinical MRI.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with the GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.

60 APPLIED LIFE SCIENCES↗

The effectiveness of pretreatment physics plan review for detecting errors in radiation therapy

Purpose: The pretreatment physics plan review is a standard tool for ensuring treatment quality. Studies have shown that the majority of errors in radiation oncology originate in treatment planning, which underscores the importance of the pretreatment physics plan review. This quality assurance measure is fundamentally important and central to the safety of patients and the quality of care that they receive. However, little is known about its effectiveness. The purpose of this study was to analyze reported incidents to quantify the effectiveness of the pretreatment physics plan review with the goal of improving it. Methods: This study analyzed 522 potentially severe or critical near-miss events within an institutional incident learning system collected over a three-year period. Of these 522 events, 356 originated at a workflow point that was prior to the pretreatment physics plan review. The remaining 166 events originated after the pretreatment physics plan review and were not considered in the study. The applicable 356 events were classified into one of the three categories: (1) events detected by the pretreatment physics plan review, (2) events not detected but “potentially detectable” by the physics review, and (3) events “not detectable” by the physics review. Potentially detectable events were further classified by which specific checks performed during the pretreatment physics plan review detected or could have detected the event. For these events, the associated specific check was also evaluated as to the possibility of automating that check given current data structures. For comparison, a similar analysis was carried out on 81 events from the international SAFRON radiation oncology incident learning system. Results: Of the 356 applicable events from the institutional database, 180/356 (51%) were detected or could have been detected by the pretreatment physics plan review. Of these events, 125 actually passed through the physics review; however, only 38% (47/125) were actually detected at the review. Of the 81 events from the SAFRON database, 66/81 (81%) were potentially detectable by the pretreatment physics plan review. From the institutional database, three specific physics checks were particularly effective at detecting events (combined effectiveness of 38%): verifying the isocenter (39/180), verifying DRRs (17/180), and verifying that the plan matched the prescription (12/180). The most effective checks from the SAFRON database were verifying that the plan matched the prescription (13/66) and verifying the field parameters in the record and verify system against those in the plan (23/66). Software-based plan checking systems, if available, would have potential effectiveness of 29% and 64% at detecting events from the institutional and SAFRON databases, respectively. Conclusions: Pretreatment physics plan review is a key safety measure and can detect a high percentage of errors. However, the majority of errors that potentially could have been detected were not detected in this study, indicating the need to improve the pretreatment physics plan review performance. Suggestions for improvement include the automation of specific physics checks performed during the pretreatment physics plan review and the standardization of the review process.

60 APPLIED LIFE SCIENCES↗

Atomic and electron structure of reconstructed (111) surface in ZnSe and CdSe crystals

The atomic and electron structure of four variants of polar (111)-(2 × 2) surfaces in ZnSe and CdSe terminated by a cation, namely, the ideal, relaxed, reconstructed, and relaxed after reconstruction surfaces, are calculated for the first time from the first principles. The surface is simulated by a film with a thickness of 12 atomic layers and a vacuum gap of ~16 Å in the layered superlattice approximation. Four fictitious hydrogen atoms with a charge of 0.5 electrons each are added for closing dangling Se bonds on the opposite side of the film. Ab initio calculations are performed using the QUANTUM ESPRESSO software based on the density functional theory. It is shown that relaxation results in splitting of atomic layers. We calculate and analyze the band structures and total and layer-wise densities of electron states for four variants of the surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Master-Slave Control Scheme in Electric Vehicle Smart Charging Infrastructure

WINSmartEV is a software based plug-in electric vehicle (PEV) monitoring, control, and management system. It not only incorporates intelligence at every level so that charge scheduling can avoid grid bottlenecks, but it also multiplies the number of PEVs that can be plugged into a single circuit. This paper proposes, designs, and executes many upgrades to WINSmartEV. These upgrades include new hardware that makes the level 1 and level 2 chargers faster, more robust, and more scalable. It includes algorithms that provide a more optimal charge scheduling for the level 2 (EVSE) and an enhanced vehicle monitoring/identification module (VMM) system that can automatically identify PEVs and authorize charging.

42 ENGINEERING↗

VERAView

In order to support engineering analysis of Virtual Environment for Reactor Analysis (VERA) model results, the Consortium for Advanced Simulation of Light Water Reactors (CASL) needs a tool that provides visualizations of HDF5 files that adhere to the VERAOUT specification. VERAView provides an interactive graphical interface for the visualization and engineering analyses of output data from VERA. The Python-based software provides instantaneous 2D and 3D images, 1D plots, and alphanumeric data from VERA multi-physics simulations.

Lee, RonaldW.↗

Geospatial Toolkit

The Geospatial Toolkit is an NREL-developed map-based software application that integrates resource data and other geographic information systems (GIS) data for integrated resource assessment. The non-resource, country-specific data for each toolkit comes from a variety of agencies within each country as well as from global datasets. Originally developed in 2005, the Geospatial Toolkit was completely redesigned and re-released in November 2010 to provide a more modern, easier-to-use interface with considerably faster analytical querying capabilities. The revised version of the Geospatial Toolkit has been released for all original toolkit countries/regions and each software package is made available on NREL's website,

Source record↗

Web of Registries Search (WoRS) v1.0.0

The Web of Registries Search (WoRs) is a web based software application that enables users to search for publicly available biological parts using keywords or sequence fragments. For the initial version (1.0.0) of the application, WoRS targets 10 sources of biological part data: the GenBank NIH genetic sequence database (https://www.ncbi.nlm.nih.gov/genbank/), the iGem parts registry (parts.igem.org), the Addgene plasmid repository (https://www.addgene.org/), and 7 Inventory of Composable Elements (ACS Synbio, JGI, JBEI, JBEI Public, ABF, SynBerc, ABF Public) registry instances. WoRs has built-in automated web scrapers which extract data from sources that do not have a public or well-defined application programming interface (API). They extract as much public data as they can find and create a searchable index to speed up searches. Included in the indexed information is the source of the information.

Plahar, Hector↗

SkX_NN: Neural Network for skyrmion identification in Lorentz TEM

A neural network for segmenting and processing Lorentz TEM images of skyrmion lattices. This software based on U-Net architecture is capable of identifying skyrmions in out-of-focus Lorentz TEM images based on training data. This isspecifically useful for analyzing large area data from in-situ experiments.

PHATAK, CHARUDATTA↗

Sandia Contributions to WaterTAP

SAND2023-06591O Through National Alliance for Water Innovation funding, Sandia will be contributing to the Water treatment Technoeconomic Assessment Platform (WaterTAP) project. WaterTAP is an open-source, Python-based software package that supports the technoeconomic assessment of full water treatment trains. WaterTAP includes a modular water treatment model library spanning a broad set of water treatment processes composed of unit, property, and costing models.

Rawlings, EdnaSoraya↗

Spatial Environmental Assessment Tool (SEAT)

SAND2024-08551O The Spatial Environmental Assessment Tool (SEAT) evaluates potential environmental risk associated with marine energy device deployment by coupling modeled impacts with risk severity maps. As a graphical user interface-based software, it interacts with marine energy stressor and receptor data to evaluate the risk of changes to marine environment. SEAT, which relies on spatial and temporal data, is a plug-in for geospatial software QGIS. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Chartrand, Chris↗

IN-SPIRE

IN-SPIRE™ can quickly and automatically convey the gist of large sets of unformatted text documents such as technical reports, web data, newswire feeds and message traffic. By clustering similar documents together, this Windows-based software unveils common themes and reveals hidden relationships within the collection. IN-SPIRE™ allows analysts to spend more time exploring the information they find most relevant and less time sifting through the masses of irrelevant documents.

Calapristi, A J↗

Energy Connector [SWR-26-014]

The Energy Connector is a web-based software application that is designed to facilitate energy bill savings for low-income households through streamlined community solar subscriptions. By using the Connector, Developers and Subscription Managers can save money on acquisition costs and streamline enrollment without having to perform additional income verification.

Rivard, Tim [National Laboratory of the Rockies (N↗

radkit base v1.6

The radkit (base) software suite (python) consists of three primary libraries: stark, trajan, and curie. The trajan library provides the tools to analyze and manipulate data from lidar and inertial measurement unit (IMU) devices, cameras, as well as trajectories from algorithms such as simultaneous localization and mapping (SLAM). These components allow reading and writing standard data formats, performing rigid affine transformations, discretizing three-dimensional space, and visualizing data products. The curie library comprises a standard set of object-oriented tools for radiation data and analysis in the following modules: (1) listmode and binmode data classes with methods for manipulation, plotting, slicing and file IO; (2) radiological/nuclear source detection/identification analysis results; (3) source encounters of correlated analyses and (4) energy-dependent angular detector response functions. The stark package provides low-level tools that are leveraged by both curie and trajan. The tools are flexible for offline analysis as well as performant for real-time integrations.

Salathe, Marco [Lawrence Berkeley National Laborat↗

A survey on software methods to improve the energy efficiency of parallel computing

Energy consumption is one of the top challenges for achieving the next generation of supercomputing. Codesign of hardware and software is critical for improving energy efficiency (EE) for future large-scale systems. Many architectural power-saving techniques have been developed, and most hardware components are approaching physical limits. Accordingly, parallel computing software, including both applications and systems, should exploit power-saving hardware innovations and manage efficient energy use. In addition, new power-aware parallel computing methods are essential to decrease energy usage further. This article surveys software-based methods that aim to improve EE for parallel computing. It reviews the methods that exploit the characteristics of parallel scientific applications, including load imbalance and mixed precision of floating-point (FP) calculations, to improve EE. In addition, this article summarizes widely used methods to improve power usage at different granularities, such as the whole system and per application. In particular, it describes the most important techniques to measure and to achieve energy-efficient usage of various parallel computing facilities, including processors, memories, and networks. Overall, this article reviews the state-of-the-art of energy-efficient methods for parallel computing to motivate researchers to achieve optimal parallel computing under a power budget constraint.

97 MATHEMATICS AND COMPUTING↗