The space station power system

The manned space station is the next major NASA program. It presents many challenges to the power system designers. The power system in turn is a major driver on the overall configuration. In this paper, the major requirements and guidelines that affect the station configuration and the power system are explained. The evolution of the space station power system from the NASA program development-feasibility phase through the current preliminary design phase is described. Several early station concepts, both fanciful and feasible, are described and linked to the present concept. The recently completed Phase B trade study selections of photovoltaic system technologies are described in detail. A summary of the present solar dynamic and power management and distribution systems is also given for completeness.

Baraona, C. R.↗

Systems definition space-based power conversion systems

Potential space-located systems for the generation of electrical power for use on Earth are discussed and include: (1) systems producing electrical power from solar energy; (2) systems producing electrical power from nuclear reactors; and (3) systems for augmenting ground-based solar power plants by orbital sunlight reflectors. Systems (1) and (2) would utilize a microwave beam system to transmit their output to Earth. Configurations implementing these concepts were developed through an optimization process intended to yield the lowest cost for each. A complete program was developed for each concept, identifying required production rates, quantities of launches, required facilities, etc. Each program was costed in order to provide the electric power cost appropriate to each concept.

Source record↗

Starr - An expert system for failure diagnosis in a space based power system

Starr, a prototype expert system, is designed to monitor and model a space power system, recognize problem states, identify the failure, and recommend the proper action to be taken. The system was modeled on the autonomously managed power system (AMPS) breadboard at NASA-Marshall. An object-oriented approach was used for the Starr model.

Walls, Bryan↗

NASA/DOD Flight Experiments Technical Interchange Meeting Proceedings

This document contains the proceedings of the Flight Experiments Technical Interchange Meeting held in Monterey California, October 5-9, 1992. Technical sessions 4 through 8 addressing space structures, propulsion, space power systems, space environments and effects, and space operations are covered. Many of the papers are presented in outline and viewgraph form.

Source record↗

Ultracapacitor-Based Uninterrupted Power Supply System

The ultracapacitor-based uninterrupted power supply (UPS) system enhances system reliability; reduces life-of-system, maintenance, and downtime costs; and greatly reduces environmental impact when compared to conventional UPS energy storage systems. This design provides power when required and absorbs power when required to smooth the system load and also has excellent low-temperature performance. The UPS used during hardware tests at Glenn is an efficient, compact, maintenance-free, rack-mount, pure sine-wave inverter unit. The UPS provides a continuous output power up to 1,700 W with a surge rating of 1,870 W for up to one minute at a nominal output voltage of 115 VAC. The ultracapacitor energy storage system tested in conjunction with the UPS is rated at 5.8 F. This is a bank of ten symmetric ultracapacitor modules. Each module is actively balanced using a linear voltage balancing technique in which the cell-to-cell leakage is dependent upon the imbalance of the individual cells. The ultracapacitors are charged by a DC power supply, which can provide up to 300 VDC at 4 A. A constant-voltage, constant-current power supply was selected for this application. The long life of ultracapacitors greatly enhances system reliability, which is significant in critical applications such as medical power systems and space power systems. The energy storage system can usually last longer than the application, given its 20-year life span. This means that the ultracapacitors will probably never need to be replaced and disposed of, whereas batteries require frequent replacement and disposal. The charge-discharge efficiency of rechargeable batteries is approximately 50 percent, and after some hundreds of charges and discharges, they must be replaced. The charge-discharge efficiency of ultracapacitors exceeds 90 percent, and can accept more than a million charges and discharges. Thus, there is a significant energy savings through the efficiency improvement, and there is far less downtime for applications and labor involved in replacing an ultracapacitor versus batteries. Also, the lengthy lifespan of this design would greatly reduce the disposal problems posed by lead acid, nickel cadmium, lithium, and nickel metal hydride batteries. This innovation is recyclable by nature, which further reduces system costs. The disposal of ultracapacitors is simple, as they are constructed of non-hazardous components. They are also safer than batteries in that they can be easily discharged, and left indefinitely in a safe, discharged state where batteries cannot.

Eichenberg, Dennis J.↗

NASCAP modelling of high-voltage power system interactions with space charged-particle environments

A simple space power system operating in geosynchronous orbit was analyzed. This system consisted of two solar array wings and a central body. Each solar array wing was considered to be divided into three regions operating at 2000 volts. The center body was considered to be an electrical ground with the array voltages both positive and negative relative to ground. The system was analyzed for both a normal environment and a moderate geomagnetic substorm environment. Initial results indicate a high probability of arcing at the interconnects on the negative operating voltage wing. The dielectric strength of the substrate may be exceeded giving rise to breakdown in the bulk of the material. The geomagnetic substorm did not seem to increase the electrical gradients at the interconnects on the negative operating voltage wing but did increase the gradients on the positive operating voltage wing which could result in increased coupling current losses.

Stevens, N. J.↗

Evolution of systems concepts for a 100 kWe class Space Nuclear Power System

Conceptual designs for the SP-100 Space Nuclear Power System have been prepared that meet baseline, backup and growth program scenarios. Near-term advancement in technology was considered in the design of the Baseline Concept. An improved silicon-germanium thermoelectric technique is used to convert the heat from a fast-spectrum, liquid lithium cooled reactor. This system produces a net power of 100 kWe with a 10-year end of life, under the specific constraints of area and volume. Output of the Backup Concept is estimated to be 60 kWe for a 10-year end of life. This system differs from the Baseline Concept because currently available thermoelectric conversion is used from energy supplied by a liquid sodium cooled reactor. The Growth Concept uses Stirling engine conversion to produce 100 kWe within the constraints of mass and volume. The Growth Concept can be scaled up to produce a 1 MWe output that uses the same type reactor developed for the Baseline Concept. Assessments made for each of the program scenarios indicate the key development efforts needed to initiate detailed design and hardware program phases. Development plans were prepared for each scenario that detail the work elements and show the program activities leading to a state of flight readiness.

Katucki, R.↗

Energy loss analysis of an integrated space power distribution system

The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

Kankam, M. David↗

Energy loss analysis of an integrated space power distribution system

The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

Kankam, M. D.↗

Advanced space solar dynamic power systems beyond IOC Space Station

Three different solar dynamic power cycle systems were evaluated for application to missions projected beyond the IOC Space Station. All three systems were found to be superior to two photovoltaic systems (a planar silicon array and a GaAs concentrator array), with both lower weight and area. The alkali-metal Rankine cycle was eliminated from consideration due to low performance, and the Stirling cycle was found to be superior to the closed Brayton cycle in both weight and area. LiF salt, which establishes peak cycle temperatures for both of the considered cycles at about 1090 K, was shown to be the most suitable material for Thermal Energy Storage.

Wallin, Wayne E.↗

SPACE: Three Decades of Spacecraft Power Systems Analysis with Fortran

The SPACE (System Power Analysis for Capability Evaluation) Fortran program developed at NASA Glenn Research Center has enabled power generation predictions and energy balance analyses for spacecraft electrical power systems (EPS) since 1988. SPACE was originally designed to analyze the EPS of the Space Station Freedom and continues to support certifications for visiting vehicles and extravehicular activities on the International Space Station today. Another version of SPACE currently supports design and mission planning operations for the Orion and Gateway vehicles as part of NASA’s Artemis program. In total, over 50 engineers have contributed to the development and use of SPACE on various platforms throughout its history. Ongoing code modernization efforts aim to generalize the program for use with different vehicles and configurations. While SPACE team analysts currently interact with the program via the command line, future development work also includes the creation of a graphical user interface for use by flight operations personnel. The SPACE code thus has a long legacy in spacecraft EPS analysis and will continue to play a critical role in future human spaceflight missions by leveraging the computational power of Fortran.

Fortran↗

Summary of gas bearing applications in the field of space electric power systems.

The NASA-Lewis Research Center is investigating the technology of closed Brayton cycle electric power systems for space. The turbine-alternator-compressor power conversion unit for such a system is designated Brayton Rotating Unit (BRU). In parallel to power system testing, a BRU improvement effort was initiated. A major portion of this effort involves the testing and evaluation of different bearing systems. A description of each bearing is presented along with results of the evaluation to date and a comparison of the merits and limitations of each bearing.

Dunn, J. H.↗

High capacity power systems for space

Candidate high-power supply systems for future space missions are discussed. Solar cells, particularly made from GaAs materials, are projected to be amenable large arrays that will have a 10 yr lifetime with a 15 percent efficiency at the end. Concentrator arrays using GaAs cells could furnish over 200 W/sq m with 100 suns irradiance. Different battery systems, other than the present low-power NiCd storage systems, will be required, and could be either fuel cell systems or NiH2 batteries. The flywheel also offers promise, especially if integrated within the attitude control system. Solar thermal systems are also possible, featuring SiGe thermocouples, or boron alloys or rare earth calcogenides in thermoelectric generators or thermionic converters equipped with alkali metal elements. Mechanical systems, notably the Brayton cycle engine, offer multihundredwatt performance and higher, with at least 3.5 yr lifetimes. Experimentation is still needed to characterize the power supply interaction with the spacecraft environment and to design efficient and long-lasting radiators if heat engines are implemented.

Mullin, J. P.↗

Space Station power system autonomy demonstration

The Systems Autonomy Demonstration Program (SADP) represents NASA's major effort to demonstrate, through a series of complex ground experiments, the application and benefits of applying advanced automation technologies to the Space Station project. Lewis Research Center (LeRC) and Marshall Space Flight Center (MSFC) will first jointly develop an autonomous power system using existing Space Station testbed facilities at each center. The subsequent 1990 power-thermal demonstration will then involve the cooperative operation of the LeRC/MSFC power system with the Johnson Space Center (JSC's) thermal control and DMS/OMS testbed facilities. The testbeds and expert systems at each of the NASA centers will be interconnected via communication links. The appropriate knowledge-based technology will be developed for each testbed and applied to problems requiring intersystem cooperation. Primary emphasis will be focused on failure detection and classification, system reconfiguration, planning and scheduling of electrical power resources, and integration of knowledge-based and conventional control system software into the design and operation of Space Station testbeds.

Kish, James A.↗

A new Space Station power system

A new concept for a Space Station power system is proposed which reduces the drag effect of the solar panels and eliminates eclipsing by the Earth. The solar generator is physically separated from the Space Station, and power transmitted to the station by a microwave beam. The power station can thus be placed high enough that drag is not a significant factor. For a resonant orbit where the ratio of periods s:p is a ratio of odd integers, and the orbital planes nearly perpendicular, an orbit can be chosen such that the line of sight is never blocked if the lower orbit has an altitude greater than calculatable mininum. For the 1:3 resonance, this minimum altitude is 0.5 r(e). Finally, by placing the power station into a sun-synchronous orbit, it can be made to avoid shadowing by the Earth, thus providing continuous power.

Landis, Geoffrey A.↗

The effects of nonlinear loading upon the Space Station Freedom 20 kHz power system

The Space Station Freedom power distribution system, which consists of dual redundant 20-kHz, 440-V RMS, single-phase power systems, is discussed. The effect of a typical space station nonlinear load on the measurement of RMS current and voltage at various points in the space station power system has been investigated using the Electromagnetic Transients Program (EMTP). The load current distortion at the user interface, its effect on the distribution system, and its relationship to power factor have been studied. Modeling results are compared to test data. The differences under nonlinear loading are evaluated and presented as a measure of distribution voltage distortion and current measurement accuracy.

Leskovich, R. Thomas↗

An out-of-core thermionic-converter system for nuclear space power

Design of the nuclear thermionic space power system, 40 50 70 Kw(e) power range, are given. The design configuration (1) meets the constraints of readily available launch vehicles; (2) allows for off-design operation including startup, shutdown, and possible emergency conditions; (3) provides tolerance of failure by extensive use of modular, redundant elements; (4) incorporates and uses heat pipes in a fashion that reduces the need for extensive in-pile testing of system components; and (5) uses thermionic converters, nuclear fuel elements, and heat transfer devices in a geometrical form adapted from existing incore thermionic system designs. Designs and in some cases performance data for elements and groups of the elements of the system are included. Benefits of the highly modular system approach to reliability, safety, economy of development, and flexibility are discussed.

Breitwieser, R.↗