Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Influence of simple terrain on the spatial variability of a low-level jet and wind farm performance in the AWAKEN field campaign

In wind energy research, scientific challenges are often associated with complex terrain sites, where orography, vegetation, and buildings disrupt flow uniformity. However, even sites characterized as simple terrain can exhibit significant spatial variability in wind speed, particularly during stable boundary layers (SBLs) and low-level jets (LLJs). This study investigates these terrain interactions using both simulations and observations from the American WAKe ExperimeNt (AWAKEN). We employ a multiscale Weather Research and Forecasting (WRF) model simulation, integrating mesoscale forcing in the coarse domains and representing three rows of turbines from the King Plains wind farm as generalized actuator disks (GAD) in the large-eddy simulation (LES) domains. During a nocturnal LLJ event on 3 April 2023, the downstream, wake-affected turbine rows outperformed the upstream, unwaked row by 25 %–51 %. This counterintuitive result arises from terrain-induced streamwise variations in hub-height wind speed of approximately 4 m s −1 over 5 km – equivalent to ∼50 % of the upstream reference speed. This enhancement outweighs the wake-induced reduction in mean wind speed (∼12 %) and global blockage effects reported in the literature (∼1 %–3.4 %). The multiscale simulations capture the intra-farm spatial variability in power performance observed in SCADA data. Terrain-induced vertical displacement of the LLJ, coupled with large wind shear below the jet maximum, drives the substantial streamwise acceleration within the wind farm. These findings underscore the importance of accounting for spatial variability related to terrain, even in simple landscapes, particularly during LLJ conditions. Incorporating such effects into reduced-order modeling frameworks for wind farm design and control could significantly enhance their effectiveness.

17 WIND ENERGY↗

AGR-3/4 TRISO Fuel Compact Ceramography

The combined third and fourth irradiation in the Advanced Gas Reactor (AGR) program (AGR-3/4) contained tristructural isotropic (TRISO)-coated particle fuel and designed-to-fail (DTF) fuel particles. The DTF particles were only coated with highly anisotropic pyrocarbon (PyC) so they would purposely fail during the AGR-3/4 irradiation and provide a source of fission products for measurement. To observe the post-irradiation morphology of these DTF particles and the TRISO-coated particles, three AGR-3/4 compacts were mounted in epoxy, sectioned above their centerlines, and ground/polished. Three rounds of grinding/polishing and optical microscopy were performed so that the particles could be observed at multiple planes. Each compact contained approximately 1,872 TRISO particles and exactly 20 DTF particles. The three AGR-3/4 compacts examined covered a wide temperature range and featured both the hottest average irradiation temperature (1375°C) and the coldest/lowest burnup (872°C and 5.5% fissions per initial metal atom) of any compacts to undergo post-irradiation examination (PIE) in the AGR program to date. A total of 29 DTF particles were located and observed via microscopy across the three compacts. All the DTF particles observed via microscopy had completely failed PyC coatings. Some different DTF kernel and PyC morphologies were observed that have been attributed to the differences in irradiation temperature and/or burnup. At low and medium irradiation temperatures (roughly 850 to 1050°C), it appears irradiation-induced dimensional changes in the DTF PyC caused it to fracture and fold in on itself, and the kernel deformed to accommodate this PyC deformation. The extent of DTF kernel deformation to accommodate DTF PyC buckling tended to be greater for the medium-temperature fuel compared to the cold fuel. In the high-irradiation-temperature compact (1375°C), the DTF PyC layer appears to have completely reacted chemically with the kernel material. The only material surrounding the DTF particles in this hot compact resembles the compact matrix material. Observations of the TRISO-coated driver fuel particles and fuel compact graphitic matrix were also made. The TRISO particle kernels in the medium-temperature compact (1047°C), and many in the high-temperature compact (1375°C), showed morphologies consistent with what was seen in AGR-1 and AGR-2. In other TRISO particles from the high-temperature compact, a spatial gradient in the kernel appearance was evident. Here the cool side of the kernel (away from the center of the compact) had a much darker appearance (like that of the buffer and pyrocarbon). This is the first observation of this kind of kernel spatial gradient in AGR fuel. It is believed that the high irradiation temperature of that compact (an average of 1375°C) activates or accelerates an unidentified chemical reaction, and the temperature gradient within the fuel causes a sharp spatial gradient. The low-temperature/low-burnup compact also showed unique kernel morphologies where the TRISO-coated particles had clearly distinguishable oxide and carbide phases at the center of the kernel, an oxide rind surrounding this, and remnants of a carbide skin surrounding the oxide rind. These are features observed in the as-fabricated fuel that are no longer present in higher burnup fuel. Occasional gaps between the outer pyrolytic carbon (OPyC) and graphitic matrix material were observed in all compacts. Gaps were most often found in the small, matrix-filled spaces between adjacent particles. Finally, buffer morphologies in AGR-3/4 TRISO particles were like those observed in AGR-1 and AGR-2, and the buffer fracture frequencies in AGR-3/4 and AGR-2 TRISO particles were plotted versus fast neutron fluence and irradiation temperature. In AGR-3/4 the buffer fracture rate was highest (23%) for an irradiation temperature of 1047°C and a fast fluence of 5.18E25 n/m 2 . Increasing the irradiation temperature to 1375°C reduced the buffer fracture rate to 14%. Reducing the irradiation temperature to 872°C and the fast fluence by a factor of 3 reduced the buffer fracture rate to 7%. The temperature and fluence dependencies observed for AGR-3/4 buffer fracture were consistent with those observed in AGR-2. Lower fluences and/or higher temperatures significantly reduced the buffer fracture frequencies. Lower buffer fracture frequencies were also observed at lower temperatures as long as the fluence was also significantly reduced. This is believed to be due to lower fluence resulting in less irradiation-induced dimensional change (shrinkage) of the buffer, and a higher temperature promoting enhanced creep relaxation of stresses within the buffer, leading to less buffer fracture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA

Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. The fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.

60 APPLIED LIFE SCIENCES↗

Deducing Electron Properties from Hard X-Ray Observations

X-radiation from energetic electrons is the prime diagnostic of flare-accelerated electrons. The observed X-ray flux (and polarization state) is fundamentally a convolution of the cross-section for the hard X-ray emission process(es) in question with the electron distribution function, which is in turn a function of energy, direction, spatial location and time. To address the problems of particle propagation and acceleration one needs to infer as much information as possible on this electron distribution function, through a deconvolution of this fundamental relationship. This review presents recent progress toward this goal using spectroscopic, imaging and polarization measurements, primarily from the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI). Previous conclusions regarding the energy, angular (pitch angle) and spatial distributions of energetic electrons in solar flares are critically reviewed. We discuss the role and the observational evidence of several radiation processes: free-free electron-ion, free-free electron-electron, free-bound electron-ion, photoelectric absorption and Compton backscatter (albedo), using both spectroscopic and imaging techniques. This unprecedented quality of data allows for the first time inference of the angular distributions of the X-ray-emitting electrons and improved model-independent inference of electron energy spectra and emission measures of thermal plasma. Moreover, imaging spectroscopy has revealed hitherto unknown details of solar flare morphology and detailed spectroscopy of coronal, footpoint and extended sources in flaring regions. Additional attempts to measure hard X-ray polarization were not sufficient to put constraints on the degree of anisotropy of electrons, but point to the importance of obtaining good quality polarization data in the future.

Kontar, E. P.↗

Acceleration and focusing of plasma flows

The acceleration of flowing plasmas is a fundamental problem that is useful in a wide variety of technological applications. We consider the problem from the perspective of plasma propulsion. Gridded ion thrusters and Hall thrusters are the most commonly used devices to create flowing plasma for space propulsion, but both suffer from fundamental limitations. Gridded ion sources create good quality beams in terms of energy spread and spatial divergence, but the Child-Langmuir law in the non-neutral acceleration region limits the maximum achievable current density. Hall thrusters avoid this limitation by accelerating ions in quasi-neutral plasma but, as a result, produce plumes with high spatial divergence and large energy spread. In addition the more complicated magnetized plasma in the Hall Thruster produces oscillations that can reduce the efficiency of the thruster by increasing electron transport to the anode. We present investigations of three techniques to address the fundamental limitations on the performance of each thruster. First, we propose a method to increase the time-averaged current density (and thus thrust density) produced by a gridded ion source above the Child-Langmuir limit by introducing time-varying boundary conditions. Next, we use an electrostatic plasma lens to focus the Hall thruster plume, and finally we develop a technique to suppress a prominent oscillation that degrades the performance of Hall thrusters. The technique to loosen the constraints on current density from gridded ion thrusters actually applies much more broadly to any space charge limited flow. We investigate the technique with a numerical simulation and by proving a theoretical upper bound. While we ultimately conclude that the approach is not suitable for space propulsion, our results proved useful in another area, providing a benchmark for research into the spontaneously time-dependent current that arises in microdiodes. Next, we experimentally demonstrate a novel approach to reducing plume divergence by using a PL located in the plume of the thruster to focus ions after they were ionized and accelerated. Finally we further improve thruster operation by suppressing a prominent low frequency oscillation in the thruster known as the rotating spoke. The suppression leads to decreased electron transport and more control over the operating conditions in the thruster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Particle acceleration in the dynamic magnetotail: Orbits in self-consistent three-dimensional MHD fields

The acceleration of protons in a dynamically evolving magnetotail is investigated by tracing particles in the fields obtained from a three-dimensional resistive magnetohydrodynamic (MHD) simulation. The MHD simulation, representing plasmoid formation and ejection through a near-Earth reconnection process, leads to cross-tail electric fields of up to approximately 4 mV/m with integrated voltages across the tail of up to approximately 200 kV. Energization of particles takes place over a wide range along the tail, due to the large spatial extent of the increased electric field together with the finite cross-tail extent of the electric field region. Such accelerated particles appear earthward of the neutral line over a significant portion of the closed field line region inside of the separatrix, not just in the vicinity of the separatrix. Two different acceleration processes are identified: a 'quasi-potential' acceleration, due to particle motion in the direction of the cross-tail electric field, and a 'quasi-betatron' effect, which consists of multiple energy gains from repeated crossings of the acceleration region, mostly on Speiser-type orbits, in the spatially varying induced electric field. The major source region for accelerated particles in the hundreds of keV range is the central plasma sheet at the dawn flank outside the reconnection site. Since this source plasma is already hot and dense, its moderate energization by a factor of approximately 2 may be sufficient to explain the observed increases in the energetic particle fluxes. Particles from the tail are the source of beams at the plasma sheet/lobe boundary. The temporal increase in the energetic particle fluxes, estimated from the increase in energy gain, occurs on a fast timescale of a few minutes, coincident with a strong increase in B(sub z), despite the fact that the inner boundary ('injection boundary') of the distribution of energized particles is fairly smooth.

Birn, Joachim↗

Oxygen Ion Heat Rate within Alfvenic Turbulence in the Cusp

The role that the cleft/cusp has in ionosphere-magnetosphere coupling makes it a dynamic and important region. It is directly exposed to the solar wind, making it possible for the entry of electromagnetic energy and precipitating electrons and ions from dayside reconnection and other dayside events. It is also a significant source of ionospheric plasma, contributing largely to the mass loading of the magnetosphere with large fluxes of outflowing ions. Crossing the cusp/cleft near 5100 km, the Polar instruments observe the common correlation of downward Poynting flux, ion energization, soft electron precipitation, broadband extremely low-frequency (BB-ELF) emissions, and density depletions. The dominant power in the BB-ELF emissions is now identified to be from spatially broad, low frequency Alfv nic structures. For a cusp crossing, we determine using the Electric Field Investigation (EFI), that the electric and magnetic field fluctuations are Alfv nic and the electric field gradients satisfy the inequality for stochastic acceleration. With all the Polar 1996 horizontal crossings of the cusp, we determine the O+ heating rate using the Thermal Ion Dynamics Experiment (TIDE) and Plasma Wave Investigation (PWI). We then compare this heating rate to other heating rates assuming the electric field gradient criteria exceeds the limit for stochastic acceleration for the remaining crossings. The comparison suggests that a stochastic acceleration mechanism is operational and the heating is controlled by the transverse spatial scale of the Alfvenic waves.

Coffey, Victoria N.↗

Influence of the neutron-skin effect on nuclear isobar collisions at energies available at the BNL Relativistic Heavy Ion Collider

The unambiguous observation of a Chiral Magnetic Effect (CME)-driven charge separation is the core aim of the isobar program at RHIC consisting of $96\atop{40}$Zr+$96\atop{40}$Zr and $96\atop{44}$Ru+$96\atop{44}$Ru collisions at √s NN = 200 GeV. We quantify the role of the spatial distributions of the nucleons in the isobars on both eccentricity and magnetic field strength within a relativistic hadronic transport approach (SMASH, Simulating Many Accelerated Strongly-interacting Hadrons). In particular, we introduce isospin-dependent nucleon-nucleon spatial correlations in the geometric description of both nuclei, deformation for $96\atop{44}$Ru and the so-called neutron skin effect for the neutron-rich isobar i.e. $96\atop{40}$Zr. The main result of this study is a reduction of the magnetic field strength difference between $96\atop{44}$Ru+$96\atop{44}$Ru and $96\atop{40}$Zr+$96\atop{40}$Zr by a factor of 2, from 10% to 5% in peripheral collisions when the neutron-skin effect is included. Further, we find an increase of the eccentricity ratio between the isobars by up to 10% in ultra-central collisions as due to the deformation of $96\atop{44}$Ru while neither the neutron skin effect nor the nucleon-nucleon correlations result into a significant modification of this observable with respect to the traditional Woods-Saxon modeling. Our results suggest a significantly smaller CME signal to background ratio for the experimental charge separation measurement in peripheral collisions with the isobar systems than previously expected.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Large area, high spatial resolution tracker for new generation of high luminosity experiments in Hall A at Jefferson Lab

In 2014 the CEBAF electron accelerator at Jefferson Lab (JLab) will deliver a longitudinally polarized (up to 85%), high intensity (up to 100 μA) beam with maximum energy of 12 GeV, twice the present value. To exploit the new opportunities that the energy upgrade will offer, a new spectrometer (Super BigBite - SBS) is under development, featuring very forward angle, large acceptance and ability to operate in high luminosity environment. The tracking system of SBS will consist of large area (40×150 cm2 and 50×200 cm2), high spatial resolution (better than 100 μm) chambers based on the GEM technology and 2 small (10×20 cm) Silicon Strip Detector planes. The design of the GEM chambers and its sub-components such as the readout electronics is resented here.

43 PARTICLE ACCELERATORS↗

SU-F-J-30: Application of Intra-Fractional Imaging for Pretreatment CBCT of Breath-Hold Lung SBRT

Purpose: Clinical implementation of gated lung SBRT requires tools to verify the accuracy of the target positioning on a daily basis. This is a particular challenge on Elekta linacs where the XVI imaging system does not interface directly to any commercial gating solution. In this study, we used the Elekta’s intra-fractional imaging functionality to perform the pretreatment CBCT verifications and evaluated both the image quality and gating accuracy. Methods: To use intrafraction imaging tools for pretreatment verifications, we planned a 360-degree arc with 1mmx5mm MLC opening. This beam was designed to drive the gantry during the gated CBCT data collection. A Catphan phantom was used to evaluate the image quality for the intra-fractional CBCT. A CIRS lung phantom with a 3cm sphereinsert and a moving chest plate were programmed with a simulated breathhold breathing pattern was used to check the gating accuracy. A C-Rad CatalystHD surface mapping system was used to provide the gating signal. Results: The total delivery time of the arc was 90 seconds. The uniformity and low contrast resolution for the intra-fractional CBCT was 1.5% and 3.6%, respectively. The values for the regular CBCT were 1.7% and 2.5%, respectively. The spatial resolution was 7 line-pairs/cm and the 3D spatial integrity was less than 1mm for the intra-fractional CBCT. The gated CBCT clearly demonstrated the accuracy of the gating image acquisition. Conclusion: The intra-fraction CBCT capabilities on an Elekta linac can be used to acquire pre-treatment gated images to verify the accuracy patient positioning. This imaging capability should provide for accurate patient alignments for the delivery of lung SBRT. This research was partially supported by Elekta.

60 APPLIED LIFE SCIENCES↗

Relativistic magnetosonic shock waves in synchrotron sources - Shock structure and nonthermal acceleration of positrons

The theoretical properties of relativistic, transverse, magnetosonic collisionless shock waves in electron-positron-heavy ion plasmas of relevance to astrophysical sources of synchrotron radiation are investigated. Both 1D electromagnetic particle-in-cell simulations and quasi-linear theory are used to examine the spatial and kinetic structure of these nonlinear flows. A new process of shock acceleration of nonthermal positrons, in which the gyrating reflected heavy ions dissipate their energy in the form of collectively emitted, left-handed magnetosonic waves which are resonantly absorbed by the positrons immediately behind the ion reflection region, is described. Applications of the results to the termination shocks of pulsar winds and to the termination shocks of jets emanating from the AGN are outlined.

Hoshino, Masahiro↗

de Sitter nonlinear sigma model and accelerating universe

We consider a cosmology with a noncompact nonlinear sigma model. The target space is of de Sitter type and four scalar fields are introduced. The potential is absent but cosmological constant term {lambda} is added. One of the scalar fields is time dependent and the remaining three fields have no time dependence but only spatial dependence. We show that a very simple ansatz for the scalar fields results in the accelerating universe with an exponential expansion at late times. It is pointed out that the presence of the energy density and pressure coming from the spatial variation of the three scalar fields plays an essential role in our analysis which includes {lambda}=0 as a special case and it discriminate from the standard {lambda}-dominated acceleration. We perform a stability analysis of the solutions and find that some solutions are classically stable and attractor. We also present a nonperturbative solution which asymptotically approaches an exponential acceleration and discuss possible cosmological implications in relation to dark energy. It turns out that the equation of state approaches asymptotically {omega}=-1 both from above and below, but the crossing does not occur. It predicts present value of {omega}{approx}-1{+-}0.07, which is within the region allowed by the observational data. This solution also exhibits a power law expansion at early times, and the energy density of the scalar fields mimics that of the stiff matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ON THEORIES FOR STOCHASTIC ACCELERATION IN THE SOLAR WIND

The suprathermal tails on the distribution functions of ions in the solar wind are observed to have a common spectral shape in many different circumstances: a power law in particle speed with spectral index of -5. Three possible approaches for explaining these observations are considered: (1) the acceleration mechanism of Fisk and Gloeckler in which energy is redistributed from a core particle population into the suprathermal tail; (2) traditional stochastic acceleration in which particles are accelerated by damping turbulence; and (3) the statistical approach introduced by Schwadron et al. in which the -5 spectrum is formed by averaging over individual spectra. The acceleration mechanism of Fisk and Gloeckler has advantages: (1) it appears to occur in conditions that are readily satisfied: compressive turbulence that is thermally isolated (no large-scale spatial gradients), with a core distribution of particles with a sharp initial cutoff in particle speed, above which particles can spatially diffuse; and (2) it yields spectra that are consistent with observations. Traditional stochastic acceleration has the disadvantage that it is unlikely to yield spectral shapes consistent with observations, and the spectra are dependent upon the plasma conditions and thus unlikely to be the same in different circumstances. The statistical approach of Schwadron et al. can yield the -5 spectrum and is consistent with the results of Fisk and Gloeckler when the assumed distribution functions for individual events and the averaging technique are taken to be compatible with the assumptions and averaging in Fisk and Gloeckler.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of initial plasma density on laser induced ion acceleration

The effect of initial plasma density on the energetics of the laser accelerated ions is studied using one dimensional particle in cell simulations. It is observed that the initial plasma density plays an important role in the generation of high energy particles. In the case of a spatially constant initial density, there exists an optimum value for the maximum ion acceleration. Similarly for the case of a density ramp, an optimum value of ramp length exists for the maximum ion acceleration. At a laser intensity of 5x10{sup 20} W/cm{sup 2}, a maximum energy of about 1 GeV is seen with an optimum initial density ramp.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this technology will be developed and tested. This research project has been supported by a Marie Curie Early Initial Training Network Fellowship of the European Community's Seventh Framework Programme under contract number (PITN-GA-2011-289198-.

07 ISOTOPE AND RADIATION SOURCES↗

Quantifying the gantry sag on linear accelerators and introducing an MLC-based compensation strategy

Purpose: Gantry sag is one of the well-known sources of mechanical imperfections that compromise the spatial accuracy of radiation dose delivery. The objectives of this study were to quantify the gantry sag on multiple linear accelerators (linacs), to investigate a multileaf collimator (MLC)-based strategy to compensate for gantry sag, and to verify the gantry sag and its compensation with film measurements. Methods: The authors used the Winston-Lutz method to measure gantry sag on three Varian linacs. A ball bearing phantom was imaged with megavolt radiation fields at 10 deg. gantry angle intervals. The images recorded with an electronic portal imaging device were analyzed to derive the radiation isocenter and the gantry sag, that is, the superior-inferior wobble of the radiation field center, as a function of the gantry angle. The authors then attempted to compensate for the gantry sag by applying a gantry angle-specific correction to the MLC leaf positions. The gantry sag and its compensation were independently verified using film measurements. Results: Gantry sag was reproducible over a six-month measurement period. The maximum gantry sag was found to vary from 0.7 to 1.0 mm, depending on the linac and the collimator angle. The radiation field center moved inferiorly (i.e., away from the gantry) when the gantry was rotated from 0 deg. to 180 deg. After the MLC leaf position compensation was applied at 90 deg. collimator angle, the maximum gantry sag was reduced to <0.2 mm. The film measurements at gantry angles of 0 deg. and 180 deg. verified the inferior shift of the radiation fields and the effectiveness of MLC compensation. Conclusions: The results indicate that gantry sag on a linac can be quantitatively measured using a simple phantom and an electronic portal imaging device. Reduction of gantry sag is feasible by applying a gantry angle-specific correction to MLC leaf positions at 90 deg. collimator angle.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental characterization of discharge plasma dynamics in a square capillary for prospective applications in laser wakefield acceleration

Research on plasma generated by electrical discharge in gas-filled capillaries plays an important role in advancing laser wakefield accelerators. We present a comprehensive study of the temporal and spatial distribution of plasma density within a short, 1 cm long, square-shaped capillary filled with hydrogen gas. Two transverse capillary sizes, 500 μm and 300 μm, were investigated achieving peak plasma densities of 0.9 × 10 18 cm −3 and 2.5 × 10 18 cm −3 , respectively, at the capillary center. In addition, we explore how these distributions depend on discharge parameters, specifically discharge current and gas flow through the capillary. Plasma density was determined by analyzing the Stark broadening of the hydrogen Balmer-alpha line. The results obtained were compared with the theoretical models and simulations. The comparison between the model predictions and the experimental data at the transient ionization stage of the discharge reveals a discrepancy of a factor of ∼1.3–2.1, depending on the capillary size, which is thoroughly discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial Description of Lithium Plating

Fast charging lithium ion batteries is a critical obstacle to overcome before widespread uptake of electric vehicles. During fast charging, lithium ion batteries in electric vehicles degrade at an accelerated rate, which is frequently caused by lithium plating. In this presentation, three different methods to spatially and temporally detect and quantify lithium plating are presented; notably, mass spectroscopy titration, operando depth profiling X-ray diffraction, and in-situ X-ray diffraction mapping of pouch cells. Each of the tree techniques successfully quantify lithium plating and provide insight into its spatial occurrence within lithium ion cells.

47 OTHER INSTRUMENTATION↗