Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Dark energy or apparent acceleration due to a relativistic cosmological model more complex than the Friedmann-Lemaitre-Robertson-Walker model?

We use the Szekeres inhomogeneous relativistic models in order to fit supernova combined data sets. We show that with a choice of the spatial curvature function that is guided by current observations, the models fit the supernova data almost as well as the Lambda-CDM model without requiring a dark energy component. The Szekeres models were originally derived as an exact solution to Einstein's equations with a general metric that has no symmetries, and they are regarded as good candidates to model the true lumpy universe that we observe. The null geodesics in these models are not radial. The best fit model found is also consistent with the requirement of spatial flatness at cosmic microwave background scales. The first results presented here seem to encourage further investigations of apparent acceleration using various inhomogeneous models, and other constraints from cosmic microwave background and large structure need to be explored next.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining the Diffusion Coefficient with HAWC TeV Gamma-Ray Observations of Two Nearby Pulsar Wind Nebulae

Nearby electron/positron accelerators, mostly Pulsar Wind Nebulae (PWNe), have been pro- posed as potential origins of the positron excess above 10 GeV. The HAWC Observatory reveals two very extended sources spatially coincident with two nearby middle-aged pulsars: Geminga and PSR B0656+14, suggesting ultra-relativistic electrons/positrons accelerated in our backyard. Morphological studies on these two PWNe provide a constraint on the diffusion coefficient at HAWC energies. In this poster, we will present the model development and morphological studies on these PWNe, and the derived diffusion coefficient that best fits the data.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron acceleration in vacuum by subcycle laser pulse

An analytical expression based on the paraxial approximation describing the propagation of a subcycle axicon Gaussian laser pulse in vacuum is obtained. The broad spectrum of the ultrashort pulse is given in terms of a Taylor series in the main wave frequency. The spatial and temporal characteristics of the pulse are strongly coupled. The model is used to consider electron acceleration by the light pressure of an intense subcycle laser pulse. The pulse model can also be applied to other short pulse profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The relevance of particle flux monitors in accelerator-based activation analysis

One of the most critical parameters in activation analysis is the flux density of the activating radiation, its spatial distribution in particular. The validity of the basic equation for calculating the activity induced to the exposed item depends upon the fulfilment of several conditions, the most relevant of them being equal doses of incident activating radiation received by the unknown sample, the calibration material and the reference material, respectively. This requirement is most problematic if accelerator-produced radiation is used for activation. Whilst nuclear research reactors usually are equipped with exposure positions that provide fairly homogenous activation fields for thermal neutron activation analysis accelerator-generated particle beams (neutrons, photons, charged particles) usually exhibit axial and, in particular, sharp radial flux gradients. Different experimental procedures have been developed to fulfil the condition mentioned above. In this paper, three variants of the application of flux monitors in photon activation analysis are discussed (external monitor, additive and inherent internal monitor). Experiments have indicated that the latter technique yields highest quality of the analytical results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FY2011 Status Report on SN2ND Neutronics Solver Development

A change in focus of NEAMS to a broader set of reactor types necessitated significant effort being diverted away from SN2ND development in FY2011. Nevertheless, significant gains were made with regard to building the new preconditioner and meeting the objectives of 1) parallelism in energy, 2) a spatial multigrid concept, 3) using SN vector spaces to accommodate the adjoint and time dependent functionalities needed for NEAMS work, and 4) complete manuals and documentation. While the desired goal of an exportable SN2ND solver usable within the NEAMS community for neutronics analysis was not completed, we can be confident that this year’s work puts the SN2ND solver well on its way to meeting that objective. It is important to note that SN2ND is just as capable as any other methodology for doing thermal reactor analysis, but the motivation to execute on smaller scale machines has initiated focused development on simplified treatments such as those proposed in the MOCARV tool. All of the cited coding tasks were completed but not all are fully working (i.e. debugged). The spatial multigrid technique was by far the most time consuming part of the SN2ND development process. It required multiple new data structure concepts along with identifying the necessary changes in the vectors and their associated functions. Combining the spatial multigrid as part of a GMRES preconditioner operating on the full vector space, necessary for parallelization in energy, increased the complexity of that development. Research into spatial multigrid techniques for unstructured meshes, void treatments, and code optimization and acceleration are key development needs for SN2ND. Similar to previous years, a considerable amount of effort was spent on validation work. Again we focused on fast reactor problems such as ZPR experiments and the MONJU reactor in Japan. Conventional drawer homogenized models and partially heterogeneous models were used on the ZPR calculations. The drawer homogenized models produced excellent results for both eigenvalue and foil measurements on four loadings of ZPR-6/7. The partially heterogeneous models of ZPR-6/7 also produced good results, but additional work is necessary to generate consistent effective cross section data. Calculations for MONJU were homogeneous and also gave excellent results. Finally, mock-up heterogeneous calculations were setup and attempted to scope out the performance limitations of SN2ND on whole core heterogeneous calculations. Specifically, heterogeneous models of a PWR, a VHTR, and the MONJU reactor were created using anywhere from 2 group to 33 group cross section data. Meshes with greater than 100,000,000 vertices are necessary for accuracy and a specific non-scaling memory issue in PETSc restricted the SN2ND modeling (VHTR and PWR could not be solved). All of the calculations performed this year indicate that significant computational resources beyond those available today are required to obtain a high fidelity solution possible with SN2ND. The future goals for SN2ND are to get the new version fully working, reliable in execution, and to have comparable performance to the old solver such that it can be released within the NEAMS community. After its export to RSICC, we will rely upon further preconditioner research to be done in collaboration with university partners and through the exascale hub activities. Some of that research will focus on making SN2ND applicable to thermal reactor problems, spatial multigrid, and void treatments.

Smith, M. A.↗

In Situ Synchrotron-Based IR Microspectroscopy To Study Catalytic Reactions in Zeolite Crystals

CSI: Carbocation species identification: The nonhomogeneous distribution of the reaction products of styrene oligomerization on large ZSM-5 crystals was mapped with in situ IR microspectroscopy. Diffraction-limited spatial resolution was achieved with synchrotron light. IR spectra for possible reaction products were calculated with DFT/B3LYP; by comparison with experimental results carbocationic reaction species formed in zeolite channels could be singled out.

43 PARTICLE ACCELERATORS↗

Predictive Simulation and Design of Materials by Quasicontinuum and Accelerated Dynamics Methods

This project developed the hyper-QC multiscale method to make possible the computation of previously inaccessible space and time scales for materials with thermally activated defects. The hyper-QC method combines the spatial coarse-graining feature of a finite temperature extension of the quasicontinuum (QC) method (aka “hot-QC”) with the accelerated dynamics feature of hyperdynamics. The hyper-QC method was developed, optimized, and tested from a rigorous mathematical foundation.

97 MATHEMATICS AND COMPUTING↗

Accelerating Time Integration for the Shallow Water Equations on the Sphere Using GPUs

The push towards larger and larger computational platforms has made it possible for climate simulations to resolve climate dynamics across multiple spatial and temporal scales. This direction in climate simulation has created a strong need to develop scalable time-stepping methods capable of accelerating throughput on high performance computing. This work details the recent advances in the implementation of implicit time stepping on a spectral element cube-sphere grid using graphical processing units (GPU) based machines. We demonstrate how solvers in the Trilinos project are interfaced with ACME and GPU kernels can significantly increase computational speed of the residual calculations in the implicit time stepping method for the shallow water equations on the sphere. We show the optimization gains and data structure reorganization that facilitates the performance improvements.

54 ENVIRONMENTAL SCIENCES↗

Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X–Y–U)-strip anode readout

The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X--Y--U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using simple standard PCB fabrication techniques. Capacitive-sharing (X--Y--U)-strip readout allows simultaneous measurement of the Cartesian coordinates x and y of the position of the particles together with a third coordinate u along the diagonal axis in a single readout PCB. This provides a powerful tool to address multiple-hit ambiguity and enable pattern recognition capabilities in moderate particle flux environment of collider or fixed target experiments in high energy physics HEP) and nuclear physics (NP). We present in this paper the performance of a 10 cm × 10 cm triple-GEM detector with capacitive-sharing (X--Y--U)-strip anode readout. Spatial resolutions of the order of $\sigma_{x}^{res}$ = 71.6 $\pm$ 0.8 $\mu$m for X-strips, $\sigma_{y}^{res}$ = 56.2 $\pm$ 0.9 $\mu$m for Y-strips and $\sigma_{u}^{res}$ = 75.2 $\pm$ 0.9 $\mu$m for U-strips have been obtained at a beam test at Thomas Jefferson National Accelerator Facility (Jefferson Lab). Modifications of the readout design of future prototypes to improve the spatial resolution and challenges in scaling to large-area MPGDs are discussed.

(X-Y-U) strip↗

4D-Imaging of the Lung: Reproducibility of Lesion Size and Displacement on Helical CT, MRI, and Cone Beam CT in a Ventilated Ex Vivo System

Purpose: Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). Methods and Materials: Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24x10{sup 2}/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution {approx}1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. Results: Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p < 0.05 vs. CT]; 1.47/1.28 [MRI vs. CT/CBCT p < 0.05]; 1.86/1.83 [CT vs. CBCT p < 0.05]). Interobserver-VC for lesion sizes were 2.54-4.47% (CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). Conclusions: Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distilling nanoscale heterogeneity of amorphous silicon using tip-enhanced Raman spectroscopy (TERS) via multiresolution manifold learning

Abstract Accurately identifying the local structural heterogeneity of complex, disordered amorphous materials such as amorphous silicon is crucial for accelerating technology development. However, short-range atomic ordering quantification and nanoscale spatial resolution over a large area on a-Si have remained major challenges and practically unexplored. We resolve phonon vibrational modes of a-Si at a lateral resolution of <60 nm by tip-enhanced Raman spectroscopy. To project the high dimensional TERS imaging to a two-dimensional manifold space and categorize amorphous silicon structure, we developed a multiresolution manifold learning algorithm. It allows for quantifying average Si-Si distortion angle and the strain free energy at nanoscale without a human-specified physical threshold. The multiresolution feature of the multiresolution manifold learning allows for distilling local defects of ultra-low abundance (< 0.3%), presenting a new Raman mode at finer resolution grids. This work promises a general paradigm of resolving nanoscale structural heterogeneity and updating domain knowledge for highly disordered materials.

36 MATERIALS SCIENCE↗

Spatial retarding field energy analyzer measurements downstream of a helicon double layer plasma

Spatial ion energy measurements using a retarding field energy analyzer are performed in the exhaust of a 0.30 mTorr, 250 W helicon double layer plasma to investigate the divergence of the argon ion beam formed by acceleration in the double layer. Various divergence angles are computed by considering the radial distribution of beam density; the average beam ion diverging by 9 deg. The efficiency at which momentum is imparted parallel to the longitudinal axis of the thruster is calculated to be 98%. The results show that a few centimeters downstream of the source, the beam ions do not follow the magnetic field lines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bayesian analysis of CCDM models

Creation of Cold Dark Matter (CCDM), in the context of Einstein Field Equations, produces a negative pressure term which can be used to explain the accelerated expansion of the Universe. In this work we tested six different spatially flat models for matter creation using statistical criteria, in light of SNe Ia data: Akaike Information Criterion (AIC), Bayesian Information Criterion (BIC) and Bayesian Evidence (BE). These criteria allow to compare models considering goodness of fit and number of free parameters, penalizing excess of complexity. We find that JO model is slightly favoured over LJO/ΛCDM model, however, neither of these, nor Γ = 3α H {sub 0} model can be discarded from the current analysis. Three other scenarios are discarded either because poor fitting or because of the excess of free parameters. A method of increasing Bayesian evidence through reparameterization in order to reducing parameter degeneracy is also developed.

79 ASTRONOMY AND ASTROPHYSICS↗

ACCELERATION, MAGNETIC FLUCTUATIONS, AND CROSS-FIELD TRANSPORT OF ENERGETIC ELECTRONS IN A SOLAR FLARE LOOP

Plasma turbulence is thought to be associated with various physical processes involved in solar flares, including magnetic reconnection, particle acceleration, and transport. Using RHESSI observations and the X-ray visibility analysis, we determine the spatial and spectral distributions of energetic electrons for a flare (GOES M3.7 class, 2002 April 14, 23:55 UT), which was previously found to be consistent with a reconnection scenario. It is demonstrated that because of the high density plasma in the loop, electrons have to be continuously accelerated about the loop apex of length {approx}2 x 10{sup 9} cm and width {approx}7 x 10{sup 8} cm. Energy-dependent transport of tens of keV electrons is observed to occur both along and across the guiding magnetic field of the loop. We show that the cross-field transport is consistent with the presence of magnetic turbulence in the loop, where electrons are accelerated, and estimate the magnitude of the field line diffusion coefficient for different phases of the flare. The energy density of magnetic fluctuations is calculated for given magnetic field correlation lengths and is larger than the energy density of the non-thermal electrons. The level of magnetic fluctuations peaks when the largest number of electrons is accelerated and is below detectability or absent at the decay phase. These hard X-ray observations provide the first observational evidence that magnetic turbulence governs the evolution of energetic electrons in a dense flaring loop and is suggestive of their turbulent acceleration.

79 ASTRONOMY AND ASTROPHYSICS↗

An efficient protocol for radiochromic film dosimetry combining calibration and measurement in a single scan

Purpose: Radiochromic film provides dose measurement at high spatial resolution, but often is not preferred for routine evaluation of patient-specific intensity modulated radiation therapy (IMRT) plans owing to ease-of-use factors. The authors have established an efficient protocol that combines calibration and measurement in a single scan and enables measurement results to be obtained in less than 30 min. This avoids complications due to postexposure changes in radiochromic film that delay the completion of a measurement, often for up to 24 h, in commonly used methods. In addition, the protocol addresses the accuracy and integrity of the measurement by eliminating environmental and interscan variability issues. Methods: The authors collected dose-response data from six production lots of Gafchromic EBT3 film and three production lots of EBT2 film at doses up to 480 cGy. In this work, the authors used seven different scanners of two different models-Epson 10000XL and V700; postexposure times before scanning from 30 min to 9 days; ambient temperatures for scanning spanning 11 Degree-Sign C; and two film orientations. Scanning was in 48-bit RGB format at 72 dpi resolution. Dose evaluation was conducted using a triple-channel dosimetry method. To evaluate the measurement protocol, patient specific IMRT and volumetric modulated arc therapy (VMAT) plans were exposed onto EBT3 films on a Varian Trilogy Linac. Film scanning was done following the protocol under a number of different conditions and the dose maps were analyzed to demonstrate the equivalence of results. Results: The results indicated that the dose-response data could be fit by a set of related rational functions leading to the description of a generic calibration curve. A simplified dosimetry protocol was established where dose-response data for a specific film lot, scanner, and scanning conditions could be derived from two films exposed to known doses. In most cases only one calibrated exposure was required since the dose for one of the films could be zero. Using the Gamma test criterion of 2%/2 mm to evaluate the measurements, similar passing rates ranging between about 95% and 99% for the fields studied were obtained from application films digitized under a variety of conditions all of them different than the conditions under which the calibration films were scanned. Conclusions: The authors have developed a simplified and efficient protocol to measure doses delivered by an IMRT or VMAT plan using only the patient film, one calibration film, one unexposed film, and applying a single scan to acquire a digital image for calculation and analysis. The simplification and timesaving offer a potential practical solution for using radiochromic film for routine treatment plan quality assurance without sacrificing spatial resolution for convenience.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-126: Respiratory Gating Quality Assurance: A Simple Method to Achieve Millisecond Temporal Resolution

Purpose: Low temporal latency between a gating on/off signal and a linac beam on/off during respiratory gating is critical for patient safety. Although, a measurement of temporal lag is recommended by AAPM Task Group 142 for commissioning and annual quality assurance, there currently exists no published method. Here we describe a simple, inexpensive, and reliable method to precisely measure gating lag at millisecond resolutions. Methods: A Varian Real-time Position Management™ (RPM) gating simulator with rotating disk was modified with a resistive flex sensor (Spectra Symbol) attached to the gating box platform. A photon diode was placed at machine isocenter. Output signals of the flex sensor and diode were monitored with a multichannel oscilloscope (Tektronix™ DPO3014). Qualitative inspection of the gating window/beam on synchronicity were made by setting the linac to beam on/off at end-expiration, and the oscilloscope's temporal window to 100 ms to visually examine if the on/off timing was within the recommended 100-ms tolerance. Quantitative measurements were made by saving the signal traces and analyzing in MatLab™. The on and off of the beam signal were located and compared to the expected gating window (e.g. 40% to 60%). Four gating cycles were measured and compared. Results: On a Varian TrueBeam™ STx linac with RPM gating software, the average difference in synchronicity at beam on and off for four cycles was 14 ms (3 to 30 ms) and 11 ms (2 to 32 ms), respectively. For a Varian Clinac™ 21EX the average difference at beam on and off was 127 ms (122 to 133 ms) and 46 ms (42 to 49 ms), respectively. The uncertainty in the synchrony difference was estimated at ±6 ms. Conclusion: This new gating QA method is easy to implement and allows for fast qualitative inspection and quantitative measurements for commissioning and TG-142 annual QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geophysical Methods for Stratigraphic Identification

The goal of this work is to identify geophysical methods that can be used to delineate (in 3D) a large-scale paleochannel that has been inferred to exist between the 200 West and 200 East Areas of the Hanford Site’s Central Plateau . This paleochannel is of particular importance because it will significantly impact flow and contaminant transport from 200 West to 200 East. Its high permeability can both accelerate contaminant transport and lower contaminant concentrations through spreading. Information about the spatial extent and structure of such features is needed to inform subsurface flow and contaminant transport models that support remedy decisions at Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗