Search NASA⌕ Search

SEARCH · Search NASA

Results for “standard package testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Qualification of an Additively Manufactured Irradiation Capsule for the High Flux Isotope Reactor

As part of the Advanced Materials and Manufacturing Technologies (AMMT) Program’s work package Component Manufacturing and Demonstrations from AM 316 SS, irradiation capsules have been additively manufactured (AM) from 316H stainless steel for insertion into the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The irradiation capsules (commonly referred to as “rabbits”) have been successfully designed, fabricated, pressure tested, qualified, and inserted into the HFIR for irradiation and post-irradiation evaluation. Each rabbit consists of an AM housing and two standard AM end caps. The design is simple and amenable to geometric and material customization. This demonstration helps pave the way for acceptance of AM safety-critical components for nuclear energy applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Significance Tests on Stack Sample Data

In October 2023, external assessors visiting LANL’s Rad-NESHAP team reviewed the annual source term documentation package for stack emissions. This document discusses how the team uses significance tests to determine whether or not a measurement represents an actual detection of emitted radioactive material. The significance tests used in the evaluation compare the measured sample result to the Minimum Detectable Activity (MDA) for the sample; to the uncertainty of that measurement; and to the mean blank sample for the same time period. The blank test uses the average blank plus 2-standard deviations (2σ) of the blank results as a comparison threshold for this final evaluation.

54 ENVIRONMENTAL SCIENCES↗

Ada and knowledge-based systems: A prototype combining the best of both worlds

A software architecture is described which facilitates the construction of distributed expert systems using Ada and selected knowledge based systems. This architecture was utilized in the development of a Knowledge-based Maintenance Expert System (KNOMES) prototype for the Space Station Mobile Service Center (MSC). The KNOMES prototype monitors a simulated data stream from MSC sensors and built-in test equipment. It detects anomalies in the data and performs diagnosis to determine the cause. The software architecture which supports the KNOMES prototype allows for the monitoring and diagnosis tasks to be performed concurrently. The basic concept of this software architecture is named ACTOR (Ada Cognitive Task ORganization Scheme). An individual ACTOR is a modular software unit which contains both standard data processing and artificial intelligence components. A generic ACTOR module contains Ada packages for communicating with other ACTORs and accessing various data sources. The knowledge based component of an ACTOR determines the role it will play in a system. In this prototype, an ACTOR will monitor the MSC data stream.

Brauer, David C.↗

Structural verification for GAS experiments

The purpose of this paper is to assist the Get Away Special (GAS) experimenter in conducting a thorough structural verification of its experiment structural configuration, thus expediting the structural review/approval process and the safety process in general. Material selection for structural subsystems will be covered with an emphasis on fasteners (GSFC fastener integrity requirements) and primary support structures (Stress Corrosion Cracking requirements and National Space Transportation System (NSTS) requirements). Different approaches to structural verifications (tests and analyses) will be outlined especially those stemming from lessons learned on load and fundamental frequency verification. In addition, fracture control will be covered for those payloads that utilize a door assembly or modify the containment provided by the standard GAS Experiment Mounting Plate (EMP). Structural hazard assessment and the preparation of structural hazard reports will be reviewed to form a summation of structural safety issues for inclusion in the safety data package.

Peden, Mark Daniel↗

NASA-STD-(I)-6016, Standard Materials and Processes Requirements for Spacecraft

This document is directed toward Materials and Processes (M&P) used in the design, fabrication, and testing of flight components for all NASA manned, unmanned, robotic, launch vehicle, lander, in-space and surface systems, and spacecraft program/project hardware elements. All flight hardware is covered by the M&P requirements of this document, including vendor designed, off-the-shelf, and vendor furnished items. Materials and processes used in interfacing ground support equipment (GSE); test equipment; hardware processing equipment; hardware packaging; and hardware shipment shall be controlled to prevent damage to or contamination of flight hardware.

Pedley, Michael↗

Obtaining a Special Administrative License Exemption to Ship the West Valley Melter Box - 16327

In order to ship the West Valley Melter Package (WVMP) package to support its disposal, the U.S. Department of Energy (DOE) requested a one-time shipment license exemption from the U.S. Nuclear Regulatory Commission (NRC). Based on content, the previously constructed WVMP, containing residual borosilicate glass and Low Density Cellular Concrete was shown to require a Type B Package. Therefore, Title 10 of the United States Code of Federal Regulations, Part 71 (10 CFR 71) required that radioactive releases under Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC) would remain less than 1 E-7 A{sub 2}/hour and 1 E-1 A{sub 2}/week, respectively. Although the NRC normal method for demonstrating conformance to the 10CFR71 requirement is through performance of leak rate testing per American National Standards Institute (ANSI) standard N14.5, the WVMP does not contain a pressure vessel; therefore, performance of leak rate testing was not applicable/possible. Instead, an alternate method, adapted from DOE Handbook 3010 was used to show that the maximum allowed 10 CFR 71 radionuclide release rates for NCT and HAC would not be exceeded. Summarizing the effort, this paper provides the technical synopsis for requesting the exemption. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact Studies and Cooperative Voltage Control for High PV Penetration

The drastically increasing penetration of photovoltaic (PV) has posed tremendous challenges in operation, control, and protection in distribution networks. The over-voltage issue is one of major concerns for extremely high PV penetration (e.g. 100%). It is critical to identify the most sensitive locations to high PV penetration and apply effective methods to mitigate the over-voltage issue. This paper introduced a novel greedy search algorithm to locate worst-case scenarios of over-voltage in both distributed and centralized PV configurations, as well as a cooperative voltage control method to mitigate over-voltage. The search algorithm has the computational advantage over existing stochastic approach and provides more insights in impact studies. The cooperative control method relies upon reactive power compensation to converge system voltage to a predefined value within standard limits. Moreover, a clustering strategy is applied to divide the network into several clusters, within which all nodes share information with neighboring nodes following a scalable communication architecture. The control algorithms and communication hierarchies presented in this paper have been implemented into OpenDSS to form the Multi Agent (MA) OpenDSS package, which has been made available to the reader. The effectiveness of developed methods are demonstrated through simulation studies on the IEEE 123-node test feeder under four different load levels.

Cooperative control↗

Gen 3 Particle Pilot Plant (G3P3) -- High-Temperature Particle System for Concentrating Solar Power (Phases 1 and 2)

The U.S. Department of Energy Solar Energy Technologies Office initiated the Generation 3 Concentrating Solar Power (CSP) program to achieve higher operating temperatures (>700 °C) to enable next-generation CSP high-temperature power cycles such as the supercritical CO 2 (sCO2) Brayton Cycle. Three teams were selected to pursue high-temperature gas, liquid, and solid pathways for the heat-transfer media. Phases 1 and 2, which lasted from 2018 – 2020, consisted of design, modeling, and testing activities to further de-risk each of the technologies and develop a design for construction, commissioning, and operation of a pilot-scale facility in Phase 3 (2021 – 2024). This report summarizes the activities in Phases 1 and 2 for the solid-particle pathway led by Sandia National Laboratories. In Phases 1 and 2, Sandia successfully de-risked key elements of the proposed Gen 3 Particle Pilot Plant (G3P3) by improving the design, operation, and performance of key particle component technologies including the receiver, storage bins, particle-to-sCO2 heat exchanger, particle lift, and data acquisition and controls. Modeling and testing of critical components have led to optimized designs that meet desired performance metrics. Detailed drawings, piping and instrumentation diagrams, and process flow diagrams were generated for the integrated system, and structural analyses of the assembled tower structure were performed to demonstrate compliance with relevant codes and standards. Instrumentation and control systems of key subsystems were also demonstrated. Together with Bridgers & Paxton, Bohannan Huston, and Sandia Facilities, we have completed a 100% G3P3 tower design package with stamped engineering drawings suitable for construction bid in Phase 3.

14 SOLAR ENERGY↗

Study of the Alsys implementation of the Catalogue of Interface Features and Options for the Ada language for 80386 Unix

A set of programs was written to test the functionality and performance of the Alsys Ada implementation of the Catalogue of Interface Features and Options (CIFO), a set of optional Ada packages for real-time applications. No problems were found with the task id, preemption control, or shared-data packages. Minor problems were found with the dispatching control, dynamic priority, events, non-waiting entry call, semaphore, and scheduling packages. The Alsys implementation is derived mostly from Release 2 of the CIFO standard, but includes some of the features of Release 3 and some modifications unique to Alsys. Performance measurements show that the semaphore and shared-data features are an order-of-magnitude faster than the same mechanisms using an Ada rendezvous. The non-waiting entry call is slightly faster than a standard rendezvous. The existence of errors in the implementation, the incompleteness of the documentation from the published standard impair the usefulness of this implementation. Despite those short-comings, the Alsys CIFO implementation might be of value in the development of real-time applications.

Gibson, James S.↗

Thermal Removal Of Tritium From Concrete And Soil To Reduce Groundwater Impacts

Legacy heavy-water moderator operations at the Savannah River Site (SRS) have resulted in the contamination of equipment pads, building slabs, and surrounding soil with tritium. At the time of discovery the tritium had impacted the shallow (< 3-m) groundwater at the facility. While tritium was present in the groundwater, characterization efforts determined that a significant source remained in a concrete slab at the surface and within the associated vadose zone soils. To prevent continued long-term impacts to the shallow groundwater a CERCLA non-time critical removal action for these source materials was conducted to reduce the leaching of tritium from the vadose zone soils and concrete slabs. In order to minimize transportation and disposal costs, an on-site thermal treatment process was designed, tested, and implemented. The on-site treatment consisted of thermal detritiation of the concrete rubble and soil. During this process concrete rubble was heated to a temperature of 815 deg C (1,500 deg F) resulting in the dehydration and removal of water bound tritium. During heating, tritium contaminated soil was used to provide thermal insulation during which it&#x27;s temperature exceeded 100 deg C (212 deg F), causing drying and removal of tritium. The thermal treatment process volatiles the water bound tritium and releases it to the atmosphere. The released tritium was considered insignificant based upon Clean Air Act Compliance Package (CAP88) analysis and did not exceed exposure thresholds. A treatability study evaluated the effectiveness of this thermal configuration and viability as a decontamination method for tritium in concrete and soil materials. Post treatment sampling confirmed the effectiveness at reducing tritium to acceptable waste site specific levels. With American Recovery and Reinvestment Act (ARRA) funding three additional treatment cells were assembled utilizing commercial heating equipment and common construction materials. This provided a total of four units to batch treat concrete rubble and soil. Post treatment sampling verified that the activity in the treated soil and concrete met the treatment standards for each medium which allowed the treated concrete rubble and soil to be disposed of on site as backfill. During testing and operations a total of 1,261-m{sup 3} (1,650-yd{sup 3}) of contaminated concrete and soils were treated with an actual incurred cost of $3,980,000. This represents a unit treatment cost of $3,156/m{sup 3} ($2,412/yd{sup 3}). In 2011 the project was recognized with an e-Star Sustainability Award by DOE&#x27;s Office of Environmental Management.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Packaging and Modular Control of Thermoelectric Clothes Dryer, With Performance Evaluation

This paper provides an overview of a thermoelectric heat pump clothes dryer which was developed with the aim of reducing the significant primary energy consumption attributed to residential electric clothes drying in the United States (623 TBtu/yr). The use of thermoelectric modules in place of the conventional electric resistance heater resulted in a 40% reduction in the energy consumption of the system, compared to the minimum energy efficiency standard. This was achieved for the first time for a standard test load of 8.45 lb, using a clothes dryer prototype with a thermoelectric heat pump module as the sole heating mechanism. The current experimental prototype was developed after extensive modeling, system design and control optimization, and experimental system-level evaluation of control parameters. The demonstration of improved energy consumption has laid the foundation for future development of this technology.

Patel, Viral↗

Northwest Energy Efficient Manufactured Housing Program Specification Development

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House, Hood River, Oregon (Fact Sheet)

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50% (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Whole-House Solutions Case Study: Hood River Passive House

The Hood River Passive Project was developed by Root Design Build of Hood River Oregon using the Passive House Planning Package (PHPP) to meet all of the requirements for certification under the European Passive House standards. The Passive House design approach has been gaining momentum among residential designers for custom homes and BEopt modeling indicates that these designs may actually exceed the goal of the U.S. Department of Energy's (DOE) Building America program to "reduce home energy use by 30%-50%" (compared to 2009 energy codes for new homes). This report documents the short term test results of the Shift House and compares the results of PHPP and BEopt modeling of the project. The design includes high R-Value assemblies, extremely tight construction, high performance doors and windows, solar thermal DHW, heat recovery ventilation, moveable external shutters and a high performance ductless mini-split heat pump. Cost analysis indicates that many of the measures implemented in this project did not meet the BA standard for cost neutrality. The ductless mini-split heat pump, lighting and advanced air leakage control were the most cost effective measures. The future challenge will be to value engineer the performance levels indicated here in modeling using production based practices at a significantly lower cost.

BA-PIRC↗

Thermal Removal of Tritium from Concrete and Soil to Reduce Groundwater Impacts - 13197

Legacy heavy-water moderator operations at the Savannah River Site (SRS) have resulted in the contamination of equipment pads, building slabs, and surrounding soil with tritium. At the time of discovery the tritium had impacted the shallow (< 3-m) groundwater at the facility. While tritium was present in the groundwater, characterization efforts determined that a significant source remained in a concrete slab at the surface and within the associated vadose zone soils. To prevent continued long-term impacts to the shallow groundwater a CERCLA non-time critical removal action for these source materials was conducted to reduce the leaching of tritium from the vadose zone soils and concrete slabs. In order to minimize transportation and disposal costs, an on-site thermal treatment process was designed, tested, and implemented. The on-site treatment consisted of thermal detritiation of the concrete rubble and soil. During this process concrete rubble was heated to a temperature of 815 deg. C (1,500 deg. F) resulting in the dehydration and removal of water bound tritium. During heating, tritium contaminated soil was used to provide thermal insulation during which it's temperature exceeded 100 deg. C (212 deg. F), causing drying and removal of tritium. The thermal treatment process volatiles the water bound tritium and releases it to the atmosphere. The released tritium was considered insignificant based upon Clean Air Act Compliance Package (CAP88) analysis and did not exceed exposure thresholds. A treatability study evaluated the effectiveness of this thermal configuration and viability as a decontamination method for tritium in concrete and soil materials. Post treatment sampling confirmed the effectiveness at reducing tritium to acceptable waste site specific levels. With American Recovery and Reinvestment Act (ARRA) funding three additional treatment cells were assembled utilizing commercial heating equipment and common construction materials. This provided a total of four units to batch treat concrete rubble and soil. Post treatment sampling verified that the activity in the treated soil and concrete met the treatment standards for each medium which allowed the treated concrete rubble and soil to be disposed of on-site as backfill. During testing and operations a total of 1,261-m{sup 3} (1,650-yd{sup 3}) of contaminated concrete and soils were treated with an actual incurred cost of $3,980,000. This represents a unit treatment cost of $3,156/m{sup 3} ($2,412/yd{sup 3}). In 2011 the project was recognized with an e-Star Sustainability Award by DOE's Office of Environmental Management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗