At least 307 records · Page 17

Invited Article: Relation between electric and magnetic field structures and their proton-beam images

Proton imaging is commonly used to reveal the electric and magnetic fields that are found in high energy density plasmas. Presented here is an analysis of this technique that is directed towards developing additional insight into the underlying physics. This approach considers: formation of images in the limits of weak and strong intensity variations; caustic formation and structure; image inversion to obtain line-integrated field characteristics; direct relations between images and electric or magnetic field structures in a plasma; imaging of sharp features such as Debye sheaths and shocks. Limitations on spatial and temporal resolution are assessed, and similarities with optical shadowgraphy are noted. Synthetic proton images are presented to illustrate the analysis. These results will be useful for quantitatively analyzing experimental proton imaging data and verifying numerical codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two worlds collide: Image analysis methods for quantifying structural variation in cluster molecular dynamics

Inspired by methods of remote sensing image analysis, we analyze structural variation in cluster molecular dynamics (MD) simulations through a unique application of the principal component analysis (PCA) and Pearson Correlation Coefficient (PCC). The PCA analysis characterizes the geometric shape of the cluster structure at each time step, yielding a detailed and quantitative measure of structural stability and variation at finite temperature. Our PCC analysis captures bond structure variation in MD, which can be used to both supplement the PCA analysis as well as compare bond patterns between different cluster sizes. Relying only on atomic position data, without requirement for a priori structural input, PCA and PCC can be used to analyze both classical and ab initio MD simulations for any cluster composition or electronic configuration. Taken together, these statistical tools represent powerful new techniques for quantitative structural characterization and isomer identification in cluster MD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method of acquiring an image from an optical structure having pixels with dedicated readout circuits

An imaging device formed as a monolithic complementary metal oxide semiconductor integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate, a readout circuit including at least an output field effect transistor formed in the substrate, and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node connected to the output transistor and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node.

Fossum, Eric R.↗

Bouguer images of the North American craton and its structural evolution

Digital image processing techniques have been used to generate Bouguer images of the North American craton that diplay more of the granularity inherent in the data as compared with existing contour maps. A dominant NW-SE linear trend of highs and lows can be seen extending from South Dakota, through Nebraska, and into Missouri. The structural trend cuts across the major Precambrian boundary in Missouri, separating younger granites and rhyolites from older sheared granites and gneisses. This trend is probably related to features created during an early and perhaps initial episode of crustal assembly by collisional processes. The younger granitic materials are probably a thin cover over an older crust.

Arvidson, R. E.↗

Quantification of silicon carbide grain structure in TRISO fuel by BSE image analysis

The grain structure of the silicon carbide (SiC) layer in tristructural-isotropic (TRISO) fuels has commonly been qualified in fuel specifications based on a qualitative comparison to visual standards to ensure undesirable microstructure are not produced. This approach is inherently dependent on subjective judgement and provides limited data for analysis or comparison. An alternative method to rapidly quantify (i.e., provide a numeric measure of) the grain structure of the SiC layer in TRISO fuels has been developed. This method relies on the identification of silicon carbide grain boundaries based on brightness variation in backscattered electron (BSE) images through the application of automated image processing algorithms. The speed with which the requisite BSE imaging and analysis may be completed enables the practical use of this method on an industrial scale as a part of qualifying TRISO fuel to meet a given specification on silicon carbide grain structure, which is an important parameter for TRISO fuel performance. The method is benchmarked by comparison to prior Electron-Backscattered Diffraction (EBSD) results for TRISO particles from the Advanced Gas Reactor (AGR) program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Spatial vision processes: From the optical image to the symbolic structures of contour information

The significance of machine and natural vision is discussed together with the need for a general approach to image acquisition and processing aimed at recognition. An exploratory scheme is proposed which encompasses the definition of spatial primitives, intrinsic image properties and sampling, 2-D edge detection at the smallest scale, the construction of spatial primitives from edges, and the isolation of contour information from textural information. Concepts drawn from or suggested by natural vision at both perceptual and physiological levels are relied upon heavily to guide the development of the overall scheme. The scheme is intended to provide a larger context in which to place the emerging technology of detector array focal-plane processors. The approach differs from many recent efforts in edge detection and image coding by emphasizing smallest scale edge detection as a foundation for multi-scale symbolic processing while diminishing somewhat the importance of image convolutions with multi-scale edge operators. Cursory treatments of information theory illustrate that the direct application of this theory to structural information in images could not be realized.

Jobson, Daniel J.↗

X-ray Fluorescence Nanotomography of Single Bacteria with a Sub-15 nm Beam

Abstract X-ray Fluorescence (XRF) microscopy is a growing approach for imaging the trace element concentration, distribution, and speciation in biological cells at the nanoscale. Moreover, three-dimensional nanotomography provides the added advantage of imaging subcellular structure and chemical identity in three dimensions without the need for staining or sectioning of cells. To date, technical challenges in X-ray optics, sample preparation, and detection sensitivity have limited the use of XRF nanotomography in this area. Here, XRF nanotomography was used to image the elemental distribution in individual E . coli bacterial cells using a sub-15 nm beam at the Hard X-ray Nanoprobe beamline (HXN, 3-ID) at NSLS-II. These measurements were simultaneously combined with ptychography to image structural components of the cells. The cells were embedded in small (3–20 µm) sodium chloride crystals, which provided a non-aqueous matrix to retain the three-dimensional structure of the E . coli while collecting data at room temperature. Results showed a generally uniform distribution of calcium in the cells, but an inhomogeneous zinc distribution, most notably with concentrated regions of zinc at the polar ends of the cells. This work demonstrates that simultaneous two-dimensional ptychography and XRF nanotomography can be performed with a sub-15 nm beam size on unfrozen biological cells to co-localize elemental distribution and nanostructure simultaneously.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical Inference Over Persistent Homology Predicts Fluid Flow in Porous Media

Here, we statistically infer fluid flow and transport properties of porous materials based on their geometry and connectivity, without the need for detailed We summarize structure by persistent homology and then determines the similarity of structures using image analysis and statistics. Longer term, this may enable quick and automated categorization of rocks into known archetypes. We first compute persistent homology of binarized 3D images of material subvolume samples. The persistence parameter is the signed Euclidean distance from inferred material interfaces, which captures the distribution of sizes of pores and grains. Each persistence diagram is converted into an image vector. Here, we infer structural similarity by calculating image similarity. For each image vector, we compute principal components to extract features. We fit statistical models to features estimates material permeability, tortuosity, and anisotropy. We develop a Structural SIMilarity index to determine statistical representative elementary volumes.

36 MATERIALS SCIENCE↗

Structural integrity--Searching the key factor to suppress the voltage fade of Li-rich layered cathode materials through 3D X-ray imaging and spectroscopy techniques

Li-rich layered materials are important cathode compounds used in commercial lithium ion batteries, which, however, suffers from some drawbacks including the so-called voltage fade upon electrochemical cycling. Here, our study employs novel transmission X-ray microscopy to investigate the electrochemical reaction induced morphological and chemical changes in the Li-rich Li 2 Ru 0.5 Mn 0.5 O 3 cathode particles at the meso to nano scale. We performed combined X-ray spectroscopy, diffraction and microscopy experiments to systematically study this cathode material's evolution upon cycling as well as to establish a comprehensive understanding of the structural origin of capacity fade through 2D and 3D fine length scale morphology and heterogeneity change of this material. This work suggests that atomic manipulation (e.g. doping, substitution etc.) or nano engineering (e.g. nano-sizing, heterogeneous structure) are important strategies to mitigate the internal strain and defects induced by extensive lithium insertion/extraction. It also shows that maintaining the structural integrity is the key in designing and synthesizing lithium-rich layered materials with better cycle stability.

25 ENERGY STORAGE↗

Imaging of cochlear tissue with a grating interferometer and hard X-rays

This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X-rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X-ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low-absorption contrast have been visualized using in-line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high-photon flux (>10{sup 12} photons/s) at high-photon energies (5-70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20-{micro}m thick tissue slice induces a phase shift between 1/3{pi} and 2/3{pi}.

43 PARTICLE ACCELERATORS↗

Multiscale vector fields for image pattern recognition

A uniform processing framework for low-level vision computing in which a bank of spatial filters maps the image intensity structure at each pixel into an abstract feature space is proposed. Some properties of the filters and the feature space are described. Local orientation is measured by a vector sum in the feature space as follows: each filter's preferred orientation along with the strength of the filter's output determine the orientation and the length of a vector in the feature space; the vectors for all filters are summed to yield a resultant vector for a particular pixel and scale. The orientation of the resultant vector indicates the local orientation, and the magnitude of the vector indicates the strength of the local orientation preference. Limitations of the vector sum method are discussed. Investigations show that the processing framework provides a useful, redundant representation of image structure across orientation and scale.

Low, Kah-Chan↗

Device and method for constructing and displaying high quality images from imaging data by transforming a data structure utilizing machine learning techniques

Constructing a computer image from raw imaging data or encoded imaging data by transforming a first data structure in which the raw imaging data or the encoded imaging data is stored into a second data structure storing reorganized imaging data. The raw imaging data or the encoded imaging data is received, stored in the first data structure. The computer reorganizes the raw imaging data or the encoded imaging data into the reorganized data and stores the reorganized data in the second data structure, which is a multi-dimensional array having subarrays containing local information needed by a convolutional neural network for processing the reorganized data. Other portions of the multi-dimensional array store other portions of the raw imaging data or the encoded imaging data. The computer also processes the reorganized data using the convolutional neural network to construct the image, whereby a constructed image is formed.

Korbin, John P.↗

A novel imaging technique for measuring kinematics of light-weight flexible structures

A new imaging algorithm is proposed to capture the kinematics of flexible, thin, light structures including frequencies and motion amplitudes for real time analysis. The studied case is a thin flexible beam that is preset at different angles of attack in a wind tunnel. As the angle of attack is increased beyond a critical value, the beam was observed to undergo a static deflection that is ensued by limit cycle oscillations. Imaging analysis of the beam vibrations shows that the motion consists of a superposition of the bending and torsion modes. The proposed algorithm was able to capture the oscillation amplitudes as well as the frequencies of both bending and torsion modes. The analysis results are validated through comparison with measurements from a piezoelectric sensor that is attached to the beam at its root.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ultraviolet Imaging Telescope ultraviolet images - Large-scale structure, H II regions, and extinction in M81

The study employs UV images of M81 obtained by the Ultraviolet Imaging Telescope (UIT) during the December 1990 Astro-1 spacelab mission to determine 2490- and 1520-A fluxes from 46 H II regions and global surface brightness profiles. Comparison photometry in the V band is obtained from a ground-based CCD image. UV radial profiles show bulge and exponential disk components, with a local decrease in disk surface brightness inside the inner Lindblad Resonance about 4 arcmin from the nucleus. The V profile shows typical bulge plus exponential disk structure, with no local maximum in the disk. There is little change of UV color across the disk, although there is a strong gradient in the bulge. Observed m152-V colors of the H II regions are consistent with model spectra for young clusters, after dereddening using Av determined from m249-V and the Galactic extinction curve. The value of Av, so determined, is 0.4 mag greater on the average than Av derived from radio continuum and H-alpha fluxes.

Hill, Jesse K.↗

Optimizing a low-energy electron diffraction spin-polarization analyzer for imaging of magnetic surface structures

A newly designed scanning electron microscope with polarization analysis (SEMPA or spin-SEM) for the acquisition of magnetic images is presented. Core component is the spin detector, based on the scattering of low-energy electrons at a W(100) surface in ultrahigh vacuum. The instrument has been optimized with respect to ease of handling and efficiency. The operation and performance of a general low-energy electron diffraction (LEED) detector for SEMPA have been modeled in order to find the optimum operating parameters and to predict the obtainable image asymmetry. Based on the energy dependence of the secondary electron polarization and intensity, the detector output is simulated. For our instrument with optimized performance we demonstrate experimentally 8.6% polarization asymmetry in the domain structure of an iron whisker. This corresponds to 17.2% image contrast, in excellent agreement with the predicted simulated value. A contrast to noise ratio of 27 is achieved at 5 ms acquisition time per pixel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A discrepancy within primate spatial vision and its bearing on the definition of edge detection processes in machine vision

The visual perception of form information is considered to be based on the functioning of simple and complex neurons in the primate striate cortex. However, a review of the physiological data on these brain cells cannot be harmonized with either the perceptual spatial frequency performance of primates or the performance which is necessary for form perception in humans. This discrepancy together with recent interest in cortical-like and perceptual-like processing in image coding and machine vision prompted a series of image processing experiments intended to provide some definition of the selection of image operators. The experiments were aimed at determining operators which could be used to detect edges in a computational manner consistent with the visual perception of structure in images. Fundamental issues were the selection of size (peak spatial frequency) and circular versus oriented operators (or some combination). In a previous study, circular difference-of-Gaussian (DOG) operators, with peak spatial frequency responses at about 11 and 33 cyc/deg were found to capture the primary structural information in images. Here larger scale circular DOG operators were explored and led to severe loss of image structure and introduced spatial dislocations (due to blur) in structure which is not consistent with visual perception. Orientation sensitive operators (akin to one class of simple cortical neurons) introduced ambiguities of edge extent regardless of the scale of the operator. For machine vision schemes which are functionally similar to natural vision form perception, two circularly symmetric very high spatial frequency channels appear to be necessary and sufficient for a wide range of natural images. Such a machine vision scheme is most similar to the physiological performance of the primate lateral geniculate nucleus rather than the striate cortex.

Jobson, Daniel J.↗

X-ray absorbing structures in the Yohkoh images of the corona

Filaments, flare sprays, prominences and 'post-flare' loops are familiar to H alpha observers in their frequent appearances 'in absorption', dark against the chromospheric background or plages. Observations of the X-ray corona are generally interpreted as due to emission via optically thin thermal bremsstrahlung. Several cases of X-ray coronal structures in Yohkoh images, due to high opacity, absorbing matter in coronograph loops, are presented. The presence of the absorbing matter, mixed with emitting matter, complicates inference of physical parameters such as emission measures in X-ray sources. In the case of well defined features, absorption provides an opportunity to infer density. Quantitative estimates of the attenuation due to the absorption in example features are presented.