Search NASA⌕ Search

SEARCH · Search NASA

Results for “synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Theory of Microwave Instability and Coherent Synchrotron Radiation in Electron Storage Rings

Bursting of coherent synchrotron radiation has been observed and in fact used to generate THz radiation in many electron storage rings. In order to understand and control the bursting, we return to the study of the microwave instability. In this paper, we will report on the theoretical understanding, including recent developments, of the microwave instability in electron storage rings. The historical progress of the theories will be surveyed, starting from the dispersion relation of coasting beams, to the work of Sacherer on a bunched beam, and ending with the Oide and Yokoya method of discretization. This theoretical survey will be supplemented with key experimental results over the years. Finally, we will describe the recent theoretical development of utilizing the Laguerre polynomials in the presence of potential-well distortion. This self-consistent method will be applied to study the microwave instability driven the impedances due to the coherent synchrotron radiation. Over the past quarter century, there has been steady progress toward smaller transverse emittances in electron storage rings used for synchrotron light sources, from tens of nm decades ago to the nm range recently. In contrast, there is not much progress made in the longitudinal plane. For an electron bunch in a typical ring, its relative energy spread {sigma}{sub {delta}} remains about 10{sup -3} and its length {sigma}{sub z} is still in between 5 mm to 10 mm. Now the longitudinal emittance ({sigma}{sub {delta}}{sigma}{sub z}) becomes a factor of thousand larger than those in the transverse dimensions. In this paper, we will address questions of: How short a bunch can be? What is the fundamental limit? If there is a limit, is there any mitigation method? Since the synchrotron radiation is so fundamental in electron storage rings, let us start with the coherent synchrotron radiation (CSR).

43 PARTICLE ACCELERATORS↗

Synchrotron Light Options at Super-B

Super-B is a planned asymmetric high luminosity e{sup +}e{sup -} collider at the {Upsilon}(4S) resonance as PEP-II and KEKB, to be built in Italy. The Super-B High (HER, 7 GeV) and Low (LER, 4 GeV) Energy beams characteristics are comparable to NSLS-II and other state of the art synchrotron light sources. This suggests the use of this facility, either parasitically or in dedicated runs, as light source. In this paper we compare the characteristics of the synchrotron light generated at Super-B with existing, in construction and proposed facilities. We investigate different schemes to incorporate the generation of synchrotron radiation in the collider lattice design and look at different beam line layouts for users. In the past high energy particle colliders were designed to collide as many particle as possible. This was done by maximizing the beam current, using relative large emittances and squeezing the beam at the interaction point. During the operation of PEP II the limits of both raising the beam currents and squeezing the beam were experienced. Therefore the optics was modified to lower emittance. The successful test of the 'large Piwinski angle' and crab waist scheme, with extremely low design emittances, at the DAPHNE collider at Frascati made it the design choice for Super-B. Both HER and LER have been designed to meet these requirements and the design parameters relevant to our study, are shown in Table 1. As comparison the design parameters from NSLS II and other state of the art synchrotron light sources have been added to this table. From these parameters it is obvious that synchrotron radiation generated from both HER and LER is comparable to this last generation sources.

43 PARTICLE ACCELERATORS↗

SYNCHROTRON EMISSION FROM VERY HIGH ENERGY GAMMA-RAY-INDUCED PAIR CASCADES IN ACTIVE GALACTIC NUCLEUS ENVIRONMENTS

The discovery of very high energy (VHE; E > 100 GeV) {gamma}-ray emission from intermediate- and low-frequency-peaked blazars suggests that {gamma}{gamma} absorption and pair cascading might occur in these objects. In previous papers, we investigated the Compton emission from VHE {gamma}-ray-induced pair cascades, deflected by moderate magnetic fields, in a largely model-independent way, and demonstrated that this emission can explain the Fermi fluxes and spectra of the radio galaxies Cen A and NGC 1275. In this paper, we describe a generalization of our Monte Carlo cascade code to include the angle-dependent synchrotron output from the cascades, allowing for the application to situations with non-negligible magnetic fields, leading to potentially observable synchrotron signatures, but still not dominating the radiative energy loss of cascade particles. We confirm that the synchrotron radiation from the cascades in NGC 1275 and Cen A is negligible for the parameters used in our previous works. We demonstrate that the magnetic field cannot be determined from a fit of the cascade emission to the {gamma}-ray spectrum alone, and the degeneracy can only be lifted if the synchrotron emission from the cascades is observed as well. We illustrate this fact with the example of NGC 1275. We point out that the cascade synchrotron emission may produce spectral features in the same energy range in which the big blue bump is observed in the spectral energy distributions of several blazars, and may make a non-negligible contribution to this feature. We illustrate this idea with the example of 3C 279.

79 ASTRONOMY AND ASTROPHYSICS↗

GAMMA-RAY LOUDNESS, SYNCHROTRON PEAK FREQUENCY, AND PARSEC-SCALE PROPERTIES OF BLAZARS DETECTED BY THE FERMI LARGE AREA TELESCOPE

The parsec-scale radio properties of 232 active galactic nuclei, most of which are blazars, detected by the Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope have been observed contemporaneously by the Very Long Baseline Array (VLBA) at 5 GHz. Data from both the first 11 months (1FGL) and the first 2 years (2FGL) of the Fermi mission were used to investigate these sources' {gamma}-ray properties. We use the ratio of the {gamma}-ray-to-radio luminosity as a measure of {gamma}-ray loudness. We investigate the relationship of several radio properties to {gamma}-ray loudness and to the synchrotron peak frequency. There is a tentative correlation between {gamma}-ray loudness and synchrotron peak frequency for BL Lac objects in both 1FGL and 2FGL, and for flat-spectrum radio quasars (FSRQs) in 2FGL. We find that the apparent opening angle tentatively correlates with {gamma}-ray loudness for FSRQs, but only when we use the 2FGL data. We also find that the total VLBA flux density correlates with the synchrotron peak frequency for BL Lac objects and FSRQs. The core brightness temperature also correlates with synchrotron peak frequency, but only for the BL Lac objects. The low-synchrotron-peaked (LSP) BL Lac object sample shows indications of contamination by FSRQs which happen to have undetectable emission lines. There is evidence that the LSP BL Lac objects are more strongly beamed than the rest of the BL Lac object population.

79 ASTRONOMY AND ASTROPHYSICS↗

CONSTRAINTS ON THE SYNCHROTRON EMISSION MECHANISM IN GAMMA-RAY BURSTS

We reexamine the general synchrotron model for gamma-ray bursts' (GRBs') prompt emission and determine the regime in the parameter phase space in which it is viable. We characterize a typical GRB pulse in terms of its peak energy, peak flux, and duration and use the latest Fermi observations to constrain the high-energy part of the spectrum. We solve for the intrinsic parameters at the emission region and find the possible parameter phase space for synchrotron emission. Our approach is general and it does not depend on a specific energy dissipation mechanism. Reasonable synchrotron solutions are found with energy ratios of 10{sup -4} < {epsilon}{sub B}/{epsilon}{sub e} < 10, bulk Lorentz factor values of 300 < {Gamma} < 3000, typical electrons' Lorentz factor values of 3 Multiplication-Sign 10{sup 3} < {gamma}{sub e} < 10{sup 5}, and emission radii of the order 10{sup 15} cm < R < 10{sup 17} cm. Most remarkable among those are the rather large values of the emission radius and the electron's Lorentz factor. We find that soft (with peak energy less than 100 keV) but luminous (isotropic luminosity of 1.5 Multiplication-Sign 10{sup 53}) pulses are inefficient. This may explain the lack of strong soft bursts. In cases when most of the energy is carried out by the kinetic energy of the flow, such as in the internal shocks, the synchrotron solution requires that only a small fraction of the electrons are accelerated to relativistic velocities by the shocks. We show that future observations of very high energy photons from GRBs by CTA could possibly determine all parameters of the synchrotron model or rule it out altogether.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial variations in the spectral index of polarized synchrotron emission in the 9 yr WMAP sky maps

We estimate the spectral index, β, of polarized synchrotron emission as observed in the 9 yr Wilkinson Microwave Anisotropy Probe sky maps using two methods, linear regression ({sup T}-T plot{sup )} and maximum likelihood. We partition the sky into 24 disjoint sky regions and evaluate the spectral index for all polarization angles between 0° and 85° in steps of 5°. Averaging over polarization angles, we derive a mean spectral index of β{sup all-sky} = –2.99 ± 0.01 in the frequency range of 23-33 GHz. We find that the synchrotron spectral index steepens by 0.14 from low to high Galactic latitudes, in agreement with previous studies, with mean spectral indices of β{sup plane} = –2.98 ± 0.01 and β{sup high-lat} = –3.12 ± 0.04. In addition, we find a significant longitudinal variation along the Galactic plane with a steeper spectral index toward the Galactic center and anticenter than toward the Galactic spiral arms. This can be well modeled by an offset sinusoidal, β(l) = –2.85 + 0.17sin (2l – 90°). Finally, we study synchrotron emission in the BICEP2 field, in an attempt to understand whether the claimed detection of large-scale B-mode polarization could be explained in terms of synchrotron contamination. Adopting a spectral index of β = –3.12, typical for high Galactic latitudes, we find that the most likely bias corresponds to about 2% of the reported signal (r = 0.003). The flattest index allowed by the data in this region is β = –2.5, and under the assumption of a straight power-law frequency spectrum, we find that synchrotron emission can account for at most 20% of the reported BICEP2 signal.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron self-Compton emission from the Crab and other pulsars

Results of a simulation of synchrotron self-Compton (SSC) emission from a rotation-powered pulsar are presented. The radiating particles are assumed to be both accelerated primary electrons and a spectrum of electron–positron pairs produced in cascades near the polar cap. They follow trajectories in a slot gap using 3D force-free magnetic field geometry, gaining pitch angles through resonant cyclotron absorption of radio photons, radiating and scattering synchrotron emission at high altitudes out to and beyond the light cylinder. Full angular dependence of the synchrotron photon density is simulated in the scattering and all processes are treated in the inertial observer frame. Spectra for the Crab and Vela pulsars as well as two energetic millisecond pulsars, B1821–24 and B1937+21, are simulated using this model. The simulation of the Crab pulsar radiation can reproduce both the flux level and the shape of the observed optical to hard X-ray emission assuming a pair multiplicity of M{sub +}=3×10{sup 5}, as well as the very-high-energy emission above 50 GeV detected by MAGIC and VERITAS, with both the synchrotron and SSC components reflecting the shape of the pair spectrum. Simulations of Vela, B1821−24, and B1937+21, for M{sub +} up to 10{sup 5}, do not produce pair SSC emission that is detectable by current telescopes, indicating that only Crab-like pulsars produce significant SSC components. The pair synchrotron emission matches the observed X-ray spectrum of the millisecond pulsars, and the predicted peak of this emission at 1–10 MeV would be detectable with planned Compton telescopes.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental and synthetic measurements of polarized synchrotron emission from runaway electrons in Alcator C-Mod

This paper presents the first experimental analysis of polarized synchrotron emission from relativistic runaway electrons (REs) in a tokamak plasma. Importantly, we show that the polarization information of synchrotron radiation can be used to diagnose spatially-localized RE pitch angle distributions. Synchrotron-producing REs were generated during low density, Ohmic, diverted plasma discharges in the Alcator C-Mod tokamak. The ten-channel motional Stark effect diagnostic was used to measure spatial profiles of the polarization angle θ pol and the fraction f pol of detected light that was linearly-polarized. Spatial transitions in θ pol of 90° —from horizontal to vertical polarization and vice versa—are observed in experimental data and are well-explained by the gyro-motion of REs and high directionality of synchrotron radiation. Here polarized synchrotron emission is modeled with the synthetic diagnostic Soft; its output Green's (or detector response) functions reveal a critical RE pitch angle at which θ pol flips by 90° and f pol is minimal. Using Soft, we determine the dominant RE pitch angle which reproduces measured θ pol and f pol values. The spatiotemporal evolutions of θ pol and f pol are explored in detail for one C-Mod discharge. For channels viewing REs near the magnetic axis and flux surfaces q = 1 and 4/3, disagreements between synthetic and experimental signals suggest that the sawtooth instability may be influencing RE dynamics. Furthermore, other sources of pitch angle scattering, not considered in this analysis, could help explain discrepancies between simulation and experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A UNIFORM CORRELATION BETWEEN SYNCHROTRON LUMINOSITY AND DOPPLER FACTOR IN GAMMA-RAY BURSTS AND BLAZARS: A HINT OF SIMILAR INTRINSIC LUMINOSITIES?

We compile 23 gamma-ray bursts (GRBs) and 21 blazars with estimated Doppler factors, and the Doppler factors of GRBs are estimated from their Lorentz factors by assuming their jet viewing angles {theta} {yields} 0{sup 0}. Using the conventional assumption that the prompt emission of GRBs is dominated by the synchrotron radiation, we calculate the synchrotron luminosity of GRBs from their total isotropic energy and burst duration. Intriguingly, we discover a uniform correlation between the synchrotron luminosity and Doppler factor, L{sub syn}{proportional_to}D{sup 3.1}, for GRBs and blazars, which suggests that they may share some similar jet physics. One possible reason is that GRBs and blazars have, more or less, similar intrinsic synchrotron luminosities and both of them are strongly enhanced by the beaming effect. After Doppler and redshift correction, we find that the intrinsic peak energy of the GRBs ranges from 0.1 to 3 keV with a typical value of 1 keV. We further correct the beaming effect for the observed luminosity of GRBs and find that a positive correlation exists between the intrinsic synchrotron luminosity and peak energy for GRBs, which is similar to that of blazars. Our results suggest that both the intrinsic positive correlation and the beaming effect may be responsible for the observed tight correlation between the isotropic energy and the peak energy in GRBs (the so-called Amati relation).

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute x-ray dosimetry on a synchrotron medical beam line with a graphite calorimeter

Purpose: The absolute dose rate of the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter. The calorimetry results were compared to measurements from the existing free-air chamber, to provide a robust determination of the absolute dose in the synchrotron beam and provide confidence in the first implementation of a graphite calorimeter on a synchrotron medical beam line. Methods: The graphite calorimeter has a core which rises in temperature when irradiated by the beam. A collimated x-ray beam from the synchrotron with well-defined edges was used to partially irradiate the core. Two filtration sets were used, one corresponding to an average beam energy of about 80 keV, with dose rate about 50 Gy/s, and the second filtration set corresponding to average beam energy of 90 keV, with dose rate about 20 Gy/s. The temperature rise from this beam was measured by a calibrated thermistor embedded in the core which was then converted to absorbed dose to graphite by multiplying the rise in temperature by the specific heat capacity for graphite and the ratio of cross-sectional areas of the core and beam. Conversion of the measured absorbed dose to graphite to absorbed dose to water was achieved using Monte Carlo calculations with the EGSnrc code. The air kerma measurements from the free-air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. Results: Absolute measurements of the IMBL dose rate were made using the graphite calorimeter and compared to measurements with the free-air chamber. The measurements were at three different depths in graphite and two different filtrations. The calorimetry measurements at depths in graphite show agreement within 1% with free-air chamber measurements, when converted to absorbed dose to water. The calorimetry at the surface and free-air chamber results show agreement of order 3% when converted to absorbed dose to water. The combined standard uncertainty is 3.9%. Conclusions: The good agreement of the graphite calorimeter and free-air chamber results indicates that both devices are performing as expected. Further investigations at higher dose rates than 50 Gy/s are planned. At higher dose rates, recombination effects for the free-air chamber are much higher and expected to lead to much larger uncertainties. Since the graphite calorimeter does not have problems associated with dose rate, it is an appropriate primary standard detector for the synchrotron IMBL x rays and is the more accurate dosimeter for the higher dose rates expected in radiotherapy applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optoelectronic Picosecond Detection of Synchrotron X-rays

The goal of this research program was to develop a detector that would measure x-ray time profiles with picosecond resolution. This was specifically aimed for use at x-ray synchrotrons, where x-ray pulse profiles have Gaussian time spreads of 50-100 ps (FWHM), so the successful development of such a detector with picosecond resolution would permit x-ray synchrotron studies to break through the pulse width barrier. That is, synchrotron time-resolved studies are currently limited to pump-probe studies that cannot reveal dynamics faster than ~50 ps, whereas the proposed detector would push this into the physically important 1 ps domain. The results of this research effort, described in detail below, are twofold: 1) the original plan to rely on converting electronic signals from a semiconductor sensor into an optical signal proved to be insufficient for generating signals with the necessary time resolution and sensitivity to be widely applicable; and 2) an all-optical method was discovered whereby the x-rays are directly absorbed in an optoelectronic material, lithium tantalate, which can then be probed by laser pulses with the desired picosecond sensitivity for detection of synchrotron x-rays. This research program has also produced new fundamental understanding of the interaction of x-rays and optical lasers in materials that has now created a viable path for true picosecond detection of synchrotron x-rays.

36 MATERIALS SCIENCE↗

SPECTRUM AND ANISOTROPY OF TURBULENCE FROM MULTI-FREQUENCY MEASUREMENT OF SYNCHROTRON POLARIZATION

We consider turbulent synchrotron-emitting media that also exhibit Faraday rotation and provide a statistical description of synchrotron polarization fluctuations. In particular, we consider these fluctuations as a function of the spatial separation of the direction of the measurements and as a function of wavelength for the same line of sight. On the basis of our general analytical approach, we introduce several measures that can be used to obtain the spectral slopes and correlation scales of both the underlying magnetic turbulence responsible for emission and the spectrum of the Faraday rotation fluctuations. We show the synergetic nature of these measures and discuss how the study can be performed using sparsely sampled interferometric data. We also discuss how additional characteristics of turbulence can be obtained, including the turbulence anisotropy and the three-dimensional direction of the mean magnetic field. In addition, we consider the cases when the synchrotron emission and Faraday rotation regions are spatially separated. Appealing to our earlier study, we explain that our new results are applicable to a wide range of spectral indexes of relativistic electrons responsible for synchrotron emission. We expect wide application of our techniques, both with existing synchrotron data sets and with big forthcoming data sets from LOFAR and SKA.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficiency of Synchrotron Radiation from Rotation-powered Pulsars

Synchrotron radiation is widely considered to be the origin of the pulsed non-thermal emissions from rotation-powered pulsars in optical and X-ray bands. In this paper, we study the synchrotron radiation emitted by the created electron and positron pairs in the pulsar magnetosphere to constrain the energy conversion efficiency from the Poynting flux to the particle energy flux. We model two pair creation processes, two-photon collision, which efficiently works in young γ -ray pulsars (≲10{sup 6} year), and magnetic pair creation, which is the dominant process to supply pairs in old pulsars (≳10{sup 6} year). Using the analytical model, we derive the maximum synchrotron luminosity as a function of the energy conversion efficiency. From the comparison with observations, we find that the energy conversion efficiency to the accelerated particles should be an order of unity in the magnetosphere, even though we make a number of the optimistic assumptions to enlarge the synchrotron luminosity. In order to explain the luminosity of the non-thermal X-ray/optical emission from pulsars with low spin-down luminosity L {sub sd} ≲ 10{sup 34} erg s{sup −1}, non-dipole magnetic field components should be dominant at the emission region. For the γ -ray pulsars with L {sub sd} ≲ 10{sup 35} erg s{sup −1}, observed γ -ray to X-ray and optical flux ratios are much higher than the flux ratio between curvature and the synchrotron radiations. We discuss some possibilities such as the coexistence of multiple accelerators in the magnetosphere as suggested from the recent numerical simulation results. The obtained maximum luminosity would be useful to select observational targets in X-ray and optical bands.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron Spectrum of Fast Cooling Electrons in GRBs

We discuss the synchrotron emission of fast cooling electrons in shocks. The fast cooling electrons behind the shocks can generate a position-dependent inhomogeneous electron distribution if they do not have enough time to mix homogeneously. This can lead to a very different synchrotron spectrum in low-frequency bands from that in the homogeneous case, due to the synchrotron absorption. In this paper, we calculate the synchrotron spectrum in the inhomogeneous case in a gamma-ray burst (GRB). Both the forward shock and the reverse shock are considered. We find that for the reverse shock dominated case, we would expect a “reverse shock bump” in the low-frequency spectrum. The spectral bump is due to the combination of synchrotron absorption in both the forward and reverse shock regions. In the low frequencies the forward shock spectrum has two unconventional segments, with spectral slopes of ≲1 and 11/8. The slope of 11/8 has been found by some authors, while the slope of ≲1 is new and due to the approximately constant electron temperature in the optically thick region. In the future, simultaneous observations in multiple bands (especially in the low-frequency bands) in the GRB early afterglow or prompt emission phases will possibly reveal these spectral characteristics and enable us to identify the reverse shock component and distinguish between the forward and reverse shock emissions. This also may be a method with which to diagnose the electron distribution status (homogeneous or inhomogeneous) after fast cooling in the relativistic shock region.

79 ASTRONOMY AND ASTROPHYSICS↗

Synchrotron Self-Compton Emission from the Crab and Other Pulsars

Results of a simulation of synchrotron-self Compton (SSC) emission from a rotation-powered pulsar are presented. The radiating particles are assumed to be both accelerated primary electrons and a spectrum of electron-positron pairs produced in cascades near the polar cap. They follow trajectories in a slot gap using 3D force-free magnetic field geometry, gaining pitch angles through resonant cyclotron absorption of radio photons, radiating and scattering synchrotron emission at high altitudes out to and beyond the light cylinder. Full angular dependence of the synchrotron photon density is simulated in the scattering and all processes are treated in the inertial observer frame. Spectra for the Crab and Vela pulsars as well as two energetic millisecond pulsars, B1821-24 and B1937+21 are simulated using this model. The simulation of the Crab pulsar radiation can reproduce both the flux level and the shape of the observed optical to hard X-ray emission assuming a pair multiplicity of M+ = 3x10(exp 5), as well as the very-high- energy emission above 50 GeV detected by MAGIC and VERITAS, with both the synchrotron and SSC components reflecting the shape of the pair spectrum. Simulations of Vela, B1821-24 and B1937+21, for M+ up to 10(exp 5), do not produce pair SSC emission that is detectable by current telescopes, indicating that only Crab-like pulsars produce significant SSC components. The pair synchrotron emission matches the observed X-ray spectrum of the millisecond pulsars and the predicted peak of this emission at 1-10 MeV would be detectable with planned Compton telescopes.

Self-Compton↗

Residual Stress Analysis of Boronized AISI 1018 Steel

AISI 1018 steel substrates were powder-pack, diffusion boronized at 850 C for 4 h, followed by air quenching. Optical microscopy in conjunction with color etching was used to obtain the average penetration depth of the iron monoboride layer (9 {mu}m) and the iron diboride layer (57 {mu}m). X-ray diffraction by synchrotron radiation, conducted at the National Synchrotron Light Source in Brookhaven National Laboratory, confirmed the presence of iron monoboride and iron diboride in the boronized plain steel substrates. The sin2 {psi} technique was employed to calculate the residual stress found in the iron monoboride layer (-237 MPa) and in the substrate layer (-150 MPa) that is intertwined with the needle-like, iron diboride penetration.

36 MATERIALS SCIENCE↗

High-Resolution Infrared Spectroscopy with Synchrotron Sources

Most applications of synchrotron radiation lie in the ultraviolet and X-ray region, but it also serves as a valuable continuum source of infrared (IR) light which is much brighter (i.e. more highly directional) than that from normal thermal sources. The synchrotron brightness advantage was originally exploited for high spatial resolution spectroscopy of condensed-phase samples. But it is also valuable for high spectral resolution of gas-phase samples, particularly in the difficult far-IR (terahertz) range (1/{lambda} {approx} 10-1000 cm{sup -1}). Essentially, the synchrotron replaces the usual thermal source in a Fourier transform IR spectrometer, giving a increase of up to two (or even more) orders of magnitude in signal at very high-resolution. Following up on pioneering work in Sweden (MAX-lab) and France (LURE), a number of new facilities have recently been constructed for high-resolution gas-phase IR spectroscopy. In the present paper, this new field is reviewed. The advantages and difficulties associated with synchrotron IR spectroscopy are outlined, current and new facilities are described, and past, present, and future spectroscopic results are summarized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synchrotron Radiation Therapy from a Medical Physics point of view

Synchrotron radiation (SR) therapy is a promising alternative to treat brain tumors, whose management is limited due to the high morbidity of the surrounding healthy tissues. Several approaches are being explored by using SR at the European Synchrotron Radiation Facility (ESRF), where three techniques are under development Synchrotron Stereotactic Radiation Therapy (SSRT), Microbeam Radiation Therapy (MRT) and Minibeam Radiation Therapy (MBRT).The sucess of the preclinical studies on SSRT and MRT has paved the way to clinical trials currently in preparation at the ESRF. With this aim, different dosimetric aspects from both theoretical and experimental points of view have been assessed. In particular, the definition of safe irradiation protocols, the beam energy providing the best balance between tumor treatment and healthy tissue sparing in MRT and MBRT, the special dosimetric considerations for small field dosimetry, etc will be described. In addition, for the clinical trials, the definition of appropiate dosimetry protocols for patients according to the well established European Medical Physics recommendations will be discussed. Finally, the state of the art of the MBRT technical developments at the ESRF will be presented. In 2006 A. Dilmanian and collaborators proposed the use of thicker microbeams (0.36-0.68 mm). This new type of radiotherapy is the most recently implemented technique at the ESRF and it has been called MBRT. The main advantage of MBRT with respect to MRT is that it does not require high dose rates. Therefore it can be more easily applied and extended outside synchrotron sources in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗