Search NASA⌕ Search

SEARCH · Search NASA

Results for “targeted imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Applying Two Active Acoustic Technologies to Document Presence of Large Marine Animal Targets at a Marine Renewable Energy Site

Coastal regions are highly used by humans. The growing marine renewable energy (MRE) industry will add to existing anthropogenic pressures in these regions. Regulatory bodies require animal risk assessment before new industrial activities can progress, and MRE is no exception. Preliminary data of marine mammal use of an MRE device deployment location could be informative to permitting. A combination of downlooking hydroacoustics using an echosounder and acoustic camera (imaging sonar) was used to provide a number of large targets (proxy for large fish and marine mammals) in an area of interest for MRE tidal turbine deployment in Western Passage, Maine, USA. Data were collected in May, June, August, and September of 2010 and 2011. Of the nine large targets confirmed to be animals, eight were porpoises and one was a shark. Few large targets were observed in May and June, with the majority (90%) being present in August and September of both years. The most large targets were observed when tidal current speed was less than 1 m·s−1. These data provide a preliminary assessment of large targets in a single location over sixteen 24-h surveys. The aforementioned methodology could be used for future pre- and post-installation assessments at MRE device deployment locations. Their use in concert with visual and passive acoustic monitoring can provide water depth usage by marine mammals, which is a metric that is difficult to assess with passive acoustic and visual techniques.

Staines, Garrett↗

3D reconstruction of an inertial-confinement fusion implosion with neural networks using multiple heterogeneous data sources

3D asymmetries are major degradation mechanisms in inertial-confinement fusion implosions at the National Ignition Facility (NIF). These asymmetries can be diagnosed and reconstructed with the neutron imaging system (NIS) on three lines of sight around the NIF target chamber. Conventional tomographic reconstructions are used to reconstruct the 3D morphology of the implosion using NIS [Volegov et al., J. Appl. Phys. 127, 083301 (2020)], but the problem is ill-posed with only three imaging lines of sight. Asymmetries can also be diagnosed with the real-time neutron activation diagnostics (RTNAD) and the neutron time-of-flight (nToF) suite. Since the NIS, RTNAD, and nToF each sample a different part of the implosion using different physical principles, we propose that it is possible to overcome the limitations of too few imaging lines of sight by performing 3D reconstructions that combine information from all three heterogeneous data sources. This work presents a new machine learning-based reconstruction technique to do just this. By using a simple physics model and group of neural networks to map 3D morphologies to data, this technique can easily account for data of multiple different types. A simple proof-of-principle is presented, demonstrating that this technique can accurately reconstruct a hot-spot shape using synthetic primary neutron images and a hot-spot velocity vector. In particular, the hot-spot’s asymmetry, quantified as spherical harmonic coefficients, is reconstructed to within ±4% of the radius in 90% of test cases. In the future, this technique will be applied to actual NIS, RTNAD, and nToF data to better understand 3D asymmetries at the NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantifying leaf symptoms of sorghum charcoal rot in images of field‐grown plants using deep neural networks

Abstract Charcoal rot of sorghum (CRS) is a significant disease affecting sorghum crops, with limited genetic resistance available. The causative agent, Macrophomina phaseolina (Tassi) Goid, is a highly destructive fungal pathogen that targets over 500 plant species globally, including essential staple crops. Utilizing field image data for precise detection and quantification of CRS could greatly assist in the prompt identification and management of affected fields and thereby reduce yield losses. The objective of this work was to implement various machine learning algorithms to evaluate their ability to accurately detect and quantify CRS in red‐green‐blue images of sorghum plants exhibiting symptoms of infection. EfficientNet‐B3 and a fully convolutional network emerged as the top‐performing models for image classification and segmentation tasks, respectively. Among the classification models evaluated, EfficientNet‐B3 demonstrated superior performance, achieving an accuracy of 86.97%, a recall rate of 0.71, and an F1 score of 0.73. Of the segmentation models tested, FCN proved to be the most effective, exhibiting a validation accuracy of 97.76%, a recall rate of 0.68, and an F1 score of 0.66. As the size of the image patches increased, both models’ validation scores increased linearly, and their inference time decreased exponentially. This trend could be attributed to larger patches containing more information, improving model performance, and fewer patches reducing the computational load, thus decreasing inference time. The models, in addition to being immediately useful for breeders and growers of sorghum, advance the domain of automated plant phenotyping and may serve as a foundation for drone‐based or other automated field phenotyping efforts. Additionally, the models presented herein can be accessed through a web‐based application where users can easily analyze their own images.

Gonzalez, Emmanuel M.↗

Computed Tomography Scanning and Geophysical Measurements of UW Enterprises LP 1-250512-129 Well in Southwestern Indiana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Illinois Basin core of the Upper Devonian-Early Mississippian New Albany Shale Formation from Posey County, Indiana. The primary impetus of this work is a collaboration between Indiana Geological and Water Survey at Indiana University Bloomington, NETL, and Woolsey Operating Company LLC to characterize and make publicly available core information from the New Albany Shale of the Illinois Basin. Core characterization of this unconventional oil/gas well will aid in understanding the lithology changes and the fracture complexity of the New Albany Shale. There is a potential for this formation to be developed in the future for critical mineral and rare earth element (CM/REE) extraction. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/uw-enterprises. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on this core. None of the equipment used was suitable for direct visualization of the pore space in the fine-grained structures studied; however, fractures, discontinuities, and millimeter-scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Targeted higher resolution CT scanning of select sections was performed with NETL’s industrial and micro-CT scanner. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

58 GEOSCIENCES↗

The effect of transient needle lift on the internal flow and near-nozzle spray characteristics for modern GDI systems investigated by high-speed X-ray imaging

The development of the injector nozzle is a dynamic area in regard of several technical aspects. At first, the internal flow influences the near-field spray characteristics via various phenomena such as cavitation and turbulence. However, these phenomena are not fully understood due to their extremely fast, complex and multiscale nature. Furthermore, it governs the spray targeting inside the combustion chamber. High-speed X-ray imaging of GDI injector nozzles is performed in this study. The experimental results presented are related to the internal flow and primary breakup of discharged liquid jets. The injectors used are equipped with nozzles made of aluminum which have been specially developed for these investigations to enhance optical accessibility. The visualization of the needle motion, in-nozzle flow and the primary breakup region provides several exciting observations. First, the needle lift tracking exhibits short overshooting right before the steady-state of the injection phase. Additionally, this event leads to a short-term, however, significant change in the associated performance of the breakup. This phenomenon is found to be a consequence of the transient behavior of the in-nozzle flow. It is shown that under some circumstances hydraulic flip may occur during this overshooting period. The primary jet breakup region is visualized and evaluated by means of image processing. Thus, the transient behavior of liquid jet expansion is quantified in the vicinity of the nozzle. It is observed that the liquid jet direction deviates from the hole axis already at the nozzle outlet, which is caused by internal flow characteristics.

42 ENGINEERING↗

archi : pipeline for light curve extraction of CHEOPS background stars

ABSTRACT High precision time-series photometry from space is being used for a number of scientific cases. In this context, the recently launched CHaracterizing ExOPlanet Satellite (CHEOPS) (ESA) mission promises to bring 20 ppm precision over an exposure time of 6 h, when targeting nearby bright stars, having in mind the detailed characterization of exoplanetary systems through transit measurements. However, the official CHEOPS (ESA) mission pipeline only provides photometry for the main target (the central star in the field). In order to explore the potential of CHEOPS photometry for all stars in the field, in this paper, we present archi, an additional open-source pipeline module1 to analyse the background stars present in the image. As archi uses the official data reduction pipeline data as input, it is not meant to be used as an independent tool to process raw CHEOPS data but, instead, to be used as an add-on to the official pipeline. We test archi using CHEOPS simulated images, and show that photometry of background stars in CHEOPS images is only slightly degraded (by a factor of 2–3) with respect to the main target. This opens a potential for the use of CHEOPS to produce photometric time-series of several close-by targets at once, as well as to use different stars in the image to calibrate systematic errors. We also show one clear scientific application where the study of the companion light curve can be important for the understanding of the contamination on the main target.

Silva, André M.↗

Dual-Image Color Normalization to Enable High-Performance Concentrating Solar Optical Metrology

Concentrating Solar Power (CSP) requires precision mirrors, and these in turn require metrology systems to measure their optical slope. In this project we studied a color-based approach to the correspondence problem, which is the association of points on an optical target with their corresponding points seen in a reflection. This is a core problem in deflectometry-based metrology, and a color solution would enable important new capabilities. We modeled color as a vector in the [R,G,B] space measured by a digital camera, and explored a dual-image approach to compensate for inevitable changes in illumination color. Through a series of experiments including color target design and dual-image setups both indoors and outdoors, we collected reference/measurement image pairs for a variety of configurations and light conditions. We then analyzed the resulting image pairs by selecting example [R,G,B] pixels in the reference image, and seeking matching [R,G,B] pixels in the measurement image. Modulating a tolerance threshold enabled us to assess both match reliability and match ambiguity, and for some configurations, orthorectification enabled us to assess match accuracy. Using direct-direct imaging, we demonstrated color correspondence achieving average match accuracy values of 0.004 h, where h is the height of the color pattern. We found that wide-area two-dimensional and linear one-dimensional color targets outperformed hybrid linear/lateral gradient targets in the cases studied. Introducing a mirror degraded performance under our current techniques, and we did not have time to evaluate whether matches could be reliably achieved despite varying light conditions. Nonetheless, our results thus far are promising.

14 SOLAR ENERGY↗

Improvements in Mirror Surface Measurement with Reflected Computer Vision Targets

Over the last several years, NREL has been developing a system to measure large optical surfaces of heliostat mirrors by reflecting computer vision targets. An advantage of this system, called Reflected Target Nonintrusive Assessment (ReTNA), is that it lends itself well to stitching together many images, each reflecting only part of a larger heliostat. In the last few months, this was taken to a new extreme, with a small target (<5m2) being used to measure a >25m2 long focal length heliostat. These measurements were compared with traditional fringe deflectometry methods, which require a >50m2 target, and photogrammetry. The strengths, weaknesses and limitations of ReTNA are discussed. An estimated uncertainty in this new measurement is presented, along with software improvements and a new wireless data collection system. A bill of materials for this measurement system is presented, which has been designed to use all low-cost, off-the-shelf components. Finally, the next steps for future ReTNA development are presented. Overall, ReTNA can be a valuable optics measurement system, complimentary to existing measurement techniques available for large reflective surfaces.

14 SOLAR ENERGY↗

Harvesting krypton isotopes from the off-gas of an irradiated water target to generate 76Br and 77Br

Abstract A flowing-water target was irradiated with a 150 MeV/nucleon beam of 78 Kr at the National Superconducting Cyclotron Laboratory to produce 77 Kr and 76 Kr. Real-time gamma-imaging measurements revealed the mass transport of the krypton radioisotopes through the target-water processing, or “isotope harvesting”, system. The production rates were determined to be 2.7(1) × 10 –4 nuclei of 76 Kr and 1.18(6) × 10 –2 nuclei of 77 Kr formed per incident 78 Kr ion. Utilizing an off-gas processing line as part of the isotope harvesting system, a total of 7.2(1) MBq of 76 Kr and 19.1(6) MBq of 77 Kr were collected in cold traps. Through the decay, the daughter radionuclides 76 Br and 77 Br were generated and removed from the traps with an average efficiency of 77 ± 12%. Due to the differences in half-lives of 76 Kr and 77 Kr, it was possible to isolate a pure sample of 76 Br with 99.9% radionuclidic purity. The successful collection of krypton radioisotopes to generate 76 Br and 77 Br demonstrates the feasibility of gas-phase isotope harvesting from irradiated accelerator cooling-water. Larger-scale collections are planned for collecting by-product radionuclides from the Facility for Rare Isotope Beams.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Performance of the first mechanically-coupled twisting heliostat: encircled energy vs angle of incidence, and closed loop tracking

The first automatic twisting heliostat, with 8 m2 reflector, was completed and tested on-sun in January 2024. It was set up on a target-oriented dual-axis mount, with the target-axis aimed at a target 113 m to the west. The shape-twisting is purely automatic, made by a mechanical cam coupling to the cross-axis, which turns as the angle of incidence of the sun’s rays on the reflector. Three unsaturated images taken at different times of day were recorded of the sun on the target, reflected at angles of incidence of 5°, 49° and 68°. The measured FWHM of three images is very similar, about 1.09 m or 9.5 mrad, only slightly larger than an ideal solar disc, indicating that the different twisted reflector shapes are close to the ideal biconics needed to image the sun. The encircled energy measured for all three images was similar, 87% within approximately 1.30 m diameter. We report here also on a novel, tracking camera that employs a semitransparent beamsplitter fixed perpendicular to the mirror surface and to the plane of incidence. Over 2.5 hours of measurement of closed loop tracking, errors were ≤ 0.36 mrad rms, in both tracking axes.

14 SOLAR ENERGY↗

High-resolution fiber imaging for pulsed power experiments

This work presents a novel approach for imaging the visible emissions from plasmas in pulsed power experiments using high-resolution plastic optical fibers. The diagnostic consists of a 2 mm diameter core commercial cable constructed of 13 000 individual acrylic fibers. The fibers are fused together to create a single high-resolution bundle. Different designs were investigated to cover a wide range of resolutions and fields of view (3–700 µm and 0.05–45 mm, respectively). The system was tested on the 1-MA Mykonos accelerator at Sandia National Laboratories and successfully imaged visible emission from a hybrid x-pinch target. Diagnostic development and preliminary results are presented.

Fulford, K. W. (ORCID:0000000309691832)↗

Probing nanoparticle substrate interactions with synchrotron infrared nanospectroscopy: Coupling gold nanorod Fabry-Pérot resonances with SiO 2 and $h$-BN phonons

Spectroscopic interrogation of materials in the midinfrared with nanometer spatial resolution is inherently difficult due to the long wavelengths involved, reduced detector efficiencies, and limited availability of spectrally bright, coherent light sources. Technological advances are driving techniques that overcome these challenges, enabling material characterization in this relatively unexplored spectral regime. Synchrotron infrared nanospectroscopy (SINS) is an imaging technique that provides local sample information of nanoscale target specimens in an experimental energy window between 330 and 5000 cm -1 . Here, using SINS, we analyzed a series of individual gold nanorods patterned on a SiO 2 substrate and on a flake of hexagonal boron nitride. The SINS spectra reveal interactions between the nanorod photonic Fabry-Pérot resonances and the surface phonon polaritons of each substrate, which are characterized as avoided crossings. A coupled oscillator model of the hybrid system provides a deeper understanding of the coupling and provides a theoretical framework for future exploration.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advances and Challenges in Fluorescence in situ Hybridization for Visualizing Fungal Endobacteria

We report that Several bacteria have long been known to interact intimately with fungi, but molecular approaches have only recently uncovered how cosmopolitan these interactions are in nature. Currently, bacterial–fungal interactions (BFI) are inferred based on patterns of co-occurrence in amplicon sequencing investigations. However, determining the nature of these interactions, whether the bacteria are internally or externally associated, remains a grand challenge in BFI research. Fluorescence in situhybridization (FISH) is a robust method that targets unique sequences of interest which can be employed for visualizing intra-hyphal targets, such as mitochondrial organelles or, as in this study, bacteria. We evaluate the challenges and employable strategies to resolve intra-hyphal BFI to address pertinent criteria in BFI research, such as culturing media, spatial distribution of bacteria, and abundance of bacterial 16S rRNA copies for fluorescent labeling. While these experimental factors influence labeling and detection of endobacteria, we demonstrate how to overcome these challenges thorough permeabilization, appropriate media choice, and targeted amplification using hybridization chain reaction FISH. Such microscopy imaging approaches can now be utilized by the broader research community to complement sequence-based investigations and provide more conclusive evidence on the nature of specific bacterial–fungal relationships.

59 BASIC BIOLOGICAL SCIENCES↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

A pulsed-power implementation of “Laser Gate” for increasing laser energy coupling and fusion yield in magnetized liner inertial fusion (MagLIF)

Magnetized Liner Inertial Fusion (MagLIF) at Sandia National Laboratories involves a laser preheating stage,where a few-ns laser pulse passes through a few-micron-thick plastic window to preheat gaseous fusion fuel contained within the MagLIF target. Interactions with this window reduce heating e ciency and mix window and target materials into the fuel. A recently proposed idea called \Laser Gate" involves removing the window well before the preheating laser is applied. In this article, we introduce experimental proof-of-principle results for a pulsed-power implementation of Laser Gate, where a thin current-carrying wire weakens the perimeter of the window, allowing the fuel pressure to push the window open and away from the preheating laser path. For this e ort, transparent targets were fabricated and a test facility capable of studying this version of Laser Gate was developed. A 12-frame bright- eld laser schlieren/shadowgraphy imaging system captured the window opening dynamics on microsecond timescales. The images exhibit that the window remains largely intact as it opens and detaches from the target. A column of escaping pressurized gas appears to prevent the detached window from inadvertently moving into the preheating laser path.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toward implementing autonomous adaptive data acquisition for scanning hyperspectral imaging of biological systems

Autonomous experimentation is an emerging area of research, primarily related to autonomous vehicles, scientific combinatorial discovery approaches in materials science and drug discovery, and iterative research loops of planning, experimentation, and analysis. However, autonomous approaches developed in these contexts are difficult to apply to high-dimensional mapping technologies, such as scanning hyperspectral imaging of biological systems, due to sample complexity and heterogeneity. We briefly cover the history of adaptive sampling algorithms and surrogate modeling in order to define autonomous adaptive data acquisition as an objective-based, flexible building block for future biological imaging experimentation driven by intelligent infrastructure. We subsequently summarize the recent implementations of autonomous adaptive data acquisition (AADA) for scanning hyperspectral imaging, assess how these address the difficulties of autonomous approaches in hyperspectral imaging, and highlight the AADA design variation from a goal-oriented perspective. Finally, we present a modular AADA architecture that embeds AADA-driven flexible building blocks to address the challenge of time resolution for high-dimensional scanning hyperspectral imaging of nonequilibrium dynamical systems. In our example research-driven experimental design case, we propose an AADA infrastructure for time-resolved, noninvasive, and label-free scanning hyperspectral imaging of living biological systems. This AADA infrastructure can accurately target the correct state of the system for experimental workflows that utilize subsequent expensive, high-information-content analytical techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Tip-Enhanced Raman Chemical and Chemical Reaction Imaging in H 2 O with Sub-3-nm Spatial Resolution

Reproducible chemical and chemical reaction nano-imaging at solid-liquid interfaces remains challenging, particularly when resolutions on the order of a few nm are sought after. In this work, we demonstrate the latter through liquid tip-enhanced Raman (TER) measurements that target gold nanoplates functionalized with 4-mercaptobenzonitrile (MBN). In addition to chemical imaging and local optical field nano-visualization with high spatial resolution, we observe the signatures of 4-mercaptobenzoic acid, which forms as a result of plasmon-induced hydrolysis of MBN. Evidently, the solvent leads to distinct plasmon-induced/enhanced chemical reaction pathways that have not been documented. Here this work shows that such reactions that take place at solid-liquid interfaces can be tracked with a record sub-3 nm spatial resolution via TER spectral nano-imaging in liquids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and Characterization of Radio-Halogenated Talazoparib Analogues for Imaging and Radioligand Therapy

Abstract Talazoparib (TZ) is a potent poly(ADP-ribose) polymerase 1/2 (PARP1/2) inhibitor that uniquely traps PARP complexes at sites of single-strand DNA damage thereby offering opportunities for targeted radioligand therapy. Radiolabeled halogenated TZ derivatives were synthesized using boronic ester precursors to enable incorporation of diagnostic and therapeutic radionuclides: 18F for PET imaging, 77Br for Auger electron radiotherapy, and 211At for targeted alpha radiotherapy. Copper-mediated radio-halogenation afforded racemic 18F-TZ, 77Br-TZ, and 211At-TZ in sufficient radiochemical yields (4.3 ± 2.6%, n = 33; 29.0 ± 12.0%, n = 4; 3.6 ± 3.8%, n = 9, respectively), ∼99% radiochemical purity and proven stability under formulation conditions. Molecular dynamics simulations of halo-TZ derivatives predicted an inverse relationship between halogen size and PARP1 binding affinity. Indeed, cell uptake of radio-halogenated TZ analogues indicated selective uptake in a panel of cell types that correlated with PARP1 levels but was inversely related to the atomic radii of the halogen series. Despite modest specific activity and specific uptake, 77Br-TZ showed significant cytotoxicity. Further investigation of 18F-TZ with 77Br-TZ as a radiotheranostic pair will be facilitated by the synthetic schemes herein.

Muzzioli, Riccardo [The University of Texas MD And↗