Search NASA⌕ Search

SEARCH · Search NASA

Results for “test system test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Initial Studies Toward Real-Time Transmission Path Rating

Demand continues to increase while transmission line construction is being constrained by multiple factors— economic, environmental, and political. Effective and efficient utilization of transmission lines is thus of great importance in an open access environment. Large blocks of power are transferred from areas with inexpensive generation to heavy load demand areas or areas with high generation costs. This results in some transmission paths being loaded closer to their path ratings, which limits further power transfer between areas. Traditionally, rating of important paths was determined off line by assuming the worst-case study scenario; once determined, it could be used for years. With increasing uncertainty arising from rapid growth of renewable energy and smart technologies, path rating studies are needed in near-real time to account for the latest system status and support a reliable and economic power grid. This paper adopts a simplified procedure based on standards of the North American Electric Reliability Corporation (NERC) to determine total transfer capability (TTC) or transfer limit for the purpose of demonstrating the benefits and necessity of real-time path rating. Initial studies are conducted to compute TTC of a two-area test system and a 39-bus test system. Results indicate that path rating can be significantly affected by loading conditions, generator schedules, system topology and other factors.

Singh, Ruchi↗

Distributed Control and Optimization of Virtual Inertia in Power Systems

The integration of renewable energy sources into power grids through inverter-based resources (IBRs) reduces system inertia, leading to faster frequency dynamics and potential grid instability. This paper proposes a distributed, consensus-based approach for the real-time control and optimization of inertia sources during system disturbances, enhancing both system stability and economic performance. Furthermore, we integrate this approach with the traditional inertia placement problem, demonstrating its suitability for existing frameworks. We validate its effectiveness in a 4-bus test system and a two-area 8-bus test system, showcasing its potential for scalable, dynamic inertia management in low-inertia grids.

Yadav, Ajay [ORNL] (ORCID:000000016111881X)↗

Water and Climate Impacts on Power System Operations: The Importance of Cooling Systems and Demand Response Measures

The U.S. electricity sector is highly dependent upon water resources; changes in water temperatures and water availability can affect operational costs and the reliability of power systems. Despite the importance of water for power system operations, the effects of changes in water characteristics on multiple generators in a system are generally not modeled. Moreover, demand response measures, which can change the magnitude and timing of loads and can have beneficial impacts on power system operations, have not yet been evaluated in the context of water-related power vulnerabilities. This effort provides a first comprehensive vulnerability and cost analysis of water-related impacts on a modeled power system and the potential for demand response measures to address vulnerability and cost concerns. This study uniquely combines outputs and inputs of a water and power plant system model, production cost, model, and relative capacity value model to look at variations in cooling systems, policy-related thermal curtailments, and demand response measures to characterize costs and vulnerability for a test system. Twenty-five scenarios over the course of one year are considered: a baseline scenario as well as a suite of scenarios to evaluate six cooling system combinations, the inclusion or exclusion of policy-related thermal curtailments, and the inclusion or exclusion of demand response measures. A water and power plant system model is utilized to identify changes in power plant efficiencies resulting from ambient conditions, a production cost model operating at an hourly scale is used to calculate generation technology dispatch and costs, and a relative capacity value model is used to evaluate expected loss of carrying capacity for the test system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analyzing the Impacts of Increased Wind Power on Generation Revenue Sufficiency

The Revenue Sufficiency Guarantee (RSG), as part of make-whole (or uplift) payments in electricity markets, is designed to recover the generation resources' offer-based production costs that are not otherwise covered by their market revenues. Increased penetrations of wind power will bring significant impacts to the RSG payments in the markets. However, literature related to this topic is sparse. This paper first reviews the industrial practices of implementing RSG in major U.S. independent system operators (ISOs) and regional transmission operators (RTOs) and then develops a general RSG calculation method. Finally, an 18-bus test system is adopted to demonstrate the impacts of increased wind power on RSG payments.

17 WIND ENERGY↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced Tensor Completion Based Approaches for State Estimation in Distribution Systems

Grid state estimation is essential for effective control and management of distribution systems. While weighted least squares has been the conventional method for state estimation, sparsity-aware methods have become popular due to their superior performance with limited data. Matrix completion and compressed sensing-based state estimation approaches exploit the underlying smoothness in the state variables. However, classic matrix completion methods do not take into account the temporal correlation of system states. Compressed sensing methods, on the other hand, require an appropriate choice of sparsifying basis that may not be easy to identify. This paper proposes a blocktensor completion based framework which uses an alternative approach to estimate voltage phasor, power injections and branch currents. This approach utilizes the temporal correlation of the system states in a tensor trace-norm minimization formulation with power flow equations as constraints. Herein, feature scaling is introduced in the problem formulation to benefit from the improved sensitivity of the tensor trace norm to the matrix columns in the scaled unfoldings of the tensor. Weighted tensor norm is utilized to exploit the structures of the different unfoldings of the state measurement tensor to improve the voltage estimation. The estimation accuracy is further improved by alternatively estimating the tensor columns and increasing the available data at each stage in the tensor completion process. The proposed methods are evaluated on the IEEE-33, 37 test systems and a 100- node test system. The proposed methods are shown to provide significant performance gains relative to the classic matrix and tensor completion based approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RELAP5-3D Resolution of Known Restart/Backup Issues

The state-of-the-art nuclear reactor system safety analysis computer program developed at the Idaho National Laboratory (INL), RELAP5-3D, continues to adapt to changes in computer hardware and software and to develop to meet the ever-expanding needs of the nuclear industry. To continue at the forefront, code testing must evolve with both code and industry developments, and it must work correctly. To best ensure this, the processes of Software Verification and Validation (V&V) are applied. Verification compares coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions. A form of this, sequential verification, checks code specifications against coding only when originally written then applies regression testing which compares code calculations between consecutive updates or versions on a set of test cases to check that the performance does not change. A sequential verification testing system was specially constructed for RELAP5-3D to both detect errors with extreme accuracy and cover all nuclear-plant-relevant code features. Detection is provided through a “verification file” that records double precision sums of key variables. Coverage is provided by a test suite of input decks that exercise code features and capabilities necessary to model a nuclear power plant. A matrix of test features and short-running cases that exercise them is presented. This testing system is used to test base cases (called null testing) as well as restart and backup cases. It can test RELAP5-3D performance in both standalone and coupled (through PVM to other codes) runs. Application of verification testing revealed numerous restart and backup issues in both standalone and couple modes. This document reports the resolution of these issues.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Building Large-Scale U.S. Synthetic Electric Distribution System Models

Rapid increases in distributed energy resources on distribution systems are prompting research efforts to improve and evaluate electric power distribution algorithms; however, there is a shortage of realistic, large-scale, U.S.-style test systems for the evaluation of such advanced algorithms. Some available tools to build large-scale test systems are of European style, and their application to studies focused on the United States might not be desirable given very different characteristics between the European and U.S. distribution designs. Motivated by this need, this paper develops detailed algorithms to build large-scale U.S. distribution systems and incorporates them in a new Reference Network Model, RNM-US. The approach starts with information from street maps and a catalog with electric equipment that includes power lines, transformers, voltage regulators, capacitors, and switching devices. The paper presents the algorithms through an illustrative case study of the different steps that comprise the process of building a synthetic distribution grid. Finally, the paper presents a medium- and a large-scale data set covering 10 million electrical nodes and 120,000 km of power lines, demonstrating the applicability of the proposed method to build very large-scale synthetic distribution systems.

27 ARPA - Advanced Research Projects Agency-Energy↗

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗

A NOVEL TOOL FOR IMPROVING THE DATA COLLECTION PROCESS DURING CONTROL ROOM MODERNIZATION HUMAN-SYSTEM INTERFACE TESTING AND EVALUATION ACTIVITIES

The U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program is developing a scientific basis to extend the existing U.S. nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure NPP long-term reliability, productivity, safety, and security. Under the Advanced Instrumentation, Information, and Control (II&C) Systems Technologies pathway, the LWRS Program conducts targeted research and development to address long-term aging and obsolescence of existing instrumentation and control technologies, as well as to implement and test new digital II&C technology that enables broad innovation and business improvement in the NPP operating model. To this end, the role of human factors engineering (HFE) is important as part of ensuring that the control room modernization (CRM) activities account for the operator’s cognitive and physiological characteristics. Part of the HFE process for CRM entails conducting tests and evaluations (T&Es) that will inform the design of new human-system interface (HSI) technologies. Qualitative data that captures operator feedback and important human-system interactions are an important part of T&E. However, the analyzing this qualitative data in order to provide actionable design recommendations can be time-consuming and error prone. This paper presents an early version of a tool that can be used to analyze this qualitative data to (1) sift through freeform text for improved design issue identification, (2) maintain consistency in theme coding conventions, and (3) readily provide actionable design guidance that can be traceable to state-of-the-art HFE guidelines such as NUREG-0700. A description of this tool is discussed next.

99 GENERAL AND MISCELLANEOUS↗

pnnl/i2x

Interconnection Innovation e-Xchange (i2x) Test Systems allows for scripted customizations of social behavior, recovery operations, investment decisions, and metrics in a simplified Python module. Public test systems allow for replication of results by other stakeholders

McDermott, Tom↗

Results of the KRUSTY Warm Critical Experiments

The Kilowatt Reactor Using Stirling TechnologY (KRUSTY) was a prototypic nuclear-powered test of a 5-kW(thermal) Kilopower space reactor. This paper presents results from the KRUSTY warm critical experiments, which were completed prior to the final system test. The first set of criticals comprised cold or zero-power criticals; i.e., the core was not heated by fission power. These were followed by three warm criticals, where fission power heated the core to 200°C, 300°C, and 450°C, respectively. These criticals provided the data, confidence, and regulatory framework that were needed to proceed with the KRUSTY nuclear system test. The criticals also provided valuable data for the benchmarking of codes applicable to all nuclear systems. Finally, a comparison of KRUSTY results to pretest predictions is provided, and overall, the models matched the experimental results very closely.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A novel tool for improving the data collection process during control room modernization human-system interface testing and evaluation activities - 271

The U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program is developing a scientific basis to extend the existing U.S. nuclear power plant (NPP) operating life beyond the current 60-year licensing period and to ensure NPP long-term reliability, productivity, safety, and security. Under the Advanced Instrumentation, Information, and Control (II and C) Systems Technologies pathway, the LWRS Program conducts targeted research and development to address long-term aging and obsolescence of existing instrumentation and control technologies, as well as to implement and test new digital II and C technology that enables broad innovation and business improvement in the NPP operating model. To this end, the role of human factors engineering (HFE) is important as part of ensuring that the control room modernization (CRM) activities account for the operator's cognitive and physiological characteristics. Part of the HFE process for CRM entails conducting tests and evaluations (T and Es) that will inform the design of new human-system interface (HSI) technologies. Qualitative data that captures operator feedback and important human-system interactions are an important part of T and E. However, the analyzing this qualitative data in order to provide actionable design recommendations can be time-consuming and error prone. This paper presents an early version of a tool, which uses a combination of natural language processing and supervised machine learning to support the analysis of qualitative data. The objectives of this tool is to improve the process of (1) sifting through freeform text for improved design issue identification, (2) maintaining consistency in theme coding conventions, and (3) readily providing actionable design guidance that can be traceable to state-of-the-art HFE guidelines such as NUREG-0700. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Experimental Determination of Demand Response Control Models and Cost of Control for Ensembles of Window-Mount Air Conditioners

Control of consumer electrical devices for providing electrical grid services is expanding in both the scope and the diversity of loads that are engaged in control, but there are few experimentally-based models of these devices suitable for control designs and for assessing the cost of control. A laboratory-scale test system is developed to experimentally evaluate the use of a simple window-mount air conditioner for electrical grid regulation services. The experimental test bed is a single, isolated air conditioner embedded in a test system that both emulates the thermodynamics of an air conditioned room and also isolates the air conditioner from the real-world external environmental and human variables that perturb the careful measurements required to capture a model that fully characterizes both the control response functions and the cost of control. The control response functions and cost of control are measured using harmonic perturbation of the temperature set point and a test protocol that further isolates the air conditioner from low frequency environmental variability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Hydrological Data on Power System Operational Studies: Preprint

Hydropower is expected to play an important role in maintaining grid reliability and flexibility as the share of of variable renewable energy increases. While the current hydropower operational models have been studied and used widely, they haven't been updated for decades to meet new performance standards. For example, current steady state and dynamic models often neglect hydrological conditions, which may lead to unrealistic expectations when relying on hydropower for energy and ancillary services. To study this impact, a multi-timescale hydrological model was created by leveraging the National Renewable Energy Laboratory-developed Multi-timescale Integrated Dynamics and Scheduling (MIDAS) tool. Using MIDAS, we compare the impact of considering hydrological conditions in a day-ahead unit commitment (DAUC) schedule on the reduced 240-bus Western Interconnect (WI) test system under winter and summer case studies. We show that neglecting current hydrological conditions of hydropower plants in power system models can lead to an overestimation of hydropower capabilities, which could lead to power balancing issues. For example, power system DAUC simulation results of our reduced test system show that in the case where hydrological conditions are not considered in the model, an approximate 31% overestimation of hydropower capabilities occurs in the summer case and approximately 60% occurs in the winter case compared to what is available. Additionally, results show an underestimation of WI day-ahead power system generation costs by approximately $54M - $80M in the weekly summer scenario and $116M - $126M in the weekly winter scenario. This analysis helps to underscore the importance of considering hydrological data in power system operational studies.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

High-Frequency Signature-Based Fault Detection for Future MV Distribution Grids

Increasing penetration levels of inverter based distributed energy resources (DERs) impact the legacy distribution system protection. Inverter based DERs provide approximately 1.2-2 pu fault current. In systems with high penetration of inverter based DERs, it is difficult for over-current based protection schemes to differentiate between normal loading conditions and a fault. Directional, distance, and adaptive forms of protection schemes are also affected by low fault currents. This paper analyzes fault generated traveling wave (TW) based high-frequency signatures in the distribution system. In order to simulate such signatures, frequency-dependent distributed parameter line modeling approach is used in this research work to represent distribution lines and underground cables. Modified IEEE 13-bus medium voltage test system is modeled in electromagnetic transient simulation tool and multiple transient scenarios are simulated in this test system. The results are analyzed to understand the high-frequency signatures that can be used to detect and locate faults under high penetration of DERs.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Wind Turbine Generator System Duration Test Report for the ARE 442 Wind Turbine

This test is being conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, four turbines are being tested at the NWTC as a part of this project. Duration testing is one of up to 5 tests that may be performed on the turbines, including power performance, safety and function, noise, and power quality tests. The results of the testing provide manufacturers with reports that may be used for small wind turbine certification. The test equipment includes a grid connected ARE 442 wind turbine mounted on a 30.5 meter (100 ft) lattice tower manufactured by Abundant Renewable Energy. The system was installed by the NWTC Site Operations group with guidance and assistance from Abundant Renewable Energy.

17 WIND ENERGY↗