Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing discharge simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Coil-On-Plug Ignition for Oxygen/Methane Liquid Rocket Engines in Thermal-Vacuum Environments

A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX)/liquid methane (LCH4) rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/LCH4 propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. A coil-on-plug ignition system has been developed to successfully demonstrate ignition reliability at these conditions while preventing corona discharge issues. The ICPTA uses spark plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp -2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, hot-fire testing at Plum Brook demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/LCH4 propulsion systems in future spacecraft.

Melcher, John C.↗

Experimental Demonstration of a Supersonic Spike Ejector

Spike diffusers are presented as a means to improve supersonic ejector efficiency via reduction in shock losses. Design, fabrication, and testing of an articulated prototype is described. Experimental results are compared to empirical performance curves representing the loci of optimal one- and two-stage conventional ejectors driven by dry air and discharging to atmosphere. Operated at a compression ratio of ~10 with all inputs equal, the spike ejector is shown to have achieved up to 2.19X and 1.83X the secondary mass throughput of the one- and two-stage references, respectively. This suggests the potential of spike diffusers to reduce ejector operating costs by ~50%.

wind tunnel↗

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Coil-On-Plug Ignition for LOX/Methane Liquid Rocket Engines in Thermal Vacuum Environments

A coil-on-plug ignition system has been developed and tested for Liquid Oxygen (LOX) / liquid methane rocket engines operating in thermal vacuum conditions. The igniters were developed and tested as part of the Integrated Cryogenic Propulsion Test Article (ICPTA), previously tested as part of the Project Morpheus test vehicle. The ICPTA uses an integrated, pressure-fed, cryogenic LOX/methane propulsion system including a reaction control system (RCS) and a main engine. The ICPTA was tested at NASA Glenn Research Center's Plum Brook Station in the Spacecraft Propulsion Research Facility (B-2) under vacuum and thermal vacuum conditions. In order to successfully demonstrate ignition reliability in the vacuum conditions and eliminate corona discharge issues, a coil-on-plug ignition system has been developed. The ICPTA uses spark-plug ignition for both the main engine igniter and the RCS. The coil-on-plug configuration eliminates the conventional high-voltage spark plug cable by combining the coil and the spark-plug into a single component. Prior to ICPTA testing at Plum Brook, component-level reaction control engine (RCE) and main engine igniter testing was conducted at NASA Johnson Space Center (JSC), which demonstrated successful hot-fire ignition using the coil-on-plug from sea-level ambient conditions down to 10(exp.-2) torr. Integrated vehicle hot-fire testing at JSC demonstrated electrical and command/data system performance. Lastly, Plum Brook testing demonstrated successful ignitions at simulated altitude conditions at 30 torr and cold thermal-vacuum conditions at 6 torr. The test campaign successfully proved that coil-on-plug technology will enable integrated LOX/methane propulsion systems in future spacecraft.

Melcher, John C.↗

Composite load spectra for select space propulsion structural components

The work performed to develop composite load spectra (CLS) for the Space Shuttle Main Engine (SSME) using probabilistic methods. The three methods were implemented to be the engine system influence model. RASCAL was chosen to be the principal method as most component load models were implemented with the method. Validation of RASCAL was performed. High accuracy comparable to the Monte Carlo method can be obtained if a large enough bin size is used. Generic probabilistic models were developed and implemented for load calculations using the probabilistic methods discussed above. Each engine mission, either a real fighter or a test, has three mission phases: the engine start transient phase, the steady state phase, and the engine cut off transient phase. Power level and engine operating inlet conditions change during a mission. The load calculation module provides the steady-state and quasi-steady state calculation procedures with duty-cycle-data option. The quasi-steady state procedure is for engine transient phase calculations. In addition, a few generic probabilistic load models were also developed for specific conditions. These include the fixed transient spike model, the poison arrival transient spike model, and the rare event model. These generic probabilistic load models provide sufficient latitude for simulating loads with specific conditions. For SSME components, turbine blades, transfer ducts, LOX post, and the high pressure oxidizer turbopump (HPOTP) discharge duct were selected for application of the CLS program. They include static pressure loads and dynamic pressure loads for all four components, centrifugal force for the turbine blade, temperatures of thermal loads for all four components, and structural vibration loads for the ducts and LOX posts.

Newell, J. F.↗

Hierarchical Control of Distributed Battery Energy Storage System in a DC Microgrid

This paper presents a novel hierarchical control approach of a DC microgrid (DCMG) which is supplied by a distributed battery energy storage system (BESS). With this approach, all battery units distributed in the BESS can be controlled to discharge with accurate current sharing and state-of-charge (SoC) balancing. Similar to other hierarchical control approaches used in DCMGs, this approach consists of three levels: (1) primary control, (2) secondary control and (3) tertiary control. This work includes defining a unit control error (UCE) at the secondary control level and evaluating current sharing weights at tertiary control level. A centralized controller at secondary control level is designed to detect the UCEs of each battery unit, and to restore the average voltage of a DCMG and control battery current sharing simultaneously. The distributed battery units share the load current in a DCMG based on weights. These weights are evaluated at the tertiary control level based on battery SoCs. The approach’s effectiveness was confirmed in digital simulation tests with the same simulation model as used in the NASA AMPS Modular Hardware Emulator.

Jing Zhang↗

Jupiter entry simulation with the ANAA shock tube

An annular arc accelerator (ANAA) shock tube has been built which produces shock velocities and pressures that simulate entry into the atmosphere of Jupiter. The ANAA driver deposits the energy of an arc discharge into a flowing gas, which then expands and cools without any delay for the opening of a diaphragm. A flow transducer, trigger system, and spark gap switches have been developed to coordinate the flow from a high-pressure helium driver with the discharge from a 300-kJ capacitor bank. Shock velocities up to 47 km/sec have been produced in 1.0 torr of hydrogen with the ANAA shock tube, compared with 35 km/sec velocity produced in a conical arc driver with three times the available energy. Attenuation with the ANAA shock tube is comparable to that of a conical arc driver shock tube, and initial spectroscopic measurements indicate that an impurity-free test slug is formed behind the shock wave.

Leibowitz, L. P.↗

Electromagnetic radiation generated by arcing in low density plasma

An unavoidable step in the process of space exploration is to use high-power, very large spacecraft launched into Earth orbit. Obviously, the spacecraft will need powerful energy sources. Previous experience has shown that electrical discharges occur on the surfaces of a high-voltage array, and these discharges (arcs) are undesirable in many respects. Moreover, any high voltage conductor will interact with the surrounding plasma, and that interaction may result in electrical discharges between the conductor and plasma (or between two conductors with different potentials, for example, during docking and extravehicular activity). One very important aspect is the generation of electromagnetic radiation by arcing. To prevent the negative influence of electromagnetic noise on the operation of spacecraft systems, it seems necessary to determine the spectra and absolute levels of the radiation, and to determine limitations on the solar array bias voltage that depend on the parameters of LEO plasma and the technical requirements of the spacecraft equipment. This report describes the results of an experimental study and computer simulation of the electromagnetic radiation generated by arcing on spacecraft surfaces. A large set of high quality data was obtained during the Solar Array Module Plasma Interaction Experiment (SAMPIE, flight STS-62) and ground test. These data include the amplitudes of current, pulse forms, duration of each arc, and spectra of plasma waves. A theoretical explanation of the observed features is presented in this report too. The elaborated model allows us to determine the parameters of the electromagnetic noise for different frequency ranges, distances from the arcing site, and distinct kinds of plasma waves.

Vayner, Boris V.↗

Euler equations and the Sod shock tube problem

The Euler equations are a subset of the magnetohydrodynamic (MHD) equations in the infinitely collisional, unmagnetized limit. MHD modeling is central to many areas of plasma physics, ranging from low-temperature glow discharges to inertial confinement fusion. An important aspect of the Euler equations is their ability to describe states with discontinuities, such as shock waves. A standard benchmark test for numerical implementation of the Euler equations is the Sod shock tube. In this test, the system is initialized at rest with a pressure and density discontinuity, which results in a shock wave traveling into the low-pressure region and a rarefaction wave traveling into the high-pressure region. Starting with the presentation of the Euler equations, a numerical algorithm is presented here to solve these equations in one dimension. This is followed by an overview of the Sod shock tube problem that includes the precise initial setup and the analytic solution. Finally, the analytic solution is compared with results from numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Phase 2: HGM air flow tests in support of HEX vane investigation

Following the start of SSME certification testing for the Pratt and Whitney Alternate Turbopump Development (ATD) High Pressure Oxidizer Turbopump (HPOTP), cracking of the leading edge of the inner HEX vane was experienced. The HEX vane, at the inlet of the oxidizer bowl in the Hot Gas Manifold (HGM), accepts the HPOTP turbine discharge flow and turns it toward the Gaseous Oxidizer Heat Exchanger (GOX HEX) coil. The cracking consistently initiated over a specific circumferential region of the hex vane, with other circumferential locations appearing with increased run time. Since cracking had not to date been seen with the baseline HPOTP, a fluid-structural interaction involving the ATD HPOTP turbine exit flowfield and the HEX inner vane was suspected. As part of NASA contract NAS8-36801, Pratt and Whitney conducted air flow tests of the ATD HPOTP turbine turnaround duct flowpath in the MSFC Phase 2 HGM air flow model. These tests included HEX vane strain gages and additional fluctuating pressure gages in the turnaround duct and HEX vane flowpath area. Three-dimensional flow probe measurements at two stations downstream of the turbine simulator exit plane were also made. Modifications to the HPOTP turbine simulator investigated the effects on turbine exit flow profile and velocity components, with the objective of reproducing flow conditions calculated for the actual ATD HPOTP hardware. Testing was done at the MSFC SSME Dynamic Fluid Air Flow (Dual-Leg) Facility, at air supply pressures between 50 and 250 psia. Combinations of turbine exit Mach number and pressure level were run to investigate the effect of flow regime. Information presented includes: (1) Descriptions of turbine simulator modifications to produce the desired flow environment; (2) Types and locations for instrumentation added to the flow model for improved diagnostic capability; (3) Evaluation of the effect of changes to the turbine simulator flowpath on the turbine exit flow environment; and (4) Comparison of the experimental turbine exit flow environment to the environment calculated for the ATD HPOTP.

Cox, G. B., Jr.↗

Field and Model Data Associated with the Manuscript “Drivers of Streamflow Intermittency in Humid Regions: 1. Evaluating Above- and Below-ground Controls of Flow Persistence in a Forested Catchment”

This package contains field data, modeling files, and scripts supporting the investigation of the drivers of streamflow intermittency in a forested catchment. It includes the field data collected from electrical resistivity tomography (ERT) surveys, ground penetrating radar (GPR), continuous self-potential (SP) monitoring, electromagnetic (EM) imaging, groundwater and stilling well. In addition, it contains the data and results of the coupled water- and electrical-flow model developed using the COMSOL Multiphysics and Advanced Terrestrial Simulator (ATS), as well as software files and Jupyter notebooks used to process the data and generate figures in the manuscript submitted for peer review. The data archive is organized in the following directories: 1) Climate Includes hourly precipitation and daily evapotranspiration time series (2024 – 2025) provided as CSV files, alongside a text file detailing dataset units. 2) Coupled_model Contains two subfolders: Synthetic and Field_Application subfolder. Synthetic subfolder contains the ATS XML input script (can be opened using any code editor) for the four synthetic hydrological cases tested (Connected and gaining, Connected and losing, Disconnected and losing, and dry stream). It also includes other experimental cases to test the influence of precipitation and concentration gradient. For each synthetic case, the flow model simulation is executed using the ATS XML scripts and the included Python script (generate_data_set.py) to convert ATS output to COMSOL-ready input. COMSOL Multiphysics template (.mph can be opened with the commercial software COMSOL and requires a license) is executed using the ATS output data to simulate the potential field. It also includes the Synthetic_model_plot.ipynb (can be opened using any code editor) to visualize the SP result and generate manuscript figures. The data subfolder contains mesh files to run both the ATS (.exo and .stl files can be viewed using Paraview; .h5 files can be opened using HDFView software and h5py Python package) and COMSOL models. Field_Application subfolder contains two subfolders: ES_MDA_inversion and Final_Model. ES_MDA_inversion contains the Python script (.py can be opened using any code editor) and SP observation data used to run the Ensemble Smoother with Multiple Data Assimilation (ES-MDA) inversion sequence to get the optimal model parameters. The Final_model subfolder contains the ATS XML input scripts, data files, output data for the two SP sites. The same workflow steps outlined for the Synthetic subfolder apply here. It also contains the Jupyter notebook (Plot_final_calib.ipynb) to visualize the results of the modeled SP, stream-groundwater exchange and moisture content. 3) Discharge Includes the electrical conductivity (EC) time series (provided as CSV files) from salt slug injections. It also includes the Jupyter notebook (Discharge_process.ipynyb) used to estimate discharge. All discharge measurements collated into rating_curve_processed.csv 4) EM Contains the CSV file of the EM data from the DUALEM-42, including spatial coordinates (x, y, z), apparent conductivity, and in-phase measurements at 2 m coil separations for horizontal coplanar (HCP) and perpendicular (PRP) geometries. 5) ERT Contains raw resistivity data (provided as CSV files), spatial location of each of the electrodes (provided as CSV files), and files used for the resistivity inversion (.resipy can be opened with the open-source ResIPy software). 6) GPR Includes GPR field datasets collected at 100 MHz and 250 MHz antenna frequencies, along with the processing/interpretation project file (GPR_process.gpz can be viewed using EKKO_Project 6, a commercial software by Sensors & Software that requires a license). 7) Slug_test Includes the slug test data at all the groundwater wells provided as CSV files, as well as the Jupyter notebook (Slug_test.ipynb) for calculating hydraulic conductivity. 8) SP Contains the SP data collected in field at the two SP sites (one in the perennial reach and the other in the intermittent reach), provided as DAT files. 9) Well_data Contains two subfolders: 1) Raw, which provides unprocessed pressure, electrical conductivity and temperature timeseries downloaded from the loggers in all the groundwater and stilling wells, and 2) Processed, which contains sorted, QA/QC timeseries data for each well. The data archive also contains data_process.ipynb, a Jupyter notebook used for field data analysis and generating figures (plotting well, SP, climate, and discharge data, as well as calculating head gradient at sites with nested groundwater wells). It also includes DTW.ipynb, a Jupyter notebook containing the code for the dynamic time warping (DTW) with sliding window to evaluate SP signal synchronicity.

ATS↗

Unitized Regenerative Fuel Cell System Gas Storage/Radiator Development

The ancillary components for Unitized Regenerative Fuel Cell (URFC) Energy Storage System are being developed at the NASA Glenn Research Center. This URFC system is unique in that it uses the surface area of the hydrogen and oxygen storage tanks as radiating heat surfaces for overall thermal control of the system. The waste heat generated by the URFC stack during charging and discharging is transferred from the cell stack to the surface of each tank by loop heat pipes. The heat pipes are coiled around each tank and covered with a thin layer of thermally conductive layer of carbon composite. The thin layer of carbon composite acts as a fin structure that spreads the heat away from the heat pipe and across the entire tank surface. Two different sized commercial grade composite tanks were constructed with integral heat pipes and tested in a thermal vacuum chamber to examine the feasibility of using the storage tanks as system radiators. The storage radiators were subjected to different steady-state heat loads and varying heat load profiles. The surface emissivity and specific heat capacity of each tank were calculated. The results were incorporated into a model that simulates the performance of similar radiators using lightweight, space rated carbon composite tanks.

Jakupca, Ian↗

NASA Tech Briefs, February 2006

Topics discussed include: Nearly Direct Measurement of Relative Permittivity; DCS-Neural-Network Program for Aircraft Control and Testing; Dielectric Heaters for Testing Spacecraft Nuclear Reactors; Using Doppler Shifts of GPS Signals To Measure Angular Speed; Monitoring Temperatures of Tires Using Luminescent Materials; Highly Efficient Multilayer Thermoelectric Devices; Very High-Speed Digital Video Capability for In-Flight Use; MMIC DHBT Common-Base Amplifier for 172 GHz; Modular, Microprocessor-Controlled Flash Lighting System; Generic Environment for Simulating Launch Operations; Modular Aero-Propulsion System Simulation; X-Windows Socket Widget Class; Infrastructure for Rapid Development of Java GUI Programs; Processing Raman Spectra of High-Pressure Hydrogen Flames; X-Windows Information Sharing Protocol Widget Class; Simulating Humans as Integral Parts of Spacecraft Missions; Analyzing Power Supply and Demand on the ISS; Polyimides From a-BPDA and Aromatic Diamines; Making Plant-Support Structures From Waste Plant Fiber; Large Deployable Reflectarray Antenna; Periodically Discharging, Gas-Coalescing Filter; Ion Milling On Steps for Fabrication of Nanowires; Neuro-Prosthetic Implants With Adjustable Electrode Arrays; Microfluidic Devices for Studying Biomolecular Interactions; Studying Functions of All Yeast Genes Simultaneously; Polarization Phase-Compensating Coats for Metallic Mirrors; Tunable-Bandwidth Filter System; Methodology for Designing Fault-Protection Software; and Ground-Based Localization of Mars Rovers.

Source record↗

Sea level static calibration of a compact multimission aircraft propulsion simulator with inlet flow distortion

Wind tunnel tests of propulsion-integrated aircraft models have identified inlet flow distortion as a major source of compressor airflow measurement error in turbine-powered propulsion simulators. Consequently, two Compact Multimission Aircraft Propulsion Simulator (CMAPS) units were statically tested at sea level ambient conditions to establish simulator operating performance characteristics and to calibrate the compressor airflow against an accurate bellmouth flowmeter in the presence of inlet flow distortions. The distortions were generated using various-shaped wire mesh screens placed upstream of the compressor. CMAPS operating maps and performance envelopes were obtained for inlet total pressure distortions (ratio of the difference between the maximum and minimum total pressures to the average total pressure) up to 35 percent, and were compared to baseline simulator operating characteristics for a uniform inlet. Deviations from CMAPS baseline performance were attributed to the coupled variation of both compressor inlet-flow distortion and Reynolds number index throughout the simulator operating envelope for each screen configuration. Four independent methods were used to determine CMAPS compressor airflow; direct compressor inlet and discharge measurements, an entering/exiting flow-balance relationships, and a correlation between the mixer pressure and the corrected compressor airflow. Of the four methods, the last yielded the least scatter in the compressor flow coefficient, approximately + or - 3 percent over the range of flow distortions.

Won, Mark J.↗

Timing control system

A timing control system is disclosed which is particularly useful in connection with simulated mortar shells. Special circuitry is provided to assure that the shell does not overshoot, but rather detonates early in case of an improper condition; this ensures that ground personnel will not be harmed by a delayed detonation. The system responds to an externally applied frequency control code which is configured to avoid any confusion between different control modes. A premature detonation routine is entered in case an improper time-setting signal is entered, or if the shell is launched before completion of the time-setting sequence. Special provisions are also made for very early launch situations and improper detonator connections. An alternate abort mode is provided to discharge the internal power supply without a detonation in a manner that can be externally monitored, thereby providing a mechanism for non-destructive testing. The abort mode also accelerates the timing function for rapid testing.

Wiker, Gordon A.↗

Timing Control System

A timing control system is disclosed which is particularly useful in connection with simulated mortar shells. Special circuitry is provided to assure that the shell does not over shoot, but rather detonates early in case of an improper condition; this ensures that ground personnel will not be harmed by a delayed detonation. The system responds to an externally applied frequency control code which is configured to avoid any confusion between different control modes. A premature detonation routine is entered in case an improper time-setting signal is entered, or if the shell is launched before completion of the time-setting sequence. Special provisions are also made for very early launch situations and improper detonator connections. An alternate abort mode is provided to discharge the internal power supply without a detonation in a manner that can be externally monitored, thereby providing a mechanism for non-destructive testing. The abort mode also accelerates the timing function for rapid testing.

Wiker, Gordon A.↗

Experimental and analytical study of close-coupled ventral nozzles for ASTOVL aircraft

Flow in a generic ventral nozzle system was studied experimentally and analytically with a block version of the PARC3D computational fluid dynamics program (a full Navier-Stokes equation solver) in order to evaluate the program's ability to predict system performance and internal flow patterns. For the experimental work a one-third-size model tailpipe with a single large rectangular ventral nozzle mounted normal to the tailpipe axis was tested with unheated air at steady-state pressure ratios up to 4.0. The end of the tailpipe was closed to simulate a blocked exhaust nozzle. Measurements showed about 5 1/2 percent flow-turning loss, reasonable nozzle performance coefficients, and a significant aftward axial component of thrust due to flow turning loss, reasonable nozzle performance coefficients, and a significant aftward axial component of thrust due to flow turning more than 90 deg. Flow behavior into and through the ventral duct is discussed and illustrated with paint streak flow visualization photographs. For the analytical work the same ventral system configuration was modeled with two computational grids to evaluate the effect of grid density. Both grids gave good results. The finer-grid solution produced more detailed flow patterns and predicted performance parameters, such as thrust and discharge coefficient, within 1 percent of the measured values. PARC3D flow visualization images are shown for comparison with the paint streak photographs. Modeling and computational issues encountered in the analytical work are discussed.

Mcardle, Jack G.↗

Unitized Regenerative Fuel Cell System Gas Storage-Radiator Development

High-energy-density regenerative fuel cell systems that are used for energy storage require novel approaches to integrating components in order to preserve mass and volume. A lightweight unitized regenerative fuel cell (URFC) energy storage system concept is being developed at the NASA Glenn Research Center. This URFC system minimizes mass by using the surface area of the hydrogen and oxygen storage tanks as radiating heat surfaces for overall thermal control of the system. The waste heat generated by the URFC stack during charging and discharging is transferred from the cell stack to the surface of each tank by loop heat pipes, which are coiled around each tank and covered with a thin layer of thermally conductive carbon composite. The thin layer of carbon composite acts as a fin structure that spreads the heat away from the heat pipe and across the entire tank surface. Two different-sized commercial-grade composite tanks were constructed with integral heat pipes and tested in a thermal vacuum chamber to examine the feasibility of using the storage tanks as system radiators. The storage tank-radiators were subjected to different steady-state heat loads and varying heat load profiles. The surface emissivity and specific heat capacity of each tank were calculated. In the future, the results will be incorporated into a model that simulates the performance of similar radiators using lightweight, spacerated carbon composite tanks.

Burke, Kenneth A.↗