Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolution data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Raman and infrared thermometry for microsystems.

This paper compares measurements made by Raman and infrared thermometry on a SOI (silicon on insulator) bent-beam thermal microactuator. Both techniques are noncontact and used to experimentally measure temperatures along the legs and on the shuttle of the thermal microactuators. Raman thermometry offers micron spatial resolution and measurement uncertainties of {+-}10 K; however, typical data collection times are a minute per location leading to measurement times on the order of hours for a complete temperature profile. Infrared thermometry obtains a full-field measurement so the data collection time is much shorter; however, the spatial resolution is lower and calibrating the system for quantitative measurements is challenging. By obtaining thermal profiles on the same SOI thermal microactuator, the relative strengths and weaknesses of the two techniques are assessed.

42 ENGINEERING↗

Raman and infrared thermometry for microsystems.

This paper compares measurements made by Raman and infrared thermometry on a SOI (silicon on insulator) bent-beam thermal microactuator. Both techniques are noncontact and used to experimentally measure temperatures along the legs and on the shuttle of the thermal microactuators. Raman thermometry offers micron spatial resolution and measurement uncertainties of {+-}10 K; however, typical data collection times are a minute per location leading to measurement times on the order of hours for a complete temperature profile. Infrared thermometry obtains a full-field measurement so the data collection time is much shorter; however, the spatial resolution is lower and calibrating the system for quantitative measurements is challenging. By obtaining thermal profiles on the same SOI thermal microactuator, the relative strengths and weaknesses of the two techniques are assessed.

42 ENGINEERING↗

Limits on the radius and a possible atmosphere of Charon from its 1980 stellar occultation

Walker's (1980) stellar occultation data for Charon are presently fit by a model which encompasses the possibility of differential refraction by an atmosphere, followed by a sudden occultation behind Charon's limb. The 601.5-km Charon radius lower limit thus obtained may serve as a constraint in models of the mutual event data; while the model fits considered support a Charonian atmosphere of indeterminate composition, time resolution is insufficient for certainty and the data may be interpretable as indications of either a slight extinction near Charon or an entirely unidentified and unassociated effect.

Elliot, J. L.↗

Comparing range data across the slow-time dimension to correct motion measurement errors beyond the range resolution of a synthetic aperture radar

Motion measurement errors that extend beyond the range resolution of a synthetic aperture radar (SAR) can be corrected by effectively decreasing the range resolution of the SAR in order to permit measurement of the error. Range profiles can be compared across the slow-time dimension of the input data in order to estimate the error. Once the error has been determined, appropriate frequency and phase correction can be applied to the uncompressed input data, after which range and azimuth compression can be performed to produce a desired SAR image.

Doerry, Armin W↗

Data-Driven Residential Load Modeling and Validation in GridLAB-D

Accurately characterizing the impacts of high penetrations of distributed energy resources (DER) on the electric distribution system has driven modeling methods from traditional static snap shots, often representing a critical point in time (e.g., summer peak load), to quasi-static time series (QSTS) simulations capturing all the effects of variable DER, associated controls and hence, impacts on the distribution system over a given time period. Unfortunately, the high time resolution DER source and load data required for model inputs is often scarce or non-existent. This paper presents work performed within the GridLAB-D model environment to synthesize, calibrate, and validate 1-second residential load models based on measured transformer loads and physics-based models suitable for QSTS electric distribution system modeling. The modeling and validation approach taken was to create a typical GridLAB-D model home that, when replicated to represent multiple diverse houses on a single transformer, creates a statistically similar load to a measured load for a given weather input. The model homes are constructed to represent the range of actual homes on an instrumented transformer: square footage, thermal integrity, heating and cooling system definition as well as realistic occupancy schedules. House model calibration and validation was performed using the distribution transformer load data and corresponding weather. The modeled loads were found to be similar to the measured loads for four evaluation metrics: 1) daily average energy, 2) daily average and standard deviation of power, 3) power spectral density, and 4) load shape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Image Deconvolution and Point-spread Function Reconstruction with STARRED: A Wavelet-based Two-channel Method Optimized for Light-curve Extraction

We present starred, a point-spread function (PSF) reconstruction, two-channel deconvolution, and light-curve extraction method designed for high-precision photometric measurements in imaging time series. An improved resolution of the data is targeted rather than an infinite one, thereby minimizing deconvolution artifacts. In addition, starred performs a joint deconvolution of all available data, accounting for epoch-to-epoch variations of the PSF and decomposing the resulting deconvolved image into a point source and an extended source channel. The output is a high-signal-to-noise-ratio, high-resolution frame combining all data and the photometry of all point sources in the field of view as a function of time. Of note, starred also provides exquisite PSF models for each data frame. We showcase three applications of starred in the context of the imminent LSST survey and of JWST imaging: (i) the extraction of supernovae light curves and the scene representation of their host galaxy; (ii) the extraction of lensed quasar light curves for time-delay cosmography; and (iii) the measurement of the spectral energy distribution of globular clusters in the "Sparkler," a galaxy at redshift z = 1.378 strongly lensed by the galaxy cluster SMACS J0723.3-7327. starred is implemented in jax, leveraging automatic differentiation and graphics processing unit acceleration. This enables the rapid processing of large time-domain data sets, positioning the method as a powerful tool for extracting light curves from the multitude of lensed or unlensed variable and transient objects in the Rubin-LSST data, even when blended with intervening objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Imaging Fracture Networks Using Joint Seismic and Electrical Change Detection Techniques (Final Report)

During the initial phase of this SubTER project, we conducted a series of high resolution seismic imaging campaigns designed to characterize induced fractures. Fractures were emplaced using a novel explosive source, designed at Sandia National Laboratories, that limits damage to the borehole. This work provided evidence that fracture locations could be imaged at inch scales using high-frequency seismic tomography but left many fracture properties (i.e. permeability) unresolved. We present here the results of the second phase of the project, where we developed and demonstrated emerging seismic and electrical geophysical imaging technologies that characterize 1) the 3D extent and distribution of fractures stimulated from the explosive source, 2) 3D fluid transport within the stimulated fracture network through use of a contrasting tracer, and 3) fracture attributes through advanced data analysis. Focus was placed upon advancing these technologies toward near real-time acquisition and processing in order to help provide the feedback mechanism necessary to understand and control fracture stimulation and fluid flow. Results from this study include a comprehensive set of 4D cross-hole seismic and electrical data that take advantage of change detection methodologies allowing for perturbations associated with the fracture emplacement and particulate tracer to be isolated. During the testing the team also demonstrated near real-time 4D electrical resistivity tomography imaging and 4D seismic tomography using the CASSM approach with a temporal resolution approaching 1 minute. All of the data collected were used to develop methods of estimating fracture attributes from seismic data, develop methods of assimilating disparate and transient data sets to improve fracture network imaging resolution, and advance capabilities for near real-time inversion of cross-hole tomographic data. These results are illustrated here. Advancements in these areas are relevant to all situations where fracture emplacement is used for reservoir stimulation (e.g. Enhanced Geothermal Systems (EGS) and tight shale gases).

42 ENGINEERING↗

Magnetospheric impulse response for many levels of geomagnetic activity

The temporal relationship between the solar wind and magnetospheric activity has been studied using 34 intervals of high time resolution IMP 8 solar wind data and the corresponding AL auroral activity index. The median values of the AL index for each interval were utilized to rank the intervals according to geomagnetic activity level. The linear prediction filtering technique was then applied to model magnetospheric response as measured by the AL index to the solar wind input function VB(s). The linear prediction filtering routine produces a filter of time-lagged response coefficients which estimates the most general linear relationship between the chosen input and output parameters of the magnetospheric system. It is found that the filters are composed of two response pulses speaking at time lags of 20 and 60 min. The amplitude of the 60-min pulse is the larger for moderate activity levels, while the 20-min pulse is the larger for strong activity levels. A possible interpretation is that the 20-min pulse represents magnetospheric activity driven directly by solar wind coupling and that the 60-min pulse represents magnetospheric activity driven by the release of energy previously stored in the magnetotail. If this interpretation is correct, the linear filtering results suggest that both the driven and the unloading models of magnetospheric response are important facets of a more comprehensive response model.

Bargatze, L. F.↗

The 2008 Super Tuesday Tornado Outbreak: Synthetic Dual Doppler Analysis of Contrasting Tornadic Storm Types

During the Super Tuesday Tornado Outbreak on 5-6 February, a significant number of storms passed within about 40 km of WSR-88D radars. This distance, combined with the significant motion vector (from the southwest at 20-25 m per second) of relatively steady storms, is amenable to a synthetic dual Doppler analysis during the times when the storms passed the WSR-88D locations. Nine storms will be analyzed using the SDD technique. The following table provides their general characteristics and nearest approach to the 88D radars. For this data set, storm structure ranges from isolated supercell to QLCS. Each storm will be analyzed for a 40-60 min period during passage by the WSR-88D radar to determine general storm properties. Analysis of high-resolution single Doppler data around the time of passage (plus or minus 30 min), combined with 1-2 SDD analyses, will be used to examine the kinematic structure of low-level circulations (e.g., mesocyclone, downdraft) and the relation to the parent storm. This analysis may provide insights on the fundamental differences between cyclonic circulations in supercell storms and those within QCLS's.

Knupp, Kevin R.↗

Associated Particle Imaging of Neutron Inelastic Scatter: 3-D Reconstruction, Capabilities, and Challenges

Associated particle imaging (API) offers unique advantages for 3-D imaging of neutron inelastic scatter, including single-view tomographic imaging and data acquisition when access is limited to only one side of the interrogated object. However, widespread adoption of neutron inelastic scatter imaging has been impeded by several inherent challenges, most prominently spatial resolution, self-attenuation, and statistical noise. Here, in this work, the capabilities and challenges of neutron inelastic scatter imaging are investigated. Instead of focusing on a single imaging application, we identify imaging principles that hold for various neutron inelastic scatter imaging techniques. The primary challenges for 3-D imaging are characterized. The inherent spatial resolution in the time-of-flight (TOF) dimension is derived based on the known system timing resolution and scan geometry. Three reconstruction algorithms are described and demonstrated, including the introduction of modern iterative reconstruction incorporating a physics-based system model. Simulation is leveraged to demonstrate imaging capability with varying coincidence count levels and system timing resolution. An example of measured data with both back-scatter and forward-scatter detector positioning is presented. System design characteristics and their effects on image quality are identified. The imaging framework presented in this article has the potential to facilitate growth of 3-D neutron inelastic scatter API by identifying applications that are a good match for the technique and by targeting system development resources toward the requirements of a specific imaging task.

Associated particle imaging (API)↗

Simulating Visible/Infrared Imager Radiometer Suite Normalized Difference Vegetation Index Data Using Hyperion and MODIS

The success of MODIS (the Moderate Resolution Imaging Spectrometer) in creating unprecedented, timely, high-quality data for vegetation and other studies has created great anticipation for data from VIIRS (the Visible/Infrared Imager Radiometer Suite). VIIRS will be carried onboard the joint NASA/Department of Defense/National Oceanic and Atmospheric Administration NPP (NPOESS (National Polar-orbiting Operational Environmental Satellite System) Preparatory Project). Because the VIIRS instruments will have lower spatial resolution than the current MODIS instruments 400 m versus 250 m at nadir for the channels used to generate Normalized Difference Vegetation Index data, scientists need the answer to this question: how will the change in resolution affect vegetation studies? By using simulated VIIRS measurements, this question may be answered before the VIIRS instruments are deployed in space. Using simulated VIIRS products, the U.S. Department of Agriculture and other operational agencies can then modify their decision support systems appropriately in preparation for receipt of actual VIIRS data. VIIRS simulations and validations will be based on the ART (Application Research Toolbox), an integrated set of algorithms and models developed in MATLAB(Registerd TradeMark) that enables users to perform a suite of simulations and statistical trade studies on remote sensing systems. Specifically, the ART provides the capability to generate simulated multispectral image products, at various scales, from high spatial hyperspectral and/or multispectral image products. The ART uses acquired ( real ) or synthetic datasets, along with sensor specifications, to create simulated datasets. For existing multispectral sensor systems, the simulated data products are used for comparison, verification, and validation of the simulated system s actual products. VIIRS simulations will be performed using Hyperion and MODIS datasets. The hyperspectral and hyperspatial properties of Hyperion data will be used to produce simulated MODIS and VIIRS products. Hyperion-derived MODIS data will be compared with near-coincident MODIS collects to validate both spectral and spatial synthesis, which will ascertain the accuracy of converting from MODIS to VIIRS. MODIS-derived VIIRS data is needed for global coverage and for the generation of time series for regional and global investigations. These types of simulations will have errors associated with aliasing for some scene types. This study will help quantify these errors and will identify cases where high-quality, MODIS-derived VIIRS data will be available.

Ross, Kenton W.↗

Time-resolved 3D imaging of two-phase fluid flow inside a steel fuel injector using synchrotron X-ray tomography

The multiphase flow inside a diesel injection nozzle is imaged using synchrotron X-rays from the Advanced Photon Source at Argonne National Laboratory. Through acquisitions performed at several viewing angles and subsequent tomographic reconstruction, in-situ 3D visualization is achieved for the first time inside a steel injector at engine-like operating conditions. The morphology of the internal flow reveals strong flow separation and vapor-filled cavities (cavitation), the degree of which correlates with the nozzle's asymmetric inlet corner profile. Micron-scale surface features, which are artifacts of manufacturing, are shown to influence the morphology of the resulting liquid-gas interface. The data obtained at 0.1 ms time resolution exposes transient flow features and the flow development timescales are shown to be correlated with in-situ imaging of the fuel injector's hydraulically-actuated valve (needle). As more than 98.5% of the X-ray photon flux is attenuated within the steel injector body itself, we are posed with a unique challenge for imaging the flow within. Time-resolved imaging under these low-light conditions is achieved by exploiting both the refractive and absorptive properties of X-ray photons. The data-processing strategy converted these images with a signal-to-noise ratio of similar to 10 into a meaningful dataset for understanding internal flow and cavitation in a nozzle of diameter 200 mu m enclosed within 1-2 millimeters of steel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous measurement of the arrival times of x-ray photon sequence

In order to record x-ray pulse profile for x-ray pulsar-based navigation and timing, this paper presents a continuous, high-precision method for measuring arrival times of photon sequence with a common starting point. In this method, a high stability atomic clock is counted to measure the coarse time of arrival photon. A high resolution time-to-digital converter is used to measure the fine time of arrival photon. The coarse times and the fine times are recorded continuously and then transferred to computer memory by way of memory switch. The pulse profile is obtained by a special data processing method. A special circuit was developed and a low-level x-ray pulse profile measurement experiment system was setup. The arrival times of x-ray photon sequence can be consecutively recorded with a time resolution of 500 ps and the profile of x-ray pulse was constructed. The data also can be used for analysis by many other methods, such as statistical distribution of photon events per time interval, statistical distribution of time interval between two photon events, photon counting histogram, autocorrelation and higher order autocorrelation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unambiguous determination of H-atom positions: comparing results from neutron and high-resolution X-ray crystallography

The locations of H atoms in biological structures can be difficult to determine using X-ray diffraction methods. Neutron diffraction offers a relatively greater scattering magnitude from H and D atoms. Here, 1.65 {angstrom} resolution neutron diffraction studies of fully perdeuterated and selectively CH{sub 3}-protonated perdeuterated crystals of Pyrococcus furiosus rubredoxin (D-rubredoxin and HD-rubredoxin, respectively) at room temperature (RT) are described, as well as 1.1 {angstrom} resolution X-ray diffraction studies of the same protein at both RT and 100 K. The two techniques are quantitatively compared in terms of their power to directly provide atomic positions for D atoms and analyze the role played by atomic thermal motion by computing the {sigma} level at the D-atom coordinate in simulated-annealing composite D-OMIT maps. It is shown that 1.65 {angstrom} resolution RT neutron data for perdeuterated rubredoxin are {approx}8 times more likely overall to provide high-confidence positions for D atoms than 1.1 {angstrom} resolution X-ray data at 100 K or RT. At or above the 1.0{sigma} level, the joint X-ray/neutron (XN) structures define 342/378 (90%) and 291/365 (80%) of the D-atom positions for D-rubredoxin and HD-rubredoxin, respectively. The X-ray-only 1.1 {angstrom} resolution 100 K structures determine only 19/388 (5%) and 8/388 (2%) of the D-atom positions above the 1.0{sigma} level for D-rubredoxin and HD-rubredoxin, respectively. Furthermore, the improved model obtained from joint XN refinement yielded improved electron-density maps, permitting the location of more D atoms than electron-density maps from models refined against X-ray data only.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a High Resolution, Real Time, Distribution-Level Metering System and Associated Visualization, Modeling, and Data Analysis Functions

NREL is developing measurement devices and a supporting data collection network specifically targeted at electrical distribution systems to support research in this area. This paper describes the measurement network which is designed to apply real-time and high speed (sub-second) measurement principles to distribution systems that are already common for the transmission level in the form of phasor measurement units and related technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Detection Of Special Nuclear Materials Tagged Neutrons

In order to detect Special Nuclear Materials (SNM) in unattended luggage or cargo containers in the field of homeland security, fissions are induced by 14 MeV neutrons produced by an associated particle DT neutron generator, and prompt fission particles correlated with tagged neutron are detected by plastic scintillators. SMN produce high multiplicity events due to induced fissions, whereas nonnuclear materials produce low multiplicity events due to cross-talk, (n,2n) or (n,n'γ) reactions. The data acquisition electronics is made of compact FPGA boards. The coincidence window is triggered by the alpha particle detection, allowing to tag the emission date and direction of the 14 MeV interrogating neutron. The first part of the paper presents experiment vs. calculation comparisons to validate MCNP-PoliMi simulations and the post-processing tools developed with the data analysis framework ROOT. Measurements have been performed using different targets (iron, lead, graphite), first with small plastic scintillators (10 x 10 x 10 cm{sup 3}) and then with large detectors (10 x 10 x 100 cm{sup 3}) to demonstrate that nuclear materials can be differentiated from nonnuclear dense materials (iron, lead) in iron and wood matrixes. A special attention is paid on SNM detection in abandoned luggage. In the second part of the paper, the performances of a cargo container inspection system are studied by numerical simulation, following previous work reported in. Detectors dimensions and shielding against the neutron generator background are optimized for container inspection. Events not correlated to an alpha particle (uncorrelated background), counting statistics, time and energy resolutions of the data acquisition system are all taken into account in a realistic numerical model. The impact of the container matrix (iron, ceramic, wood) has been investigated by studying the system capability to detect a few kilograms of SNM in different positions in the cargo container, within 10 min acquisitions. (authors)

36 MATERIALS SCIENCE↗

Compensation of Oxygen Transmittance Effects for Proximal Sensing Retrieval of Canopy-Leaving Sun-Induced Chlorophyll Fluorescence

Estimates of Sun-Induced vegetation chlorophyll Fluorescence (SIF) using remote sensing techniques are commonly determined by exploiting solar and/or telluric absorption features. When SIF is retrieved in the strong oxygen (O2) absorption features, atmospheric effects must always be compensated. Whereas correction of atmospheric effects is a standard airborne or satellite data processing step, there is no consensus regarding whether it is required for SIF proximal-sensing measurements nor what is the best strategy to be followed. Thus, by using simulated data, this work provides a comprehensive analysis about how atmospheric effects impact SIF estimations on proximal sensing, regarding: (1) the sensor height above the vegetated canopy; (2) the SIF retrieval technique used, e.g., Fraunhofer Line Discriminator (FLD) family or Spectral Fitting Methods (SFM); and (3) the instrument's spectral resolution. We demonstrate that for proximal-sensing scenarios compensating for atmospheric effects by simply introducing the O2 transmittance function into the FLD or SFM formulations improves SIF estimations. However, these simplistic corrections still lead to inaccurate SIF estimations due to the multiplication of spectrally convolved atmospheric transfer functions with absorption features. Consequently, a more rigorous oxygen compensation strategy is proposed and assessed by following a classic airborne atmospheric correction scheme adapted to proximal sensing. This approach allows compensating for the O2 absorption effects and, at the same time, convolving the high spectral resolution data according to the corresponding Instrumental Spectral Response Function (ISRF) through the use of an atmospheric radiative transfer model. Finally, due to the key role of O2 absorption on the evaluated proximal-sensing SIF retrieval strategies, its dependency on surface pressure (p) and air temperature (T) was also assessed. we combined simulated spectral data with p and T measurements obtained for a one-year period in the Hyytiala Forestry Field Station in Finland. Of importance hereby is that seasonal dynamics in terms of T and p, if not appropriately considered as part of the retrieval strategy, can result in erroneous SIF seasonal trends that mimic those of known dynamics for temperature-dependent physiological responses of vegetation.

"sun–induced chlorophyll fluorescence (SIF); pro↗

A general spatial-temporal framework for short-term building temperature forecasting at arbitrary locations with crowdsourcing weather data

Weather forecasting has been a critical component to predict and control building energy consumption for better building energy management. Without accessibility to other data sources, the onsite observed temperatures or the airport temperatures are used in forecast models. In this paper, we present a novel approach by utilizing the crowdsourcing weather data from neighboring personal weather stations (PWS) to improve the weather forecast accuracy around buildings using a general spatial-temporal modeling framework. The final forecast is based on the ensemble of local forecasts for the target location using neighboring PWSs. Our approach is distinguished from existing literature in various aspects. First, we leverage the crowdsourcing weather data from PWS in addition to public data sources. In this way, the data is at much finer time resolution (e.g., at 5-minute frequency) and spatial resolution (e.g., arbitrary location vs grid). Second, our proposed model incorporates spatial-temporal correlation information of weather variables between the target building and a set of neighboring PWSs so that underlying correlations can be effectively captured to improve forecasting performance. Here, we demonstrate the performance of the proposed framework by comparing to the benchmark models on temperature forecasting for a building located at an arbitrary location at San Antonio, Texas, USA. In general, the proposed model framework equipped with machine learning technique such as Random Forest can improve forecasting by 50% compares with persistent model and has 90% chance to outperform airport forecast in short-term forecasting. In a real-time setting, the proposed model framework can provide more accurate temperature forecasting results compared with using airport temperature forecast for most forecast horizon. Moreover, we analyze the sensitivity of model parameters to gain insights on how crowdsourcing data from the neighboring personal weather stations impacts forecasting performance. Finally, we implement our model in other cities such as Syracuse and Chicago to test the model's performance in different landforms and climate types.

54 ENVIRONMENTAL SCIENCES↗