The emerging role of 4D synchrotron X-ray micro-tomography for climate and fossil energy studies: five experiments showing the present capabilities at beamline 8.3.2 at the Advanced Light Source

Here, continuous improvements at X-ray imaging beamlines at synchrotron light sources have made dynamic synchrotron X-ray micro-computed tomography (SXR-µCT) experiments more routinely available to users, with a rapid increase in demand given its tremendous potential in very diverse areas. In this work a survey of five different four-dimensional SXR-µCT experiments is presented, examining five different parameters linked to the evolution of the investigated system, and tackling problems in different areas in earth sciences. SXR-µCT is used to monitor the microstructural evolution of the investigated sample with the following variables: (i) high temperature, observing in situ oil shale pyrolysis; (ii) low temperature, replicating the generation of permafrost; (iii) high pressure, to study the invasion of supercritical CO 2 in deep aquifers; (iv) uniaxial stress, to monitor the closure of a fracture filled with proppant, in shale; (v) reactive flow, to observe the evolution of the hydraulic properties in a porous rock subject to dissolution. For each of these examples, it is shown how dynamic SXR-µCT was able to provide new answers to questions related to climate and energy studies, highlighting the significant opportunities opened recently by the technique.

47 OTHER INSTRUMENTATION↗

Modeling of polychromatic attenuation using computed tomography reconstructed images

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

NASA Discipline Musculoskeletal↗

Compact Beta Particle/Positron Imager for Plant Biology

The 11CO2 tracer is used to facilitate plant biology research towards optimization of plant productivity, biofuel development and carbon sequestration in biomass. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using 11CO2. Plants typically have very thin leaves resulting in little medium for the emitted positrons to undergo an annihilation event. For the emitted positron from 11C decay approximately 1mm of water equivalent material is needed for positron annihilation. Thus most of the positrons do not annihilate inside the leaf, resulting in limited sensitivity for PET imaging. To address this problem we have developed a compact beta-positive beta-minus particle (BPBM) imager for 11CO2 leaf imaging. The detector is based on a Hamamatsu H8500 position sensitive photomultiplier tube optically coupled via optical grease and a 3mm thick glass plate to a 0.5mm thick Eljin EJ-212 plastic scintillator. The detector is equipped with a flexible arm to allow its placement and orientation on the leaf of the plant of interest while maintaining the leaf's original orientation. We are planning to utilize the imaging device at the Duke University Phytotron to investigate dynamic carbon transport differences between invasive and native species.

09 BIOMASS FUELS↗

Measuring the evolution of intergalactic gas from z = 0 to 5 using the kinematic Sunyaev–Zel’dovich effect

ABSTRACT A complete census of baryons in the late Universe is a long-standing challenge due to the intermediate temperate and rarefied character of the majority of cosmic gas. To gain insight into this problem, we extract measurements of the kinematic Sunyaev–Zel’dovich (kSZ) effect from the cross-correlation of angular redshift fluctuations maps, which contain precise information about the cosmic density and velocity fields, and cosmic microwave background maps high-pass filtered using aperture photometry; we refer to this technique as angular redshift fluctuations (ARF)–kSZ tomography. Remarkably, we detect significant cross-correlation for a wide range of redshifts and filter apertures using 6dF galaxies, BOSS galaxies, and SDSS quasars as tracers, yielding a 11σ detection of the kSZ effect. We then leverage these measurements to set constraints on the location, density, and abundance of gas inducing the kSZ effect, finding that this gas resides outside dark matter haloes, presents densities ranging from 10 to 250 times the cosmic average, and comprises half of cosmic baryons. Taken together, these findings indicate that ARF–kSZ tomography provides a nearly complete census of intergalactic gas from z = 0 to 5.

Chaves-Montero, Jonás↗

Advanced Computed Tomography Inspection System (ACTIS): An overview of the technology and its application

The Advanced Computed Tomography Inspection System (ACTIS) was developed by NASA Marshall to support solid propulsion test programs. ACTIS represents a significant advance in state-of-the-art inspection systems. Its flexibility and superior technical performance have made ACTIS very popular, both within and outside the aerospace community. Through technology utilization efforts, ACTIS has been applied to inspection problems in commercial aerospace, lumber, automotive, and nuclear waste disposal industries. ACTIS has been used to inspect items of historical interest. ACTIS has consistently produced valuable results, providing information which was unattainable through conventional inspection methods. Although many successes have already been shown, the full potential of ACTIS has not yet been realized. It is currently being applied in the commercial aerospace industry by Boeing. Smaller systems, based on ACTIS technology, are becoming increasingly available. This technology has much to offer the small business and industry, especially in identifying design and process problems early in the product development cycle to prevent defects. Several options are available to businesses interested in this technology.

Hediger, Lisa H.↗

Data-centric machine learning in quantum information science

Abstract We propose a series of data-centric heuristics for improving the performance of machine learning systems when applied to problems in quantum information science. In particular, we consider how systematic engineering of training sets can significantly enhance the accuracy of pre-trained neural networks used for quantum state reconstruction without altering the underlying architecture. We find that it is not always optimal to engineer training sets to exactly match the expected distribution of a target scenario, and instead, performance can be further improved by biasing the training set to be slightly more mixed than the target. This is due to the heterogeneity in the number of free variables required to describe states of different purity, and as a result, overall accuracy of the network improves when training sets of a fixed size focus on states with the least constrained free variables. For further clarity, we also include a ‘toy model’ demonstration of how spurious correlations can inadvertently enter synthetic data sets used for training, how the performance of systems trained with these correlations can degrade dramatically, and how the inclusion of even relatively few counterexamples can effectively remedy such problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-420: Failure Effects Mode Analysis for Trigeminal Neuralgia Frameless Radiosurgery

Purpose: Functional radiosurgery has been used successfully in the treatment of trigeminal neuralgia but presents significant challenges to ensuring the high prescription dose is delivered accurately. A review of existing practice should help direct the focus of quality improvement for this treatment regime. Method: Failure modes and effects analysis was used to identify the processes in preparing radiosurgery treatment for TN. The map was developed by a multidisciplinary team including: neurosurgeon, radiation oncology, physicist and therapist. Potential failure modes were identified for each step in the process map as well as potential causes and end effect. A risk priority number was assigned to each cause. Results: The process map identified 66 individual steps (see attached supporting document). Corrective actions were developed for areas of high risk priority number. Wrong site treatment is at higher risk for trigeminal neuralgia treatment due to the lack of site specific pathologic imaging on MR and CT – additional site specific checks were implemented to minimize the risk of wrong site treatment. Failed collision checks resulted from an insufficient collision model in the treatment planning system and a plan template was developed to address this problem. Conclusion: Failure modes and effects analysis is an effective tool for developing quality improvement in high risk radiotherapy procedures such as functional radiosurgery.

60 APPLIED LIFE SCIENCES↗

Four-dimensional phase space tomography from one-dimensional measurements of a hadron beam

In this paper, we use one-dimensional measurements to infer the four-dimensional phase space density of an accumulated proton beam in the Spallation Neutron Source (SNS) accelerator. The reconstruction was performed by maximizing the distribution’s entropy subject to the measurement constraints and thus represents the most conservative inference from the data. The reconstructed distribution reproduces the measured profiles down to the noise level, and simulations indicate that the problem is reasonably well constrained. Similar measurements could serve as benchmarks for beam dynamics simulations in the SNS or hadron accelerators.

43 PARTICLE ACCELERATORS↗

Microstructure and Properties of A356 Alloy Wheels Fabricated by Low-Pressure Die Casting with Local Squeeze

The low-pressure die-casting process (LPDC) is widely used in fabricating aluminum alloy automotive wheels. With good castability and mechanical properties, A356 alloys are important and common materials for LPDC wheels. However, in practical casting process, defects often appear, especially porosities in the wheel thick-walled parts (i.e., spoke) due to inadequate interdendritic feeding, which greatly decreases the mechanical properties. In this investigation, to deal with this problem, local squeeze (LS) was added in conventional LPDC to enhance the interdendritic feeding. The practical A356 alloy wheel castings were fabricated with different LS velocities and times. The quantitative characteristics of α-Al cells, Si particles, and porosities with and without the LS analyzed by optical microscope, scanning electron microscope, and 3D x-ray computed tomography were compared. Their effects on the tensile and impact properties were discussed. The results have shown that the LS can increase the cooling rate and feed shrinkage of spoke parts, hence resulting in finer grains and denser microstructure. In result, the properties of spoke parts were improved with the LS.

36 MATERIALS SCIENCE↗

Development of computational small animal models and their applications in preclinical imaging and therapy research

The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

PhytoBeta imager: a positron imager for plant biology

Several positron emitting radioisotopes such as 11C and 13N can be used in plant biology research. The 11CO2 tracer is used to facilitate plant biology research toward optimization of plant productivity, biofuel development and carbon sequestration in biomass. Positron emission tomography (PET) imaging has been used to study carbon transport in live plants using 11CO2. Because plants typically have very thin leaves, little medium is present for the emitted positrons to undergo an annihilation event. The emitted positrons from 11C (maximum energy 960 keV) could require up to approximately 4 mm of water equivalent material for positron annihilation. Thus many of the positrons do not annihilate inside the leaf, resulting in limited sensitivity for PET imaging. To address this problem we have developed a compact beta-positive, beta-minus particle imager (PhytoBeta imager) for 11CO2 leaf imaging. The detector is based on a Hamamatsu H8500 position sensitive photomultiplier tube optically coupled via optical grease to a 0.5 mm thick Eljen EJ-212 plastic scintillator. The detector is equipped with a flexible arm to allow its placement and orientation over or under the leaf to be studied while maintaining the leaf's original orientation. To test the utility of the system the detector was used to measure carbon translocation in a leaf of the spicebush (Lindera benzoin) under two transient light conditions.

09 BIOMASS FUELS↗

Resolution-enhanced X-ray fluorescence microscopy via deep residual networks

Abstract Multimodal hard X-ray scanning probe microscopy has been extensively used to study functional materials providing multiple contrast mechanisms. For instance, combining ptychography with X-ray fluorescence (XRF) microscopy reveals structural and chemical properties simultaneously. While ptychography can achieve diffraction-limited spatial resolution, the resolution of XRF is limited by the X-ray probe size. Here, we develop a machine learning (ML) model to overcome this problem by decoupling the impact of the X-ray probe from the XRF signal. The enhanced spatial resolution was observed for both simulated and experimental XRF data, showing superior performance over the state-of-the-art scanning XRF method with different nano-sized X-ray probes. Enhanced spatial resolutions were also observed for the accompanying XRF tomography reconstructions. Using this probe profile deconvolution with the proposed ML solution to enhance the spatial resolution of XRF microscopy will be broadly applicable across both functional materials and biological imaging with XRF and other related application areas.

36 MATERIALS SCIENCE↗

Using data with models - Ill-posed problems

An attempt is made to show that the combination of data with models leads to a sequence of conventionally ill-posed problems which can be treated in a systematic and practical way by control-theory techniques. The illustrative approach is to exploit the very great mathematical simplifications which result when the methods of finite dimensional vector spaces are used, thus reducing a lot of difficult mathematics to classical least squares. The immediate motivation for this study comes from ocean acoustic tomography.

Wunsch, C.↗

Accelerating full waveform inversion via source stacking and cross-correlations

SUMMARY Accurate synthetic seismic wavefields can now be computed in 3-D earth models using the spectral element method (SEM), which helps improve resolution in full waveform global tomography. However, computational costs are still a challenge. These costs can be reduced by implementing a source stacking method, in which multiple earthquake sources are simultaneously triggered in only one teleseismic SEM simulation. One drawback of this approach is the perceived loss of resolution at depth, in particular because high-amplitude fundamental mode surface waves dominate the summed waveforms, without the possibility of windowing and weighting as in conventional waveform tomography. This can be addressed by redefining the cost-function and computing the cross-correlation wavefield between pairs of stations before each inversion iteration. While the Green’s function between the two stations is not reconstructed as well as in the case of ambient noise tomography, where sources are distributed more uniformly around the globe, this is not a drawback, since the same processing is applied to the 3-D synthetics and to the data, and the source parameters are known to a good approximation. By doing so, we can separate time windows with large energy arrivals corresponding to fundamental mode surface waves. This opens the possibility of designing a weighting scheme to bring out the contribution of overtones and body waves. It also makes it possible to balance the contributions of frequently sampled paths versus rarely sampled ones, as in more conventional tomography. Here we present the results of proof of concept testing of such an approach for a synthetic 3-component long period waveform data set (periods longer than 60 s), computed for 273 globally distributed events in a simple toy 3-D radially anisotropic upper mantle model which contains shear wave anomalies at different scales. We compare the results of inversion of 10 000 s long stacked time-series, starting from a 1-D model, using source stacked waveforms and station-pair cross-correlations of these stacked waveforms in the definition of the cost function. We compute the gradient and the Hessian using normal mode perturbation theory, which avoids the problem of cross-talk encountered when forming the gradient using an adjoint approach. We perform inversions with and without realistic noise added and show that the model can be recovered equally well using one or the other cost function. The proposed approach is computationally very efficient. While application to more realistic synthetic data sets is beyond the scope of this paper, as well as to real data, since that requires additional steps to account for such issues as missing data, we illustrate how this methodology can help inform first order questions such as model resolution in the presence of noise, and trade-offs between different physical parameters (anisotropy, attenuation, crustal structure, etc.) that would be computationally very costly to address adequately, when using conventional full waveform tomography based on single-event wavefield computations.

Romanowicz, Barbara↗

Data consistency conditions for truncated fanbeam and parallel projections

Purpose: In image reconstruction from projections, data consistency conditions (DCCs) are mathematical relationships that express the overlap of information between ideal projections. DCCs have been incorporated in image reconstruction procedures for positron emission tomography, single photon emission computed tomography, and x-ray computed tomography (CT). Building on published fanbeam DCCs for nontruncated projections along a line, the authors recently announced new DCCs that can be applied to truncated parallel projections in classical (two-dimensional) image reconstruction. These DCCs take the form of polynomial expressions for a weighted backprojection of the projections. The purpose of this work was to present the new DCCs for truncated parallel projections, to extend these conditions to truncated fanbeam projections on a circular trajectory, to verify the conditions with numerical examples, and to present a model of how DCCs could be applied with a toy problem in patient motion estimation with truncated projections. Methods: A mathematical derivation of the new parallel DCCs was performed by substituting the underlying imaging equation into the mathematical expression for the weighted backprojection and demonstrating the resulting polynomial form. This DCC result was extended to fanbeam projections by a substitution of parallel to fanbeam variables. Ideal fanbeam projections of a simple mathematical phantom were simulated and the DCCs for these projections were evaluated by fitting polynomials to the weighted backprojection. For the motion estimation problem, a parametrized motion was simulated using a dynamic version of the mathematical phantom, and both noiseless and noisy fanbeam projections were simulated for a full circular trajectory. The fanbeam DCCs were applied to extract the motion parameters, which allowed the motion contamination to be removed from the projections. A reconstruction was performed from the corrected projections. Results: The mathematical derivation revealed the anticipated polynomial behavior. The conversion to fanbeam variables led to a straight-forward weighted fanbeam backprojection which yielded the same function and therefore the same polynomial behavior as occurred in the parallel case. Plots of the numerically calculated DCCs showed polynomial behavior visually indistinguishable from the fitted polynomials. For the motion estimation problem, the motion parameters were satisfactorily recovered and ten times more accurately for the noise-free case. The reconstructed images showed that only a faint trace of the motion blur was still visible after correction from the noisy motion-contaminated projections. Conclusions: New DCCs have been established for fanbeam and parallel projections, and these conditions have been validated using numerical experiments with truncated projections. It has been shown how these DCCs could be applied to extract parameters of unwanted physical effects in tomographic imaging, even with truncated projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microfluidic technology platforms for synthesizing, labeling and measuring the kinetics of transport and biochemical reactions for developing molecular imaging probes

Radiotracer techniques are used in environmental sciences, geology, biology and medicine. Radiotracers with Positron Emission Tomography (PET) provided biological examinations of ~3 million patients 2008. Despite the success of positron labeled tracers in many sciences, there is limited access in an affordable and convenient manner to develop and use new tracers. Integrated microfluidic chips are a new technology well matched to the concentrations of tracers. Our goal is to develop microfluidic chips and new synthesis approaches to enable wide dissemination of diverse types of tracers at low cost, and to produce new generations of radiochemists for which there are many unfilled jobs. The program objectives are to: 1. Develop an integrated microfluidic platform technology for synthesizing and 18F-labeling diverse arrays of different classes of molecules. 2. Incorporate microfluidic chips into small PC controlled devices (“Synthesizer”) with a platform interfaced to PC for electronic and fluid input/out control. 3. Establish a de-centralized model with Synthesizers for discovering and producing molecular imaging probes, only requiring delivery of inexpensive [18F]fluoride ion from commercial PET radiopharmacies vs the centralized approach of cyclotron facilities synthesizing and shipping a few different types of 18F-probes. 4. Develop a position sensitive avalanche photo diode (PSAPD) camera for beta particles embedded in a microfluidic chip for imaging and measuring transport and biochemical reaction rates to valid new 18F-labeled probes in an array of cell cultures. These objectives are met within a research and educational program integrating radio-chemistry, synthetic chemistry, biochemistry, engineering and biology in the Crump Institute for Molecular Imaging. The Radiochemistry Training Program exposes PhD and post doctoral students to molecular imaging in vitro in cells and microorganisms in microfluidic chips and in vivo with PET, from new technologies for radiochemistry (macro to micro levels), biochemistry and biology to imaging principles, tracer kinetics, pharmacokinetics and biochemical assays. New generations of radiochemists will be immersed in the biochemistry and biology for which their labeled probes are being developed for assays of these processes. In this program engineers and radio-chemists integrate the principles of microfluidics and radiolabeling along with proper system design and chemistry rule sets to yield Synthesizers enabling biological and pharmaceutical scientists to develop diverse arrays of probes to pursue their interests. This progression would allow also radiochemists to focus on the further evolution of rapid, high yield synthetic reactions with new enabling technologies, rather than everyday production of radiotracers that should be done by technologists. The invention of integrated circuits in electronics established a platform technology that allowed an evolution of ideas and applications far beyond what could have been imagined at the beginning. Rather than provide a technology for the solution to a single problem, it is hoped that microfluidic radiochemistry will be an enabling platform technology for others to solve many problems. As part of this objective, another program goal is to commercialize the technologies that come from this work so that they can be provided to others who wish to use it.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Pebble Fuel Handling and Reactivity Control for Salt-Cooled High Temperature Reactors

This report documents the work completed on the X-PREX facility under NEUP Project 11- 3172. This project seeks to demonstrate the viability of pebble fuel handling and reactivity control for fluoride salt-cooled high-temperature reactors (FHRs). The research results also improve the understanding of pebble motion in helium-cooled reactors, as well as the general, fundamental understanding of low-velocity granular flows. Successful use of pebble fuels in with salt coolants would bring major benefits for high-temperature reactor technology. Pebble fuels enable on-line refueling and operation with low excess reactivity, and thus simpler reactivity control and improved fuel utilization. If fixed fuel designs are used, the power density of salt- cooled reactors is limited to 10 MW/m 3 to obtain adequate duration between refueling, but pebble fuels allow power densities in the range of 20 to 30 MW/m 3 . This can be compared to the typical modular helium reactor power density of 5 MW/m3. Pebble fuels also permit radial zoning in annular cores and use of thorium or graphite pebble blankets to reduce neutron fluences to outer radial reflectors and increase total power production. Combined with high power conversion efficiency, compact low-pressure primary and containment systems, and unique safety characteristics including very large thermal margins (>500°C) to fuel damage during transients and accidents, salt-cooled pebble fuel cores offer the potential to meet the major goals of the Advanced Reactor Concepts Development program to provide electricity at lower cost than light water reactors with improved safety and system performance.This report presents the facility description, experimental results, and supporting simulation methods of the new X-Ray Pebble Recirculation Experiment (X-PREX), which is now operational and being used to collect data on the behavior of slow dense granular flows relevant to pebble bed reactor core designs. The X-PREX facility uses novel digital x-ray tomography methods to track both the translational and rotational motion of spherical pebbles, which provides unique experimental results that can be used to validate discrete element method (DEM) simulations of pebble motion. The validation effort supported by the X-PREX facility provides a means to build confidence in analysis of pebble bed configuration and residence time distributions that impact the neutronics, thermal hydraulics, and safety analysis of pebble bed reactor cores. Experimental and DEM simulation results are reported for silo drainage, a classical problem in the granular flow literature, at several hopper angles. These studies include conventional converging and novel diverging geometries that provide additional flexibility in the design of pebble bed reactor cores. Excellent agreement is found between the X-PREX experimental and DEM simulation results. This report also includes results for additional studies relevant to the design and analysis of pebble bed reactor cores including the study of forces on shut down blades inserted directly into a packed bed and pebble flow in a cylindrical hopper that is representative of a small test reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Realizing controllable depolarization in photonic quantum-information channels

Controlling the depolarization of light is a long-standing open problem. In recent years, many demonstrations have used the polarization of single photons to encode quantum information. The depolarization of these photons is equivalent to the decoherence of the quantum information they encode. We present schemes for building various depolarizing channels with controlled properties using birefringent crystals. Three such schemes are demonstrated, and their effects on single photons are shown by quantum process tomography to be in good agreement with a theoretical model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗