Search NASA⌕ Search

SEARCH · Search NASA

Results for “transferability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Quantum state transfer in double-quantum-well devices

A Monte Carlo simulation of double-quantum-well (DQW) devices is presented in view of analyzing the quantum state transfer (QST) effect. Different structures, based on the AlGaAs/GaAs system, were simulated at 77 and 300 K and optimized in terms of electron transfer and device speed. The analysis revealed the dominant role of the impurity scattering for the QST. Different approaches were used for the optimization of QST devices and basic physical limitations were found in the electron transfer between the QWs. The maximum transfer of electrons from a high to a low mobility well was at best 20%. Negative differential resistance is hampered by the almost linear rather than threshold dependent relation of electron transfer on electric field. By optimizing the doping profile the operation frequency limit could be extended to 260 GHz.

Jakumeit, Jurgen↗

The ordnance transfer interrupter: A new type of S & A device

A discussion is given in this paper of a new approach to the Safing and Arming of aerospace ordnance systems interconnected by detonation transfer lines, in which the conventional type of S&A device normally used for this purpose is replaced by a relatively simple electro-mechanical switching device, referred to as an 'Interrupter.' In this approach the Interrupter, which is interposed in the transfer line between the system initiator and output device, is completely passive in that it contains no pyrotechnic devices or materials. Being passive (therefore, non-initiating), the Interrupter is much less hazardous to handle and install, as well as being significantly less complex and costly than conventional S&A devices containing EED's and explosive leads. Details are presented relative to the design, development and qualification, by PS/EDD, of an ordnance transfer Interrupter intended for use on a commercial launch missile. This device, which is capable of simultaneously 'switching' multiple detonation transfer lines, incorporates a rod-type rotary barrier with independent transverse apertures for each transfer line. Barrier actuation is bi-modal, i.e., the barrier can be driven from safe-to-arm or from arm-to-safe positions by independent electro-mechanical actuators. The Interrupter described also features visual and remote status monitoring provisions and, in common with range-approved conventional S&A devices, a pre-flight safety locking mechanism functioned by a removable safing key.

Greenslade, John T.↗

Common View Time Transfer Using Worldwide GPS and DMA Monitor Stations

Analysis of the on-orbit Navstar clocks and the Global Positioning System (GPS) monitor station reference clocks is performed by the Naval Research Laboratory using both broadcast and postprocessed precise ephemerides. The precise ephemerides are produced by the Defense Mapping Agency (DMA) for each of the GPS space vehicles from pseudo-range measurements collected at five GPS and at five DMA monitor stations spaced around the world. Recently, DMA established an additional site co-located with the US Naval Observatory precise time site. The time reference for the new DMA site is the DoD Master Clock. Now, for the first time, it is possible to transfer time every 15 minutes via common view from the DoD Master Clock to the 11 GPS and DMA monitor stations. The estimated precision of a single common-view time transfer measurement taken over a 15-minute interval was between 1.4 and 2.7 nanoseconds. Using the measurements from all Navstar space vehicles in common view during the 15-minute interval, typically 3-7 space vehicles, improved the estimate of the precision to between 0.65 and 1.13 nanoseconds. The mean phase error obtained from closure of the time transfer around the world using the 11 monitor stations and the 25 space vehicle clocks over a period of 4 months had a magnitude of 31 picoseconds. Analysis of the low noise time transfer from the DoD Master Clock to each of the monitor stations yields not only the bias in the time of the reference clock, but also focuses attention on structure in the behaviour of the reference clock not previously seen. Furthermore, the time transfer provides a a uniformly sampled database of 15-minute measurements that make possible, for the first time, the direct and exhaustive computation of the frequency stability of the monitor station reference clocks. To lend perspective to the analysis, a summary is given of the discontinuities in phase and frequency that occurred in the reference clock at the Master Control Station during the period covered by the analysis.

Reid, Wilson G.↗

Data and Time Transfer Using SONET Radio

The need for precise knowledge of time and frequency has become ubiquitous throughout our society. The areas of astronomy, navigation, and high speed wide-area networks are among a few of the many consumers of this type of information. The Global Positioning System (GPS) has the potential to be the most comprehensive source of precise timing information developed to date; however, the introduction of selective availability has made it difficult for many users to recover this information from the GPS system with the precision required for today's systems. The system described in this paper is a 'Synchronous Optical NetWORK (SONET) Radio Data and Time Transfer System'. The objective of this system is to provide precise time and frequency information to a variety of end-users using a two-way data and time-transfer system. Although time and frequency transfers have been done for many years, this system is unique in that time and frequency information are embedded into existing communications traffic. This eliminates the need to make the transfer of time and frequency informatio a dedicated function of the communications system. For this system SONET has been selected as the transport format from which precise time is derived. SONET has been selected because of its high data rates and its increasing acceptance throughout the industry. This paper details a proof-of-concept initiative to perform embedded time and frequency transfers using SONET Radio.

Graceffo, Gary M.↗

Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber

This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.

Moriyama, Shin-Ichi↗

Design of an Improved Heater Array to Measure Microscale Wall Heat Transfer

An improved array of microscale heaters is being developed to measure the heat transfer coefficient at many points underneath individual bubbles during boiling as a function of space and time. This heater array enables the local heat transfer from a surface during the bubble growth and departure process to be measured with very high temporal and spatial resolution, and should allow better understanding of the boiling heat transfer mechanisms by pin-pointing when and where in the bubble departure cycle large amounts of wall heat transfer occur. Such information can provide much needed data regarding the important heat transfer mechanisms during the bubble departure cycle, and can serve as benchmarks to validate many of the analytical and numerical models used to simulate boiling. The improvements to the heater array include using a silicon-on-quartz substrate to reduce thermal cross-talk between the heaters, decreased space between the heaters, increased pad sizes on the heaters, and progressive heater sizes. Some results using the present heater array are discussed.

Kim, Jungho↗

The Development of Novel, High-Flux, Heat Transfer Cells for Thermal Control in Microgravity

In order to meet the future needs of thermal management and control in space applications such as the Space Lab, new heat-transfer technology capable of much larger heat fluxes must be developed. To this end, we describe complementary numerical and experimental investigations into the fundamental fluid mechanics and heat-transfer processes involved in a radically new, self contained, heat transfer cell for microgravity applications. In contrast to conventional heat pipes, the heat transfer in this cell is based on a forced droplet evaporation process using a fine spray. The spray is produced by a novel fluidic technology recently developed at Georgia Tech. This technology is based on a vibration induced droplet atomization process. In this technique, a liquid droplet is placed on a flexible membrane and is vibrated normal to itself. When the proper drop size is attained, the droplet resonates with the surface motion of the membrane and almost immediately bursts into a shower of very fine secondary droplets. The small droplets travel to the opposite end of the cell where they impact a heated surface and are evaporated. The vapor returns to the cold end of the cell and condenses to form the large droplets that are fragmented to form the spray. Preliminary estimates show that a heat transfer cell based on this technology would have a heat-flux capacity that is an order of magnitude higher than those of current heat pipes designs used in microgravity applications.

Smith, Marc K.↗

Laboratory Studies of Thermal Energy Charge Transfer of Silicon and Iron Ions in Astrophysical Plasmas

Charge transfer at electron-volt energies between multiply charged atomic ions and neutral atoms and molecules is of considerable importance in astrophysics, plasma physics, and in particular, fusion plasmas. In the year covered by this report, several major tasks were completed. These include: (1) the re-calibration of the ion gauge to measure the absolute particle densities of H2, He, N2, and CO for our current measurements; (2) the analysis of data for charge transfer reactions of N(exp 2 plus) ion and He, H2, N2, and CO; (3) measurement and data analysis of the charge transfer reaction of (Fe(exp 2 plus) ion and H2; (4) charge transfer measurement of Fe(exp 2 plus) ion and H2; and (5) redesign and modification of the ion detection and data acquisition system for the low energy beam facility (reflection time of flight mass spectrometer) dedicated to the study of state select charge transfer.

Kwong, Victor H. S.↗

Heat Transfer Computations of Internal Duct Flows With Combined Hydraulic and Thermal Developing Length

This study investigated the Navier-Stokes computations of the surface heat transfer coefficients of a transition duct flow. A transition duct from an axisymmetric cross section to a non-axisymmetric cross section, is usually used to connect the turbine exit to the nozzle. As the gas turbine inlet temperature increases, the transition duct is subjected to the high temperature at the gas turbine exit. The transition duct flow has combined development of hydraulic and thermal entry length. The design of the transition duct required accurate surface heat transfer coefficients. The Navier-Stokes computational method could be used to predict the surface heat transfer coefficients of a transition duct flow. The Proteus three-dimensional Navier-Stokes numerical computational code was used in this study. The code was first studied for the computations of the turbulent developing flow properties within a circular duct and a square duct. The code was then used to compute the turbulent flow properties of a transition duct flow. The computational results of the surface pressure, the skin friction factor, and the surface heat transfer coefficient were described and compared with their values obtained from theoretical analyses or experiments. The comparison showed that the Navier-Stokes computation could predict approximately the surface heat transfer coefficients of a transition duct flow.

Wang, C. R.↗

Effects of Cross-Sectional Shape, Solidity, and Distribution of Heat-Transfer Coefficient on the Torsional Stiffness of Thin Wings Subjected to Aerodynamic Heating

A study has been made of the effects of varying the shape, solidity, and heat-transfer coefficient of thin wings with regard to their influence on the torsional-stiffness reduction induced by aerodynamic heating. The variations in airfoil shape include blunting, flattening, and combined blunting and flattening of a solid wing of symmetrical double-wedge cross section. Hollow double-wedge wings of constant skin thickness with and without internal webs also are considered. The effects of heat-transfer coefficients appropriate for laminar and turbulent flow are investigated in addition to a step transition along the chord from a lower to a higher constant value of heat-transfer coefficient. From the results given it is concluded that the flattening of a solid double wedge decreases the reduction in torsional stiffness while slight degrees of blunting increase the loss. The influence of chordwise variations in heat-transfer coefficient due to turbulent and laminar boundary-layer flow on the torsional stiffness of solid wings is negligible. The effect of a step transition in heat-transfer coefficient along the chord of a solid wing can, however, become appreciable. The torsional-stiffness reduction of multiweb and hollow double-wedge wings is substantially less than that calculated for a solid wing subjected to the same heating conditions.

Thomson, Robert G.↗

Heat Transfer from a Horizontal Cylinder Rotating in Oil

Measurements of the heat transfer from a horizontal cylinder rotating about its axis have been made with oil as the surrounding fluid to provide an addition to the heat-transfer results for this system heretofore available only for air. The results embrace a Prandtl number range from about 130 to 660, with Reynolds numbers up to 3 x 10(exp 4), and show an increasing dependence of free-convection heat transfer on rotation as the Prandtl number is increased by reducing the oil temperature. Some correlation of this effect, which agrees with the prior results for air, has been achieved. At higher rotative speeds the flow becomes turbulent, the free- convection effect vanishes, and the results with oil can be correlated generally with those for air and with mass-transfer results for even higher Prandtl numbers. For this system, however, the analogy calculations which have successfully related the heat transfer to the friction for pipe flows at high Prandtl numbers fail.

Seban, R. A.↗

Control System and Flexible Satellite Interaction During Orbit Transfer Maneuver

In this paper the interaction between the attitude control system and the flexible structure of an artificial satellite during orbit transfer maneuver has been investigated. The satellite was modeled by a rigid central body with one or more flexible appendages. The dynamics equations were obtained by Lagrangean approach. The flexible appendages were treated as clamped-free beam and its displacement was discretized by assumed- mode method. In order to transfer the satellite, a typical Hohmann transfer and a burn-coast-burn strategy were used and the attitude was controlled by an on-off controller. During transfer procedure a global analysis of satellite has been done, such as: performance of control system, influence of elastic response in control system, thruster firing frequency, fuel consumption and variation of orbital elements. In order to avoid the interaction with structure motion, a control system with bandwidth of one decade bellow the fundamental frequency was used. In the simulations the firing frequency was evaluated in an approximately way but kept below the fundamental frequency of the structure. The control system has kept the attitude below the specifications. As a result, the orbit transfer maneuvering has been done correctly without excessive excitation of flexible appendage.

Adenilson Roberto da Silva↗

Cirrus Cloud Radiative and Microphysical Properties from Ground Observations and In Situ Measurements During FIRE 1991 and Their Application to Exhibit Problems in Cirrus Solar Radiative Transfer Modeling

Measurements from the FIRE 1991 cirrus cloud field experiment in the central United States are presented and analyzed. The first part focuses on cirrus microphysical properties. Aircraft 2D-probe in situ data at different cloud altitudes were evaluated for cirrus cases on four different days. Also presented are simultaneous data samples from balloonborne videosondes. Only these balloonsondes could detect the smaller crystals. Their data suggest (at least for midlatitude altitudes below 10 km) that ice crystals smaller than 15 microns in size are rare and that small ice crystals not detected by 2D-probe measurements are radiatively of minor importance, as overlooked 2D-probe crystals account for about 10% of the total extinction. The second part focuses on the link between cirrus cloud properties and radiation. With cloud macrophysical properties from surface remote sensing added to the microphysical data and additional radiation measurements at the surface, testbeds for radiative transfer models were created. To focus on scattering processes, model evaluations were limited to the solar radiative transfer by comparing calculated and measured transmissions of sunlight at the surface. Comparisons under cloud-free conditions already reveal a model bias of about +45 W/sq m for the hemispheric solar downward broadband flux. This discrepancy, which is (at least in part) difficult to explain, has to be accounted for in comparisons involving clouds. Comparisons under cirrus cloud conditions identify as the major obstacle in cirrus solar radiative transfer modeling the inability of one-dimensional radiative transfer models to account for horizontal inhomogeneities. The successful incorporation of multidimensional radiative transfer effects will depend not only on better models but critically on the ability to measure and to define characteristic inhomogeneity scales of cloud fields. The relative minor error related to the microphysical treatment is in part a reflection of the improved understanding on solar scattering on ice crystals over the last decade and of the available wealth on ice-crystal size and shape data for this study. In absence of this information, uncertainties from microphysical cirrus model assumptions will remain high.

Kinne, Stefan↗

Helium Evolution from the Transfer of Helium Saturated Propellant in Space

Helium evolution from the transfer of helium saturated propellant in space is quantified to determine its impact from creating a two-phase mixture in the transfer line. The transfer line is approximately 1/2 inch in diameter and 2400 inches in length comprised of the Fluid Interconnect System (FICS), the Orbiter Propellant Transfer System (OPTS) and the International Space Station (ISS) Propulsion Module (ISSPM). The propellant transfer rate is approximately two to three gallons per minute, and the supply tank pressure is maintained at approximately 250 psig.

Nguyen, Bich N.↗

Heat Transfer Performances of Pool Boiling on Metal-Graphite Composite Surfaces

Nucleate boiling, especially near the critical heat flux (CHF), can provide excellent economy along with high efficiency of heat transfer. However, the performance of nucleate boiling may deteriorate in a reduced gravity environment and the nucleate boiling usually has a potentially dangerous characteristic in CHF regime. That is, any slight overload can result in burnout of the boiling surface because the heat transfer will suddenly move into the film-boiling regime. Therefore, enhancement of nucleate boiling heat transfer becomes more important in reduced gravity environments. Enhancing nucleate boiling and critical heat flux can be reached using micro-configured metal-graphite composites as the boiling surface. Thermocapillary force induced by temperature difference between the graphite-fiber tips and the metal matrix, which is independent of gravity, will play an important role in bubble detachment. Thus boiling heat transfer performance does not deteriorate in a reduced-gravity environment. Based on the existing experimental data, and a two-tier theoretical model, correlation formulas are derived for nucleate boiling on the copper-graphite and aluminum-graphite composite surfaces, in both the isolated and coalesced bubble regimes. Experimental studies were performed on nucleate pool boiling of pentane on cooper-graphite (Cu-Gr) and aluminum-graphite (Al-Gr) composite surfaces with various fiber volume concentrations for heat fluxes up to 35 W per square centimeter. It is revealed that a significant enhancement in boiling heat transfer performance on the composite surfaces is achieved, due to the presence of micro-graphite fibers embedded in the matrix. The onset of nucleate boiling (the isolated bubble regime) occurs at wall superheat of about 10 C for the Cu-Gr surface and 15 C for the Al-Gr surface, much lower than their respective pure metal surfaces. Transition from an isolated bubble regime to a coalesced bubble regime in boiling occurs at a superheat of about 14 C on Cu-Gr surface and 19 C on Al-Gr surface.

Zhang, Nengli↗

Turbulent Heat Transfer Characteristics in the Shear Layer of a Separated Flow

Experiments were performed to study the evolution of the heat transfer structure in a separated free shear layer region of an incompressible separated turbulent boundary layer flow behind a backward-facing step. While there is an abundance of velocity field measurements of separated flows, heat transfer measurements are rather scarce, thus limiting assessment of the heat transfer physics and its accurate modeling. The purpose of the paper is twofold: to improve an understanding of effects of flow separation on heat transfer characteristics, and to provide data for turbulence modeling and computation. The boundary layer upstream of the step was turbulent and fully developed. A constant temperature surface boundary condition was imposed upstream and downstream of the step for the heat transfer study. An internal mixing-layer like flow forms and grows from the step lip within the original boundary layer. The turbulent structure of the flow evolving downstream, however, does not switch immediately to that of a mixing layer over the entire shear layer thickness. Measurements of mean and fluctuating velocity and temperature fields indicate that the internal layer spreads gradually in the transverse direction while the outer part of the original boundary layer is effectively unperturbed. The results in this paper have not been previously reported.

Jovic, S.↗

Substituent and Solvent Effects on Excited State Charge Transfer Behavior of Highly Fluorescent Dyes Containing Thiophenylimidazole-Based Aldehydes

The excited state charge transfer for a series of highly fluorescent dyes containing thiophenylimidazole moiety was investigated. These systems follow the Twisted Intramolecular Charge Transfer (TICT) model. Dual fluorescence was observed for each substituted dye. X-ray structures analysis reveals a twisted ground state geometry for the donor substituted aryl on the 4 and 5 position at the imidazole ring. The excited state charge transfer was modeled by a linear solvation energy relationship using Taft's pi and Dimroth's E(sub T)(30) as solvent parameters. There is linear relation between the energy of the fluorescence transition and solvent polarity. The degree of stabilization of the excited state charge transfer was found to be consistent with the intramolecular molecular charge transfer. Excited dipole moment was studied by utilizing the solvatochromic shift method.

Santos, Javier↗

Effects of Nonequilibrium at Edge of Boundary Layer on Convective Heat Transfer to a Blunt Body

This investigation is a continuation of a previous study on nonequilibrium convective heat transfer to a blunt body. In the previous study, for relatively high Reynolds number flows, it was found that: nonequilibrium convective heat transfer to a blunt body is not strongly dependent on freestream parameters, provided that the thermochemical equilibrium is reached at the edge of boundary layer; and successful testing of convective heat transfer in an arc-jet environment is possible by duplicating the surface pressure and total enthalpy. The nonequilibrium convective heat transfer computations are validated against the results of Fay and Riddell/Goulard theory. Present work investigates low Reynolds number conditions which are typical in an actual arc-jet flow environment. One expects that there will be departures from the Fay and Riddell/Goulard result since certain assumptions of the classical theory are not satisfied. These departures are of interest because the Fay and Riddell/Goulard formulas are extensively used in arc-jet testing (e.g., to determine the enthalpy of the flow and the catalytic efficiency of heat shield materials). For practical sizes of test materials, density of the test flow (and Reynolds number) in an arc-jet is such that thermochemical equilibrium may not be reached at the edge of boundary layer. For blunt body flows of nitrogen and air, computations will be presented to show the effects of thermochemical nonequilibrium at the boundary layer edge on nonequilibrium heat transfer.

Goekcen, Tahir↗