Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental and theoretical dynamics of isoelectric focusing - Elucidation of a general separation mechanism

The transient states in isoelectric focusing were monitored using a potential gradient array detector. Electric field profiles are presented which show the formation of transient moving boundaries, as well as the approach of the steady-state distribution, during the focusing of two- and three-component systems. The results are completely consistent with corresponding computer-simulation data. The focusing process is comprised of two sequential phases, a relatively rapid separation phase and a much slower stabilizing phase. It was found that the second phase can last as much as 20 times longer than the separation of the constituents.

Thormann, W.↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordinated Control of DFIG Based Wind Farms and SGs for Improving Transient Stability

This paper proposes a coordinated control of doubly fed induction generator (DFIG)-based wind farms' (WFs) post-fault active power and synchronous generators' (SGs) tripping with the aim of improving transient stability of both the first swing and multi swings. To achieve it, the impact mechanism of the WFs' post-fault active power and SGs' tripping on the stability margin of each swing is first presented by using extended equal area criterion (EEAC). Based on this, a principle of the coordinated control is put forward. The WFs' control period is designed as six stages, and the value of post-fault active power in each stage is suggested to improve the stability of the first five swings and maintain the post-fault steady state. To decrease the tripping amount of the SGs, the SGs are tripped only when WFs' control effect is not sufficient to avoid the instability. Then, by utilizing an “online pre-decision and real-time matching”scheme, an engineering application method for the control principle is proposed, where the control procedures and detailed parameters calculation are demonstrated. The numerical simulations show that the coordinated control has a better damping effect and a less control cost (less amount of tripped SGs) than the traditional DFIG control or traditional SG tripping.

17 WIND ENERGY↗

Modular high temperature gas reactor core modeling with RELAP5-3D/PHISICS – Optimization schemes for load following

The objective of this study is to develop a 3D/NK model to study the load following operation of a Modular High-Temperature Gas-Cooled Reactor (MHTGR). The selected design is the 350 MW prismatic, graphite moderated, helium cooled thermal reactor based on the MHTGR-350 transient benchmark led by the High-Temperature Gas-Cooled Reactor (HTGR) Methods Core Simulation Group at Idaho National Laboratory (INL) in the framework of the Organization for Economic Cooperation and Development Nuclear Energy Agency (OECD/NEA). This kind of reactor usually reacts very slowly to the perturbation of the core parameters due to the large amount of graphite in the core. This kind of behavior promotes the reactor stability but on the other hand limits the reactor load-following operability. Recently advances in gas reactor designs have made load-following in gas reactors a feasible and achievable goal. Modern nuclear reactors (such as the MHTGR-350) are designed to withstand the structural stresses associated with load-following. Operating the reactor in load-following mode will inevitably reduce the load factor. Although a higher load factor means more revenue and the best usage of the fuel, following the variable energy demand will increase the maximum achievable fraction of generated nuclear power, being no more limited to the base load power generation. In general, if low impact on material aging and the safe operability are demonstrated the plant economics will be minimally affected. In order to ensure that the system can be safely operated in a load-following mode an extensively study has been carried out. Some tests with linear coolant mass flow rate change demonstrated that the reactor behavior is suitable for operation in load following mode. This assumption has been confirmed by a 4 days load following transient test in which the reactor supplied the requested power with a negligible error.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Components of the ice age circulation

The effects of ice age boundary conditions on atmospheric dynamics and regional climate patterns are investigated using four GCM simulations. Particular consideration is given to sea surface temperature-sea ice distribution, the appearance of land ice, and the increased elevation of land ice. It is observed that the ice-age sea surface temperature stabilizes the atmosphere over the oceans, increases the frequency of storm tracking through central North America, and amplifies transient eddy energy without increasing baroclinic generation. It is detected that low-elevation ice generates low pressure over eastern North America and southern Europe in winter, while increasing cloud cover and cooling the land in summer. Elevation of the ice sheets cools the land in winter, further intensifies storms off northeastern North America, induces subsidence warming downstream of the European ice sheets in summer, and increases the transient and stationary eddy energy through increased baroclinicity.

Rind, D.↗

Underwater thermomagnetic generator for remote marine thermal energy harvesting and sensing

Thermomagnetic generators offer a promising approach for sustainable power generation in remote marine environments. Here, this study presents the design, thermal modeling, and experimental validation of a passively driven underwater thermomagnetic generator developed for powering ocean observation and monitoring sensors. The generator was evaluated under varying working fluids, thermal boundary conditions, and extended operation to assess real-world applicability. Two fluids, deionized water and silicone-based Thermal C5, were tested under simulated shallow- and deep-ocean conditions. Deionized water outperformed Thermal C5, especially in colder environments (~5°C), achieving a peak output of 2.7 mW due to larger temperature gradients and enhanced convective-evaporative heat transfer. Long-duration tests revealed a transient evaporation-condensation cycle that temporarily reduced rotor immersion and performance before stabilizing. The generator powered commercial marine sensors for over 6 h without external batteries, demonstrating the viability of compact, passively cooled thermomagnetic systems for autonomous, off-grid marine sensing.

13 HYDRO ENERGY↗

Experimental fault characterization of a neural network

The effects of a variety of faults on a neural network is quantified via simulation. The neural network consists of a single-layered clustering network and a three-layered classification network. The percentage of vectors mistagged by the clustering network, the percentage of vectors misclassified by the classification network, the time taken for the network to stabilize, and the output values are all measured. The results show that both transient and permanent faults have a significant impact on the performance of the measured network. The corresponding mistag and misclassification percentages are typically within 5 to 10 percent of each other. The average mistag percentage and the average misclassification percentage are both about 25 percent. After relearning, the percentage of misclassifications is reduced to 9 percent. In addition, transient faults are found to cause the network to be increasingly unstable as the duration of a transient is increased. The impact of link faults is relatively insignificant in comparison with node faults (1 versus 19 percent misclassified after relearning). There is a linear increase in the mistag and misclassification percentages with decreasing hardware redundancy. In addition, the mistag and misclassification percentages linearly decrease with increasing network size.

Tan, Chang-Huong↗

Safety analysis of the FASt TEst reactor (FASTER) preconceptual design

Here, the FASt TEst Reactor (FASTER) plant is a sodium-cooled fast spectrum test reactor design that was developed as part of an advanced demonstration and test reactor study, and provides high levels of fast and thermal neutron flux for scientific research and development. The 120 MWe FASTER plant has been designed with extended testing capabilities in mind, while keeping the design as simple as possible in order to make it efficient and cost attractive. The main function of the reactor is to provide neutrons for irradiation testing utilizing existing proven technologies to ensure a high technology readiness level. A preliminary safety analysis was performed of the FASTER design using the fast reactor safety analysis code SAS4A/SASSYS-1 to assess the reactor's safety performance during beyond design basis accidents. Three types of transient scenarios were analyzed for the FASTER design: unprotected transient overpower, unprotected loss of heat sink, and unprotected station blackout. These transients were simulated at beginning of equilibrium cycle and end of equilibrium cycle conditions. For each transient, failures of both the primary and secondary reactor scram systems were assumed. Because of the favorable reactivity feedbacks, relatively low peak fuel, cladding, and coolant temperatures were obtained during the transients and the reactor vessel temperature remained well below the limit for ensuring structural stability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Distributed Barrier Certificates for Safe Operation of Inverter-Based Microgrids

Inverter-interfaced microgrids differ from the traditional power systems due to their lack of inertia. Vanishing timescale separation between voltage and frequency dynamics makes it critical that faster-timescale stabilizing control laws also guarantee by-construction the satisfaction of voltage limits during transients. In this article, we apply a barrier functions method to compute distributed active and reactive power setpoint control laws that certify satisfaction of voltage limits during transients. Using sum-of-squares optimization tools, we propose an algorithmic construction of these control laws. Numerical simulations are provided to illustrate the proposed method.

Kundu, Soumya↗

A pilot rating scale for evaluating failure transients in electronic flight control systems

A pilot rating scale was developed to describe the effects of transients in helicopter flight-control systems on safety-of-flight and on pilot recovery action. The scale was applied to the evaluation of hardovers that could potentially occur in the digital flight-control system being designed for a variable-stability UH-60A research helicopter. Tests were conducted in a large moving-base simulator and in flight. The results of the investigation were combined with existing airworthiness criteria to determine quantitative reliability design goals for the control system.

Hindson, William S.↗

Handling Qualities of Multirotor RPM-Controlled Electric-Vertical Take-Off and Landing (eVTOL) Aircraft for Urban Air Mobility (UAM)

A paradigm shift in rotorcraft design is being led by the prospect of propulsive forces being distributed across multiple rotors, such that each rotor can be directly driven by a dedicated electric motor. Crucially, some designers attempt to utilize these direct-drive mechanisms as the sole form of primary flight control. The feasibility of this design choice remains to be proven at the scales required for passenger transport. The paper presents a preliminary handling qualities analysis, for a six-passenger (1,200 lb payload) electric Hexacopter conceptual design, which shows that Level 1 handling qualities for limited agility operations are possible, provided that electric powertrains can deliver transient peak torques twice as high as the rated continuous torque of the conceptual design. Preliminary predictions are then substantiated by the results from a piloted handling qualities evaluation conducted in the NASA-Ames Vertical Motion Simulator (VMS). Three eVTOL configurations (a quadrotor, a hexacopter and a lift+cruise) with flight control laws implementing different levels of stability augmentation (Attitude Command-Attitude Hold and Translational Rate Command response types) were evaluated in four low speed and hover tasks requiring various levels of agility and precision.

UAM↗

Using Lag Compensator in Orbit Feedback

Growing demand on the beam orbit stability requires higher loop gain inside the operational bandwidth. However, increasing the gain leads to the increase of the unity gain frequency and problems with systems stability due to the additional phase shifts caused by the trims (power supplies, eddy currents in vacuum chambers, etc.) and filtering of beam position data. Conventionally employed systems have 20 dB/decade slope near the unity gain providing 90 degrees phase shift which is sufficient for stability. Increase of the slope to 40 dB/decade by adding additional pole into the signal chain increases the phase shift to 180 degrees and makes system unstable. Utilizing one or more lag compensators allows to increase the gain while keeping phase margin acceptable. The paper provides more details on the proposed solution as well as simulations of how the transients will be modified.

43 PARTICLE ACCELERATORS↗

Accuracy and Efficiency of a Coupled Neutronics and Thermal Hydraulics Model

The accuracy requirements for modern nuclear reactor simulation are steadily increasing due to the cost and regulation of relevant experimental facilities. Because of the increase in the cost of experiments and the decrease in the cost of simulation, simulation will play a much larger role in the design and licensing of new nuclear reactors. Fortunately as the work load of simulation increases, there are better physics models, new numerical techniques, and more powerful computer hardware that will enable modern simulation codes to handle this larger workload. This manuscript will discuss a numerical method where the six equations of two-phase flow, the solid conduction equations, and the two equations that describe neutron diffusion and precursor concentration are solved together in a tightly coupled, nonlinear fashion for a simplified model of a nuclear reactor core. This approach has two important advantages. The first advantage is a higher level of accuracy. Because the equations are solved together in a single nonlinear system, the solution is more accurate than the traditional “operator split” approach where the two-phase flow equations are solved first, the heat conduction is solved second and the neutron diffusion is solved third, limiting the temporal accuracy to 1st order because the nonlinear coupling between the physics is handled explicitly. The second advantage of the method described in this manuscript is that the time step control in the fully implicit system can be based on the timescale of the solution rather than a stability-based time step restriction like the material Courant. Results are presented from a simulated control rod movement and a rod ejection that address temporal accuracy for the fully coupled solution and demonstrate how the fastest timescale of the problem can change between the state variables of neutronics, conduction and two-phase flow during the course of a transient.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Feed Composition on Cold-Cap Formation in Laboratory-Scale Melter - 16336

The development of advanced glass formulations is part of the plan for reducing the cost and time for treatment and vitrification of the 210,000 m{sup 3} of nuclear waste at the Hanford Site in southeastern Washington State. One property of interest in this development is melt viscosity, which has a decisive influence on the rate of glass production. In an electric melter, the conversion process from feed-to-glass above the melt pool occurs in the cold cap. At the final stage of conversion, when the glass-forming melt becomes connected, gas-evolving reactions cause foaming. The transient melt viscosity affects foam stability. Three glasses were formulated with viscosities of 1.5, 3.5, and 9.5 Pa s at 1150 deg. C by varying the SiO{sub 2} content at the expense of B{sub 2}O{sub 3}, Li{sub 2}O, and Na{sub 2}O kept at constant proportions. Cold caps were produced by charging simulated high-alumina, high-level waste feeds in a laboratory-scale melter. The spread of the feed on the cold cap during charging and the cross-sectional structure of the final cold caps were compared. The amount of the foam and the size of the bubbles increased as the viscosity increased. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PHIL Validation of Ultracapacitor Storage for Black Start Application

A deck of slides that present the modeling, and calibration to conduct PHIL test of ultracapacitor energy storage system. The PHIL test has been done while preparing for the black start field demonstration with Idaho Falls Power. Presentation is invited to the 6th International Workshop on Grid Simulator Testing of Wind Turbine Power Trains and Other Renewable Technologies.

13 HYDRO ENERGY↗

Dynamic Validation of CNN-Based Surrogate Models for Inverter-Based Resources in Open-Source Solvers

Traditionally, distribution system planning has focused on steady-state analyses, with limited consideration of dynamic behavior. However, as large or medium-scale inverter-based resources (IBRs), particularly grid-following (GFL) inverters in commercial or industry buildings, become more prevalent, understanding their dynamic impact is essential for grid planning and operation. This article presents an innovative deep-learning (DL)-approach using convolutional neural networks technique to model the GFL inverters. Developed from real grid-tied commercial IBR transient data, these dynamic DL models overcome proprietary constraints by requiring minimal knowledge of internal converter physics while maintaining high accuracy and flexibility. To demonstrate their applicability, the models were incorporated into GridLAB-D, an open-source, three-phase distribution analysis tool. This integration enables dynamic simulations of large-scale distribution networks with high IBR penetration stability analysis. Rigorous testing and validation, aligned with industry standards, confirmed the reliability and efficiency of this approach, paving the way for enhanced planning and operational assessments of modern power systems.

Deep-learning↗

Method to provide meta-stable operation of a DC microgrid comprising a pulsed load

A Hamiltonian surface shaping power flow control (HSSPFC) method is used to analyze the meta-stability and adjust pulsed power loads on a DC electric power distribution network. Pulsed power loads are nonlinear, time-variant systems that cause nonlinear limit-cycles. During the on periods of a pulsed load, the system can be in an unstable state and is damped back to stability during the off state of the load. Therefore, over the entire period of the pulse the system may only be assessed as meta-stable. As shown through simulation, HIL and hardware results, the HSSPFC method is more accurate than the other small-signal approaches, such as Eigenvalues, Nyquist, and Floquet theory, and can reveal important details about the transient responses and performance.