Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

THE RED-SEQUENCE CLUSTER SURVEY-2 (RCS-2): SURVEY DETAILS AND PHOTOMETRIC CATALOG CONSTRUCTION

The second Red-sequence Cluster Survey (RCS-2) is a {approx}1000 deg{sup 2}, multi-color imaging survey using the square-degree imager, MegaCam, on the Canada-France-Hawaii Telescope. It is designed to detect clusters of galaxies over the redshift range 0.1 {approx}< z {approx}< 1. The primary aim is to build a statistically complete, large ({approx}10{sup 4}) sample of clusters, covering a sufficiently long redshift baseline to be able to place constraints on cosmological parameters via the evolution of the cluster mass function. Other main science goals include building a large sample of high surface brightness, strongly gravitationally lensed arcs associated with these clusters, and an unprecedented sample of several tens of thousands of galaxy clusters and groups, spanning a large range of halo mass, with which to study the properties and evolution of their member galaxies. This paper describes the design of the survey and the methodology for acquiring, reducing, and calibrating the data for the production of high-precision photometric catalogs. We describe the method for calibrating our griz imaging data using the colors of the stellar locus and overlapping Two Micron All Sky Survey photometry. This yields an absolute accuracy of <0.03 mag on any color and {approx}0.05 mag in the r-band magnitude, verified with respect to the Sloan Digital Sky Survey (SDSS). Our astrometric calibration is accurate to <<0.''3 from comparison with SDSS positions. RCS-2 reaches average 5{sigma} point-source limiting magnitudes of griz = [24.4, 24.3, 23.7, 22.8], approximately 1-2 mag deeper than the SDSS. Due to the queue-scheduled nature of the observations, the data are highly uniform and taken in excellent seeing, mostly FWHM {approx}< 0.''7 in the r band. In addition to the main science goals just described, these data form the basis for a number of other planned and ongoing projects (including the WiggleZ survey), making RCS-2 an important next-generation imaging survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Extracting off-diagonal order from diagonal basis measurements

Quantum gas microscopy has developed into a powerful tool to explore strongly correlated quantum systems. However, discerning phases with topological or off-diagonal long range order requires the ability to extract these correlations from site-resolved measurements. Here, we show that a multiscale complexity measure can pinpoint the transition to and from the bond ordered wave phase of the one-dimensional extended Hubbard model with an off-diagonal order parameter, sandwiched between diagonal charge and spin density wave phases, using only diagonal descriptors. We study the model directly in the thermodynamic limit using the recently developed variational uniform matrix product states algorithm, and draw our samples from degenerate ground states related by global spin rotations, emulating the projective measurements that are accessible in experiments. Our results will have important implications for the study of exotic phases using optical lattice experiments. Published by the American Physical Society 2024

1-dimensional systems↗

TH-EF-207A-06: High-Resolution Optical-CT/ECT Imaging of Unstained Mice Femur, Brain, Spleen, and Tumor

Purpose: Optical transmission and emission computed tomography (optical-CT/ECT) provides high-resolution 3D attenuation and emission maps in unsectioned large (∼1cm{sup 3}) ex vivo tissue samples at a resolution of 12.9µm{sup 3} per voxel. Here we apply optical-CT/ECT to investigate high-resolution structure and auto-fluorescence in a range of optically cleared mice organs, including, for the first time, mouse bone (femur), opening the potential for study of bone metastasis and bone-mediated immune response. Methods: Three BALBc mice containing 4T1 flank tumors were sacrificed to obtain spleen, brain, tumor, and femur. Tissues were washed in 4% PFA, fixed in EtOH solution (for 5, 10, 10, and 2 days respectively), and then optically cleared for 3 days in BABBs. The femur was also placed in 0.25M aqueous EDTA for 15–30 days to remove calcium. Optical-CT/ECT attenuation and emission maps at 633nm (the latter using 530nm excitation light) were obtained for all samples. Bi-telecentric optical-CT was compared side-by-side with conventional optical projection tomography (OPT) imaging to evaluate imaging capability of these two rival techniques. Results: Auto-fluorescence mapping of femurs reveals vasculatures and fluorescence heterogeneity. High signals (A.U.=10) are reported in the medullary cavity but not in the cortical bone (A.U.=1). The brain strongly and uniform auto-fluoresces (A.U.=5). Thick, optically dense organs such as the spleen and the tumor (0.12, 0.46OD/mm) are reconstructed at depth without significant loss of resolution, which we attribute to the bi-telecentric optics of optical-CT. The attenuation map of tumor reveals vasculature, attenuation heterogeneity, and possibly necrotic tissue. Conclusion: We demonstrate the feasibility of optical-CT/ECT imaging of un-sectioned mice bones (femurs) and spleen with high resolution. This result, and the characterization of unstained organs, are important steps enabling future studies involving optical-CT/ECT applied to study metastasis and immunologic responses via fluorescence staining.

60 APPLIED LIFE SCIENCES↗

Consensus on Aquatic Primary Productivity Field Protocols for Satellite Validation and Model Synthesis

The NASA PACE project, in conjunction with the IOCCG, EUMETSAT, and JAXA, have initiated an Aquatic Primary Productivity working group, with the aim to develop community consensus on multiple methods for measuring aquatic primary productivity used for satellite validation and model synthesis. A workshop to commence the working group efforts was held December 05-07, 2018 at the University Space Research Association headquarters in Columbia, MD U.S.A., bringing together 26 active researchers from 16 institutions. The group discussed the primary differences, nuances, scales, uncertainties, definitions, and best practices for measurements of primary productivity derived from in situ/on-deck/laboratory radio/stable isotope incubations, dissolved oxygen concentrations (from incubations or autonomous platforms such as floats or gliders), oxygen-argon ratios, triple oxygen isotope, natural fluorescence, and FRRF/ETR/kinetic analysis. These discussions highlighted the necessity to move the community forward towards the establishment of climate-quality primary productivity measurements that follow uniform protocols, which is imperative to ensure that existing and future measurements can be compared, assimilated, and their uncertainties determined for model development and validation. The specific deliverable resulting from of this activity will be a protocol document, published in coordination with the IOCCG. This presentation will discuss the findings of the meeting, and address future activities of the working group.

Vandermeulen, Ryan A.↗

Final Report for Grant

This is the final report for this project. The major objectives were to develop full models and standard cells of CMOS silicon photomultipliers (SiPM) for neutron detection applications. Specifically, the research seeks to replace photomultiplier tubes, used in neutron detection applications, with SiPMs containing integrated readout electronics fabricated in standard CMOS processes. The detectors improve on the detection efficiency, readout speed, resolution (sensitivity), and spatial resolution of current systems. In particular, this work involved collaboration with the instrument and detector group at ORNL who build detectors based on discrete commercially available PMTs and SiPMs. The SiPM detectors developed in this work are based on Perimeter Gated Single Photon Avalanche Diodes (PGSPAD). These devices have tunable breakdown voltage which affects other performance characteristics of the detectors. The ability of the detectors to have integrated readout and tune the noise floor and dynamic range in addition to offering a method for non-uniformity compensation in a compact form significantly impacts the imaging research field and includes the nuclear sciences field, circuits and systems field in addition to varied fields such as geography and biology/medicine.

42 ENGINEERING↗

NASA Tech Briefs, January 2012

Contents of this issue are: (1) Energy-Based Tetrahedron Sensor for High-Temperature, High-Pressure Environments (2) Handheld Universal Diagnostic Sensor (3) Large-Area Vacuum Ultraviolet Sensors (4) Fiber Bragg Grating Sensor System for Monitoring Smart Composite Aerospace Structures (5) Health-Enabled Smart Sensor Fusion Technology (6) Extended-Range Passive RFID and Sensor Tags (7) Hybrid Collaborative Learning for Classification and Clustering in Sensor Networks (8) Self-Healing, Inflatable, Rigidizable Shelter (9) Improvements in Cold-Plate Fabrication (10) Technique for Radiometer and Antenna Array Calibration - TRAAC (11) Real-Time Cognitive Computing Architecture for Data Fusion in a Dynamic Environment (12) Programmable Digital Controller (13) Use of CCSDS Packets Over SpaceWire to Control Hardware (14) Key Decision Record Creation and Approval Module (15) Enhanced Graphics for Extended Scale Range (16) Debris Examination Using Ballistic and Radar Integrated Software (17) Data Distribution System (DDS) and Solar Dynamic Observatory Ground Station (SDOGS) (18) Integration Manager (19) Eclipse-Free-Time Assessment Tool for IRIS (20) Automated and Manual Rocket Crater Measurement Software (21) MATLAB Stability and Control Toolbox Trim and Static Stability Module (22) Patched Conic Trajectory Code (23) Ring Image Analyzer (24) SureTrak Probability of Impact Display (25) Implementation of a Non-Metallic Barrier in an Electric Motor (26) Multi-Mission Radioisotope Thermoelectric Generator Heat Exchangers for the Mars Science Laboratory Rover (27) Uniform Dust Distributor for Testing Radiative Emittance of Dust-Coated Surfaces (28) MicroProbe Small Unmanned Aerial System (29) Highly Stable and Active Catalyst for Sabatier Reactions (30) Better Proton-Conducting Polymers for Fuel-Cell Membranes (31) CCD Camera Lens Interface for Real-Time Theodolite Alignment (32) Peregrine 100-km Sounding Rocket Project (33) SOFIA Closed- and Open-Door Aerodynamic Analyses (34) Sonic Thermometer for High-Altitude Balloons (35) Near-Infrared Photon-Counting Camera for High-Sensitivity Observations (36) Integrated Optics Achromatic Nuller for Stellar Interferometry (37) High-Speed Digital Interferometry (38) Ultra-Miniature Lidar Scanner for Launch Range Data Collection (39) Shape and Color Features for Object Recognition Search (40) Explanation Capabilities for Behavior-Based Robot Control (41) A DNA-Inspired Encryption Methodology for Secure, Mobile Ad Hoc Networks (42) Quality Control Method for a Micro-Nano-Channel Microfabricated Device (43) Corner-Cube Retroreflector Instrument for Advanced Lunar Laser Ranging (44) Electrospray Collection of Lunar Dust (45) Fabrication of a Kilopixel Array of Superconducting Microcalorimeters with Microstripline Wiring Spacecraft Attitude Tracking and Maneuver Using Combined Magnetic Actuators (46) Coherent Detector for Near-Angle Scattering and Polarization Characterization of Telescope Mirror Coatings

Source record↗

Uniformly Ordered Binary Decision Algorithm for Benchmark Experiment Correlations in Whisper Validation

When performing a validation exercise for determining the upper subcritical limit of a nuclear criticality safety application, an analyst should select and perform a statistical analysis on a population of benchmark experiments that are neutronically similar to the application. The size of this population should be sufficiently large such that the statistical analysis has a high degree of confidence that the bias plus bias uncertainty (calculational margin) has been accurately quantified. A complication arises because many benchmark experiments share common components, leading to correlations in their measured effective multiplication factors. Correlations between benchmark experiments within the population reduces its predictive power. This motivates the need for methods that consider benchmark experiment correlations and ensure adequate statistical significance of results. The Whisper code is a statistical analysis pack- age that incorporates nuclear data sensitivity coefficients from MCNP to assess benchmark experiment similarity and then performs an extreme-value analysis to estimate the bias plus bias uncertainty. The original methodology in Whisper does not consider the effect of benchmark experiment correlations when making this estimation, and this summary proposes the uniformly ordered binary decision algorithm to address this shortcoming. The original methodology in Whisper computes similarity coefficients ck for an application compared to all benchmark experiments in its library and develops weighting factors for a selected population proportional to the ck values. The methodology can be interpreted as statistically emulating a validation exercise for a particular application where the weighting factors may be viewed as the likelihood that an analyst would include a particular benchmark experiment within the population. The effective sample size of the population is the expected or mean number of benchmark experiments in the population. The uniformly ordered binary decision algorithm identifies clusters of correlated benchmark experiments within the population and then computes adjusted weighting factors based on the magnitude of the correlation coefficients within the cluster to compute a reduced effective sample size accounting for the lower information content because of correlations. Benchmark experiments within the cluster are ordered randomly with equal probability and probabilistic decisions are made as to whether a benchmark. experiment within the cluster should treated as redundant with a previous one; if two redundant benchmark experiments are included, then the conservative worst case bias plus bias uncertainty is used and the pair is counted as a single benchmark experiment in the population. Results are provided for HEU solutions in a research version of the Whisper software using benchmark experiment correlations provided by DICE, the Database for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). These show that there can be a significant increase in the bias plus bias uncertainty because the effective sample size is reduced, and therefore the algorithm, needing to meet sample size requirements, expands the benchmark experiment population by accepting less similar benchmark experiments that would have otherwise not been included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Macro vs. Micro: Relating the Spectral Properties of Vesta and the HED Meteorite

We present the main results obtained comparing the visible-near infrared (VIS-NIR) spectra Vesta s surface with howardites, eucrites, diogenites (HED). HEDs are commonly associated with Vesta s composition based on spectral similarities. Because of such association, much effort is being made to merge the information from HEDs as well as Vestoids - with that from Vesta to characterize the lithologic diversity of the surface of this asteroid and to infer clues regarding its thermal history. However, while the HEDs are a class of meteorites well studied in the laboratory, the only spectral data available for Vesta until now were telescopic observations which are limited in terms of observation conditions, spatial resolution and Signal to Noise Ratio. The Dawn spacecraft, orbiting around Vesta since July 2011, is performing detailed observations of this body and thus improving our knowledge of its properties. Dawn s scientific payload includes an imaging spectrometer, VIR-MS, sensitive to the VIS-NIR spectral range. VIR-MS began acquiring spectra during the approach phase started in May 2011 and will continue its observations through July 2012 when the spacecraft will depart Vesta to travel to Ceres. The VIR-MS spatial resolution depends upon the mission phase (approach, survey, high altitude, low altitude). However, spectra acquired by VIR-MS have already exceeded the spatial resolution of ground-based telescopic observations, with resolution in the approach phase ranging from 2.5 up to 0.8 km/pixel. Moreover, the observations are uniformly distributed in latitude and longitude allowing us to have a global view of Vesta s crust spectral properties. Using the information provided by VIR spectra, we studied the distribution of the spectral heterogeneities on the surface and we used our findings to perform a comparison with HEDs spectra in the VIS-NIR spectral range searching for analogies and/or incompatibilities. In our analysis, we focused on a method to compare the results obtained at microscopic scale on HEDs samples and the one obtained at macroscopic scale on the surface of Vesta. Finally, we discuss our results in the context of vestan thermal history. The intent of this study is to improve our understanding of the connection between Vesta and the HED samples, which is one of the primary Dawn scientific objectives. This work is supported by an Italian Space Agency (ASI) grant and by NASA through the Dawn project and a Dawn at Vesta Participating Scientist grant.

Ammannito, E.↗

Interaction of Burning Metal Particles

Physical characteristics of the combustion of metal particle groups have been addressed in this research. The combustion behavior and interaction effects of multiple metal particles has been studied using a microgravity environment, which presents a unique opportunity to create an "aerosol" consisting of relatively large particles, i.e., 50-300 micrometer diameter. Combustion behavior of such an aerosol could be examined using methods adopted from well-developed single particle combustion research. The experiment included fluidizing relatively large (order of 100 micrometer diameter) uniform metal particles under microgravity and igniting such an "aerosol" using a hot wire igniter. The flame propagation and details of individual particle combustion and particle interaction have been studied using a high speed movie and video-imaging with cameras coupled with microscope lenses to resolve individual particles. Interference filters were used to separate characteristic metal and metal oxide radiation bands form the thermal black body radiation. Recorded flame images were digitized and employed to understand the processes occurring in the burning aerosol. The development of individual particle flames, merging or separation, and extinguishing as well as induced particle motion have been analyzed to identify the mechanisms governing these processes. Size distribution, morphology, and elemental compositions of combustion products were characterized and used to link the observed in this project aerosol combustion phenomena with the recently expanded mechanism of single metal particle combustion.

Dreizin, Edward L.↗

SU-G-IeP4-02: Application of Changs Attenuation Correction Technique for SPECT Partial Angle Acquisition of Jaszczak Phantom

Purpose: Chang’s mathematical formulation is a common method of attenuation correction applied on reconstructed Jaszczak phantom images. Though Chang’s attenuation correction method has been used for 360° angle acquisition, its applicability for 180° angle acquisition remains a question with one vendor’s camera software producing artifacts. The objective of this work is to ensure that Chang’s attenuation correction technique can be applied for reconstructed Jaszczak phantom images acquired in both 360° and 180° mode. Methods: The Jaszczak phantom filled with 20 mCi of diluted Tc-99m was placed on the patient table of Siemens e.cam™ (n = 2) and Siemens Symbia™ (n = 1) dual head gamma cameras centered both in lateral and axial directions. A total of 3 scans were done at 180° and 2 scans at 360° orbit acquisition modes. Thirty two million counts were acquired for both modes. Reconstruction of the projection data was performed using filtered back projection smoothed with pre reconstruction Butterworth filter (order: 6, cutoff: 0.55). Reconstructed transaxial slices were attenuation corrected by Chang’s attenuation correction technique as implemented in the camera software. Corrections were also done using a modified technique where photon path lengths for all possible attenuation paths through a pixel in the image space were added to estimate the corresponding attenuation factor. The inverse of the attenuation factor was utilized to correct the attenuated pixel counts. Results: Comparable uniformity and noise were observed for 360° acquired phantom images attenuation corrected by the vendor technique (28.3% and 7.9%) and the proposed technique (26.8% and 8.4%). The difference in uniformity for 180° acquisition between the proposed technique (22.6% and 6.8%) and the vendor technique (57.6% and 30.1%) was more substantial. Conclusion: Assessment of attenuation correction performance by phantom uniformity analysis illustrated improved uniformity with the proposed algorithm compared to the camera software.

60 APPLIED LIFE SCIENCES↗

Use of Historical EM Practices and Policies for Management of Cleanup Program and Address GAO Concerns - 20222

As Department of Energy (DOE) Environmental Management (EM) program policies and management practices are revised over time, it might be useful to periodically reflect on the DOE EM program's past to identify practices that have worked and those that might be appropriate for possible reuse in the future. An added impetus to examine alternative approaches is the recent Government Accountability Office (GAO) report entitled 'Nuclear Waste Cleanup - DOE Could Improve Program and Project Management by Better Classifying Work and Following Leading Practices.' The February 2019 GAO report states that EM categorizes most of its work in a way that does not adequately involve independent experts and DOE senior leadership. It also noted that EM has not followed leading practices for program and project management that could help keep the cleanup efforts on schedule and control costs. The GAO report recommended that EM, working with DOE Office of Project Management (PM): - Establish requirements and then assess EM's ongoing operations activities to determine if some activities should be reclassified as capital asset projects based on these newly established requirements. - Review and revise EM's 2017 cleanup policy to include program management leading practices related to scope, cost, schedule performance, and independent reviews. - Update the cleanup policy to require that earned value management (EVM) systems be maintained and used in a way that follows EVM best practices. - Develop a policy to ensure that work is categorized as level of effort (LOE) only in appropriate, specified circumstances, such as when work is not measurable or when measurement is impractical. - Integrate EVM data into EM's performance metrics for operations activities. To assist with improving program performance and implementing audit recommendations, this paper reviewed past successful cleanups such as Weldon Springs, Rocky Flats, Fernald, Ashtabula, Battelle Columbus (abs, and other historical resources and people with experience during the early years of EM program. As such, there are several past practices which may well be suited for reuse today. Some of these practices include: - In 1990's, as the DOE EM cleanup program, known as Environmental Restoration came into effect, the known cleanup scope at each geographic location or site was organized into four levels ranging from overall site-wide cleanup effort to the individual 'release sites', providing high granularity to the program. - The cleanup program was organized by geography (Northwest, Southwest, Eastern Area Programs, etc.). These 'sub-program' managers provided a degree of Headquarters oversight and management allowing upper management (EM-1, 2, and 3) to focus on major decisions and issues. - Budget levels at selected cleanup sites were funded above 'minimum-safety' levels to accelerate actual cleanup work. - Past practice utilized EVM techniques and uniform EM oversight over all discrete project-like activities, providing for a coordinated cleanup effort. - EM managed LOE activities using benchmarking and best in class management practice techniques to help manage costs. - EM managed and reviewed entire site cleanup baselines, not only individual projects, focusing on a successful overall outcome. - Sites had a 'Road map' or 'Management Action Plan' that provided the overall strategy or plan for that site's cleanup - this helped with understanding and coordination of efforts. - EM had a robust lessons-learned program and database to capture and transmit worthy ideas. - EM had well-structured cleanup baseline change control policies to control cost and schedule changes, at the contractor and higher Headquarters levels. Finally, some of the GAO observations may be valid, however it is not clear as to their extent. For example, for some operation types of work, the use of the Level of Effort (LOE) earned value method to track progress may be appropriate. Also, to ensure independence of thought, and to obtain useful insight on past practices, it may be suitable to have former EM employees to assist with understanding past practices or to verify that activities have been properly identified. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method and apparatus for calibrating a display using an array of cameras

The present invention overcomes many of the disadvantages of the prior art by providing a display that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, the present invention provides one or more cameras to capture an image that is projected on a display screen. In one embodiment, the one or more cameras are placed on the same side of the screen as the projectors. In another embodiment, an array of cameras is provided on either or both sides of the screen for capturing a number of adjacent and/or overlapping capture images of the screen. In either of these embodiments, the resulting capture images are processed to identify any non-desirable characteristics including any visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and/or other visible artifacts.

Johnson, Michael J.↗

$xy$ Position Reconstruction in DarkSide-50

The DarkSide-50 experiment seeks to directly detect dark matter in a liquid argon time projection chamber. In this dissertation, I present an algorithm of my design that determines the position of particle interactions with the liquid argon. This position reconstruction algorithm will be used by DarkSide-50 to reject backgrounds, particularly backgrounds from radioactive elements on the detector surface. The position reconstruction algorithm functions by constructing light response functions (LRFs) that map locations in the detector to the expected distribution of signal in DarkSide-50's 38 photomultiplier tubes. Accurate LRFs cannot be produced by simulations of DarkSide-50's optics because such simulations are known to be awed. Instead, this algorithm constructs LRFs using an iterative process driven by data. Initial, awed LRFs are produced using simulated events but then used to produce new LRFs from data events. Multiple generations of LRFs are created from data with each generation driven to better satisfy a known feature of the detector: the dominant argon-39 background is uniformly distributed. I also discuss a method of discriminating against surface background as an alternative to the common approach of ducialization. This method considers the di erence in goodnessof- t between the best- t reconstructed position and the best- t position at the detector's surface. I conclude by presenting results on the performance and validity of this algorithm, including some discussion of reconstruction errors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical and Microphysical Retrievals of Marine Stratocumulus Clouds off the Coast of Namibia from Satellite and Aircraft

Though the emphasis of the Southern Africa Regional Science Initiative 2000 (SAFARI-2000) dry season campaign was largely on emission sources and transport, the assemblage of aircraft (including the high altitude NASA ER-2 remote sensing platform and the University of Washington CV-580, UK MRF C-130, and South African Weather Bureau JRA in situ aircrafts) provided a unique opportunity for cloud studies. Therefore, as part of the SAFARI initiative, investigations were undertaken to assess regional aerosol-cloud interactions and cloud remote sensing algorithms. In particular, the latter part of the experiment concentrated on marine boundary layer stratocumulus clouds off the southwest coast of Africa. Associated with cold water upwelling along the Benguela current, the Namibian stratocumulus regime has received limited attention but appears to be unique for several reasons. During the dry season, outflow of continental fires and industrial pollution over this area can be extreme. From below, upwelling provides a rich nutrient source for phytoplankton (a source of atmospheric sulfur through DMS production as well as from decay processes). The impact of these natural and anthropogenic sources on the microphysical and optical properties of the stratocumulus is unknown. Continental and Indian Ocean cloud systems of opportunity were also studied during the campaign. SAFARI 2000 aircraft flights off the coast of Namibia were coordinated with NASA Terra Satellite overpasses for synergy with the Moderate Resolution Imaging Spectroradiometer (MODIS) and other Terra instruments. MODIS was developed by NASA and launched onboard the Terra spacecraft on December 18, 1999 (and Aqua spacecraft on May 4, 2002). Among the remote sensing algorithms developed and applied to this sensor are cloud optical and microphysical properties that include cloud thermodynamic phase, optical thickness, and effective particle radius of both liquid water and ice clouds. The archived products from these algorithms have applications in climate change studies, climate modeling, numerical weather prediction, and fundamental atmospheric research. The archived MODIS Collection 5 cloud products processing stream will be used to analyze low water cloud scenes off the Namibian and Angolan coasts during SAFARI 2000 time period, as well as other years. Pixel-level Terra and Aqua MODIS retrievals (l. km spatial resolution at nadir) and gridded (1' uniform grid) statistics of cloud optical thickness and effective particle radius will be presented, including joint probability distributions between the two quantities. In addition, perspectives from the MODIS Airborne Simulator, which flew on the ER-2 during SAFARI 2000 providing high spatial resolution retrievals (50 m at nadir), will be presented as appropriate. The H-SAF Program requires an experimental operational European-centric Satellite Precipitation Algorithm System (E-SPAS) that produces medium spatial resolution and high temporal resolution surface rainfall and snowfall estimates over the Greater European Region including the Greater Mediterranean Basin. Currently, there are various types of experimental operational algorithm methods of differing spatiotemporal resolutions that generate global precipitation estimates. This address will first assess the current status of these methods and then recommend a methodology for the H-SAF Program that deviates somewhat from the current approach under development but one that takes advantage of existing techniques and existing software developed for the TRMM Project and available through the public domain.

Platnick, Steven E.↗

Economical Fabrication of Thick-Section Ceramic Matrix Composites

A method was developed for producing thick-section [>2 in. (approx.5 cm)], continuous fiber-reinforced ceramic matrix composites (CMCs). Ultramet-modified fiber interface coating and melt infiltration processing, developed previously for thin-section components, were used for the fabrication of CMCs that were an order of magnitude greater in thickness [up to 2.5 in. (approx.6.4 cm)]. Melt processing first involves infiltration of a fiber preform with the desired interface coating, and then with carbon to partially densify the preform. A molten refractory metal is then infiltrated and reacts with the excess carbon to form the carbide matrix without damaging the fiber reinforcement. Infiltration occurs from the inside out as the molten metal fills virtually all the available void space. Densification to <5 vol% porosity is a one-step process requiring no intermediate machining steps. The melt infiltration method requires no external pressure. This prevents over-infiltration of the outer surface plies, which can lead to excessive residual porosity in the center of the part. However, processing of thick-section components required modification of the conventional process conditions, and the means by which the large amount of molten metal is introduced into the fiber preform. Modification of the low-temperature, ultraviolet-enhanced chemical vapor deposition process used to apply interface coatings to the fiber preform was also required to accommodate the high preform thickness. The thick-section CMC processing developed in this work proved to be invaluable for component development, fabrication, and testing in two complementary efforts. In a project for the Army, involving SiC/SiC blisk development, nominally 0.8 in. thick x 8 in. diameter (approx. 2 cm thick x 20 cm diameter) components were successfully infiltrated. Blisk hubs were machined using diamond-embedded cutting tools and successfully spin-tested. Good ply uniformity and extremely low residual porosity (<2 percent) were achieved, the latter being far lower than that achieved with SiC matrix composites fabricated via CVI or PIP. The pyrolytic carbon/zirconium nitride interface coating optimized in this work for use on carbon fibers was incorporated in the SiC/SiC composites and yielded a >41 ksi (approx. 283 MPa) flexural strength.

Babcock, Jason↗

Development of Electrodeposited CIGS Solar Cells: Cooperative Research and Development Final Report, CRADA Number CRD-09-357

At present, most PV materials are fabricated by vacuum technologies. Some of the many disadvantages of vacuum technology are complicated instrumentation, material waste, high cost of deposition per surface area, and instability of some compounds at the deposition temperature. Solution-based approaches for thin-film deposition on large areas are particularly desirable because of the low capital cost of the deposition equipment, relative simplicity of the processes, ease of doping, uniform deposition on a variety of substrates (including interior and exterior of tubes and various nonplanar devices), and potential compatibility with high-throughput (e.g., roll-to-roll) processing. Of the nonsilicon solar photovoltaic device modules that have been deployed to date, those based on the n-CdS/p-CdTe is a leading candidate. Two features in the optical characteristics of CdTe absorber are particularly attractive for photovoltaic conversion of sunlight; (a) its energy bandgap of 1.5 eV, which provides an optimal match with the solar spectrum and thus facilitates its efficient utilization and (b) the direct mode of the main optical transition which results in a large absorption coefficient and turn permits the use of thin layer (1-2 um) of active material. Thin films of CdTe required for these devices have been fabricated by a variety of methods (e.g., vapor transport deposition, vacuum deposition, screen printing and close-spaced sublimation). Electrodeposition is another candidate deserves more attention. This project will focus on delivering low-cost, high efficiency electrodeposited CdTe-based device.

14 SOLAR ENERGY↗

Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Validation of Quantitative Model-Based Image Reconstruction for NDE of Reinforced Steel-Lined Concrete Structures: Kal-El FY 2020

This project studied the capabilities of Model-Based Image Reconstruction (MBIR) and Machine Learning (ML) algorithms in the imaging and estimation of rebar corrosion from ultrasound signals. The application was challenging due to the introduction of a steel liner between the sensor and the concrete containing the rebar. The study focused in a synthetic specimen with a 6.35 mm thick steel liner, and a 19.05 mm diameter rebar at a depth of 44.5 mm and with four levels of corrosion; 0%, 20%, 50%, and 100% corrosion level. The corrosion was applied uniformly around the rebar, generating a ring in the perimeter of the rebar with different acoustic density. In order to generate a realistic synthetic dataset, we added random texture to the concrete of the synthetic specimens. This texture will mimic the variations encountered in real concrete specimens.We adapted our MBIR algorithm for the application and enhanced the algorithm to integrate in the physical model known specimen features, such as the steel liner thickness. The new MBIR method was able to cancel out reverberation from the steel liner and properly image the rebar. In particular, corrosion for the 50% and 100% cases were easily visible and quantitative metrics showed a slight separation for the 0% and 20% levels. The quantitative results were in agreement with the qualitative assessment. We also developed a ML XGBoost model to estimate corrosion level from the ultrasound signals. By combining the ML method with MBIR, we can pinpoint in the ultrasound signals the section that corresponds to the echoes from the rebar. The extract signals are processed by the XGBoost model for prediction. From each system scan, we obtain 15 predictions. The median prediction value is used as the final prediction. The True Acceptance Rate for the method is over 99%.

36 MATERIALS SCIENCE↗