Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Data Fusion of Very High Resolution Hyperspectral and Polarimetric SAR Imagery for Terrain Classification

Performing terrain classification with data from heterogeneous imaging modalities is a very challenging problem. The challenge is further compounded by very high spatial resolution. (In this paper we consider very high spatial resolution to be much less than a meter.) At very high resolution many additional complications arise, such as geometric differences in imaging modalities and heightened pixel-by-pixel variability due to inhomogeneity within terrain classes. In this paper we consider the fusion of very high resolution hyperspectral imaging (HSI) and polarimetric synthetic aperture radar (PolSAR) data. We introduce a framework that utilizes the probabilistic feature fusion (PFF) one-class classifier for data fusion and demonstrate the effect of making pixelwise, superpixel, and pixelwise voting (within a superpixel) terrain classification decisions. We show that fusing imaging modality data sets, combined with pixelwise voting within the spatial extent of superpixels, gives a robust terrain classification framework that gives a good balance between quantitative and qualitative results.

47 OTHER INSTRUMENTATION↗

EVSE Characterization

NextGen Profiles' EVSE characterization efforts explored performance variability in production EVSE through the use of EV emulation equipment and assessed how different operational conditions influence charging behavior. Data were collected at a frequency of 10 Hz from both the EV emulator and EVSE during each charge session and stored in a time-series database for further analysis. As part of the NextGen Profiles project, characterization of high-power EVSE was performed on both conductive and wireless charging infrastructure; however, only conductive charging data are currently included in this repository. This EVSE characterization was performed over a range of DC output currents and voltages, covering both nominal and off-nominal test conditions. This EVSE characterization dataset includes high-power charging data from two types of 350-kW-capable EVSE using liquid-cooled Combined Charging System-1 (CCS1, North American version) cables and connectors. To protect confidentiality, all EVSE metadata are anonymized, and the publicly released datasets are metered at 10-Hz frequency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pushing the Limits of High-speed X-ray Tomography to See the Unknown

First-of-their kind datasets from a high-speed X-ray tomography system were collected, and a novel numerical effort utilizing temporal information to reduce measurement uncertainty was shown. The experimental campaign used three high-speed X-ray imaging systems to collect data at 100 kHz of a scene containing high-velocity objects. The scene was a group of known objects propelled by a 12-gauge shotgun shell reaching speeds of hundreds of meters per second. These data represent a known volume where the individual components are known, with experimental uncertainties that can be used for reconstruction algorithm validation. The numerical effort used synthetic volumes in MATLAB to produce projections along known lines of sight to perform tomographic reconstructions. These projections and reconstructions were performed on a single object at two orientations, representing two timesteps, to increase the reconstruction accuracy.

36 MATERIALS SCIENCE↗

2022 Component Innovation Awardee: Pecos Wind Power

Distributed wind energy systems supply electricity for nearby homes and businesses, often in remote and rural regions. Systems capable of capturing energy in areas with low wind speeds make it possible to deploy these clean energy systems in many geographic locations. Pecos Wind Power's 85-kilowatt (kW) horizontal-axis PW85 wind turbine shows potential to reduce the levelized cost of energy by approximately 55% when compared to typical small wind systems while achieving utility-scale capacity factors of more than 40% in areas with lower wind speeds. To maximize cost competitiveness, the Pecos Wind Power turbine needs a blade optimized for low wind speeds. Through its 2022 Competitiveness Improvement Project (CIP) award, Pecos Wind Power and partner Wetzel Wind Energy Services will model, optimize, fabricate, and validate a 14.5-meter wind turbine blade made specifically for these applications. Three prior CIP awards supported Pecos Wind Power's initial development of the PW85 turbine.

CIP↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50 W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaN-based DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications: Preprint

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaNbased DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

SULI Internship Deliverables (Flow Orifice Design: Measuring Degas Flow of Experiment Loops at the Advanced Test Reactor)

These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Long-term cyclability of Li 4 Ti 5 O 12 /LiMn 2 O 4 cells using carbonate-based electrolytes for behind-the-meter storage applications

Li 4 Ti 5 O 12 /LiMn 2 O 4 (LTO/LMO) chemistry was evaluated as a potential candidate for behind-the-meter storage (BTMS) applications. Its long-term cycle performance at 45 °C was tested using ethylene carbonate (EC) and propylene carbonate (PC) solvent electrolytes. Over 1000 cycles, LTO/LMO cells exhibited ~80% capacity retention and Coulombic efficiency higher than 99.96%. Electrochemical test results showed the major degradation mode of LTO/LMO cells arises from continuous electrolyte decomposition at the LTO anode and loss of Li inventory. EC and PC electrolytes created distinct surface layers, where the EC reduction products were more effective in passivating the LTO electrode surface. Dissolution and migration of Mn from the cathode was probed as Mn 2+ species distributed throughout the surface layer at the anode. By utilizing a prelithiated LTO electrode, the LTO/LMO cell performance was significantly enhanced with EC electrolyte. On the other hand, PC electrolyte resulted in accelerated electrolyte decomposition at the lithiated LTO surface due to the lack of surface passivation. Thus, mitigating parasitic reactions at the LTO electrode is the key to developing successful LTO/LMO cells.

25 ENERGY STORAGE↗

NOvA Sterile Neutrino Search with Additional Systematic Constraints

The NOvA experiment measures neutrino oscillations in a nearly pure muon neutrino beam. The neutral current (NC) and the muon neutrino charged current (CC) interaction disappearance are studied to search for active-to-sterile neutrino oscillations. NOvA consists of two functionally identical detectors placed 14 mrad off-axis of the Fermi National Accelerator Laboratory's NuMI beamline. The Near Detector (ND) is located 100 meters underground on-site at Fermilab, while the Far Detector (FD) is situated on the surface 810 kilometers away at Ash River, Minnesota. The NuMI beam is capable of operating in either forward or reverse horn current modes, producing predominantly neutrino or antineutrino beams, respectively. For this analysis, a simultaneous near and far detector joint fit approach was utilized. Systematic uncertainties constrain the ND while the statistical uncertainties constrain the FD. In addition to the dual baseline approach, the neutrino-on-electron elastic scattering sample was included. This interaction is advantageous as it is subject to minimal cross-section uncertainties, which will help reduce degeneracies between other uncertainty categories. This thesis presents the sterile neutrino oscillation sensitivity results using 27.2e+20 POT in FHC mode, 12.6e+20 in RHC mode, with the nu-on-e sample of 13.6e+20 POT in FHC.

Oh, Haejun [Cincinnati U.]↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Equilibrium Core Model for Micro Pebble Bed Reactors Using OpenMC

Estimating the equilibrium state for pebble bed reactors (PBRs) presents complex challenges as it requires simultaneous consideration of changes in the pebbles’ movement as well as their fuel compositions. Whereas traditional approaches use multigroup diffusion codes for neutronics calculations of PBRs’ equilibrium state, the double-heterogeneity of PBRs complicates neutron cross-section generation. Continuous-energy Monte Carlo (MC) methods are better suited for detailed PBR analysis because of their natural handling of double-heterogeneity, but they demand substantially more computational resources. Here, this study introduces a novel method for efficiently estimating the equilibrium state in small and micro PBRs with reduced computational cost. The method is anticipated to accelerate the processes of core design and performing parametric studies for utilizing advanced fuel and structural materials. The HTR-10 reactor design was used for validating the method’s predictions and evaluating its computational efficiency. When compared to reference calculation values from the literature, criticality (k-effective) was predicted to be approximately within the margin of error of the MC transport calculation, average core power density (in megawatts per cubic meter) was predicted within 2.5% relative error, and maximum thermal flux (10 13 n/cm 2 .s −1 ) was predicted within 1.8% relative error. The calculated inventory of fission products and fuel composition in the equilibrium core were within 15% and 16.6%, respectively, when compared to reported values from the literature. The difference is attributed to variance in the considered values of the core temperature, which was found to significantly affect the depletion analyses.

Equilibrium core↗

Dataset for: Rooftop solar and energy storage programs can remediate energy-limiting behaviors of energy insecure households

Energy insecurity affects most low-income households in the United States. Energy insecurity, which is characterized by a household’s inability to afford their energy needs, often leads to risky choices, causing other forms of insecurity including food and health. Although there are government programs designed to provide relief to low-income households that face energy insecurity, eligibility for these programs is usually determined by household income, and those with incomes close to the threshold face uncertainty or may be left out. In many cases, these households turn to energy-limiting behaviors as a strategy to lower their electric utility bills. This paper explores the relationship between energy insecurity and energy-limiting behaviors to investigate alternative solutions that target the households that may fall out of available energy assistance programs. We explore the role of battery energy storage systems and rooftop solar photovoltaics in improving energy affordability. The results show that residential rooftop solar and behind-the-meter energy storage can offset two-thirds of the bill savings that households attain through energy-limiting behavior. Household renewable energy systems could complement existing energy assistance programs to provide long-term bill relief, enabling occupants to live in their homes with comfort and dignity. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit.

Kerby, Jessica [Pacific Northwest National Laborat↗

Cybersecurity Guide for Distributed Wind

Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This document is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). We discuss common distributed wind architectures and describe their role in the larger power system, pointing out some of the key connections to be aware of. Cybersecurity cannot exist in a vacuum, but rather must consider all the system and all its connections holistically. The role of distributed wind and the functions it can serve are described to gain understanding of the full range of capabilities. The purpose and application of relevant standards that may apply to certain distributed wind systems is presented. These standards may not apply to all installations, but even for systems that are not required to meet these standards they can be a good reference for best practices. A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). Finally, we present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Cybersecurity Guide for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This presentation is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Improving the economics of battery storage for industrial customers: Are incentives enough to increase adoption?

As adoption of behind-the-meter battery energy storage increases across the United States, implementation continues to lag in the industrial sector. This analysis considers two manufacturing facilities with potential for load shifting to reduce peak demand. Although both facilities have load profiles that demonstrate great potential for regular and programmed demand reduction during peak hours, battery energy storage was deemed prohibitively expensive. A review of several existing utility and state-level policies and incentives determined that few may be rightsized for the industrial customer class. Furthermore, this analysis further considers multiple incentive structures and finds that although incentives increase viability of energy storage, developers must also consider optimization, unique load profiles, and use case to effectively increase adoption of battery energy storage by industrial customers.

25 ENERGY STORAGE↗

Simulation-Guided Decision-Making for Enhancing Energy Resilience in a Remote Alaskan Community

The increasing frequency and severity of extreme weather events underscore the need to bolster the resilience of energy infrastructure in remote coastal communities exposed to climate hazards. In recent years, considerable effort has been made to harden the grid infrastructure of remote communities through investment in energy storage, advanced metering, renewable generation and energy-efficient loads. However, simulation-based studies are still needed to identify appropriate locations for investment and determine the adequacy of existing infrastructure in supporting new resources. Preparing the required models may often be challenging due to insufficient metering, disparate data sources and workforce limitations. This paper describes modeling efforts undertaken to represent, within a unified co-simulation platform: (a) the electric distribution network and (b) the thermal behavior of a community medical center, in the remote community of Cordova, Alaska. With the help of case-studies, it is shown how the developed simulation platform can help the local utility in making decisions regarding capital investment aimed at enhancing community resilience.

Microgrid, energy storage, resilience↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗