Search NASA⌕ Search

SEARCH · Search NASA

Results for “ventilators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Are Ventilation Filters Degrading Indoor Air Quality in California Classrooms?

Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects studenthealth and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air?conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone deposition in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent towhich filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mine Ventilation Rate Monitoring Annual Report

Module IV of the Waste Isolation Pilot Plant (WIPP) Hazardous Waste Facility Permit (HWFP) requires WIPP to develop and implement a mine ventilation flow rate monitoring plan (MVRMP). The MVRMP requires ventilation flow rate measurements for the total underground repository and each active disposal room to ensure that the airflows meet HWFP conditions. HWFP Condition IV.F.4.b requires that an annual report be submitted, beginning 12 (twelve) months after the issuance of the permit, that describes the implementation of the MVRMP and presents the results of the monitoring activities. This document was prepared to fulfill the annual reporting requirement for the period from July 1, 2007, to June 30, 2008

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mine Ventilation Rate Monitoring Annual Report

Module IV of the Waste Isolation Pilot Plant (WIPP) Hazardous Waste Facility Permit (HWFP) requires WIPP to develop and implement a mine ventilation flow rate monitoring plan (MVRMP). The MVRMP requires ventilation flow rate measurements for the total underground repository and each active disposal room to ensure that the airflows meet HWFP conditions. HWFP Condition IV.F.4.b requires that an annual report be submitted, beginning 12 (twelve) months after the issuance of the permit, that describes the implementation of the MVRMP and presents the results of the monitoring activities. This document was prepared to fulfill the annual reporting requirement for the period from July 1, 2008, to June 30, 2009.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS -TBACT- DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEMS SUPPORTING WASTE TRANSFER OPERATIONS

This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste through the DST storage system to the Waste Treatment and Immobilizaiton Plant (WTP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EVALUATION OF BEST AVAILABLE CONTROL TECHNOLOGY FOR TOXICS (TBACT) DOUBLE SHELL TANK FARMS PRIMARY VENTILATION SYSTEM SUPPORTING WASTE TRANSFER OPERATIONS

This report is an evaluation of Best Available Control Technology for Toxics (tBACT) for installation and operation of the Hanford double shell (DST) tank primary ventilation systems. The DST primary ventilation systems are being modified to support Hanford's waste retrieval, mixing, and delivery of single shell tank (SST) and DST waste throught the DST storage system to the Waste Treatment and Immobilization Plant (WTP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alveolar ventilation to perfusion heterogeneity and diffusion impairment in a mathematical model of gas exchange

This study describes a two-compartment model of pulmonary gas exchange in which alveolar ventilation to perfusion (VA/Q) heterogeneity and impairment of pulmonary diffusing capacity (D) are simultaneously taken into account. The mathematical model uses as input data measurements usually obtained in the lung function laboratory. It consists of two compartments and an anatomical shunt. Each compartment receives fractions of alveolar ventilation and blood flow. Mass balance equations and integration of Fick's law of diffusion are used to compute alveolar and blood O2 and CO2 values compatible with input O2 uptake and CO2 elimination. Two applications are presented. The first is a method to partition O2 and CO2 alveolar-arterial gradients into VA/Q and D components. The technique is evaluated in data of patients with chronic obstructive pulmonary disease (COPD). The second is a theoretical analysis of the effects of blood flow variation in alveolar and blood O2 partial pressures. The results show the importance of simultaneous consideration of D to estimate VA/Q heterogeneity in patients with diffusion impairment. This factor plays an increasing role in gas alveolar-arterial gradients as severity of COPD increases. Association of VA/Q heterogeneity and D may produce an increase of O2 arterial pressure with decreasing QT which would not be observed if only D were considered. We conclude that the presented computer model is a useful tool for description and interpretation of data from COPD patients and for performing theoretical analysis of variables involved in the gas exchange process.

NASA Discipline Environmental Health↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Report Server. This fan can be used for research and development by many organizations. The fan is 3.5 inches in diameter, 9 inches long, and weighed 3.6 lb. The NASA Quiet Space Fan was designed to make 3.64 inches of water pressure rise at 150.3 cfm of airflow at 12,000 rpm at standard air conditions of 70ºF and 14.7 psia. The performance of the metal version of the fan was measured to be 3.48 inches of water at 150.6 cfm at design speed. A low-noise blade-vane count was chosen to try to reduce tone noise generated by this fan by cutting off the first three blade passing frequency tones. In-duct microphone array measurements indicated that the most evident tones occur for frequencies of 1800 Hz (1 BPF) and 7200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This is one way that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems on spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan, noise, ventilation↗

Spacecraft Cabin Ventilation Fan Research at NASA

NASA has recently made the geometry and solid model for a spacecraft cabin ventilation fan prototype available to the public via electronic file downloads from the NASA Technical Reports Server. This fan can be used for research and development by many organizations. The NASA Quiet Space Fan is 8.89 cm (3.50 in) in diameter, 22.9 cm (9.00 in) long, and the metal fan weighs 1.63 kg (3.6 lbm). The fan was designed to generate a system total pressure rise of 906 Pa (3.64 inches of water) at 0.709 m3/s (150.3 cfm) of airflow at 12,000 rpm (at 21.1ºC (70ºF) and 14.7 psia). Performance measured using standardized techniques showed good agreement with design and predicted values. A low-noise blade-vane count was chosen to reduce tonal noise generated by rotor-stator interaction for the first three blade passing frequency harmonics. In-duct microphone array measurements indicated that the most evident tones occur at frequencies of 1,800 Hz (1 BPF) and 7,200 Hz (4 BPF). Using reverberant room standard testing methods, the A-weighted sound power level for the fan operating at design point conditions was measured to be 71 dBA. This report describes the current set of publicly available information for this fan. The fan was designed, optimized, and tested with tools and techniques that NASA has traditionally used for turbofan engine research. This demonstrates that technology developed for aerospace applications can be used more broadly, since quiet and efficient fans are needed for many ventilation systems in spacecraft, aircraft, watercraft, land vehicles, and buildings.

fan↗

Central Fan Integrated Ventilation Systems

This information sheet describes one example of a ventilation system design, a central fan integrated supply (CFIS) system, a mechanical ventilation and pollutant source control to ensure that there is reasonable indoor air quality inside the house.

Building Science Corporation↗

Technology Solutions Case Study: Impact of Infiltration and Ventilation on Measured Space Conditioning Energy and Moisture Levels in the Hot-Humid Climate

Air infiltration and ventilation in residential buildings is a very large part of the heating loads, but empirical data regarding the impact on space cooling has been lacking. Moreover, there has been little data on how building tightness might relate to building interior moisture levels in homes in a hot and humid climate. To address this need, BA-PIRC conducted research to assess the moisture and cooling load impacts of airtightness and mechanical ventilation in two identical laboratory homes in the hot-humid climate over the cooling season.

BA-PIRC↗

Building America Case Study: Energy Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates, Cocoa, Florida

In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Indoor Air and Lower Environmental Impacts: Heat Recovery Ventilation in Cold Climates

Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.

buildings↗

WIPP Safety Significant Confinement Ventilation System Design - 18490

A large exhaust ventilation system has been designed to provide continuous HEPA filtration of the exhaust from the Waste Isolation Pilot Plant (WIPP) underground while meeting the demand for expanded waste emplacement and mining operations over the next 40 years. The WIPP Safety Significant Confinement Ventilation System (SSCVS) design provides secondary confinement to mitigate the consequences of a postulated radiological release in the underground. The SSCVS design specifically addresses the radiological incident that occurred in 2014 by providing Safety Significant secondary confinement and continuous HEPA filtration over a wide range of operating and environmental conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WIPP Safety Significant Confinement Ventilation System (SSCVS) Quality Assurance Program - 20237

Construction and major equipment fabrication are underway for a new ventilation exhaust system at the Waste Isolation Pilot Plant (WIPP). The new system will provide continuous HEPA filtration of the exhaust from the WIPP underground while meeting the ventilation demands for expanded waste emplacement and mining operations over the next 40 years. The SSCVS project has proceeded with the awarding of CD-3A for Long Lead Procurements followed by CD-2/3 approval for the construction of the facilities. The SSCVS project team made the decision to increase the quality oversight throughout the complete project per the Project Quality Assurance Plan (PQAP) such that it can ensure the final products meet applicable NQA-1 requirements and general quality requirements, and that the project will proceed to operations without significant delays due to post installation quality concerns. The PQAP was established prior to approval of the project at the CD-2/3 milestone. The SSCVS project has 2 major long lead procurements which commenced with the awarding of CD-3A. These procurements include the HEPA filter housing assemblies and the Exhaust Fans. There are 22 HEPA filter assemblies for the SSCVS, which are designated Safety Significant for pressure boundary confinement, per the approved PDSA. The exhaust fans also have Safety Significant components to maintain the pressure confinement boundary. NWP made the decision to install resident Quality Inspectors at the fabrication facilities to ensure the documentation for each fabricated unit meets all the QA requirements as defined in the respective contract documents. For the construction of the SSCVS Salt Reduction Building (SRB) and New Filter Building (NFB), dedicated, on-site quality inspectors have been utilized to ensure that all work being performed will comply with quality requirements and the Special Inspections as defined in IBC-2015. At each stage of inspection, hold points are placed into the work packages to ensure NWP QA personnel are present to inspect and verify the installations are in accordance with the design specifications, codes and standards. With this level of oversight, NWP anticipates that the level of quality related issues, as seen on multiple other DOE complex site projects, will be avoided and that the commissioning, start-up and hot operations will progress in a timely fashion, as all documentation will be in place and approved prior to initiation of these activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗