Search NASA⌕ Search

SEARCH · Search NASA

Results for “visual tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Perceptual and performance consequences of flight in virtual worlds

There are two primary purposes for head-mounted systems in aeronautical settings. One is for helmet-mounted sights and teleoperated (head-slaved) weapons systems. Bennett, Johnson, Perrone, and Phatak (1988) evaluated head tracking performance during passive and controlled flight. In that study, comparisons were also made of head tracking performance in sterile and relatively complex virtual worlds. That study confirmed the robustness of head tracking performance across a wide variety of visual scenes. A second use of virtual world displays is for aircraft control. Aircraft controllability using head-mounted, panel-mounted, or simulated out-the-window scenes has been systematically examined. Those studies reported the range of rotorcraft flight tasks in which head-mounted virtual worlds provided some advantages. Two studies will be reported that examine the perceptual/performance effects of virtual worlds. The first examines head tracking performance with roll-stabilized versus non-roll stabilized virtual worlds. The purpose of the study was to (1) examine display strategies used in current display systems and (2) study the adaptability of observers to estimated glide slope angles using head-slaved versus head-stabilized imagery. The purpose of this study was to examine the usefulness of wide field-of-regards during final approaches to a runway.

Bennett, C. Thomas↗

Motion Tracking Of A Handheld Scanner With An Infrared Vision System

Handheld scanners are used in a large number of applications to inspect walls, floors, tanks, and other large structures. Measurements are made to characterize physical properties, uncover defects, detect evidence of tampering, quantify surface contamination, and so forth. Handheld scanning suffers from a number of drawbacks. The relationship between the data collected and scanned location is difficult or impossible to track. Humans using handheld scanners can unintentionally scan the same area multiple times or entirely overlook an area of interest. An automated scanner tracking system could improve upon current inspection practices with a handheld scanner in terms of efficiency, accuracy, and quality. The authors have developed a handheld scanner tracking system that will allow users to visualize previously scanned areas, highlight areas where important or unusual data are acquired, and store scanning location with acquired data. The scanned regions are saved in real time and projected back on the scanned area using a projector. The system currently utilizes the Smoothboard software, which has already been designed to interpret the location of a captured infrared source from a Wii Remote controller to create an interactive whiteboard. This software takes advantage of the Wii Remote’s ability to track the location of an infrared source, and when proper calibration of the Wii Remote orientation is complete, any surface can become a virtual whiteboard. In addition to recording and projecting scan pathways, the system developed by the authors can be used to make notes on the scanning process and project acquired data on top of the scanned area. This latter capability can be used to guide sample acquisition or demolition activities. This paper discusses development of the system and potential benefits to wall scanning with handheld scanners.

Wii Remote, Wall scanner, IR tracking, Motion Trac↗

Principles and biophysical applications of single particle super-localization and rotational tracking

While conventional Single Particle Tracking (SPT) techniques acquire 2D or 3D trajectories of particle probes, we have developed Single Particle Orientation and Rotational Tracking (SPORT) techniques to extract orientation and rotational information. Combined with DIC microscopy, the SPORT technique has been applied in biophysical studies, including membrane diffusion and intracellular transport. The rotational dynamics of nanoparticle vectors on live cell membranes was recorded and its influence on the fate of these nanoparticle vectors was elucidated. The rotational motions of gold nanorods with various surface modifiers were tracked continuously at a temporal resolution of 5 ms under a DIC microscope. We found that the rotational behaviors of gold nanorod vectors are strongly related to their surface charge, specific surface functional groups, and the availability of receptors on cell membranes. The study of rotational Brownian motion of nanoparticles on cell membranes will lead to a better understanding of the mechanisms of drug delivery and provide guidance in designing surface modification strategies for drug delivery vectors under various circumstances. To characterize the rotation mode of surface functionalized gold nanorods on cell membranes, the SPORT technique is combined with the correlation analysis of the bright and dark DIC intensities. The unique capabilities of visualizing and understanding rotational motions of functionalized nanoparticles on live cell membranes allow us to correlate rotational and translational dynamics in unprecedented detail and provide new insights for complex membrane processes, including electrostatic interactions, ligand-receptor binding, and lateral (confined and hopping) diffusion of membrane receptors. Surface-functionalized nanoparticles interact with the membrane in fundamentally different ways and exhibit distinct rotational modes. The early events of particle-membrane approach and attachment are directly visualized for the first time. The rotational dynamics of cargos in both active directional transport and pausing stages of axonal transport was also visualized using high-speed SPORT with a temporal resolution of 2 ms. Both long and short pauses are imaged, and the correlations between the pause duration, the rotational behaviour of the cargo at the pause, and the moving direction after the pause are established. Furthermore, the rotational dynamics leading to switching tracks are visualized in detail. These first-time observations of cargo's rotational dynamics provide new insights on how kinesin and dynein motors take the cargo through the alternating stages of active directional transport and pause. To improve the localization precision of the SPT technique with DIC microscopy, a precise three-dimensional (3D) localization method of spherical gold nanoparticle probes using model-based correlation coefficient mapping was introduced. To accomplish this, a stack of sample images at different z-positions are acquired, and a 3D intensity profile of the probe serving as the model is used to map out the positions of nanoparticles in the sample. By using this model-based correlation imaging method, precise localization can be achieved in imaging techniques with complicated point spread functions (PSF) such as differential interference contrast (DIC) microscopy. The 3D superlocalization method was applied to tracking gold nanospheres during live endocytosis events. Finally, a novel dual-modality imaging technique has been developed to super-localize a single gold nanorod while providing its orientation and rotational information. The super-localization of the gold nanorod can be accomplished by curve fitting the modified bright-field images generated by one of the two beams laterally shifted by the first Nomarski prism in a DIC microscope. The orientation and rotational information is derived from the DIC images of gold nanorods. The new imaging setup has been applied to study the steric hindrance induced by relatively large cargos in the microtubule gliding assay and to track nanocargos in the crowded cellular environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Pilot Eye Fixations: What Have We Learned About Monitoring?

There is a substantial literature on eye-tracking measurement for pilots. These measures offer one method for studying pilot visual attention. This presentation reviews this literature to identify the range of eye-tracking measures used; the primary findings from eye tracking as it relates to commercial transport pilots; and whether we can learn anything from these studies about pilot monitoring. We identify gaps between the process of pilot monitoring and what we can know from studying eye tracking. This is a brief presentation.

Commercial Aviation↗

SU-E-J-196: New Visualization Methods for Longitudinal MRI Registrations and Segmentations

Purpose: To develop visualization techniques to facilitate easy assessment of (a) registration and (b) tracking volumetric changes in structures during radiation therapy from MRI. Method: The frequently used method for visualizing registrations between scans is a multi-color overlay technique or deformation vector fields. However, the overlay technique is unintuitive and does not help to appreciate the quality of registration particularly when the registration mismatches are not very large. Similarly, the deformation fields give an indication of extent of deformation but do not help to assess the differences in registration. We present a mirroring and edge-augmented mirroring technique that places the fixed and moving image next to each other and allows the user to quickly assess the small differences in registration. Next, we present a volumetric intersection based 3D model to visualize the changes in diseased lymph node volumes in head and neck cancer. 3D model-based visualization provides more information about the location-specific changes in volume rather than the simplistic one dimensional information obtained from 2D plot of nodal volume changes. Result: We show results comparing our approach with the standard colorbased overlay method for comparing registrations of intra-patient registrations using T2-MRI. Upon comparing the mirroring technique with the color-overlay, one can more easily appreciate the differences in registration. Adding edge-based mirroring seems to further assist in evaluating the registration. Our approach for viewing registrations seems to be more intuitive and easy to use in order to help assess the quality of registration compared to color-based overlays. Similarly, the change volumetric model together with a 2D plot reveals more information including the locations undergoing changes and responding to treatment. Conclusions: Better approaches are necessary for assessing the quality of registrations and changes in diseased structures over time. Our approach presents some novel visualization solutions for registration and segmentation.

60 APPLIED LIFE SCIENCES↗

A new method for tracking organ motion on diagnostic ultrasound images

Purpose: Respiratory-gated irradiation is effective in reducing the margins of a target in the case of abdominal organs, such as the liver, that change their position as a result of respiratory motion. However, existing technologies are incapable of directly measuring organ motion in real-time during radiation beam delivery. Hence, the authors proposed a novel quantitative organ motion tracking method involving the use of diagnostic ultrasound images; it is noninvasive and does not entail radiation exposure. In the present study, the authors have prospectively evaluated this proposed method. Methods: The method involved real-time processing of clinical ultrasound imaging data rather than organ monitoring; it comprised a three-dimensional ultrasound device, a respiratory sensing system, and two PCs for data storage and analysis. The study was designed to evaluate the effectiveness of the proposed method by tracking the gallbladder in one subject and a liver vein in another subject. To track a moving target organ, the method involved the control of a region of interest (ROI) that delineated the target. A tracking algorithm was used to control the ROI, and a large number of feature points and an error correction algorithm were used to achieve long-term tracking of the target. Tracking accuracy was assessed in terms of how well the ROI matched the center of the target. Results: The effectiveness of using a large number of feature points and the error correction algorithm in the proposed method was verified by comparing it with two simple tracking methods. The ROI could capture the center of the target for about 5 min in a cross-sectional image with changing position. Indeed, using the proposed method, it was possible to accurately track a target with a center deviation of 1.54 ± 0.9 mm. The computing time for one frame image using our proposed method was 8 ms. It is expected that it would be possible to track any soft-tissue organ or tumor with large deformations and changing cross-sectional position using this method. Conclusions: The proposed method achieved real-time processing and continuous tracking of the target organ for about 5 min. It is expected that our method will enable more accurate radiation treatment than is the case using indirect observational methods, such as the respiratory sensor method, because of direct visualization of the tumor. Results show that this tracking system facilitates safe treatment in clinical practice.

60 APPLIED LIFE SCIENCES↗

Oculometric Analysis of Saccadic Compensation for Visual Motion Processing Impairment due to Alcohol and Sleep Disruption

The Visuomotor Control Laboratory at Ames Research Center has developed a 5-minute ocular tracking test that computes 21 largely independent metrics of visuomotor performance, reflecting neural signal processing along a number of distinct pathways through cortex, brainstem, and cerebellum. Human sensorimotor performance is resilient to the challenges and stressors of many operational environments, in part, because overall performance is achieved through multiple parallel systems. Our multidimensional oculometrics allow us to examine impacts on these sub-components separately. To illustrate this, we contrasted the effects of two mild neural stressors, acute sleep-deprivation and low-dose alcohol. We have previously shown that, in both cases, oculometric analysis is a highly sensitive indicator of impairment. Here we quantified not only the observed impact on the performance of one sub-system, smooth pursuit, which uses high-level cortical processing of visual motion to track a moving object, but also the observed (partial) compensation by an evolutionarily older mid-brain and brainstem subsystem, saccades, which generates jumps in eye position to catch up with the target when smooth pursuit is inadequate. Specifically, we examined the dose-response (effect size vs. dose size) of the ground lost (pursuit deficit) and the ground recouped (saccadic compensation) across three separate studies – acute low-dose alcohol administration (16 subjects), acute sleep loss (12 subjects), and acute sleep loss with caffeine intervention (9 subjects). We computed the dose-response slopes using linear regression. The figure below shows that, in the case of acute sleep deprivation, the resulting slopes for ground lost and ground recouped (mean ± SE across subjects) were significantly different (paired t-test, t(11) = 5.17, p < 0.001), indicating poor saccadic compensation. However, when sleep loss was coupled with caffeine ingestion, ground lost was decreased and ground recouped increased such that the slopes were no longer different (t(8) = -0.05, p = 0.965). With alcohol, the two slopes were large albeit not significantly different (t(15) = 0.96, p = 0.351), indicating significant pursuit impairment but effective saccadic compensation. Our findings show that sleep deprivation and alcohol affect oculomotor performance differently. Low-dose alcohol effects appear predominantly cortical, with effective brainstem compensation. Sleep loss and circadian disruption however appears to affect both cortical and brainstem pathways with caffeine providing an effective countermeasure to both effects. Beyond the mere detection of impairment, our oculometric assessment allows us to characterize the nature of the deficit, to provide insight into the neural substrate, and to assess the effectiveness of countermeasures.

pursuit↗

The virtual wind tunnel

Consideration is given to the design and implementaion of a virtual environment linked to a graphics workstation for the visualization of complex fluid flows. The user wears a stereo head-tracked display which displays 3D information and an instrumented glove to intuitively position flow-visualization tools. The idea is to create for the user an illusion that he or she is actually in the flow manipulating visualization tools. The user's presence does not disturb the flow so that sensitive flow areas can be easily investigated. The flow is precomputed and can be investigated at any length scale and with control over time. Particular attention is given to the visualization structures and their interfaces in the virtual environment, hardware and software, and the performance of the virtual wind tunnel using flow past a tapered cylinder as an example.

Bryson, Steve↗

Comprehension of Spacecraft Telemetry Using Hierarchical Specifications of Behavior

A key challenge in operating remote spacecraft is that ground operators must rely on the limited visibility available through spacecraft telemetry in order to assess spacecraft health and operational status. We describe a tool for processing spacecraft telemetry that allows ground operators to impose structure on received telemetry in order to achieve a better comprehension of system state. A key element of our approach is the design of a domain-specific language that allows operators to express models of expected system behavior using partial specifications. The language allows behavior specifications with data fields, similar to other recent runtime verification systems. What is notable about our approach is the ability to develop hierarchical specifications of behavior. The language is implemented as an internal DSL in the Scala programming language that synthesizes rules from patterns of specification behavior. The rules are automatically applied to received telemetry and the inferred behaviors are available to ground operators using a visualization interface that makes it easier to understand and track spacecraft state. We describe initial results from applying our tool to telemetry received from the Curiosity rover currently roving the surface of Mars, where the visualizations are being used to trend subsystem behaviors, in order to identify potential problems before they happen. However, the technology is completely general and can be applied to any system that generates telemetry such as event logs.

Runtime monitoring↗

Monte Carlo simulation of astronaut light flash observations on Apollo and Skylab missions

Monte Carlo calculations are performed to study the relation between cosmic ray nuclei and visual flashes observed by astronauts, in space. A satisfactory overall fit to all available data excluding the Skylab observations in the South Atlantic Anomaly (SAA) has been achieved by varying three visual system parameters: effective retinal thickness, minimum projected track length inside retina and minimum energy loss rate. All light flash data from space excluding the SAA observations can be understood fully upon the basis of the primary cosmic ray charge and energy spectra together with the fitted values of the three visual system parameters. Monte Carlo simulations of the SAA observations suggest the existence of a previously unobserved multiply-charged component of the inner radiation belt.

Osborne, W. Z.↗

AMPP-4 Tank Tracking Tools

The Material Recovery & Recycle group (AMPP-4) Tank Tracking Tools are Microsoft Excel-based tools used to visualize the liquid levels in the tanks used by teams within AMPP-4. The tools rely on reports generated by the Tracking Hydrogen Accumulation in Aqueous Operations spreadsheet to provide daily data of the volume occupied by radioactive liquid waste (RLW). This set-up allows for rapid-response in viewing historical (from October 2024) and current data in thermometer-type charts.

97 MATHEMATICS AND COMPUTING↗

Visual/motion cue mismatch during a coordinated roll maneuver

The effect of a performance mismatch between the simulator visual and motion display systems on pilot performance while engaged in a compensatory tracking task, and the effect of a reduction in simulator motion scaling while maintaining constant visual scaling on pilot performance for this same task were investigated. A jet transport aircraft with motion in the roll and lateral simulator axes was used as a test vehicle for a computer simulation. The aircraft was disturbed by moderate levels of turbulence which resulted in flight path deviations in the roll and lateral axes. The task of the pilot was to maintain flight formation behind the aircraft in front of him as displayed by a video monitor located in the simulator cockpit. Experimental data consisting of pilot describing functions and pilot performance scores are presented and discussed as they relate to experimental evidence.

Shirachi, D. K.↗

Use of the tilt cue in a simulated heading tracking task

The task was performed with subjects using visual-only cues and combined visual and roll-axis motion cues. Half of the experimental trials were conducted with the simulator rotating about the horizontal axis; to suppress the tilt cue, the remaining trials were conducted with the simulator cab tilted 90 deg so that roll-axis motions were about earth vertical. The presence of the tilt cue allowed a substantial and statistically significant reduction in performance scores. When the tilt cue was suppressed, the availability of motion cues did not result in significant performance improvement. These effects were accounted for by the optimal-control pilot/vehicle model, wherein the presence or absence of various motion cues was represented by appropriate definition of the perceptual quantities assumed to be used by the human operator.

Levison, W. H.↗

Automated scanning of plastic nuclear track detectors using the Minnesota star scanner

The problems found in an attempt to adapt an automated scanner of astronomical plates, the Minnesota Automated Dual Plate Scanner (APS), to locating and measuring the etch pits produced by ionizing particles in plastic nuclear track detectors (CR-39) are described. A visual study of these pits was made to determine the errors introduced in determining positions and shapes. Measurements made under a low power microscope were compared with those from the APS.

Fink, P. J.↗

The visual control of simulated altitude

The ability of a subject flying an experimental flight to use the different sources of visual information by looking at the vertical tracking error was investigated using a 3 (altitude) x 3 (texture) x 2 (replication) factorial design. Each subject flew these 18 flights in the same partially counterbalanced order, constructed such that there was one flight at each of the three altitudes, and over each of the three surface textures within each successive set of three flights. The three ground-surface textures used consisted of meridian, latitudinal, and square textures described by Wolpert et al. (1983). The results showed that, in displays where only splay information was available, the subjects tended to confuse lateral motion with vertical.

Johnson, Walter W.↗

Interactive data exploration and particle tracking for general circulation models

The SCENE environment for interactive visualization of complex data sets is discussed. This environment is used to create tools for graphical exploration of atmospheric flow models. These tools may be extended by the user in a seamless manner, so that no programming is required. A module for accurately tracing field lines and particle trajectories in SCENE is presented. This is used to examine the flowfield qualitatively with streamlines and pathlines and to identify critical points in the velocity field. The paper also describes a visualization tool for general circulation models on which the primary features of the environment are demonstrated.

Rosenbaum, R. I.↗

Motor scaling by viewing distance of early visual motion signals during smooth pursuit

The geometry of gaze stabilization during head translation requires eye movements to scale proportionally to the inverse of target distance. Such a scaling has indeed been demonstrated to exist for the translational vestibuloocular reflex (TVOR), as well as optic flow-selective translational visuomotor reflexes (e.g., ocular following, OFR). The similarities in this scaling by a neural estimate of target distance for both the TVOR and the OFR have been interpreted to suggest that the two reflexes share common premotor processing. Because the neural substrates of OFR are partly shared by those for the generation of pursuit eye movements, we wanted to know if the site of gain modulation for TVOR and OFR is also part of a major pathway for pursuit. Thus, in the present studies, we investigated in rhesus monkeys whether initial eye velocity and acceleration during the open-loop portion of step ramp pursuit scales with target distance. Specifically, with visual motion identical on the retina during tracking at different distances (12, 24, and 60 cm), we compared the first 80 ms of horizontal pursuit. We report that initial eye velocity and acceleration exhibits either no or a very small dependence on vergence angle that is at least an order of magnitude less than the corresponding dependence of the TVOR and OFR. The results suggest that the neural substrates for motor scaling by target distance remain largely distinct from the main pathway for pursuit.

Non-NASA Center↗

Measurement and Analysis of Atmospheric Spectral Optical Depths with NASA Ames Airborne Sunphotometers During TARFOX and ACE-2

In accordance with the scope of work of this contract, the following tasks were undertaken and completed during the course of the contract: (1) Participation in the design and development of the 14-channel Ames Airborne Tracking Sunphotometer (AATS-14), including the development and implementation of Visual Basic software for real-time data processing and display and post-acquisition data reduction and analysis. (2) Operation of the six-channel Ames Airborne Tracking Sunphotometer (AATS-6) aboard the University of Washington C-131A during TARFOX and in-field analysis and presentation of data acquired with the AATS-6. (3) Post-mission analysis of data acquired during TARFOX with the AATS-6 and the AATS-14. (4) Pre-TARFOX calibration of the AATS-6 at Mauna Loa Observatory in May 1996, and post-TARFOX calibration of the AATS-6 and AATS- 14 at Zugspitze, Germany in October 1996, including analyses of all data sets. (5) Analysis of AATS-14 airborne calibration data acquired on 17 November 1996 during a late afternoon Pelican flight over the central California coast. (6) Operational training, instrument preparation, field coordination, and analysis of shipboard measurements of aerosol optical depth with the AATS-6 during ACE-2. (7) Coordination of data acquisition with the AATS-14 aboard the Pelican during ACE-2 and in-field preliminary data analysis and presentation. (8) Calibration of the AATS-6 and AATS-14 in April/May 1997 at Mauna Loa prior to ACE-2, and post-mission calibration of the AATS-6 at Mauna Loa in August 1997.

Livingston, John M.↗