Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage balancing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Single Event Transient Response of Vertical and Lateral Waveguide-Integrated Germanium Photodiodes

Pulsed-laser induced single event current measurements on two geometries of waveguide-integrated germanium photodiodes were conducted over a range of operating voltages to examine the impact of photodiode geometry on the transient response. Vertical PIN photodiodes exhibit transients with a duration that is relatively independent of the operating voltage while the transient duration in lateral PIN photodiodes depends on operating voltage. Furthermore, the experimental measurements facilitate identification of device dimensions that impact the transient response. In this work, these results can be used to identify potential radiation mitigation strategies for photodiodes operating in a radiation environment. Understanding the implications of design choices is critical for designing integrated photonic systems that balance system performance with tolerance for radiation degradation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion-specific phenomena limit energy recovery in forward-biased bipolar membranes

The ability for bipolar membranes (BPMs) to interconvert voltage and pH makes them attractive materials for use in energy conversion and storage. Reverse-biased BPMs, which use electrical voltage to dissociate water into acid and base, have become increasingly well studied. However, forward-biased BPMs (FB-BPMs), in which voltage is extracted from pH gradients through recombination, require further study. Here physics-based modeling elucidates how the complex coupling of transport and kinetics dictates the performance of FB-BPMs in electrochemical devices. Simulations reveal that the open-circuit potential of FB-BPMs is dictated by the balance of ion recombination and crossover, where recombination of buffering counter-ions attenuates the open-circuit potential. Counter-ion mass-transport limitations and uptake of ionic impurities limit achievable current densities by reducing the applied pH gradient or the available fixed-charge sites that mediate recombination. Further, the model highlights the importance of selective ion management in mitigating energy losses and provides insight into the rational material design of FB-BPMs for energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Development and Testing of a Self-Injecting Gallium MPD Thruster

Discharge current and terminal voltage measurements were performed on a gallium electromagnetic thruster at discharge currents in the range of 20-54 kA. It was found that the arc impedance has a value of 6-7 m(Omega) at peak current. The absence of high-frequency oscillations in the terminal voltage trace indicates lack of the "onset" condition often seen in MPD arcs, suggesting that a sufficient number of charge carriers are present for current conduction. The mass ablated per pulse was not measured experimentally; however the mass flow rate was calculated using an ion current assumption and an anode power balance. Measurement of arc impedance predicts a temperature of 3.5 eV which from Saha equilibrium corresponds to Z = 2.0 - 3.5, and assuming Z = 2 yields an Isp of 3000 s and thrust efficiency of 50%.

Thomas, Robert E.↗

Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer

This device is a biasable, submillimeter-wave, balanced mixer fabricated using JPL s monolithic membrane process a simplified version of planar membrane technology. The primary target application is instrumentation used for analysis of atmospheric constituents, pressure, temperature, winds, and other physical and chemical properties of the atmospheres of planets and comets. Other applications include high-sensitivity gas detection and analysis. This innovation uses a balanced configuration of two diodes allowing the radio frequency (RF) signal and local oscillator (LO) inputs to be separated. This removes the need for external diplexers that are inherently narrowband, bulky, and require mechanical tuning to change frequency. Additionally, this mixer uses DC bias-ability to improve its performance and versatility. In order to solve problems relating to circuit size, the GaAs membrane process was created. As much of the circuitry as possible is fabricated on-chip, making the circuit monolithic. The remainder of the circuitry is precision-machined into a waveguide block that holds the GaAs circuit. The most critical alignments are performed using micron-scale semiconductor technology, enabling wide bandwidth and high operating frequencies. The balanced mixer gets superior performance with less than 2 mW of LO power. This can be provided by a simple two-stage multiplier chain following an amplifier at around 90 GHz. Further, the diodes are arranged so that they can be biased. Biasing pushes the diodes closer to their switching voltage, so that less LO power is required to switch the diodes on and off. In the photo, the diodes are at the right end of the circuit. The LO comes from the waveguide at the right into a reduced-height section containing the diodes. Because the diodes are in series to the LO signal, they are both turned on and off simultaneously once per LO cycle. Conversely, the RF signal is picked up from the RF waveguide by the probe at the left, and flows rightward to the diodes. Because the RF is in a quasi- TEM (suspended, microstrip-like) mode, it impinges on the diodes in an anti-parallel mode that does not couple to the waveguide mode. This isolates the LO and RF signals. This operation is similar to a cross-bar mixer used at low frequencies, except the RF signal enters through the back-short end of the waveguide rather than through the side. The RF probe also conveys the down-converted intermediate frequency (IF) signal out to an off-chip circuit board through a simple LC low-pass filter to the left as indicated. The bias is brought to the diodes through a bypass capacitor at the top.

Siegel, Peter↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Innovative Symmetrical Electrolyte Architecture Enables Ultra-Flat and Thermal Resilient Protonic Ceramic Electrochemical Cells

Protonic ceramic electrochemical cells (PCECs) represent a promising class of solid‐state energy conversion devices capable of high‐efficiency hydrogen production and power generation. However, the practical deployment of planar PCECs is fundamentally constrained by severe structural deformation and mechanical failure during fabrication, stemming from asymmetric shrinkage between the thin electrolyte and the thick NiO‐based support layer. Here, in this work, a functionally integrated, symmetry‐engineered double‐sided electrolyte (DE) design is unveiled, which not only suppresses thermally induced curvature but also unlocks significant gains in electrochemical performance and stability. This architecture intrinsically balances shrinkage dynamics across the cell bilaterally, enabling the fabrication of ultra‐flat 5 × 5 cm 2 cells with sub‐100 µm thickness variation. A numerical solid mechanics simulation is introduced to investigate and interpret this achievement. Beyond structural advantages, the DE configuration enhances the cell operational stability, delivering a low open‐circuit voltage degradation of 9.5 mV/100 h across 80 thermal cycles. This work establishes a compelling paradigm wherein architectural symmetry directly translates to both mechanical fidelity and functional enhancement, offering a promising route toward PCECs scale‐up.

08 - HYDROGEN↗

Hardware-in-the-Loop Evaluation of Grid-Edge DER Chip Integration Into Next-Generation Smart Meters

To facilitate the implementation of distributed energy resource management systems (DERMS), we propose to insert a grid-edge distributed energy resource (DER) chip hosting a DERMS algorithm into the next generation of smart meters. This will create a pathway for the wide adoption of DERMS technology because many utilities plan to invest in advanced metering infrastructure in the near future. This will also bridge the gap between an electrical power utility and DERs behind the meter. The DER chip is designed to follow power direction signals from the DERMS coordinator while balancing its local objectives. We tested the chip using a controller- and power-hardware-in-the-loop evaluation under three scenarios that a DERMS could face in the real world. The DER chip was capable of and effective at directing four heterogeneous DERs to respond to a DERMS coordinator for grid services (e.g., voltage regulation and a virtual power plant).

distributed energy resource management system↗

Hardware-in-the-Loop Evaluation of Grid-Edge DER Chip Integration Into Next-Generation Smart Meters: Preprint

To facilitate the implementation of distributed energy resource management systems (DERMS), we propose to insert a grid-edge distributed energy resource (DER) chip hosting a DERMS algorithm into the next generation of smart meters. This will create a pathway for the wide adoption of DERMS technology because many utilities plan to invest in advanced metering infrastructure in the near future. This will also bridge the gap between an electrical power utility and DERs behind the meter. The DER chip is designed to follow power direction signals from the DERMS coordinator while balancing its local objectives. We tested the chip using a controller- and power-hardware-in-the-loop evaluation under three scenarios that a DERMS could face in the real world. The DER chip was capable of and effective at directing four heterogeneous DERs to respond to a DERMS coordinator for grid services (e.g., voltage regulation and a virtual power plant).

distributed energy resource management system↗

Reinforced AEM Separators Based on Triblock Copolymers for Electrode-decoupled RFBs

Washington University in St. Louis (WUSTL), in collaboration with The University of Texas at San Antonio (UTSA) and Giner Inc. developed highly selective anion exchange membranes (AEMs) and a novel electrode-decoupled redox flow battery (RFB) for grid scale energy storage as part of the ARPA-E IONICS program (with connections to the DAYS program in the later part of the project). RFBs exhibit the crucial characteristic of system-level decoupled scaling of energy and power which makes them cost effective for the multi-GWh scales envisioned for grid-scale energy storage solutions. This has led to extensive (and deserved) research interest and attention. This project aimed to enhance the design space available for redox-flow batteries (RFBs) by enabling the long-term separation of disparate cationic (elemental) actives using a highly selective membrane separator, while concurrently permitting the transport of anions to balance charge. The approach proposed was to design and develop a highly selective anion-exchange membrane (AEM), which would in turn permit the design and development of electrode-decoupled RFBs. Pairs of (different element) cationic species with redox reactions exhibiting a large difference in their standard electrode potentials were identified to develop high voltage, high power RFBs while disrupting the existing paradigm of using a single element which can ionize to more than two soluble oxidation states (e.g.: Vanadium).

25 ENERGY STORAGE↗

TOPEX electrical power system

The TOPEX mission requirements which impact the power requirements and analyses are presented. A description of the electrical power system (EPS), including energy management and battery charging methods that were conceived and developed to meet the identified satellite requirements, is included. Analysis of the TOPEX EPS confirms that all of its electrical performance and reliability requirements have been met. The TOPEX EPS employs the flight-proven modular power system (MPS) which is part of the Multimission Modular Spacecraft and provides high reliability, abbreviated development effort and schedule, and low cost. An energy balance equation, unique to TOPEX, has been derived to confirm that the batteries will be completely recharged following each eclipse, under worst-case conditions. TOPEX uses three NASA Standard 50AH Ni-Cd batteries, each with 22 cells in series. The MPS contains battery charge control and protection based on measurements of battery currents, voltages, temperatures, and computed depth-of-discharge. In case of impending battery depletion, the MPS automatically implements load shedding.

Chetty, P. R. K.↗

High-voltage water-scarce hydrogel electrolytes enable mechanically safe stretchable Li-ion batteries

Soft Li-ion batteries, based on conventional organic electrolytes, face performance degradation challenges due to moisture penetration and safety concerns due to possible leakage of toxic fluorine compounds and flammable solvents under mechanical damage. We design a water-scarce hydrogel electrolyte with fluorine-free lithium salt to achieve wide electrochemical stability window (up to 3.11 volts) in ambient air without hermetic packaging while balancing high stretchability (1348%), ion conductivity (41 millisiemens per centimeter), and self-healing capabilities for mechanically and chemically safe stretchable Li-ion batteries. Molecular synergy between hydrophilicity and lithiophilicity of zwitterionic polymer backbone is revealed by molecular dynamics simulations. The battery exhibits capacity retention under harsh mechanical stresses—enduring stretching, twisting, folding, and multiple through-punctures by a needle—while self-healing from repeated through cuts by a razor blade. Stable ambient operation for 1 month over 500 charge-discharge cycles (average coulomb efficiency, 95%) is achieved. A prototype self-healing electronic system with embedded soft batteries demonstrates practical application as a durable embodied energy source.

Science & Technology - Other Topics↗

ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Validation of prediction capability of operating space for plasma initiation in MAST-U

DYON is a plasma initiation modelling code that solves the differential equation system of the full circuit equations (plasma current, active coil currents and eddy currents in full passive structures) and 0D global energy and particle balance equations (Kim 2022 Nucl. Fusion 62 126012). In order to test the capability of the full electromagnetic plasma initiation model to predict individual discharges in experiments and thus the operating space in the device, a dedicated experimental database was built in MAST-U by scanning the prefilled gas pressure p 0 and the induced loop voltage V loop . In the experimental operating space of p 0 and V loop the lower and the upper limits of p 0 are determined by the plasma breakdown failure and the plasma burn-through failure, respectively. The lower limit of V loop is determined by the plasma burn-through failure. By directly reading the control room data used in each discharge (i.e. currents in the solenoid, poloidal field coils, and toroidal field coils, p 0 , and gas puffing rate), the full electromagnetic DYON consistently predicted the failed breakdown, failed burn-through, and successful plasma initiation discharges in the experimental database, demonstrating its capability to predict the operating space for inductive plasma initiation. The Paschen curve calculated with the effective connection length in MAST-U indicates a much higher p 0 required for plasma breakdown than the experimental data, indicating that individual field line evaluation is necessary to calculate the quantitative requirements for Townsend breakdown. The demonstration in this paper shows that the full electromagnetic DYON could be a useful simulation tool to assess the feasibility of inductive plasma initiation and to optimise operating scenarios in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling Grid-Forming Control Under Unbalanced Conditions

Standalone microgrids often experience unbalanced loading and faults, which can cause grid-forming control designed for balanced conditions to produce oscillatory responses. To address this issue, a compact time-domain transformation appropriate for inverter control is proposed, allowing the conversion of unbalanced three-phase signals to positive and negative synchronous reference frames. This transformation supports the development of a grid-forming control with fault ride-through, featuring frequency and voltage droop controllers and nested current and voltage control loops that seamlessly integrate an enhanced current limiter. The effectiveness of the proposed control and transformation is demonstrated through analytical results and electromagnetic transient simulation.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Electrochemical Reactions Under Reverse Bias Create Additional Mobile Ions That Enable Hole Tunneling in Metal Halide Perovskite Diodes

Gradual reverse-bias breakdown in metal-halide perovskite diodes and solar cells is thought to originate from hole tunneling through steep bands in an ionic depletion region near the electron-transport layer after positively charged iodine vacancies accumulate near the hole-transport layer (HTL). However, typical reported mobile-ion concentrations near 1 x 10^17 cm-3 are too small to quantitatively explain significant tunneling-current densities and (Zener) breakdown observed near -5 V. Here, we show that inferred mobile-ion concentrations increase by more than 100x, to over 1 x 10^18cm-3 , within just 3 min of reverse bias at -6.0 V in p-i-n perovskite diodes. We attribute this increase to iodide oxidation and coupled iodine vacancy creation that must be balanced by reduction reactions near the HTL. Sub-optimal HTL coverage leads to direct contact between the transparent conducting electrode and perovskite, facilitates reduction events, enables the creation of even larger inferred mobile-ion concentrations (~1 x 10^19cm-3 ), and leads to faster degradation under reverse bias. This explains previous work that showed increased breakdown voltages and improved reverse-bias stability by implementing thick, uniform HTLs.

14 SOLAR ENERGY↗

Thermoradiative Conversion for Space Power Systems

The thermoradiative cell is a new method for converting heat energy to electrical power, first detailed by Strandberg in 2015. The cell is structurally similar to a photovoltaic cell, in that it is a p-n junction semiconductor device, but thermodynamically operates in the reverse direction, converting the thermal dark current into electrical power by utilizing the recombination radiation from thermally-generated electron hole pairs to radiate waste heat to space. This technology may have application for space missions in converting thermal energy produced by a radioisotope source or from a nuclear reactor into power. The power and efficiency can be calculated as a function of bandgap in the detailed-balance case (the Shockley-Queisser limit), in which all of the thermal emissivity of the cell is due to the recombination of thermally generated electron-hole pairs, and all other recombination losses are ignored. The current produced is directly proportional to the recombination radiation, and thus the more thermally generated pairs, the higher the current. The voltage is proportional to the external bias. These two constraints allow optimization of the optimum bias point for maximum power, and allow calculation of the efficiency at maximum power point. Unlike photovoltaic cells, the maximum power operating point is not the same as the maximum efficiency point, and higher efficiency can be achieved at a higher (negative) bias in the ideal case. Incorporating non-ideal losses, however, shifts the maximum efficiency point toward lower bias. Since a thermoradiative cell operates by radiating directly to space, the current produced by a themoradiative cells will increase with the Stefan-Boltzman radiative efficiency; roughly the fourth power of the temperature. Thus, in contrast to a photovoltaic converter, the power produced is highest at high operating temperatures. Likewise, in contrast to conventional thermal conversion, high radiator temperature increases, rather than decreases the efficiency. Thus, the thermoradiative conversion may fill a mission niche in which small radiator size is required. The basic operation will be summarized, applications to space power discussed, and the requirements for further research outlined.

Photovoltaic Cell↗

2 kV, 0.7 mΩ•cm2 Vertical Ga2O3 Superjunction Schottky Rectifier with Dynamic Robustness

We report the first experimental demonstration of a vertical superjunction device in ultra-wide bandgap (UWBG) Ga 2 O 3 . The device features 1.8 μm wide, 2×10 17 cm -3 doped n-Ga 2 O 3 pillars wrapped by the charge-balanced p-type nickel oxide (NiO). The sidewall NiO is sputtered through a novel self-align process. Benefited from the high doping in Ga 2 O 3 , the superjunction Schottky barrier diode (SJ-SBD) achieves a ultra-low specific on-resistance (R ON,SP ) of 0.7 mΩ•cm 2 with a low turn-on voltage of 1 V and high breakdown voltage (BV) of 2000 V. The R ON,SP ~BV trade-off is among the best in all WBG and UWBG power SBDs. The device also shows good thermal stability with BV > 1.8 kV at 175 °C. In the unclamped inductive switching tests, the device shows a dynamic BV of 2.2 kV and no degradation under 1.7 kV repetitive switching, verifying the fast acceptor depletion in NiO under dynamic switching. Such high-temperature and switching robustness are reported for the first time in a heterogeneous superjunction. These results show the great potential of UWBG superjunction power devices.

Qin, Yuan↗