Search NASA⌕ Search

SEARCH · Search NASA

Results for “voltage estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 307 records · Page 17

Spacecraft charging in the auroral plasma: Progress toward understanding the physical effects involved

The work is presented in four parts. First, main differences between the plasma environments in geostationary orbit and low polar orbit with regard to high-voltage charging situations are reviewed. Next, results are presented from a calculation of secondary-electron escape currents from negatively-charged spacecraft surfaces having various orientations relative to the local magnetic-field direction. It is shown that for finite ranges of combinations of electric and magnetic field directions, secondary-electron escape is completely suppressed and therefore cannot help to discharge the spacecraft. In such circumstances, secondary electrons may travel distances many times their gyroradii before reimpacting, and this may produce greatly increased secondary-electron surface currents. Thirdly, a simple rough estimate of the required conditions for high-voltage auroral-zone charging is developed. The results suggest that for any given spacecraft, surface potentials are likely to depend more strongly on the ratio of ambient flux of high-energy electrons to that of all ions, than on any other environmental parameter. Finally, preliminary results are presented of numerical simulation work directed toward testing this hypothesis. Numerical instabilities encountered in doing this simulation work probably are closely related to physical sensitivities inherent in the physics of the ion wake behind the spacecraft, and especially to beam-like constituents of the ion population in the wake.

Laframboise, J. G.↗

Tools for Enhanced Grid Operation and Optimized PV Penetration Utilizing Highly Distributed Sensor Data.

Increasing number s of PV on distribution systems are creating more grid impacts , but it also provides more opportunities for measurement, sensing, and control of the grid in a distributed fashion. This report demonstrates three software tools for characterizing and controlling distribution feeders by utilizing large numbers of highly distributed current, voltage , and irradiance sensors. Instructions and a user manual is presented for each tool. First, the tool for distribution system secondary circuit parameter estimation is presented. This tool allows studying distribution system parameter estimation accuracy with user-selected active power, reactive power, and voltage measurements and measurement error levels. Second, the tool for multi-objective inverter control is shown. Various PV inverter control strategies can be selected to objectively compare their impact on the feeder. Third, the tool for energy storage for PV ramp rate smoothing is presented. The tool allows the user to select different storage characteristics (power and energy ratings) and control types (local vs. centralized) to study the tradeoffs between state-of-charge (SOC) management and the amount of ramp rate smoothing.

Reno, Matthew J.↗

Quantitative Electroluminescence Imaging Analysis for Performance Estimation of PID-Influenced PV Modules

An empirical method for estimating relative power losses caused by potential-induced degradation (PID) for p-type solar cells and modules using quantitative electroluminescence (EL) analysis (QELA) is presented. First, EL images are corrected for camera- and perspective distortion. The relative power loss map is then calculated from the logarithmic ratio of two EL images, taken either before and after PID degradation or at different applied currents. Only the cell average of the resulting power loss map is evaluated. The highest power loss across each string is averaged to obtain the overall power loss. Consequently, for modules with three strings, three cells are averaged. The resulting power loss depends on the current applied. The conversion to equivalent irradiance allows for comparison of measured and estimated device performance. The analysis of roughly 2000 EL images and related current-voltage (I-V) curves indicates a good agreement between flash-test-measured and performance estimated using QELA. A relative root mean square error of 1-3% can be achieved.

14 SOLAR ENERGY↗

Voltage Stability Assessment Using Synchronized Phasor Measurements Applied to the Argentine Power System

This paper presents tests of different methods for long term voltage stability analysis based on PMU measurements. In particular, Thevenin Impedance Matching and sensitivity calculation are studied. Simulation are performed in a modified Argentine power system model, to include the main components for studying long term voltage stability. Disconnection of a large Thermal Generating Station causing long-term voltage instability at Gran Buenos Aires Area is studied. It is shown that computing the apparent impedance of Thevenin equivalent at load bus from measurements taken at a single time but at various locations of the transmission corridor produce a significant reduction of the estimation error produce when only local measurements are used. Voltage Stability analysis is performed using a reduced power system model where changing parameters are fully computed through PMU data at each time. Over this reduced power system model, voltage stability index and sensibility calculations are performed.

Gill-Estebez, Pablo↗

InGaAsSb Detectors' Characterization for 2-Micron CO2 Lidar/DIAL Applications

Recent interest in monitoring atmospheric CO2 focuses attention on infrared remote sensing using the 2-micron lidar/differential absorption lidar (DIAL) technique. Quantum detectors are critical components in this technique, and many research efforts concentrate on developing such devices for the 2-micron wavelength. Characterization results of InGaAsSb quantum detectors for the 2-micron wavelength range are presented, including experimental setup and procedure. Detectors are prototype devices manufactured by using separate absorption and multiplication (SAM) structures. Characterization experiments include V-I measurements, spectral response and its variation with bias voltage and temperature, noise measurements, noise-equivalent-power (NEP) and detectivity calculations, and signal-to-noise ratio (SNR) estimation. A slight increase in the output signal occurred with increased bias voltage and was associated with a noise level increase. Cooling down the detectors reduces noise and shifts the cutoff wavelength to shorter values. Further improvement in the design and manufacturing process, by increasing the device gain and lowering its noise level, is necessary to meet the required CO2 lidar/DIAL specifications.

Refaat, Tamer F.↗

InGaAsSb Detectors Characterization for 2-Micron CO2 Lidar/DIAL Applications

Recent interest in monitoring atmospheric CO2 focuses attention on infrared remote sensing using the 2-micron lidar/differential absorption lidar (DIAL) technique. Quantum detectors are critical components in this technique, and many research efforts concentrate on developing such devices for the 2-micron wavelength. Characterization results of InGaAsSb quantum detectors for the 2-micron wavelength range are presented, including experimental setup and procedure. Detectors are prototype devices manufactured by using separate absorption and multiplication (SAM) structures. Characterization experiments include V-I measurements, spectral response and its variation with bias voltage and temperature, noise measurements, noise-equivalent-power (NEP) and detectivity calculations, and signal-to-noise ratio (SNR) estimation. A slight increase in the output signal occurred with increased bias voltage and was associated with a noise level increase. Cooling down the detectors reduces noise and shifts the cutoff wavelength to shorter values. Further improvement in the design and manufacturing process, by increasing the device gain and lowering its noise level, is necessary to meet the required CO2 lidar/DIAL specifications.

Refaat, Tamer F.↗

Circuit transients due to negative bias arcs on a high-voltage solar array in low Earth orbit

Arcing to negatively biased, exposed solar cell interconnects on solar arrays placed in plasma environments was established. Arcing, however, may cause damaging interference with the operation of electrical power systems in spacecraft planned to be driven with high-voltage solar arrays. An analytical model was developed to estimate the effects of netagive bias arcs on solar array power system performance. Solar cell characteristics, plasma interactions, and power system features are modeled by a linear, lumped element transient circuit, and the time domain equations are solved. Numerical results for solar array common mode and load voltage transients are calculated for typical conditions. Acceptable load transients are found for a range of arc current amplitudes and time constants.

Metz, R. N.↗

State estimation for spacecraft power systems

A state estimator appropriate for spacecraft power systems is presented. Phasor voltage and current measurements are used to determine the system state. A weighted least squares algorithm with a multireference transmission cable model is used. Bad data are identified and resolved. Once the bad data have been identified, they are removed from the measurement set and the system state can be estimated from the remaining data. An observability analysis is performed on the remaining measurements to determine if the system state can be found from the reduced measurement set. An example of the algorithm for a sample spacecraft power system is presented.

Williamson, Susan H.↗

Distribution System State Estimation in the Presence of High Solar Penetration

In recent years, the low-to-medium voltage distribution networks are experiencing rising levels of distributed energy resources, including renewable generation, along with improved sensing, communication and automation infrastructure. As such, state estimation methods for distribution systems are becoming increasingly relevant as a means to enable better control strategies that can both leverage the benefits and mitigate the risks associated with high penetration of variable and uncertain distributed generation resources. Primary challenges of this problem include modeling complexities (nonlinear non-convex power-flow equations), limited availability of sensor measurements, and high penetration of uncertain renewable generation. This paper formulates the distribution system state estimation as a nonlinear weighted least squares problem, based on sensor measurements as well as forecasts data (both load and generation). We investigate the sensitivity of state estimator accuracy to (load/generation) forecast uncertainties, sensor accuracy, and sensor coverage levels.

Distribution system state estimation, nonlinear op↗

Grid Optimization with Solar (GO-Solar) Experiences With: Data-Driven and Machine Learning Approaches for High-Pen PV Grids

Provides an overview of the innovations and challenges from the algorithm development portion of the GO-Solar project, including plain language introductions to matrix-completion based state estimation, multi-kernel learning based state forecasting, 'slow-scale' voltage-load sensitivity matrix linearized optimal power flow, and 'fast-scale' OPF plan following using on-line Provides an overview of the innovations and challenges from the algorithm development portion of the GO-Solar project, including plain language introductions to matrix-completion based state estimation, multi-kernel learning based state forecasting, 'slow-scale' voltage-load sensitivity matrix linearized optimal power flow, and 'fast-scale' OPF plan following using on-line multi-objective state.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrospray Thruster Performance with Microfabricated Emitter Arrays and Indium Propellant

The feasibility of a microfabricated indium-fueled electrospray thruster with excellent performance was demonstrated. High efficiency electrospray thrusters with microfabricated components are under development for very compact, distributable propulsion systems that can be employed on both very small and large spacecraft with 10X improvement over SOA in mass, volume and specific impulse The critical components of this technology are the microfabricated emitter arrays and the capillary force driven indium feed system. Grey scale electron-beam lithography patterning and reactive ion dry etching provided the required micron-scale etch precision and uniformity across an array of 400 emitters in 1 cm2. Initial tests of single microfabricated silicon emitters demonstrated better performance than industry standard single emitters and the performance required to achieve 200 micronewtons when scaled up to a thruster with 400 emitters in 1 cm2. Arrays of emitters tested in a preliminary prototype Microfluidic Electrospray Propulsion (MEP) thruster assembly demonstrated stable performance at estimated thrust levels of 5, 50, and 120 µN at extraction voltages less than 4 kV. Current stability was within 0.15 % at 120 µN with only 1.5% of the emitter current collected by the extractor electrode. Post-test inspections revealed that more than 99% of the 400 emitters were electrospraying during the test. Specific impulse was estimated to be >3100 s from measurements of total charge and consumed indium mass at an emitter voltage of 1470 V. The results of this investigation suggest that microfabricated indium electrospray thruster technology is both feasible and capable of excellent performance as a highly compact microthruster.

Marrese-Reading, Colleen M.↗

Battery Capacity Fading Estimation Using a Force-Based Incremental Capacity Analysis

Traditionally health monitoring techniques in lithium-ion batteries rely on voltage and current measurements. A novel method of using a mechanical rather than electrical signal in the incremental capacity analysis (ICA) method is introduced in this paper. This method derives the incremental capacity curves based onmeasured force (ICF) instead of voltage (ICV). The force ismeasured on the surface of a cell under compression in a fixture that replicates a battery pack assembly and preloading. The analysis is performed on data collected from cycling encased prismatic Lithium-ion Nickel-Manganese-Cobalt Oxide (NMC) cells. For the NMC chemistry, the ICF method can complement or replace the ICV method for the following reasons. The identified ICV peaks are centered around 40% of state of charge (SOC) while the peaks of the ICF method are centered around 70% of SOC indicating that the ICF can be used more often because it is more likely that an electric vehicle (EV) or a plug-in hybrid electric vehicle (PHEV) will traverse the 70% SOC range than the 40% SOC. In addition the Signal to Noise ratio (SNR) of the force signal is four times larger than the voltage signal using laboratory grade sensors. The proposed ICF method is shown to achieve 0.42% accuracy in capacity estimation during a low C-rate constant current discharge. Future work will investigate the application of the capacity estimation technique under charging and operation under high C-rates by addressing the transient behavior of force so that an online methodology for capacity estimation is developed.

25 ENERGY STORAGE↗

Focal plane infrared readout circuit with automatic background suppression

A circuit for reading out a signal from an infrared detector includes a current-mode background-signal subtracting circuit having a current memory which can be enabled to sample and store a dark level signal from the infrared detector during a calibration phase. The signal stored by the current memory is subtracted from a signal received from the infrared detector during an imaging phase. The circuit also includes a buffered direct injection input circuit and a differential voltage readout section. By performing most of the background signal estimation and subtraction in a current mode, a low gain can be provided by the buffered direct injection input circuit to keep the gain of the background signal relatively small, while a higher gain is provided by the differential voltage readout circuit. An array of such readout circuits can be used in an imager having an array of infrared detectors. The readout circuits can provide a high effective handling capacity.

Pain, Bedabrata↗

Calculation of the Ionization Coefficient in the Townsend Discharge in the Mixture of Argon and Mercury Vapors with Temperature-Dependent Composition

For a hybrid model of the low-current discharge considering, along with direct ionization of the mixture components by electrons, the Penning ionization of mercury atoms by metastable argon atoms, the ionization coefficient in the argon–mercury mixture used in illuminating lamps is calculated. The analytical approximation formula describing the dependence of the ionization coefficient of the mixture on the reduced electric field strength and temperature is obtained for sufficiently wide ranges of their variations, and its accuracy is estimated. It is demonstrated that the discharge ignition voltage calculated using this formula is in agreement with the results of simulation and the available experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A systematic strategy for estimating hERG block potency and its implications in a new cardiac safety paradigm

Introduction: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. Methods: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. Results: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. Discussion: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.

60 APPLIED LIFE SCIENCES↗

Transfer-free graphene synthesis on sapphire by catalyst metal agglomeration technique and demonstration of top-gate field-effect transistors

Transfer-free graphene synthesis was performed on sapphire substrates by using the catalyst metal agglomeration technique, and the graphene film quality was compared to that synthesized on sputtered SiO{sub 2}/Si substrates. Raman scattering measurements indicated that the graphene film on sapphire has better structural qualities than that on sputtered SiO{sub 2}/Si substrates. The cross-sectional transmission microscopic study also revealed that the film flatness was drastically improved by using sapphire substrates instead of sputtered SiO{sub 2}/Si substrates. These quality improvements seemed to be due the chemical and thermal stabilities of sapphire. Top-gate field-effect transistors were fabricated using the graphene films on sapphire, and it was confirmed that their drain current can be modulated with applied gate voltages. The maximum field-effect mobilities were estimated to be 720 cm{sup 2}/V s for electrons and 880 cm{sup 2}/V s for holes, respectively.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗