Search NASA⌕ Search

SEARCH · Search NASA

Results for “AIR FLOW - COMPRESSIBILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Performance study of a novel dew point evaporative cooler in the climate of central Europe using building simulation tools

This paper presents the performance research of a hybrid air conditioning system (System II) equipped with novel dew point evaporative cooler (DPIEC) for a retail building located in temperate climatic conditions. The new cooler has a dedicated, adaptable structure that maximizes its performance in the climate conditions of central Europe. The unit can operate as a typical regenerative air cooler when outdoor air is drier than indoor air, it can operate as a counter-flow heat recovery unit when indoor conditions are more dry than outdoor and it can operate as a combination of both arrangements. The year-round, hourly-stepped building energy simulations were carried-out using a prognostic tool of energy consumption. The novel dew point evaporative cooler application potential was established using the black-box model based on regression equations was established based on experimental tests on a prototype of novel DPIEC. The hybrid system operation was compared to the typical air handling unit equipped with a standard energy wheel for heat recovery (System I). Presented research shows that DPIEC can cover about 95% of total cooling loads while the energy wheel covers only 9% of total cooling load. System II allows us to save 65% of seasonal electricity consumption comparing to System I. It comes from the fact that during most of the cooling season DPIEC is in operation and it covers most of the cooling loads without the need to switch the chilled water system.

Air conditioning↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Thermal chains and entrainment in cumulus updrafts, Part 1: Theoretical description

Recent studies have shown that cumulus updrafts often consist of a succession of discrete rising thermals with spherical vortex-like circulations. Herein, a theory is developed for why this “thermal chain” structure occurs. Theoretical expressions are obtained for a passive tracer, buoyancy, and vertical velocity in axisymmetric moist updrafts. Analysis of these expressions suggests that the thermal chain structure arises from enhanced lateral mixing associated with intrusions of dry environmental air below an updraft’s vertical velocity maximum. This dry air entrainment reduces buoyancy locally. Consequently, the updraft flow above levels of locally reduced buoyancy separates from below, leading to a breakdown of the updraft into successive discrete thermals. The range of conditions in which thermal chains exist is also analyzed from the theoretical expressions. A transition in updraft structure from isolated rising thermal, to thermal chain, to starting plume occurs with increases in updraft width, environmental relative humidity, and/or convective available potential energy. Corresponding expressions for the bulk fractional entrainment rate ε are also obtained. These expressions indicate rather complicated entrainment behavior of ascending updrafts, with local enhancement of ε up to a factor of ~2 associated with the aforementioned environmental air intrusions, consistent with recent large eddy simulation (LES) studies. These locally large entrainment rates contribute significantly to overall updraft dilution in thermal chain-like updrafts, while other regions within the updraft can remain relatively undilute. Part 2 of this study compares results from the theoretical expressions to idealized numerical simulations and LES.

54 ENVIRONMENTAL SCIENCES↗

Flow Development in Radial Plane of Rotating Detonation Engine Integrated with Aerospike

In this study, axial and radial velocity components are measured downstream of a rotating detonation engine (RDE) integrated with an aerospike by using particle image velocimetry (PIV) at 100 kHz. The RDE is operated at high pressures obtained by restricting the RDE exit with a converging nozzle, which also directs the flow radially toward the aerospike. Reactants, methane fuel, and enriched air (67% oxygen and 33% nitrogen) are supplied from separate plenums at ambient temperature. PIV data are presented to investigate how pressure ratios within the RDE channel affect the flow evolution across the aerospike. The RDE is shown to operate stably and consistently in a single wave mode for all six test runs. The study highlights large temporal and spatial variations in both axial and radial flow velocities at the nozzle throat that persist downstream across the aerospike. Each point in the flowfield oscillates at the frequency recorded inside the RDE channel. Overall, the temporally and spatially varying aerospike flowfield is far from the ideal case of a uniform flow at its exit, and it points toward the need to condition the flow within the RDE channel to produce more uniform conditions at the nozzle throat.

Engineering↗

Observations of airflow around a supertall curved building and its impact on temperature and humidity in Houston's urban center

Characterization of realistically shaped skyscrapers embedded in non-uniform neighbourhoods experiencing intricate weather patterns remains inadequately investigated. Aiming to close this gap, the Center for Multiscale Applied Sensing team deployed its mobile observatory in the street canyons around the curved Wells Fargo Plaza skyscraper in downtown Houston, TX. Three deployments allowed airflow observations under different inflow wind and thermodynamic stability conditions. Doppler lidar measurements reveal that when inflow hits the curved wall of the skyscraper, perpendicular canyons experience similar vortex configurations creating two windward and two leeward circulations. Windsond measurements support that buoyancy within the deep street canyons can generate thermal updrafts as strong as 2 m s -1 which is sufficient to overturn the mechanical downwash under gentle wind conditions. Canyons experiencing venting during the daytime were observed to be more thermodynamically stable at night while thermodynamically stable canyons during the day were observed to be more thermodynamically unstable at night owing to the accumulation of heat near street-level. Fourier decomposition of the vertical velocity measurements shows that in all cases flow exhibited high Reynolds numbers and was composed of turbulent eddies of predominantly 6 and 15 min periods. Here, this observational dataset provides insights to assess wind load, pedestrian comfort, urban air mobility, and natural ventilation and may be used as a benchmark for numerical model and wind tunnel studies attempting to represent realistically complex urban conditions.

54 ENVIRONMENTAL SCIENCES↗

Rapidly ramp cryogenic air separation unit without loss of O2 product purity—application for low-carbon fossil-fuel plants

The rapid integration of intermittent renewable sources into the electricity grid is driving the need for low-carbon, fossil-fuel power plant capable of rapid ramping. Therefore, a cryogenic air separation unit (ASU) as part of low-carbon, fossil-fuel power plant should be capable of rapid ramping. However, highly integrated and nonlinear processes of the ASU would significantly restrict this rapid ramping. To overcome this fundamental issue, we study the basic dynamic process of a state-of-the-art double-column ASU. A flow-driven dynamic model was established in Aspen Plus Dynamics, assuming perfect flow controls, to capture the basic dynamics of ramping ASU. We find the vapor-liquid counter-current flow structure in the low-pressure column is critical to the air separation when rapidly ramping the ASU. This flow structure is established based on a complicated heat integration process. It is simplified as an apparent counter-current heat transfer process in this work, which greatly reduces the complexity for studying the dynamics of ASU. For keeping this basic flow structure, the heat integration is maintained as its heat duty follows the ASU load, through several basic feed-forward and feed-back controllers on the critical stream flowrates. Moreover, we find a fundamental issue of mismatched dynamics in the low-pressure column, resulting in a significant loss of O2 product purity when rapidly ramping down the ASU and an obvious fluctuation of O2 product purity. Based on these explorations, we propose a basic control method for rapidly ramping the ASU without loss of O2 product purity. Results show the ASU basic dynamic process successfully ramps at a rate up to 10%/min (40-100% load) while maintaining the O2 product purity within 95.2-95.6 mol%.

Cheng, Mao↗

Adhesion-force micro-scale study of desiccating granular material

Experiments on five-, four-, three- and two-wet-hydrophilic-grain clusters were performed to investigate evolution of adhesion of granular media during drying on the micro-scale. The experiments show that the adhesion-force of a cluster initially grows at most to three times the original value before decreasing to zero by the end of evaporation. The adhesion-force is composed of capillary pressure force acting over the liquid/solid contact surface area, and surface tension forces acting over the three-phase contact perimeter length. This is in contrast with most macro-scale phenomenological models, in which the only desaturation process variables affecting strength are suction and saturation. Both the contact surface area and contact perimeter length are reduced to zero upon complete liquid evaporation. The morphology of an evaporating water body evolves through slow flow controlled by evaporation rate, interrupted by various modes of fast air entry, which are non-equilibrium jumps of liquid/gas interfaces (Haines jumps). The instabilities involve large adhesion force discontinuities and substantial water mass reconfiguration with water flow in an extremely short time, which makes the process transient. The reconfigurations can reduce the original multi-grain water clusters to four-, three- and two-grain clusters by way of three different instability modes: of thin-sheet instability, or meniscus snap-through instability, depending on the sign of the Gauss curvature of the liquid surface, or finally, for two-grain bridges only, a liquid wire pinch-off. For larger meso-scale assemblies, however, the global adhesion-force evolution is little affected by the jumps. The air entries are potential sites for drying cracks. The (approximately) calculated capillary pressure for two- and three-grain clusters, in no cases is seen to reach high values, predicted from water retention curves.

Engineering↗

MODELING OF ENHANCED AIR DEHUMIDIFICATION THROUGH ELECTRICALLY CHARGED VAPOR CAPTURING ELECTROSTATIC DROPLETS

This paper investigated the potential of a new electrostatic-based water vapor separation system for humidity control in buildings. The Electrospray Vortical Flow eXchanger (EVFX) consists of small electrically charged water droplets released inside air vortexes to attract water vapor molecules, effectively wiping out the humidity from the air. Larger droplets are then removed at the outer wall of the vortex. If a water molecule is placed in a gradient electric field, such a polar molecule experiences a dielectrophoresis force, which moves the molecules and produces a vapor concentration gradient. When the vapor density exceeds the saturation level, nucleation occurs. A thermodynamic model that captures this phenomenon was described in this paper. Electrosprayed droplets were initially charged close to their maximum electrical charge dictated by the Rayleigh limit; these droplets were used as nucleation centers. The high electric charge decreased the pressure of the vapor, which was in equilibrium with the droplets. This enhanced the charged droplets' nucleation and growth that depleted the vapor phase near the droplets, which was compensated for by the dielectrophoresis flow and diffusion. Significant water vapor condensation was predicted for small droplets at a high electrical charge. Beyond a specific droplet size, while the condensation of water vapor was still theoretically possible, it was somewhat limited because the further growth of the large charged droplets was inhibited due to their high inherent water vapor pressure near the surface. A case study illustrated the potentials and limitation of the EVFX for droplets charged to the Rayleigh limit, for which the effective range of diameters resulted between 10 nm up to few micron.

Morcelli, Stefano↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it is desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilators (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. Although this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and—of greatest concern—outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger heating, ventilating, and air-conditioning (HVAC) systems. The ventilation-integrated comfort system (VICS) is expressly designed to integrate with low-capacity, efficient, ducted heating and cooling systems. Overall, the latest VICS prototype consumed 40–75 watts (W), including the air handler power, to deliver 50–120 cfm of whole-dwelling ventilation. The large, cross-flow ERV core performed to match manufacturer values (73% winter sensible effectiveness, 64% summer total effectiveness), but further improvements are possible. The VICS system researched and tested during this project will provide efficient, controllable, balanced energy recovery ventilation that is integrated with heating and cooling systems. The integration reduces space and ductwork needed for separate ventilation systems, and there are no compromises to heating, cooling, or ventilation performance. The integrated nature of the device also reduces risks for improper installation and commissioning. Even when using the air handler blower to distribute outdoor air, the total power consumption is lower than that of most available ERV products in the same airflow range. This system has the potential to offer very high-performance ventilation with much smoother and simpler installation than conventional systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Behavior of an air-cooled thermosiphon during a non-air gas ingress event

Here, this study investigates the transient response of an air-cooled thermosiphon subjected to a sudden non-air gas ingress event. Results presented are from experimental testing conducted on a large-scale thermal hydraulic facility that examines heat removal performance of the Reactor Cavity Cooling System (RCCS) concept, a passive safety system for advanced nuclear reactors. Relying on buoyancy driven natural circulation flow, these systems feature a series of riser standpipes and coupled chimney network that provide a pathway for heat rejection to the atmosphere. In this work, the facility was modified to allow a transition of the draft intake from normal ambient air, to draft intake from an open-top volume containing high purity argon. Testing began by establishing normal operation and allowing the facility to reach steady-state thermal hydraulic flow conditions with natural air draft. The transitioned sequence was then initiated which simultaneously changed the inlet boundary from open air to a pathway from the quiescent argon volume. This event caused 1,200 cu-feet of the heavy gas, twice the internal volume of total facility flow path, to be drawn into the inlet plenum and ingress into the heated riser standpipes. With the upper chimney network still containing residual air, there was insufficient density difference to maintain buoyancy driven natural circulation. After a period of only 90 s past the ingress event, the facility experienced complete flow stagnation before entering an extended period of severely degraded system flow. Due to the cessation of bulk fluid movement and subsequent failure of its heat removal function, fluid and structural temperatures began to rise sharply. Re-circulation patterns developed within the multiple parallel riser standpipes, where hot gas near the outlets was observed to travel downward and re-enter the inlet of adjacent channels. After approximately 18-minutes, fluid temperatures and their associated density difference rose to a level sufficient to allow reestablishment of buoyancy driven system flow, and ultimately, recovery of facility operation to normal behavior.

42 ENGINEERING↗

Modeling Efforts to Gain Insight into Historical Leak Events from the Single-Shell Tank A-105 in the Hanford 241-A Tank Farm - 20113

The 241-A Tank Farm is a single-shell tank (SST) farm constructed to store process waste from Hanford nuclear operations. Millions of gallons of nuclear waste were stored in the 241-A Tank Farm SSTs and some of the SSTs leaked in the past. In addition, spills and pipeline leaks during transfers and storage and intentional discharges to cribs and trenches resulted in releasing waste to the ground. Tank liner leaks are referred to as 'leaks' and all other discharges to the soil are referred to as 'releases.' Liquid waste that could be removed by pumping has been removed from all of the SSTs to reduce the potential for future leaks. The most significant historical leak event in 241-A Tank Farm occurred in 1965 when tank A-105 experienced a pressurized steam event. This event resulted in damage to the inner steel liner flooring of A-105, which was separated from the sidewalls over part of its circumference and buckled up to 2.5 m, vertically. During this event up to 7,570 L of contaminated liquid may have leaked to the adjacent soil. This leak occurred under extreme temperature and pressure conditions. Modeling efforts to better understand the nature and extent of historical leaks from subsurface SSTs that were used to store highly radioactive, self-boiling liquid wastes at 241-A Tank Farm have recently been undertaken. These efforts have compiled the available historical information to support a preliminary non-isothermal, multiphase flow and chemical transport modeling effort to re-create the conditions under which the leaks occurred and to formulate a conceptual model as to the extent and distribution of leaked radioactive contaminants in the adjacent soil material. The focus of this work was on developing an understanding of the key features, processes and bounding conditions related to tank A-105 leak events that occurred in the 1960's. The activities include estimation of leak composition, non-isothermal multiphase flow and transport modeling, and geochemical modeling. The STOMP{sup C} Water-Air-Energy modeling code was utilized to implement the three-dimensional representation of the subsurface tank and the surrounding flow field. Once constructed, the model was used to evaluate the conceptual understanding of leaks originating from different parts of the tank under the elevated temperature boundary conditions that were imposed by surrounding tanks at the time of the historical leaks. The chemical evolution of the liquid waste was also evaluated as it leaked from the tank under transient pressure and temperature gradients. The results of the preliminary evaluation suggested the presence of a heat-pipe effect beneath tank A-105 in which water vapor at an elevated temperature is driven away from the base of the tank to a position where water vapor cools, condenses and is then drawn back toward the tank by the strong capillary attraction of the dry soil. A non-sorbing contaminant (Tc-99) was introduced into this flow field to better understand the potential distribution patterns of leaked contaminants that may have occurred during the historical leak events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical simulation of an atmospheric pressure plasma jet with coaxial shielding gas

A two-dimensional ( r, z ) numerical simulation of the discharge characteristics of an atmospheric pressure plasma jet (APPJ), with coaxial shielding gas, was performed. The helium working gas flowed in a central capillary tube, engulfing a needle electrode powered by 13.7 MHz radio frequency sinusoidal voltage. The N 2 shielding gas flowed in the annular space of a coaxial tube. These gases emerged, in laminar flow, in a 78%N 2 -21%O 2 -1%Ar dry air ambient. The characteristics of the APPJ with shielding gas were compared to those of the APPJ without shielding gas. The nitrogen shielding gas hindered the diffusion of oxygen and argon from the ambient air into the helium jet. With the shielding gas present, more nitrogen penetrated into the helium core, causing a shorter plasma ‘plume’. The flow rates of the working and shielding gas, critically affected the gas temperature, and in turn the discharge characteristics. For a He flow of 2 standard liters per minute (slm), switching on the nitrogen shielding gas flow (at 4.5 slm) reduced the on-axis O 2 and Ar mole fractions from 3.9 × 10 - 4 to 6.8 × 10 - 5 and from 1.9 × 10 - 5 to 3.3 × 10 - 6 , respectively, at an axial distance of 3 mm downstream of the nozzle. The radial profiles of the mole fractions of the ambient gases were monotonically and strongly decreasing towards the system axis, for short axial distances from the nozzle (~1 mm), but became progressively flatter at longer distances from the nozzle (3 mm and 5 mm). Simulation predictions captured the salient features of experimental data of ambient species mole fractions in the plasma jet, and the 706 nm optical emission intensity profiles of the He 3 3 S excited state.

Physics↗

The influence of surface heat fluxes on the growth of idealized monsoon depressions

This study explores the effect of surface sensible and latent heat fluxes on monsoon depressions using a series of idealized convection-permitting simulations. Each experiment is initialized with a small-amplitude wave that is allowed to grow within an environment representative of the South Asian monsoon. Comparing experiments with and without interactive surface heat fluxes, it is found that these fluxes enhance the growth of the simulated vortices. Without interactive surface fluxes, the strengthening period is short and the vortices fail to reach intensities characteristic of stronger monsoon depressions. Using a large set of experiments in which the vertical and meridional shear are systematically varied, it is found that surface heat fluxes enhance intensity the most when the upper-level shear is weak, the lower-level shear and associated moist static energy (MSE) gradient are sufficiently steep, and the lower-level meridional shear is strong. Here, these experiments reveal two different regimes of convection-coupled monsoon depression growth: one in which convection is driven by MSE advection and one in which it is driven by surface heat fluxes and quasigeostrophic forcing for ascent. Both regimes require sufficiently strong meridional shear to achieve initial growth by barotropic instability.

54 ENVIRONMENTAL SCIENCES↗

Fluid Flow Observations of The Spray Near-Field Using High-Speed X-Ray Imaging

Sprays are important to may industrial processes, but the near-field region where spray formation takes place is difficult to visualize and characterize through visible light imaging because this region is typically optically dense. X-ray imaging is one technique that can penetrate this optically dense region and provide unique observations of the spray formation process. This study uses high-speed white beam X-ray imaging conducted at the Advanced Photon Source to capture spray formation dynamics from a canonical airblast atomizer. In this work, a range of momentum flux ratios are visualized by varying the gas flow rate while the liquid flow rate is held constant. The use of X-rays show overlapping flow structures including bags, ligaments, mushrooms, and webs. Air bubbles are captured within the liquid regions, and a very dynamic crown forms at the liquid needle exit at higher momentum flux ratios. Finally, at the highest momentum flux ratios, air bubbles and liquid droplets are observed migrating upstream in the center of the crown, and this motion is attributed to a toroidal recirculation cell at the nozzle exit.

47 OTHER INSTRUMENTATION↗

Data From Experiments on Bubbling Fluidization of Zeolite in a Rectangular Bubbling Fluidized Bed

Fluidization experiments were conducted in a lab-scale rectangular bubbling fluidized bed with the objective of generating a high-quality dataset for model validation and artificial intelligence/machine learning (AI/ML) training. Zeolite was chosen as the bed material, and the fluidizing medium was air as supplied by a compressor. Three different flow rates at the inlet were chosen such that the particles were fluidized but not elutriated from the system. The test matrix involved randomization and replicates to provide uncertainty estimates as well as four different batches of zeolite as the bed material. The quantities of interest obtained from this study were statistics of differential pressures, interface heights, and particle velocities. Considering all the components of the elaborate test plan, the results obtained were consistent and reproducible. Characterization tests were performed to estimate particle properties including size, density, coefficient of friction, coefficient of restitution, and minimum fluidization velocity. In addition, the angle of repose from granular discharge experiments has been reported to account for rolling friction, though its effect on the overall process is expected to be negligible.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A&L Annual Report: GRM-MAPS

Exploding Bridge Wire (EBW) is an important design for initiating detonators relevant to several LLNL systems. In such designs, a metal bridge wire is in direct contact with a porous secondary high explosive (HE), typically pressed to around 50% of its crystalline density. Initiation is believed to occur through shock waves generated when the bridge wire is made to explode via the rapid passing of a strong current pulse. Permeametry is an important characterization tool for the porous powdered HE (PETN, HMX, etc.) component in such devices. Such powders are well known to coarsen with age, with an accompanying deterioration in performance, which includes increased function time and sensitivity. Among various material characteristics, one that has been shown to correlate the most with such performance parameters is the flow-permeable surface area (FSSA), measured using air-permeametry. Commercially available permeametry apparatuses, such as that from Fisher Scientific or a more modern version from Micromeritics suffer from a few drawbacks, most notably as related to monitoring age-related changes in FSSA. This is because it requires re-compaction of the aged powder into the permeametry tube, which in most cases leads to an unwanted increase in FSSA. To address this and a few other shortcomings, we have been developing a modern version of the permeameter, Gee-Reinstein-Maiti Modern Air-Permeametry System (GRM-MAPS). In this report, we summarize progress made in FY25 toward perfecting and calibrating the instrument, which we aim at deploying within surveillance in FY26.

36 MATERIALS SCIENCE↗

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open millifluidics based on powder-encased channels

Millifluidics, the manipulation of liquid flow in millimeter-sized channels, has been a revolutionary concept in chemical processing and engineering. The solid channels that contain the liquids, though, are not flexible in their design and modification, and prevent contact with the external environment. All-liquid constructs, on the other hand, while flexible and open, are imbedded in a liquid environment. Here, we provide a route to circumvent these limitations by encasing the liquids in a hydrophobic powder in air that jams on the surface, containing and isolating flowing fluids, offering flexibility and adaptability in design, as manifest in the ability to reconfigure, graft, and segment the constructs. Along with the open nature of these powder-contained channels that allow arbitrary connections/disconnections and substance addition/extraction, numerous applications can be opened in the biological, chemical, and material arenas.

36 MATERIALS SCIENCE↗