Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

BioCARS: a synchrotron resource for time-resolved X-ray science

BioCARS, a NIH-supported national user facility for macromolecular time-resolved X-ray crystallography at the Advanced Photon Source (APS), has recently completed commissioning of an upgraded undulator-based beamline optimized for single-shot laser-pump X-ray-probe measurements with time resolution as short as 100 ps. The source consists of two in-line undulators with periods of 23 and 27 mm that together provide high-flux pink-beam capability at 12 keV as well as first-harmonic coverage from 6.8 to 19 keV. A high-heat-load chopper reduces the average power load on downstream components, thereby preserving the surface figure of a Kirkpatrick-Baez mirror system capable of focusing the X-ray beam to a spot size of 90 {micro}m horizontal by 20 {micro}m vertical. A high-speed chopper isolates single X-ray pulses at 1 kHz in both hybrid and 24-bunch modes of the APS storage ring. In hybrid mode each isolated X-ray pulse delivers up to {approx}4 x 10{sup 10} photons to the sample, thereby achieving a time-averaged flux approaching that of fourth-generation X-FEL sources. A new high-power picosecond laser system delivers pulses tunable over the wavelength range 450-2000 nm. These pulses are synchronized to the storage-ring RF clock with long-term stability better than 10 ps RMS. Monochromatic experimental capability with Biosafety Level 3 certification has been retained.

43 PARTICLE ACCELERATORS↗

DND-CAT;s new triple area detector system for simultaneous data collection at multiple length scales

The DuPont-Northwestern-Dow Collaborative Access Team (DND-CAT) built and currently manages sector 5 at the Advanced Photon Source (APS), Argonne National Laboratory. One of the principal techniques supported by DND-CAT is Small and Wide-Angle X-ray Scattering (SAXS/WAXS), with an emphasis on simultaneous data collection over a wide azimuthal and reciprocal space range using a custom SAXS/WAXS detector system. A new triple detector system is now in development, and we describe the key parameters and characteristics of the new instrument, which will be faster, more flexible, more robust, and will improve q-space resolution in a critical reciprocal space regime between the traditional WAXS and SAXS ranges.

43 PARTICLE ACCELERATORS↗

Radiation-induced decomposition of explosives under extreme conditions

We present high-pressure and high temperature studies of the synchrotron radiation-induced decomposition of powder secondary high explosives pentaerythritol tetranitrate (PETN) and 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) using white beam synchrotron radiation at the 16 BM-B and 16 BM-D sectors of the HP-CAT beamline at the Advanced Photon Source. The radiation-induced decomposition rate TATB showed dramatic slowing with pressure up to 26.6 GPa (the highest pressure studied), implying a positive activation volume of the activated complex. The decomposition rate of PETN varied little with pressure up to 15.7 GPa (the highest pressure studied). Diffraction line intensities were measured as a function of time using energy-dispersive methods. By measuring the decomposition rate as a function of pressure and temperature, kinetic and other constants associated with the decomposition reactions were extracted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RIXS, XEOL and XEOL Imaging of Rare-earth Phosphors at the L3,2-edges

Capabilities at the PNC-XOR of the Advanced Photon Source to monitor Resonant Inelastic X-ray Scattering (RIXS) in the intermediate X-ray energy range using a wavelength dispersive spectrometer (WDX) and associated X-ray Excited Optical Luminescence (XEOL) using an optical spectrometer will be described. Ce L3 -edge of Ce and Tb doped inorganic phosphors have been investigated using these techniques and corresponding X-ray Absorption Near-Edge Structures (XANES) using a micro X-ray beam with X-ray fluorescence and optical luminescence yield. Results from these studies and their prospects for future applications in XEOL imaging will be discussed.

43 PARTICLE ACCELERATORS↗

FPGA-based compression of streaming x-ray photon correlation spectroscopy data

A data acquisition system to perform real-time background subtraction and lower-level-discrimination-based compression of streaming x-ray photon correlation spectroscopy (XPCS) data from a fast charge-coupled device (CCD) area detector has been built and put into service at the Advanced Photon source (APS) at Argonne National Laboratory. A commercial frame grabber with on-board field-programmable gate array (FPGA) was used in the design, and continuously processes 60 frames per second each consisting of 1,024 x 1,024 pixels with up to 64512 photon hits per frame.

43 PARTICLE ACCELERATORS↗

In Situ Sample Environment for Studying Corrosion of Nuclear Materials

Currently there is lack of fundamental understanding of kinetics and reaction mechanisms that occur at nuclear cladding-steam interface under extreme environments in the nuclear reactors. Such understanding is vital to design and develop advanced cladding materials for more economical and safer nuclear power. We present advanced in situ sample environment for probing solid-fluid interfaces using high resolution synchrotron methods for studying early stages of corrosion including development of oxide layer as corrosion proceeds. Both X-ray diffraction and X-ray fluorescence methods will be discussed to probe structural and elemental composition changes under steam environment using corrosion resistant cell at high temperatures. High intensity and brightness of synchrotron coupled with advanced in situ sample environment developed, presents an opportunity to understand the fundamental interfacial processes involved in degradation of materials. The in situ sample environment is optimized for XRD and XRF data collection at NSLS-II and will be available to all users through the proposal process. The in situ sample environment is built to study the interfacial interactions at temperatures and pressures up to 400 deg. C and 1500 psi. It consists of three main parts; the distribution manifold, the pressure vessel, and the reaction cell as shown in Figure 1. Water is allowed to heat up to 350 deg. C inside the pressure vessel to produce steam which is delivered to reaction cell using insulated delivery system. The cell design is adapted from J. Diefenbacher, et. al. However, it is modified for corrosion applications in steam environments. The reaction cell and sample holder are made from hastelloy due to its high corrosion resistance. The reaction cell is surrounded by copper heating block to control its temperature independently from the rest of the system. Lab view based platform is developed for remote monitoring of pressure and temperature. The sample environment was commissioned at 6-IDD beamline in the Advanced Photon Source, for grazing incidence XRD corrosion studies. Metallic Zr sample (200 μm thickness) was used due to its faster oxidation kinetics as compared to Zircaloy. Sample was exposed to steam at 350 deg. C and 50 psi for a total time of 64 hours. Results showed the presence of α-Zr as the dominant phase. After 32 hours of exposure to steam, three oxide peaks in the low diffraction angle side started to develop with time. These peaks are attributed to the growth of substoichiometric zirconium oxide phases (Zr{sub 3}O and Zr{sub 3}O{sub 1-x}). (authors)

36 MATERIALS SCIENCE↗

Asymmetric-cut variable-incident-angle monochromator

A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18 deg. asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage ({Phi}) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation ({Psi}) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation ({Theta}) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

43 PARTICLE ACCELERATORS↗

Carbon Mineralization by Aqueous Precipitation for Beneficial Use of CO2 from Flue Gas

Calera's innovative Mineralization via Aqueous Precipitation (MAP) technology for the capture and conversion of CO{sub 2} to useful materials for use in the built environment was further developed and proven in the Phase 1 Department of Energy Grant. The process was scaled to 300 gallon batch reactors and subsequently to Pilot Plant scale for the continuous production of product with the production of reactive calcium carbonate material that was evaluated as a supplementary cementitious material (SCM). The Calera SCM{trademark} was evaluated as a 20% replacement for ordinary portland cement and demonstrated to meet the industry specification ASTM 1157 which is a standard performance specification for hydraulic cement. The performance of the 20% replacement material was comparable to the 100% ordinary portland cement control in terms of compressive strength and workability as measured by a variety of ASTM standard tests. In addition to the performance metrics, detailed characterization of the Calera SCM was performed using advanced analytical techniques to better understand the material interaction with the phases of ordinary portland cement. X-ray synchrotron diffraction studies at the Advanced Photon Source in Argonne National Lab confirmed the presence of an amorphous phase(s) in addition to the crystalline calcium carbonate phases in the reactive carbonate material. The presence of carboaluminate phases as a result of the interaction of the reactive carbonate materials with ordinary portland cement was also confirmed. A Life Cycle Assessment was completed for several cases based on different Calera process configurations and compared against the life cycle of ordinary portland cement. In addition to the materials development efforts, the Calera technology for the production of product using an innovative building materials demonstration plant was developed beyond conceptual engineering to a detailed design with a construction schedule and cost estimate.

43 PARTICLE ACCELERATORS↗

XAFS Study of Epitaxial Co[subscript x]Ti[subscript 1-x]O[subscript 2-x] Anatase

Co doped TiO{sub 2}-anatase is a promising candidate for a room-temperature ferromagnetic semiconductor. XAFS measurements have been used to investigate the local Co environment and Co valence for several Co-anatase films. The samples were grown on LaAlO{sub 3} (001) by oxygen plasma assisted molecular beam epitaxy and on SrTiO{sub 3} by atomic oxygen assisted MBE. Co concentrations were about 5%. The measurements were made at the PNC-CAT bending magnet and undulator beamlines at the Advanced Photon Source. For the films on LaAlO{sub 3}, the near edge clearly shows the presence of only Co(2+), and no evidence for metallic Co, while the films on SrTiO{sub 3} showed significant metallic Co. Analysis of the extended fine structure for the LaAlO{sub 3} films finds that the Co substitutes for Ti with some distortion of the lattice. Both in-plane and out-of-plane Co-O bonds are expanded from the Ti-O bonds in anatase. The in-plane bonds are expanded approximately twice as much. A deficit in the oxygen coordination number suggests a correlation of oxygen vacancies with Co sites.

36 MATERIALS SCIENCE↗

X-ray characterization of low-thermal conductivity thin-film materials.

X-ray diffraction and imaging techniques at the Advanced Photon Source (APS) have been used to characterize PbSe/MoSe{sub 2} and PbSe/WSe{sub 2} thin films and multilayers. Diffraction measurements with area detectors were made to demonstrate the nanoscale coherence size of the layers both in-plane and perpendicular to the surface. Higher-resolution diffraction measurements that exploit the tunability of synchrotron radiation for anomalous scattering contrast have been used to accurately determine layer spacings in these multilayers. We also discuss opportunities in other new and emerging x-ray techniques, such as time-resolved studies during growth or processing, and present x-ray imaging capabilities that can be used to investigate thermoelectric thin-film materials.

43 PARTICLE ACCELERATORS↗

Study of precision weak-link stage systems with large travel range and sub-nanometer-scale resolution

To use x-ray optics with nanometer resolution limit, scanning x-ray nanoprobes with corresponding mechanical positioning capability need to be designed. In particular, positioning stages with both sub-nanometer resolution and a positioning/scanning range of several millimeters are required. Based on our design of precision weak-link stages with interferometric encoders for the Center for Nanoscale Materials (CNM) hard x-ray nanoprobe at the Advanced Photon Source (APS) Sector 26, we have developed a new two-dimensional (2-D) weak-link stage system for nanopositioning of a specimen holder. This system provides sub-nanometer resolution, coupled with sub-nanometer metrology at a travel range of several millimeters. The 2-D weak-link stage system is designed with high structure stiffness using laminar overconstrained weak-link mechanisms [4-6]. In this paper we present the study of a linear precision weak-link stage system with sub-centimeter travel range and sub-nanometer positioning resolution. Design of a rotary weak-link stage system with 10-nrad resolution and 10-degree-level travel range is also discussed in this paper.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cryogenic performance of a cryocooler-cooled superconducting undulator

A cryocooler-cooled superconducting undulator has been installed and operated with beam at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The device consists of a dual-core 42-pole magnet structure that is cooled to 4.2 K with a system of four cryocoolers operating in a zero-boil-off configuration. This effort represents the culmination of a development program to establish concept feasibility and evaluate cryostat design and cryocooler-based refrigeration. Cryostat performance is described including cool-down/warm-up, steady-state operation, cooling margin, and the impact of beam during operation in the APS storage ring. Plans for future devices with longer magnets, which will incorporate lessons learned from the development program, are also discussed.

43 PARTICLE ACCELERATORS↗

Note: Loading method of molecular fluorine using x-ray induced chemistry

We have successfully loaded molecular fluorine into a diamond anvil cell at high pressure using the synchrotron x-ray induced decomposition of perfluorohexane (C{sub 6}F{sub 14}). “White” x-ray radiation from the Advanced Photon Source was used to initiate the chemical decomposition of C{sub 6}F{sub 14}, which resulted in the in situ production of F{sub 2} as verified via Raman spectroscopy. Due to the toxic nature of fluorine, this method will offer significant advantages in the ability to easily load a relatively nontoxic and inert substance into a chamber (such as a diamond anvil cell) that, when sealed with other reactants and irradiate with hard x-rays (>7 keV), releases highly reactive and toxic fluorine into the sample/reaction chamber to enable novel chemical synthesis under isolated and/or extreme conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Observations on COTR due to the Microbunching Instability in Compressed Beams

The observations of the strong enhancements of the optical transition radiation (OTR) signal observed after bunch compression of photocathode beams in the Advanced Photon Source (APS) linac chicane continue to be of interest. These effects have been attributed to a microbunching instability. Recent tests with an Oriel spectrometer with ICCD readout have extended our COTR spectral studies. In this case we used a microchannel plate image intensifier with a GaAs photocathode to explore the NIR regime out to 880 nm. We report for the first time an {approx}40% intensity modulation of {approx}25-nm period throughout the observed broadband COTR spectra for some localized spatial structures. In addition, the observation of a ring-like COTR image structure in x-y space for a mismatched beam at 355 MeV and a COTR mitigation concept is presented and discussed.

43 PARTICLE ACCELERATORS↗

The inverse problem of bimorph mirror tuning on a beamline

One of the challenges of tuning bimorph mirrors with many electrodes is that the calculated focusing voltages can be different by more than the safety limit (such as 500 V for the mirrors used at 17-ID at the Advanced Photon Source) between adjacent electrodes. A study of this problem at 17-ID revealed that the inverse problem of the tuning in situ, using X-rays, became ill-conditioned when the number of electrodes was large and the calculated focusing voltages were contaminated with measurement errors. Increasing the number of beamlets during the tuning could reduce the matrix condition number in the problem, but obtaining voltages with variation below the safety limit was still not always guaranteed and multiple iterations of tuning were often required. Applying Tikhonov regularization and using the L-curve criterion for the determination of the regularization parameter made it straightforward to obtain focusing voltages with well behaved variations. Some characteristics of the tuning results obtained using Tikhonov regularization are given in this paper.

43 PARTICLE ACCELERATORS↗

Imaging of cochlear tissue with a grating interferometer and hard X-rays

This article addresses an important current development in medical and biological imaging: the possibility of imaging soft tissue at resolutions in the micron range using hard X-rays. Challenging environments, including the cochlea, require the imaging of soft tissue structure surrounded by bone. We demonstrate that cochlear soft tissue structures can be imaged with hard X-ray phase contrast. Furthermore, we show that only a thin slice of the tissue is required to introduce a large phase shift. It is likely that the phase contrast image of the soft tissue structures is sufficient to image the structures even if surrounded by bone. For the present set of experiments, structures with low-absorption contrast have been visualized using in-line phase contrast imaging and a grating interferometer. The experiments have been performed at the Advanced Photon Source at Argonne National Laboratories, a third generation source of synchrotron radiation. The source provides highly coherent X-ray radiation with high-photon flux (>10{sup 12} photons/s) at high-photon energies (5-70 keV). Radiographic and light microscopy images of the gerbil cochlear slice samples were compared. It has been determined that a 20-{micro}m thick tissue slice induces a phase shift between 1/3{pi} and 2/3{pi}.

43 PARTICLE ACCELERATORS↗

Some aspects of achieving an ultimate accuracy during insertion device magnetic measurements by a Hall probe

An extensive test of a new Senis 2-axis Hall probe was done at the Advanced Photon Source using the Undulator A device and calibration system. This new probe has clear advantages compared with previously used Bell and Sentron Hall probes: very stable zero offset (less than the noise of 0.026 G) and compensated planar Hall effect. It can be used with proper calibration even for first and second field integral measurements. A comparison with reference measurements by long stretched coil shows that the difference in the first field integral measurement results for a 2.4-m-long Undulator A device is between 17 G cm for the best of four Hall probes used for the test and 51 G cm for the worst of them for all gap ranges from 10.5 mm to 150 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗