Search NASA⌕ Search

SEARCH · Search NASA

Results for “Air mass”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Recovery of Natural Gas Equipment Emissions into Gas Compression Engines for the Reduction of Potential Greenhouse Gas Emissions

Since the turn of the millennium, the United States (U.S.) oil and natural gas (ONG) industry has nearly doubled its natural gas production rate. As a result, the ONG industry has recently come under increasing scrutiny for its contributions to greenhouse gas (GHG) emissions. Consequently, various solutions to this problem have been proposed and formulated to reduce the impacts of GHG emissions on the environment. West Virginia University (WVU) have found it important to research the impacts of recovering vented gas streams into prime-mover engines. The U.S. Department of Energy (DOE) and National Energy Technology Laboratory (NETL) have granted WVU funding to research and develop a “Methane Mitigator” (M2) - a “Scalable Vent Mitigation Strategy to Simultaneously Reduce Methane Emissions and Fuel Consumption from the Compression Industry.” One of the main areas of interest for this research was the collection of emissions from natural gas equipment into a Caterpillar G3508J natural gas compression engine. The parameters being analyzed from the engine were brake-specific emissions and power output. The emissions sources considered for this research were pneumatic controllers (PCs), reciprocating compressor vents, and the engine’s open crankcase breather. The compressor vent and PC emissions were simulated using a mass flow controller (MFC) and flowed into the engine using two separate methods: (1) directly into the air intake, and (2) through a retrofitted closed crankcase ventilation system (CCV), serving as a buffer volume. The crankcase emissions were quantified without the CCV, and the impact on exhaust emissions from circulating the crankcase gases into the intake was measured. The simulated compressor vent and PC flows from the MFC had limited effect on the steady state operation of the engine and resulting performance. When the simulated flows were fed directly into the engine’s air intake, the changes within the engine’s continuous performance and emission parameters were larger but lasted for shorter durations. Conversely, when the simulated flows were fed into the CCV before entering the air intake, the changes in the engine’s performance and emission parameters were less pronounced for continuous analysis but lasted for longer durations. In either case, the continuous emission changes in both emissions and performance varied in size depending on the test scenario being run, but the cycle average changes in emissions and performance showed little impact overall compared to the engine’s baseline operation. As a result, the inclusion of a CCV shows a decrease in baseline carbon dioxide equivalent (CO2-eq.) engine emissions (from combined exhaust and open crankcase) of almost 4%. Likewise, the CCV inclusion reduced baseline total methane (CH4) from combined exhaust and open crankcase by upwards of 16%. These atmospheric emissions only decreased further with the inclusions of collected PC and compressor vent flows. The resulting changes in time-averaged rated exhaust behavior (or lack thereof) prove that the proposed M2 system could likely be deployed at sites with modern lean-burn natural gas engines as a viable option for reducing and eliminating potential GHG sources that would have otherwise been unutilized as energy sources.

03 NATURAL GAS↗

Completion of initial reduced-order model for flammable refrigerant dispersal in residential spaces

Environmental regulations aimed at reducing global warming impacts of HVAC&R refrigerants have resulted in the phase-out of chlorofluorocarbons (CFCs) in 2010 and hydrochlorofluorocarbons (HCFCs) by 2030 in developed countries with additional restrictions on the use of hydrofluorocarbons (HFCs) set to take effect in 2036. Many of the remaining alternative refrigerants that have lower global warming potential (GWP) and that are suitable for use in HVAC&R systems (e.g., propane, difluoromethane) are flammable to some degree. Flammable refrigerants introduce new challenges and hazards to property and personal safety related to potential deflagration during system maintenance or due to leakage of the refrigerant accumulating in the conditioned space. Standards have been developed to set maximum charge limits for flammable refrigerants in HVAC&R systems; however, existing safety standards and codes still restrict their use. The bodies that maintain and update these codes need publicly available, science-based information to enable credible guidelines for setting safe charge limits for different flammable refrigerants in different HVAC&R applications. In 2016, the Alliance for Responsible Atmospheric Policy, the Air-Conditioning Heating and Refrigeration Institute (AHRI), ASHRAE, the U.S. Department of Energy (DOE), and the State of California began efforts to develop such information. As part of this effort, Oak Ridge National Laboratory (ORNL) began the current, ongoing project to examine imposed charge limits for flammable refrigerants and identify reasonable adjustments to these limits when found appropriate. Past tasks under this project have included development of experimentally vetted, computational fluid dynamics (CFD) simulation approaches to study the results of leakage of flammable refrigerants from various HVAC&R systems into different types of commercial and residential spaces. In this report, we discuss recent efforts to develop a predictive model of the flammable volume fraction and accumulated refrigerant mass in a single-room residential space resulting from the leak of a flammable refrigerant from a small room air conditioning (RAC) unit. The eventual goal is development of a model suitable for public release which could simulate a range of scenarios. In discussions with the AHRTI Flammable Refrigerant Subcommittee (FRS) at the beginning of this effort, a total of 9 input parameters were chosen for consideration including room area, room/door opening area, ventilation fan flow rate, unit/leak height, leak area, leak rate, total refrigerant charge, refrigerant molecular weight, and state of the unit fan.

42 ENGINEERING↗

Towards retrieving cloud top entrainment velocities from MISR cloud motion vectors

Although important, direct retrievals of entrainment rates in cloud-topped planetary boundary layer (PBL) remain elusive. Here we present a novel technique for retrieving cloud-top entrainment velocities using only Multi-angle Imaging Spectro-Radiometer (MISR) stereoscopic retrievals of cloud-motion vectors (CMVs) and cloud-top heights (CTHs). Mesoscale vertical air velocity at CTH is diagnosed from the continuity equation and then used to derive entrainment velocities from the PBL mass-budget equation. The algorithm is demonstrated through a case of marine stratocumulus deck off the California coast, with comparisons made against data from the European Centre for Medium-range Weather Forecasts (ECMWF) reanalysis (ERA5) and the data from other satellites. MISR low-cloud CTH for this case were lower than the ERA5 reported PBL depth by 189 ± 87 m. These differences in cloud top heights partly modulate the differences in the ERA5 and MISR horizontal winds, with larger differences in meridional over zonal wind components. Average difference between ERA5 and MISR derived mesoscale vertical air motion at cloud top was 0.14 ± 0.73 cm s −1 , while the same for entrainment rate was −0.09 ± 0.46 cm s −1 . The uncertainties in the utilized CTHs and CMVs are propagated to derive systematic and random retrieval uncertainties. Fractional uncertainty is lower than 25 % when the retrieved mesoscale vertical air motion is stronger than ±0.04 cm s −1 and entrainment velocities are stronger than ±0.03 cm s −1 . These results showcase the ability to derive mesoscale vertical air motion and entrainment rates from MISR observations and motivate its extension to generate a global climatology leveraging its full 23-year record (2000–2022). Nonetheless comprehensive validation of the retrievals is warranted through comparisons with estimates from an independent dataset across diverse weather conditions.

Mitra, Arka [Argonne National Laboratory (ANL), Ar↗

Controlling saturation to improve per- and polyfluoroalkyl substance (PFAS) removal in biochar-amended stormwater bioretention systems

Black carbon-amended bioretention systems are an increasingly popular strategy for the removal of organic contaminants, including poly- and perfluoroalkyl substances (PFASs) and other trace organic contaminants (TOrCs), from urban stormwater. Many PFASs preferentially accumulate at the air–water interface, but detention time requirements for stormwater bioretention systems typically result in full saturation of the bioretention systems, effectively removing their air–water interfaces. This study assessed the effect of bioretention system saturation on removal of PFASs, metals, and hydrophilic TOrCs. A field-aged mixture of 40% v/v sand, 30% v/v zeolite, and 30% v/v biochar was packed into columns which were operated with hydraulic controls to remain unsaturated or fully saturated throughout the duration of the experiment. Twenty-four storm events sized to a 95th percentile storm at a California, United States military site were simulated using synthetic stormwater fortified with aqueous film forming foam-derived PFASs, TOrCs, and metals to mimic real-world conditions. Unsaturated conditions outperformed saturated conditions for removal of all PFASs analyzed. A simulated inadvertent system perturbation (i.e. flooding event) in the unsaturated columns did not result in significantly greater mobilization of PFAS mass, suggesting that more sorption to the biochar occurred as a result of the transient retention of PFASs at the air–water interface reducing kinetic sorption limitations. Overall, maintaining unsaturated conditions in a biofilter may extend the sorptive filter lifetime for PFASs by up to 83%. The results have implications for bioretention system application and design for PFAS removal in contaminated catchment areas.

13 HYDRO ENERGY↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.

42 ENGINEERING↗

Visualizing bleb mass dynamics in single cells using quantitative phase microscopy

Understanding biological responses to directed energy (DE) is critical to ensure the safety of personnel within the Department of Defense. At the Air Force Research Laboratory, we have developed or adapted advanced optical imaging systems that quantify biophysical responses to DE. One notable cellular response to DE exposure is the formation of blebs, or semi-spherical protrusions of the plasma membrane in living cells. In this work, we demonstrate the capacity of quantitative phase imaging (QPI) to both visualize and quantify the formation of membrane blebs following DE exposure. QPI is an interferometric imaging tool that uses optical path length as a label-free contrast mechanism and is sensitive to the non-aqueous mass density, or dry mass, of living cells. Blebs from both CHO-K1 and U937 cells were generated after exposure to a series of 600 ns, 21.2 kV/cm electric pulses. These blebs were visualized in real time, and their dry mass relative to the rest of the cell body was quantified as a function of time. It is our hope that this system will lead to an improved understanding of both DE-induced and apoptotic blebbing.

Steelman, Zachary A.↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Water Mass Transformation in the Southern Ocean: The Role of Eddies Revisited

The water mass transformation (WMT) framework describes how water of one class, such as a discrete interval of density, is converted into another class via air–sea fluxes or interior mixing processes. Here, this paper investigates how this process is modified at the surface when mesoscale ocean eddies are present, using a state-of-the-art high-resolution climate model with reasonable fidelity in the Southern Ocean. The method employed is to coarse-grain the high-resolution model fields to remove eddy signatures, and compare the results with those from the full model fields. This method shows that eddies reduced the WMT by 2–4 Sv (10%–20%; 1 Sv ≡ 10 6 m 3 s −1 ) over a wide range of densities, from typical values of 20 Sv in the smoothed case. The corresponding water mass formation was reduced by 40% at one particular density increment, namely, between 1026.4 and 1026.5 kg m −3 , which corresponds to the lighter end of the range of Indian Ocean Mode Water in the model. The effect of eddies on surface WMT is decomposed into three terms: direct modulation of the density outcrops, then indirectly, by modifying the air–sea density flux, and the combined effect of the two, akin to a covariance. It is found that the first and third terms dominate, i.e., smoothing the outcrops alone has a significant effect, as does the combination of smoothing both outcrops and density flux distributions, but smoothing density flux fields alone has little effect. Results from the coarse-graining method are compared to an alternative approach of temporally averaging the data. Implications for climate model resolution are also discussed.

54 ENVIRONMENTAL SCIENCES↗

Experimental and theoretical analysis of carbon driven detonation waves in a heterogeneously premixed Rotating Detonation Engine

Coal dust explosions can be hazardous; however, they can also generate a significant rise in stagnation pressure if adequately harnessed. Rotating detonation combustors seek to take advantage of the stagnation pressure rise phenomenon in a more sustained and controlled manner via confinement to a physical annulus, leading to increased overall thermodynamic efficiency. Here this investigation presents an analysis of detonations fueled by Carbon Black, a solid particulate consisting of virtually pure carbon molecules and lean Hydrogen-Air mixtures. It is realized that with the addition of Carbon Black, an increase of lean mixture detonability and detonation velocities extending the operating limit over that of a pure hydrogen-air mixture is experienced. For all testing conditions, the total equivalence ratio is held at φ = 1, while the fuel mixture's carbon mass fraction is increased from 0 to 0.7 while the hydrogen is decreased. Detonation wave velocities are extracted from high-speed imaging through applying a Discrete Fourier Transform algorithm to determine changes to the wave speed as Carbon Black particles are introduced. As a result, due to the addition of Carbon Black as an auxiliary fuel source, detonations were formed instead of deflagrations in operating conditions where one would expect deflagrations at the same hydrogen-air equivalence ratios without Carbon Black addition. The detonation formation provides evidence that the coal particles are reacting within the detonation wave in a large enough capacity to support a detonation wave within the annulus. Furthermore, the wave speed is shown to increase with the additional of carbon particles. At a constant global equivalence ratio, the detonation wave velocities were found to decrease with hydrogen's incremental replacement with coal particles. Whereby, through a theoretical comparison of the heat of combustion as computed from the experimentally derived detonation wave velocities, a linear relationship of the two was shown to exist. Therefore, the heat of combustion has the potential to describe an operational limit to sustaining a detonation wave.

42 ENGINEERING↗

On the validity and limitations of 1D model for heat and mass transfer performance evaluation in a multilayer binder-free desiccant dehumidifier: isothermal dehumidification with internal cooling

Efficient humidity control is essential for maintaining indoor thermal comfort, yet conventional vapor-compression-based dehumidifiers are energy-intensive. Employing separate sensible and latent cooling through desiccant-coated heat exchangers (DCHEs) combined with evaporative coolers offers energy savings of up to 80 % compared to conventional systems. However, the dehumidification performance of DCHEs remains limited due to the use of polymer binders for coating desiccant materials onto heat exchange surfaces. In our previous study, we developed a multilayer fixed-bed binder-free desiccant dehumidifier (MFBDD) that demonstrated high dehumidification capacity and low pressure drop compared to rotary desiccant wheels. Nevertheless, its potential for further enhancement through internal cooling and the use of step-shaped adsorption isotherms has not been explored. In this study, a physics-based one-dimensional (1D) transient model is developed and validated to capture the coupled heat and mass transfer processes in the MFBDD and extended to simulate internal cooling using a high-capacity composite metal–organic framework, MIL-101/GO-6 (water uptake ≈1.6 g/g within 35–47 % RH). The model enables detailed analysis of local air and bed temperature dynamics and quantifies how internal cooling affects the dehumidification performance under a wide range of operating conditions. Results show that integrating internal cooling and using MIL-101/GO-6 enhance mass adsorbed, moisture removal capacity, and dehumidification effectiveness by 50 %–99 % compared with the M.S. Gel baseline. The study further reveals that achieving near-isothermal operation requires simultaneous enhancement of the convective heat transfer coefficient and heat exchange surface area. In conclusion, this work provides the first detailed physical insight into the interplay between internal cooling and step-shaped isotherms in a binder-free desiccant device and establishes a validated modeling framework for scaling up and system-level performance evaluation of next-generation energy-efficient dehumidification systems.

Heat and mass transfer↗

Review and Summary of Corrosion Behavior for Aluminum-Clad Spent Nuclear Fuel in Dry Storage

A description of the corrosion behavior of aluminum alloys used for cladding on aluminum-based, aluminum-clad nuclear fuel used in research reactors under potential dry storage conditions has been compiled. An evaluation is made of potential additional corrosion with water postulated to not be removed during drying. The relative humidity (RH) produced by typical dryness criteria for industrial spent nuclear fuel drying is expected to be low, particularly at high temperatures (17% RH at 20°C and lower at higher temperatures). Existing corrosion data suggests that negligible vapor-phase corrosion of aluminum is expected at such low humidity, even for nominally bare aluminum surfaces. That is, the predicted relative humidity from free water (e.g., 17% RH) is below the “critical” relative humidity (~40% RH at room temperature), below which no significant corrosion is observed for bare aluminum. Furthermore, reported room-temperature corrosion rates are very low even under saturated (100% RH) water vapor. Existing results showing significant vapor-phase corrosion corresponded specifically to conditions of high temper ed with high relative humidity. A relatively large reservoir of (chemically bound) water exists in the aluminum (oxy)hydroxide films on the SNF cladding surface. The estimated total could saturate the gas even at relatively high temperature if fully released; however, its release as molecular water is expected to only be plausible if the temperature during storage exceeds both the drying temperature and the threshold for thermal decomposition of the trihydroxides (~220°C). Therefore, the combination of high temperature and high relative humidity that could drive significant corrosion is considered implausible during sealed dry storage following an appropriate drying process, to include >220°C drying for canisters that may approach or exceed this temperature during storage. Vapor-phase testing of aluminum samples with an adherent (oxy)hydroxide layer, prepared in liquid water to resemble those on actual aluminum-clad spent nuclear fuel (ASNF), did not observe evidence of additional corrosion even at combined high-temperature (up to 180°C) and high-humidity (up to 100% RH) conditions. Instead, small net mass losses were observed for most specimens and attributed to dehydration of the samples, which had been air-dried only prior to testing. ASNF being moved to dry storage is expected to have an existing (oxy)hydroxide film, suggesting that the cladding will be less prone to additional corrosion than bare aluminum metal. If significant corrosion did occur during sealed storage, the overall extent and impact is expected to be small. Corrosion post-closure of a canister would not alter the total amount of hydrogen in the canister, so it would have no effect on the maximum H 2 release already assessed in existing bounding calculations. In addition, the total amount of water in a 25-µm dense bayerite film would consume a only ~8 µm additional aluminum metal on average, if fully consumed by oxidizing aluminum metal to Al 2 O 3 . These conclusions are consistent with ASNF-in-canister simulations to date, which included a reaction pathway for corrosion using kinetics from previous literature and believed to be conservative and predicted very low rates of corrosion.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CaptureFOAM

CaptureFOAM provides utilities for fast and accurate direct air capture (DAC) contactor simulations, based on the OpenFOAM framework. At the core, CaptureFOAM is a suite of mass transfer and chemistry models built upon the OpenFOAM thin film model, which allows coarser mesh resolution and less constrictive time step requirements when compared to a traditional volume of fluid approach. This allows CaptureFOAM to conduct device-scale simulations for complex geometries including commercial packing materials and novel contactor shapes, matching experimental results in a wide variety of applications.

Kincaid, Kellis [Oak Ridge National Laboratory (OR↗

Use of in Situ Synchrotron Techniques to Probe the Oxidized Surface of Molybdenum Nitride Oxygen Reduction Electrocatalysis

The development of active and stable earth-abundant catalysts for the oxygen reduction reaction (ORR) is needed for widespread, economic development of fuel cell technologies. Designing and optimizing these non-platinum group metals is challenging, however, because they are susceptible to composition and structure changes, including dissolution, oxidation, and corrosion, both in air and under reaction conditions. To identify the active surface, and thus understand the properties that affect activity, the catalyst surface must be characterized in situ. Herein, we utilize a grazing incidence electrochemical cell to investigate in situ composition and morphology changes of a molybdenum nitride (Mo-N) thin film catalyst using grazing incidence x-ray absorption spectroscopy (GI-XAS) and x-ray reflectivity (XRR). In rotating ring disk electrode measurements, we find that the activity, selectivity, stability, and capacitance of the Mo-N catalyst is dependent on the maximum potential to which it has been exposed. Specifically, the overpotential required to reach -2 mA cm-2geo decreases by over 90 mV when the maximum potential is increased from 0.3 to 0.8 V vs RHE (Figure 1). Because the Mo-N oxidizes rapidly in air, ex situ characterization methods including x-ray photoelectron spectroscopy and time-of-flight secondary ion mass spectrometry can provide only limited insight into these in situ catalyst changes. Using in situ GI-XAS measurements at applied potentials between 0.3 and 0.9 V vs RHE, however, we are able to determine that the surface of the film oxidizes and becomes more amorphous when exposed to increasingly higher potentials (Figure 1). Furthermore, the surface remains oxidized on the order of several hours when returned to "ORR relevant potentials" (< 0.6 V vs RHE), indicating that this surface-oxidized nitride is the active surface for ORR. Using in situ XRR measurements, we find that there is no change in surface roughness at potentials below 0.7 V vs RHE, but the film roughens significantly at 0.8 V vs RHE, correlating with ex situ measurements of Mo dissolution at this potential (Figure 1). We therefore conclude that the intrinsic activity of the Mo-N catalyst increases when exposed to potentials up to 0.7 V vs RHE, while above that potential activity enhancements are due to the exposure of more active sites through dissolution. The in situ electrochemical surface-sensitive x-ray characterization as used here is a promising methodology for understanding and leveraging surface dynamics to improve the performance of non-traditional catalysts.

Kreider, Melissa↗

In Hot Water! The Challenges and Barriers of Decarbonizing Water Heating in Multifamily Buildings: Preprint

Domestic hot water heating is responsible for 32% of the total energy consumption in multifamily buildings and offers a significant decarbonization opportunity. An extensive market assessment was conducted to understand and document key technical and economic barriers to electrification of domestic water heating in multifamily buildings throughout the U.S. Through the program, 77 interviews were conducted to understand key market drivers and technical challenges associated with electrification of water heating systems in both retrofit and new construction scenarios. Interviewees encompassed a wide range of stakeholders in the ecosystem surrounding water heating systems, including suppliers, manufacturers, designers, owners, utilities, and developers. This paper documents key interview takeaways, including an extensive list of market barriers, technical challenges, and sought-after technology attributes that can inform pertinent design criteria for electric water heating research, development, and deployment efforts. Among economics and energy efficiency features, interviewees overwhelmingly alluded to space constraints, cold air exhaust, and lack of clear guidance regarding distributed versus centralized design selections as key challenges associated with mass adoption of electric water heating. Owners and developers seek systems with minimal footprint, which maximize rentable space and profits. Moreover, distributed heat pump solutions should balance ducting costs that mitigate cold exhaust entrainment into conditioned zones. Lastly, the market needs clear guidance regarding the selection of distributed versus central electric hot water systems.

challenges of water heating electrification↗

Process intensification approach to enhancing heat and mass transfer during drying: Ultrasonic (US) assisted drying of paper and board

Drying of paper and board is conventionally achieved through alternating conduction (steam-heated cylinders) and pocket convection (heated air over the paper web surface). These conventional drying systems rely heavily on steam from fossil fuels, resulting in inefficiencies, high energy usage, and thermal losses due to surface-driven mechanisms. Here, to address these challenges, an experimental system, with in-situ drying characteristics measurements, was developed to investigate process intensification using ultrasonic-based dewatering—a volumetric, pressure-driven acoustic energy system—integrated with conventional drying. The objectives of this study are to assess the impact of ultrasonics (US) on dewatering; compare performances to conventional drying systems; identify improvements in drying rate and energy use as a function of moisture content; and gain potential insights on heat and mass transfer mechanisms during US-assisted drying. US performance was evaluated across frequencies, power levels, pulp types, and basis weights. Results show that improvements to ultrasonic applications in conjunction with convection were 30-43% in drying rate and 20-35% in drying time over continuous and intermittent applications. When combined with conduction and convection, ultrasonics yielded up to 20% improvement in both rate and time and up to 20% reduction in energy consumption. Observations support a hypothesis of extension of the constant rate period due to improved capillary flow at higher moisture content and enhancing vapor diffusion and boundary layer disruption at lower moisture contents during falling rate period. These findings will inform future modeling, simulation, design and optimization of advanced drying systems.

42 ENGINEERING↗

Inferring and evaluating satellite-based constraints on NO x emissions estimates in air quality simulations

Satellite observations of tropospheric NO 2 columns can provide top-down observational constraints on emissions estimates of nitrogen oxides (NO x ). Mass-balance-based methods are often applied for this purpose but do not isolate near-surface emissions from those aloft, such as lightning emissions. Here, we introduce an inverse modeling framework that couples satellite chemical data assimilation to a chemical transport model. In the framework, satellite-constrained emissions totals are inferred using model simulations with and without data assimilation in the iterative finite-difference mass-balance method. The approach improves the finite-difference mass-balance inversion by isolating the near-surface emissions increment. We apply the framework to separately estimate lightning and anthropogenic NO x emissions over the Northern Hemisphere for 2019. Using overlapping observations from the Ozone Monitoring Instrument (OMI) and the Tropospheric Monitoring Instrument (TROPOMI), we compare separate NO x emissions inferences from these satellite instruments, as well as the impacts of emissions changes on modeled NO 2 and O 3 . OMI inferences of anthropogenic emissions consistently lead to larger emissions than TROPOMI inferences, attributed to a low bias in TROPOMI NO 2 retrievals. Updated lightning NO x emissions from either satellite improve the chemical transport model's low tropospheric O 3 bias. The combined lighting and anthropogenic emissions updates improve the model's ability to reproduce measured ozone by adjusting natural, long-range, and local pollution contributions. Thus, the framework informs and supports the design of domestic and international control strategies.

54 ENVIRONMENTAL SCIENCES↗