Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same amount of data being used in the reconstruction process. Conclusions: The concept of assessing temporal resolution by means of the data employed for reconstruction can nicely be extended from single-source to dual-source CT. However, for advanced (possibly nonlinear iterative) reconstruction algorithms the examined approach fails to deliver accurate results. New methods and measures to assess the temporal resolution of CT images need to be developed to be able to accurately compare the performance of such algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Dark Energy Survey Data Management System

The Dark Energy Survey (DES) is a project with the goal of building, installing and exploiting a new 74 CCD-camera at the Blanco telescope, in order to study the nature of cosmic acceleration. It will cover 5000 square degrees of the southern hemisphere sky and will record the positions and shapes of 300 million galaxies up to redshift 1.4. The survey will be completed using 525 nights during a 5-year period starting in 2012. About O(1 TB) of raw data will be produced every night, including science and calibration images. The DES data management system has been designed for the processing, calibration and archiving of these data. It is being developed by collaborating DES institutions, led by NCSA. In this contribution, we describe the basic functions of the system, what kind of scientific codes are involved and how the Data Challenge process works, to improve simultaneously the Data Management system algorithms and the Science Working Group analysis codes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the Modulation Transfer Function of Surface Profilometers with Binary Pseudorandom Test Standards: Expanding the Application Range to Fizeau Interferometers and Electron Microscopes

A modulation transfer function (MTF) calibration method based on binary pseudorandom (BPR) gratings and arrays has been proven to be an effective MTF calibration method for interferometric microscopes and a scatterometer. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 in. phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to the BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Safeguards Technique for Spent Fuel Verification in Dry Storage by Using He-4 Detectors - 18262

It is demanded to find key issues and critical paths for verifying and monitoring a spent nuclear fuel cask or storage with a purpose of non-proliferation of nuclear weapon. However, unfortunately there are no reliable methods to verify the containment in a spent nuclear fuel cask or storage. Therefore, research and development (R and D) has been continuously required to develop new and alternative technologies for searching and verifying undeclared nuclear materials, activities, and facilities. Therefore, the present authors have developed a new safeguards technique of passively scanning a spent fuel cask or storage using pressurized He-4 scintillation neutron detectors. A new approach is to quickly verify content in a spent nuclear fuel cask or presence of all special nuclear materials in unknown packages by comparing experimental and computational results. For that, the present authors have developed a new algorithm and user-interface coupled ORIGEN-ARP and MCNP codes, and the prototype safeguards apparatus employing the array of He-4 fast neutron detectors has been designed, built, and tested. The feasibility test of this new apparatus has been performed with Cf-252 neutron sources and the laboratory scale model cask, minimized by a factor of ten compared to the actual dimension of a KN-21 cask. This technique has several advantages over current methods based on neutron and gamma detection; (1) incident neutron energy information is preserved, (2) disturbance of gamma-ray is excellently rejected (discriminated), and (3) much higher neutron counts and operational cost and space-effectiveness are expected since no moderator is required for fast neutrons. The final goal of this study will (1) conduct a prototype instrument and employ it to monitor a nuclear spent fuel cask or storage at a commercial nuclear power reactor facilities, (2) use spectral-specific measurement data to show proof of concept for measurable data successfully converted to quantifiable signatures, such as diversion/removal of fuel, and maintenance of fuel and cask integrity of fuel, and (3) develop a cask imaging capability. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Data acquisition and slow control interface for the Mu2e experiment

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10000 over existing limits. The Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, filtering, and processing. otsdaq is an online DAQ software suite with a focus on flexibility and scalability and provides a multi-user, web-based, interface accessible through a web browser. The data stream from the detector subsystems is read by a software filter algorithm that selects events which are combined with the data flux coming from a cosmic ray veto system. The Detector Control System (DCS) has been developed using the Experimental Physics and Industrial Control System (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS system has been integrated into otsdaq. A prototype of the TDAQ and the DCS systems has been built at Fermilab's Feynman Computing Center. In this study, we report on the progress of the integration of this prototype in the online otsdaq software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphysics for nuclear energy applications using a cohesive computational framework

With the recent development of advanced numerical algorithms, software design, and low-cost high-performance computer hardware, reliance on coupled multiphysics to predict the behavior of complex physical systems is beginning to become standard practice. This is especially true in nuclear energy applications where strong nonlinear interdependencies exist between reactor physics, radiation transport, multi-scale nuclear fuels performance, thermal fluids, etc. Resolving these nonlinear dependencies requires choices in multiphysics software approaches. Two main multiphysics modeling and simulation approaches have emerged. The first is based upon "code coupling" where disparate physics codes of different software design, code languages, and spatial and temporal integration schemes are coupled together with relatively complex data passing interfaces. The second multiphysics software approach is to employ a "cohesive" framework where all physics applications are developed with a common software design, i.e., data structures, syntax, input format, integrated spatial and temporal discretization schemes, etc. In this paper we present the Multiphysics Object-Oriented Simulation Environment (MOOSE) development and runtime framework and describe the framework's cohesive modeling and simulation multiphysics approach. Then, a "cohesive-like" extension of the MOOSE framework is presented where MOOSE-based physics software applications are efficiently coupled to non-MOOSE (external) physics codes to form multiphysics applications using MOOSE's unique interface capabilities. Finally, several examples of MOOSE's cohesive and cohesive-like multiphysics applications will be demonstrated. These multiphysics demonstrations will incorporate both MOOSE-based applications and external codes, including Nek5000, RELAP-7, TRACE, BISON, and Pronghorn.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NEW DIRECTIONS IN RADIOISOTOPE SPECTRUM IDENTIFICATION

Recent studies have found the performance of commercial handheld detectors with automatic RIID software to be less than acceptable. Previously, we have explored approaches rooted in speech processing such as cepstral features and information-theoretic measures. Scientific advances are often made when researchers identify mathematical or physical commonalities between different fields and are able to apply mature techniques or algorithms developed in one field to another field which shares some of the same challenges. The authors of this paper have identified similarities between the unsolved problems faced in gamma-spectroscopy for automated radioisotope identification and the challenges of the much larger body of research in speech processing. Our research has led to a probabilistic framework for describing and solving radioisotope identification problems. Many heuristic approaches to classification in current use, including for radioisotope classification, make implicit probabilistic assumptions which are not clear to the users and, if stated explicitly, might not be considered desirable. Our framework leads to a classification approach with demonstrable improvements using standard feature sets on proof-of-concept simulated and field-collected data.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Machine Learning Method for the Forensics Attribution of Separated Plutonium

Plutonium (Pu) source attribution would be a powerful tool to support nuclear nonproliferation efforts. This capability to find the source of a Pu sample would act as a deterrent to smuggling efforts, and also help regulatory agencies verify declared nuclear activities. Work at Texas A&M University yielded a nuclear forensics methodology, which is capable of determining separated Pu’s reactor of origin, fuel burnup, and the time since irradiation (TSI)—three parameters of interest. The methodology used a set of ten intra-element isotopic ratios found in separated Pu, which was compared to a library of isotopic ratio values produced using neutronics simulations for reactors of interest. By calculating the probability that unknown Pu sample’s isotopic ratio set matched a set in the library, the methodology could predict the three parameters of interest of the sample. One shortcoming of this methodology was an inability to correctly attribute spoofed Pu, where Pu sourced from two different reactors or two different fuel burnup levels are mixed. A new methodology to rectify this vulnerability using machine learning (ML) technique is developed, instead of the maximum likelihood calculation previously used and the results are satisfactory. The ML approach leverages the existing simulated data for training the algorithm, but use them efficiently by only using intra-element isotope ratios that contribute to the attribution one of the three parameters at a time. Previously, all isotope ratios were used to attribute all three parameters together. The new methodology attributes the Pu parameters in three steps, one for each parameter, rather than resolving all of the three parameters simultaneously like the previous maximum likelihood approach. First, a support vector machine classifier with a set of seven isotopic ratios finds the reactor of origin and a set of regression models trained using gaussian process predicts the burnup with a different set of seven isotopes. Finally, TSI is calculated analytically using decay equations. Thus far, the new methodology is capable of attributing pure Pu samples and has been validated using experimental data. The next step will to be augment the classifier training data set with spoofed Pu data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data-flow parallelism for high-energy and nuclear physics frameworks

The processing tasks of an event-processing workflow in high-energy and nuclear physics (HENP) can typically be represented as a directed acyclic graph formed according to the data flow—i.e. the data dependencies among algorithms executed as part of the workflow. With this representation, an HENP framework can optimally execute a workflow, exploiting the parallelism inherent among independent tasks. Despite such a natural description of a workflow, most HENP frameworks do not make use of technologies that provide concurrent execution of graph-based tasking structures. In this talk, we describe Fermilab efforts to adopt a graph-based technology (specifically Intel’s oneTBB flow graph) for meeting the framework needs of its experiments, notably DUNE. Building on the Meld project as presented at CHEP2023, we demonstrate that all common processing idioms supported by current frameworks can naturally be supported by oneTBB’s data-flow technology, optimally leveraging the concurrent capabilities of the machine. In addition, we discuss collaborative efforts between Fermilab and the Intel oneTBB development team, who is considering improvements to the flow-graph technology to better support HENP use cases.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps

In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Evaluation of an Intelligent Sensor Platform for Radiation Monitoring Applications

Accurate, rugged, and reliable radiation detection systems are important for area and environmental monitoring applications. The desire for spectroscopic capability has increased in monitoring aspects of the nuclear fuel cycle to provide fast characterization of the radiation profile of a situation, such as the planned or unplanned release of material. The reduction or elimination of having to conduct sampling for laboratory analysis can result in significant cost savings for an industry, government agency, or regulatory body. A new system, comprised of a NaI:Tl scintillator and a G-M tube, has been designed and tested, taking into account the following end-user requirements: ease-of-use, capability to network and supervise multiple units, compact form factor, low power consumption, versatility, and stability. The detector sizes were selected to accommodate a dose rate up to 1 Sv/hr. Several algorithms and analysis routines have been developed to incorporate these key needs without sacrificing on accuracy, dynamic range, nuclide identification, and sensitivity. This presentation will introduce the major hardware and software components of the platform, as well as the user interface and data analysis workflow. Key features of the hardware include an environmentally robust housing, low power signal processing electronics, patented LED-based gain stabilization, and an embedded processor for unattended instrument management and data analysis. New and improved algorithms for determining scintillator gamma dose rates, total integrated dose, and nuclide identification will be introduced. The two detector elements were modeled with MCNP and validated experimentally. The results of the radiological testing shall be presented including energy resolution, throughput, dose response, and minimum detectable activities. The dose response has been evaluated in simulations and with measurements to ensure accurate response with respect to energy spectrum of the dose field and direction of the incident radiation. Spectroscopy evaluations, such as nuclide detection probability and false alarm rates, were performed and comparisons to existing algorithms shall also be presented. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Étude et simulation de la lumière de scintillation produite et se propageant dans une chambre à dérive double-phase à argon liquide, dans le contexte du projet DUNE

DUNE is a future long-baseline neutrino experiment designed to determine, among others, the neutrino mass hierarchy and to measure the CP violation phase that enters the neutrino oscillation process. This project is based on a 1300 km long high intensity neutrino beam and a massive detector containing more than 40 kilotons of liquid argon using the liquid argon time projection chamber technology (LArTPC). Two approaches of this technology are currently under development, leading to the construction of two prototypes to be in place at the end of 2018 at CERN. The work of this thesis is part of the ProtoDUNE-DP project, which aims at probing the capabilities of the so-called “dual-phase” technology, that uses both gaseous and liquid argon, for a large-scale detector. Two kind of signals, a charge signal and a scintillation light signal, are expected in a LArTPC. The light signal can be used as a trigger, for the identification and rejection of the cosmic background, and for precise calorimetric measurements. Prior simulations of this signal are needed in order to improve our understanding of the scintillation light signal and to develop the identification algorithms. This work addresses the development of this simulation and the study of the scintillation photon behavior in the liquid argon detector. The different scintillation light production mechanisms, the developed simulation and the different studies on the light propagation in ProtoDUNE-DP are presented. These simulations have also been compared with light data taken at CERN in 2017 with a first demonstrator, in order to validate and tune the simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distances to Prompt Effects for a Nuclear Device

In 2010, nuclear weapon effects experts at Sandia National Laboratories (SNL) were asked to provide a quick reference document containing estimated prompt nuclear effects. This report is an update to the 2010 document that includes updated model assumptions. This report addresses only the prompt effects associated with a nuclear detonation (e.g., blast, thermal fluence, and prompt ionizing radiation). The potential medium- and longer-term health effects associated with nuclear fallout are not considered in this report because, in part, of the impracticality of making generic estimates given the high dependency of fallout predictions on the local meteorological conditions at the time of the event. The results included in this report also do not consider the urban environment (e.g., shielding by or collapse of structures) which may affect the extent of prompt effects. It is important to note that any operational recommendations made using the estimates in this report are limited by the generic assumptions considered in the analysis and should not replace analyses made for a specific scenario/device. Furthermore, nuclear effects experts (John Hogan, SNL, and Byron Ristvet, Defense Threat Reduction Agency (DTRA)) have indicated that the accuracy of effects predictions below 0.5 kilotons (kT) or 500 tons nuclear yield have greater uncertainty because of the limited data available for the prompt effects in this regime. The Specialized Hazard Assessment Response Capability (SHARC) effects prediction tool was used for these analyses. Specifically, the NUKE model within SHARC 2021 Version 10.2 was used. NUKE models only the prompt effects following a nuclear detonation. The algorithms for predicting range-to-output data contained within the NUKE model are primarily based on nuclear test effects data. Probits have been derived from nuclear test data and the U.S. Environmental Protection Agency (EPA) protective action guides. Probits relate the probability of a hazard (e.g., fatality or injury) caused by a given insult (e.g., overpressure, thermal fluence, dose level). Several probits have been built into SHARC to determine the fatality and injury associated with a given level of insult. Some of these probits differ with varying yield. Such probits were used to develop the tables and plots in this report.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

42 ENGINEERING↗

Anniversary Paper: History and status of CAD and quantitative image analysis: The role of Medical Physics and AAPM

The roles of physicists in medical imaging have expanded over the years, from the study of imaging systems (sources and detectors) and dose to the assessment of image quality and perception, the development of image processing techniques, and the development of image analysis methods to assist in detection and diagnosis. The latter is a natural extension of medical physicists' goals in developing imaging techniques to help physicians acquire diagnostic information and improve clinical decisions. Studies indicate that radiologists do not detect all abnormalities on images that are visible on retrospective review, and they do not always correctly characterize abnormalities that are found. Since the 1950s, the potential use of computers had been considered for analysis of radiographic abnormalities. In the mid-1980s, however, medical physicists and radiologists began major research efforts for computer-aided detection or computer-aided diagnosis (CAD), that is, using the computer output as an aid to radiologists--as opposed to a completely automatic computer interpretation--focusing initially on methods for the detection of lesions on chest radiographs and mammograms. Since then, extensive investigations of computerized image analysis for detection or diagnosis of abnormalities in a variety of 2D and 3D medical images have been conducted. The growth of CAD over the past 20 years has been tremendous--from the early days of time-consuming film digitization and CPU-intensive computations on a limited number of cases to its current status in which developed CAD approaches are evaluated rigorously on large clinically relevant databases. CAD research by medical physicists includes many aspects--collecting relevant normal and pathological cases; developing computer algorithms appropriate for the medical interpretation task including those for segmentation, feature extraction, and classifier design; developing methodology for assessing CAD performance; validating the algorithms using appropriate cases to measure performance and robustness; conducting observer studies with which to evaluate radiologists in the diagnostic task without and with the use of the computer aid; and ultimately assessing performance with a clinical trial. Medical physicists also have an important role in quantitative imaging, by validating the quantitative integrity of scanners and developing imaging techniques, and image analysis tools that extract quantitative data in a more accurate and automated fashion. As imaging systems become more complex and the need for better quantitative information from images grows, the future includes the combined research efforts from physicists working in CAD with those working on quantitative imaging systems to readily yield information on morphology, function, molecular structure, and more--from animal imaging research to clinical patient care. A historical review of CAD and a discussion of challenges for the future are presented here, along with the extension to quantitative image analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Data Processing for Hyperspectral Sensors on Small Platforms

Hyperspectral imaging is a very promising technology for nuclear proliferation detection. However, due to size and weight restrictions, small hyperspectral platforms such as satellites and small drones lack the on-board computing resources for accurate, real-time analysis of the enormous flow of data that a continuously operating hyperspectral sensor generates. This severely limits satellite systems, which can collect far more data than what they can telemeter, and hinders the ability of all platforms to adapt their missions on the fly in response to observations. This program addresses the hyperspectral data processing challenge through development of new, fast and accurate algorithms that produce data products in real time. The algorithms circumvent the major computational bottlenecks in existing processing streams, and would be incorporated in lightweight, power-efficient single-board computer systems. The toolkit of fast algorithms will be immediately useful in current and future hyperspectral systems being built by the Government and by private industry, including drone-based systems and satellite constellations that acquire timely global imagery.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analysis of dynamic radiation level changes using surface networks [Book Chapter]

The Fukushima nuclear accident reminds us of severe risk of radioactive substances. Citizen scientists voluntarily collect and share radiation data using geo-tagged sensors for radiation preparedness. However, radiation levels are affected by a number of factors including for example weather conditions, naturally occurring radioactive materials (NORM), and large marble structures. It is therefore difficult to determine whether a higher radiation level comes from a normal variation in background or not. This research analyzes the radiation changes using surface networks that can be used to characterize complex surfaces. A new algorithm has been developed to identify salient peaks and their hills by merging insignificant peaks recur-sively. Salient peaks and their hills are converted into graphs. The structural similarities of graphs were compared over time. The radiation measurements in the city of Koriyama, Japan were analyzed as a case study. The results demonstrated that structural analysis of dynamic radiation levels revealed stable changes, while numeric analysis of radiation levels presented statistically significant differences. This method is able to detect radiation level changes irrespective of background variations.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-167: Measurement of Proton Beam Spot Size Using a 2D Ion Chamber Array for Daily QA

Purpose: To develop an algorithm which can calculate the Full Width Half Maximum (FWHM) of a Proton Pencil Beam from a 2D dimensional ion chamber array (IBA Matrixx) with limited spatial resolution ( 7.6 mm inter chamber distance). The algorithm would allow beam FWHM measurements to be taken during daily QA without an appreciable time increase. Methods: Combinations of 147 MeV single spot beams were delivered onto an IBA Matrixx and concurrently on EBT3 films for a standard. Data were collected around the Bragg Peak region and evaluated by a custom MATLAB script based on our algorithm using a least squared analysis. A set of artificial data, modified with random noise, was also processed to test for robustness. Results: The Matlab script processed Matixx data shows acceptable agreement (within 5%) with film measurements with no single measurement differing by more than 1.8 mm. In cases where the spots show some degree of asymmetry, the algorithm is able to resolve the differences. The algorithm was able to process artificial data with noise up to 15% of the maximum value. Time assays of each measurement took less than 3 minutes to perform, indicating that such measurements may be efficiently added to daily QA treatment. Conclusion: The developed algorithm can be implemented in daily QA program for Proton Pencil Beam scanning beams (PBS) with Matrixx to extract spot size and position information. The developed algorithm may be extended to small field sizes in photon clinic.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗