Benchmarking a new closed-form thermal analysis technique against a traditional lumped parameter, finite-difference method
A benchmarking effort was conducted to determine the accuracy of a new analytic generic geology thermal repository model developed at LLNL relative to a more traditional, numerical, lumped parameter technique. The fast-running analytical thermal transport model assumes uniform thermal properties throughout a homogenous storage medium. Arrays of time-dependent heat sources are included geometrically as arrays of line segments and points. The solver uses a source-based linear superposition of closed form analytical functions from each contributing point or line to arrive at an estimate of the thermal evolution of a generic geologic repository. Temperature rise throughout the storage medium is computed as a linear superposition of temperature rises. It is modeled using the MathCAD mathematical engine and is parameterized to allow myriad gridded repository geometries and geologic characteristics [4]. It was anticipated that the accuracy and utility of the temperature field calculated with the LLNL analytical model would provide an accurate 'birds-eye' view in regions that are many tunnel radii away from actual storage units; i.e., at distances where tunnels and individual storage units could realistically be approximated as physical lines or points. However, geometrically explicit storage units, waste packages, tunnel walls and close-in rock are not included in the MathCAD model.