Search NASA⌕ Search

SEARCH · Search NASA

Results for “Atomic Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

High-resolution studies of the Majorana atomic chain platform

Ordered assemblies of magnetic atoms on the surface of conventional superconductors can be used to engineer topological superconducting phases and realize Majorana fermion quasiparticles (MQPs) in a condensed matter setting. Recent experiments have shown that chains of Fe atoms on Pb generically have the required electronic characteristics to form a one-dimensional topological superconductor and have revealed spatially resolved signatures of localized MQPs at the ends of such chains. Here we report higher-resolution measurements of the same atomic chain system performed using a dilution refrigerator scanning tunnelling microscope (STM). With significantly better energy resolution than previous studies, we show that the zero-bias peak (ZBP) in Fe chains has no detectable splitting from hybridization with other states. The measurements also reveal that the ZBP exhibits a distinctive ‘double eye’ spatial pattern on nanometre length scales. Theoretically we show that this is a general consequence of STM measurements of MQPs with substantial spectral weight in the superconducting substrate, a conclusion further supported by measurements of Pb overlayers deposited on top of the Fe chains. Lastly, we report experiments performed with superconducting tips in search of the particle–hole symmetric MQP signature expected in such measurements.

Electronic properties and materials↗

Automatic software correction of residual aberrations in reconstructed HRTEM exit waves of crystalline samples

Abstract We develop an automatic and objective method to measure and correct residual aberrations in atomic-resolution HRTEM complex exit waves for crystalline samples aligned along a low-index zone axis. Our method uses the approximate rotational point symmetry of a column of atoms or single atom to iteratively calculate a best-fit numerical phase plate for this symmetry condition, and does not require information about the sample thickness or precise structure. We apply our method to two experimental focal series reconstructions, imaging a β-Si 3 N 4 wedge with O and N doping, and a single-layer graphene grain boundary. We use peak and lattice fitting to evaluate the precision of the corrected exit waves. We also apply our method to the exit wave of a Si wedge retrieved by off-axis electron holography. In all cases, the software correction of the residual aberration function improves the accuracy of the measured exit waves.

36 MATERIALS SCIENCE↗

Cd doping at PVD-CdS/CuInGaSe 2 heterojunctions

In this paper, we report on direct evidence of Cd doping of the CuInGaSe 2 (CIGS) surface in physical vapor deposited (PVD) CdS/CIGS heterojunctions by scanning transmission electron microscopy (STEM) and related techniques. We find Cd doping of the CIGS near-surface region regardless of the presence or absence of Cu rich domains in the CdS for both zinc-blende (zb) and wurtzite (wz) CdS. However, we find that the Cd penetrates much farther into the CIGS when Cu-rich domains are present in the CdS. This suggests that Cu exchanges with Cd, increasing the concentration gradient for Cd in the CIGS and thus driving Cd into the CIGS surface. The Cd doping is clearly resolved at atomic resolution in aberration-corrected STEM-high angle annular dark field images. In zb-CdS/CIGS heterojunctions, Cd is shown to substitute for both Cu and Ga atoms, while in wz-CdS/CIGS heterojunctions Cd seems to predominantly occupy Cu sites. Finally, Cd doping in the CIGS surface layer suggests the formation of a p-n homojunction in the CIGS, which may account for the high device efficiencies, comparable to CBD-CdS/CIGS processed structures.

14 SOLAR ENERGY↗

Dose-dependent high-resolution electron ptychography

Recent reports of electron ptychography at atomic resolution have ushered in a new era of coherent diffractive imaging in the context of electron microscopy. We report and discuss electron ptychography under variable electron dose conditions, exploring the prospects of an approach which has considerable potential for imaging where low dose is needed.

60 APPLIED LIFE SCIENCES↗

End station for nanoscale magnetic materials study: Combination of scanning tunneling microscopy and soft X-ray magnetic circular dichroism spectroscopy

We have constructed an end station for nanoscale magnetic materials study at the soft X-ray beamline HiSOR BL-14 at Hiroshima Synchrotron Radiation Center. An ultrahigh-vacuum scanning tunneling microscope (STM) was installed for an in situ characterization of nanoscale magnetic materials in combination with soft X-ray magnetic circular dichroism (XMCD) spectroscopy experiment. The STM was connected to the XMCD experimental station via damper bellows to isolate it from environmental vibrations, thus achieving efficient spatial resolution for observing Si(111) surface at atomic resolution. We performed an in situ experiment with STM and XMCD spectroscopy on Co nanoclusters on an Au(111) surface and explored its practical application to investigate magnetic properties for well-characterized nanoscale magnetic materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultra-high resolution electron microscopy

The last two decades have seen dramatic advances in the resolution of the electron microscope brought about by the successful correction of lens aberrations that previously limited resolution for most of its history. Here we briefly review these advances, the achievement of sub-Ångstrom resolution and the ability to identify individual atoms, their bonding configurations and even their dynamics and diffusion pathways. We then present a review of the basic physics of electron scattering, lens aberrations and their correction, and an approximate imaging theory for thin crystals which provides physical insight into the various different imaging modes. Then we proceed to describe a more exact imaging theory starting from Yoshioka’s formulation and covering full image simulation methods using Bloch waves, the multislice formulation and the frozen phonon/quantum excitation of phonons models. Delocalization of inelastic scattering has become an important limiting factor at atomic resolution. We therefore discuss this issue extensively, showing how the full-width-half-maximum is the appropriate measure for predicting image contrast, but the diameter containing 50% of the excitation is an important measure of the range of the interaction. These two measures can differ by a factor of 5, are not a simple function of binding energy, and full image simulations are required to match to experiment. The Z-dependence of annular dark field images is also discussed extensively, both for single atoms and for crystals, and we show that temporal incoherence must be included accurately if atomic species are to be identified through matching experimental intensities to simulations. Finally we mention a few promising directions for future investigation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence of Xe-incorporation in the bubble superlattice in irradiated U-Mo fuel

For years, researchers have reported competing ideas on the formation of fission gas bubble super lattices in metallic fuels, which was postulated to be comprised of elemental xenon (Xe) atoms. However, the chemical and physical arrangement of these elements within this gas bubble superlattice has not been verified. In this contribution, Xe was chemically profiled using atomic resolution scanning transmission electron microscopy (STEM) and atom probe tomography (APT) techniques in irradiated uranium-molybdenum (U-Mo) fuels. These complementary techniques provide conclusive evidence of Xe presence in bubble superlattice up to fission densities of 4.5×10 21 fissions/cm 3 and provide quantitative assessment of Xe content within the bubble superlattice. Based on the results of simultaneous imaging and spectroscopy using STEM, the chemical composition of the Xe bubble superlattice present in fission densities less than 4.5x10 21 fissions/cm 3 in U-Mo fuel was measured and found to be up to 8±1.3 atomic %. APT data complements STEM findings on Xe distribution in irradiated U-Mo fuel sample. APT showed a chemical composition of 0.7±0.1 atomic%. Finally, this study concludes by providing conclusive evidence that Xe is not only present within an atomically arranged bubble superlattice but provides fundamental insight the physical state of Xe in low enriched U-Mo monolithic fuel.

36 MATERIALS SCIENCE↗

Direct growth of crystalline SiGe nanowires on superconducting NbTiN thin films

Novel heterostructures created by coupling one-dimensional semiconductor nanowires with a superconducting thin film show great potential toward next-generation quantum computing. Here, by growing high-crystalline SiGe nanowires on a NbTiN thin film, the resulting heterostructure exhibits Ohmic characteristics as well as a shift of the superconducting transition temperature (T c ). The structure was characterized at atomic resolution showing a sharp SiGe/NbTiN interface without atomic interdiffusion. Lattice spacing, as calculated from large-area x-ray diffraction experiments, suggests a potential preferred d-spacing matching between (200) NbTiN and (110) SiGe grains. The observed out-of-plane compressive strain within the NbTiN films coupled with SiGe nanowires explains the downward shift of the superconductivity behavior. The presented results post scientific insights toward functional heterostructures by coupling multi-dimensional materials, which could enable tunable superconductivity that benefits the quantum science applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Atomically precise digital e-beam lithography

Hydrogen Depassivation Lithography (HDL) is a version of electron beam lithography that uses scanning tunneling microscope (STM) instrumentation to expose a self–developing resist that is a monolayer of H chemisorbed to a Si (100) 2x1 H-passivated surface. Developed in the 1990s it has been largely a laboratory tool used in research for nanofabrication. Here, the technique is capable of atomic resolution, the ability to remove single H atoms from the Si surface and has much higher precision than the best conventional e-beam lithography can possibly achieve exposing polymeric resists. However, its most promising attribute is that it can be used as a digital fabrication tool and is the first of a class of nanofabrication techniques that can be considered digital atomic scale fabrication technologies. Digital Atomic Scale Fabrication can be shown to have similar advantages over analog fabrication techniques that digital information technology has over analog information technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An improved crystal structure of C-phycoerythrin from the marine cyanobacterium Phormidium sp. A09DM

C-Phycoerythrin (PE) from Phormidium sp. A09DM has been crystallized using different conditions and its structure determined to atomic resolution (1.14 Å). In order for the pigment present, phycoerythrobilin (PEB), to function as an efficient light-harvesting molecule it must be held rigidly (Kupka and Scheer in Biochim Biophys Acta 1777:94–103, 2008) and, moreover, the different PEB molecules in PE must be arranged, relative to each other, so as to promote efficient energy transfer between them. This improved structure has allowed us to define in great detail the structure of the PEBs and their binding sites. These precise structural details will facilitate theoretical calculations of each PEB’s spectroscopic properties. It was possible, however, to suggest a model for which chromophores contribute to the different regions of absorption spectrum and propose a tentative scheme for energy transfer. We show that some subtle differences in one of these PEB binding sites in two of the 12 subunits are caused by crystal contacts between neighboring hexamers in the crystal lattice. This explains some of the differences seen in previous lower resolution structures determined at two different pH values (Kumar et al. in Photosyn Res 129:17–28, 2016).

59 BASIC BIOLOGICAL SCIENCES↗

Cryogenic X-ray crystallographic studies of biomacromolecules at Turkish Light Source " Turkish DeLight "

X-ray crystallography is a robust and powerful structural biology technique that provides high-resolution atomic structures of biomacromolecules. Scientists use this technique to unravel mechanistic and structural details of biological macromolecules (e.g., proteins, nucleic acids, protein complexes, protein-nucleic acid complexes, or large biological compartments). Since its inception, single-crystal cryocrystallography has never been performed in Türkiye due to the lack of a single-crystal X-ray diffractometer. The X-ray diffraction facility recently established at the University of Health Sciences, Istanbul, Türkiye will enable Turkish and international researchers to easily perform high-resolution structural analysis of biomacromolecules from single crystals. Here, we describe the technical and practical outlook of a state-of-the-art home-source X-ray, using lysozyme as a model protein. The methods and practice described in this article can be applied to any biological sample for structural studies. Therefore, this article will be a valuable practical guide from sample preparation to data analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Ultra-Microtome for the Preparation of TEM Samples from Battery Cathodes

An ultra-microtome method is developed for the preparation of transmission electron microscopy (TEM) specimens from the cathodes of Li-ion battery. Results indicate that the samples prepared with the ultra-microtome method yield atomic resolution imaging from the core area of particles of hundreds to thousands of nanometers. Analysis of the TEM samples prepared with ultra-microtome indicates that no observable structural damage, such as microcracking, is introduced during the cutting process, and the cathodes cut by ultra-microtome exhibit unchanged micro-morphologies compared with the uncut ones. These results demonstrate that ultra-microtome is a promising method for the preparation of TEM specimens and revealing in-depth microstructures of fragile materials such as battery cathodes.

transmission electron microscopy, Sample Preparati↗

Atomic-Scale Imaging and Spectroscopy for In Situ Liquid Scanning Transmission Electron Microscopy

Observation of growth, synthesis, dynamics and electrochemical reactions in the liquid state is an important yet largely unstudied aspect of nanotechnology. The only techniques that can potentially provide the insights necessary to advance our understanding of these mechanisms is simultaneous atomic-scale imaging and quantitative chemical analysis (through spectroscopy) under environmental conditions in the transmission electron microscope (TEM). In this study we describe the experimental and technical conditions necessary to obtain electron energy loss (EEL) spectra from a nanoparticle in colloidal suspension using aberration corrected scanning transmission electron microscopy (STEM) combined with the environmental liquid stage. At a fluid path length below 400 nm, atomic resolution images can be obtained and simultaneous compositional analysis can be achieved. We show that EEL spectroscopy can be used to quantify the total fluid path length around the nanoparticle, and demonstrate characteristic core-loss signals from the suspended nanoparticles can be resolved and analyzed to provide information on the local interfacial chemistry with the surrounding environment. The combined approach using aberration corrected STEM and EEL spectra with the in situ fluid stage demonstrates a plenary platform for detailed investigations of solution based catalysis and biological research.

atomic resolution↗

Image registration of low signal-to-noise cryo-STEM data

Combining multiple fast image acquisitions to mitigate scan noise and drift artifacts has proven essential for picometer precision, quantitative analysis of atomic resolution scanning transmission electron microscopy (STEM) data. For very low signal-to-noise ratio (SNR) image stacks – frequently required for undistorted imaging at liq- uid nitrogen temperatures – image registration is particularly delicate, and standard approaches may either fail, or produce subtly specious reconstructed lattice images. We present an approach which effectively registers and averages image stacks which are challenging due to their low-SNR and propensity for unit cell misalignments. Registering all possible image pairs in a multi-image stack leads to significant information surplus. In combination with a simple physical picture of stage drift, this enables identi cation of incorrect image registrations, and determination of the optimal image shifts from the complete set of relative shifts. Here, we demonstrate the effectiveness of our approach on experimental, cryogenic STEM datasets, highlighting subtle artifacts endemic to low-SNR lattice images and how they can be avoided. High-SNR average images with information transfer out to 0.72 Å are achieved at 300 kV and with the sample cooled to near liquid nitrogen temperature.

47 OTHER INSTRUMENTATION↗

Application of atomic layer deposited microchannel plates to imaging photodetectors with high time resolution

Novel microchannel plates have been constructed using borosilicate glass micro-capillary array substrates with 20 mu m and 10 mu m pores and coated with resistive, and secondary electron emissive, layers by atomic layer deposition. Microchannel plates in 33 mm, 50 mm and 20 cm square formats have been made and tested. Although their amplification, imaging, and timing properties are comparable to standard glass microchannel plates, the background rates and lifetime characteristics are considerably improved. Sealed tube detectors based on the Planacon tube, and a 25 mm cross delay line readout tube with a GaN(Mg) opaque photocathode deposited on borosilicate microchannel plates have been fabricated. Considerable progress has also been made with 20 cm microchannel plates for a 20 cm format sealed tube sensor with strip-line readout that is being developed for Cherenkov light detection.

Siegmund, O. H. W.↗

Electron transfer and ionic displacements as the origin of the 2D electron gas at the LAO/STO interface: Direct measurements with atomic-column spatial resolution.

We present direct, atomic-column-resolved scanning transmission electron microscopy and electron energy loss measurements of atomic displacements and Ti valence in abrupt, conductive LAO/STO interfaces. We find that two distinct but interrelated mechanisms are responsible for screening the diverging electric potential in the LAO film: 1) charge injection in the interfacial Ti planes, and 2) dielectric relaxation in both LAO and STO through ionic displacements. The injected charge density decays over a length of nearly 3 unit cells within the STO substrate. The total injected charge is lower than predicted by pure electronic reconstruction. The origin of this discrepancy is attributed to cation and oxygen displacements, which we observe in both LAO and STO, and generate a polarization opposite to the intrinsic polarization of the LAO film. Our data attribute a minor role to oxygen vacancies and cation intermixing.

36 MATERIALS SCIENCE↗

Structural and spectroscopic characterization of photoactive yellow protein and photoswitchable fluorescent protein constructs containing heavy atoms

Photo-induced structural rearrangements of chromophore-containing proteins are essential for various light-dependent signaling pathways and optogenetic applications. Ultrafast structural and spectroscopic methods have offered insights into these structural rearrangements across many timescales. However, questions still remain about exact mechanistic details, especially regarding photoisomerization of the chromophore within these proteins femtoseconds to picoseconds after photoexcitation. Instrumentation advancements for time-resolved crystallography and ultrafast electron diffraction provide a promising opportunity to study these reactions, but achieving enough signal-to-noise is a constant challenge. In this work, we present four new photoactive yellow protein constructs and one new fluorescent protein construct that contain heavy atoms either within or around the chromophore and can be expressed with high yields. Structural characterization of these constructs, most at atomic resolution, show minimal perturbation caused by the heavy atoms compared to wild-type structures. Spectroscopic studies report the effects of the heavy atom identity and location on the chromophore’s photophysical properties. None of the substitutions prevent photoisomerization, although certain rates within the photocycle may be affected. Overall, these new proteins containing heavy atoms are ideal samples for state-of-the-art time-resolved crystallography and electron diffraction experiments to elucidate crucial mechanistic information of photoisomerization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗