Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Comparison of Measurement And Modeling Of Current Profile Changes Due To Neutral Bean Ion Redistribution During TAE Avalanches in NSTX

Brief "avalanches" of toroidal Alfven eigenmodes (TAEs) are observed in NSTX plasmas with several different n numbers simultaneously present. These affect the neutral beam ion distribution as evidenced by a concurrent drop in the neutron rate and, sometimes, beam ion loss. Guiding center orbit modeling has shown that the modes can transiently render portions of the beam ion phase space stochastic. The resulting redistribution of beam ions can also create a broader beam-driven current profile and produce other changes in the beam ion distribution function

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Parametric Channeling Radiation and its Application to the Measurement of Electron Beam Energy

We have proposed a method for observing parametric channeling radiation (PCR) and of applying it to the measurement of electron beam energy. The PCR process occurs if the energy of the channeling radiation coincides with the energy of the parametric X-ray radiation (PXR). The PCR process can be regarded as the diffraction of 'virtual channeling radiation'. We developed a scheme for beam energy measurement and designed an experimental setup. We also estimated the beam parameters, and calculated the angular distributions of PXR and PCR. These considerations indicate that the observation of PCR is promising.

43 PARTICLE ACCELERATORS↗

An experimental study of current-density distributions of a technological electron beam

An experimental technique for the acquisition of current-density distributions of continuously operating electron beams with an electron energy of 60 keV is proposed. The measurement results for different cross-sectional areas of the beam with a power of 2.1 kW and a current density around 1 × 10{sup 5} A/m{sup 2} are given.

43 PARTICLE ACCELERATORS↗

{alpha}-particle production in {sup 6}He+{sup 120}Sn collisions

The collision {sup 6}He+{sup 120}Sn has been investigated at four energies near the Coulomb barrier. A large yield of {alpha} particles has been detected, with energies around the energy of the scattered {sup 6}He beam. The energy and angular distributions of the {alpha} particles have been analyzed and compared with breakup and neutron transfer calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-dependent charge distributions in polymer films under electron beam irradiation

The time-dependent charge distribution in polymer film under electron beam irradiation is studied by both experiment and numerical simulation. In the experiment, the distribution is measured with the piezoinduced pressure wave propagation method. In the simulation, the initial charge distribution is obtained by the Monte Carlo method of electron scattering, and the charge drift in the specimen is simulated by taking into account the Poisson equation, the charge continuity equation, Ohm's law, and the radiation-induced conductivity. The results obtained show that the negative charge deposited in the polymer film, whose top and bottom surfaces are grounded, drifts toward both grounded electrodes and that twin peaks appear in the charge distribution. The radiation-induced conductivity plays an important role in determining the charge distribution in the polymer films under electron beam irradiation.

36 MATERIALS SCIENCE↗

The synchrotron-maser theory of type II solar radio emission processes - The physical model and generation mechanism

A theory is proposed to explain the generation mechanism of type II solar radio bursts. It is suggested that the shock wave formed at the leading edge of a coronal transient can accelerate electrons. Because of the nature of the acceleration process, the energized electrons can possess a 'hollow-beam' type distribution function. When the electron beam propagates along the ambient magnetic field to lower altitudes and attains larger pitch angles, a synchrotron-maser instability can set in. This instability leads to the amplification of unpolarized or weakly polarized radiation. The present discussion incorporates a model which describes the ambient magnetic field and background plasma by means of MHD simulation. The potential emission regions may be located approximately, according to the time-dependent MHD simulation. Since the average local plasma frequency in the source region can be evaluated from the MHD model, the frequent drift associated with the radiation may be estimated. The result seems to be in good agreement with that derived from observations.

Wu, C. S.↗

Conceptual Design of the Drive Beam for a PWFA-LC

Plasma Wake-Field Acceleration (PWFA) has demonstrated acceleration gradients above 50 GeV/m. Simulations have shown drive/witness bunch configurations that yield small energy spreads in the accelerated witness bunch and high energy transfer efficiency from the drive bunch to the witness bunch, ranging from 30% for a Gaussian drive bunch to 95% for bunch with triangular shaped longitudinal profile. These results open the opportunity for a linear collider that could be compact, efficient and more cost effective than the present microwave technologies. A concept of a PWFA-based Linear Collider (PWFA-LC) has been developed by the PWFA collaboration. Here we will describe the conceptual design and optimization of the drive beam, which includes the drive beam linac and distribution system. We apply experience of the CLIC drive beam design and demonstration in the CLIC Test Facility (CTF3) to this study. We discuss parameter optimization of the drive beam linac structure and evaluate the drive linac efficiency in terms of the drive beam distribution scheme and the klystron/modulator requirements.

43 PARTICLE ACCELERATORS↗

Resonator with a back deformable mirror for the formation of a beam with a given intensity distribution

We present the results of a numerical-analytical study of formation of an output beam with a given intensity distribution for a resonator with a back deformable mirror (DM) and semitransparent spherical front mirror. Using the theory of inverse optical problems in the diffraction approximation, the basic characteristics of a laser resonator with a DM are considered as functions of the reference resonator configuration and the form of the distribution function, describing the given intensity. The laser beam formation in the reference resonator with plane-parallel and concentric configurations is compared. In the investigated resonators, the given intensity distribution is a fundamental mode; the selectivity (determined by the power losses of transverse modes) of the resonator with a DM is comparable with that of the reference resonator. It is shown that the formation of the given intensity distributions (uniform, super-Gaussian, or having several maxima) requires a DM with the amplitude of deformations of the optical surface of the order of {lambda} and the number of control channels from 1 to nearly 10.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extracting source parameters from beam monitors on a chopper spectrometer

The intensity distributions of beam monitors in direct-geometry time-of-flight neutron spectrometers provide important information about the instrument resolution. For short-pulse spallation neutron sources in particular, the asymmetry of the source pulse may be extracted and compared to Monte Carlo source simulations. An explicit formula using a Gaussian-convolved Ikeda-Carpenter distribution is given and compared to data from the ARCS instrument at the Spallation Neutron Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of submillisecond response optical addressing phase modulator based on low light scattering polymer network liquid crystal

Optically addressed conventional nematic liquid crystal spatial light modulator has attracted wide research interests. But the slow response speed limited its further application. In this paper, polymer network liquid crystal (PNLC) was proposed to replace the conventional nematic liquid crystal to enhance the response time to the order of submillisecond. The maximum light scattering of the employed PNLC was suppressed to be less than 2% at 1.064 μm by optimizing polymerization conditions and selecting large viscosity liquid crystal as solvent. The occurrence of phase ripple phenomenon due to electron diffusion and drift in photoconductor was found to deteriorate the phase modulation effect of the optical addressed PNLC phase modulator. The wavelength effect and AC voltage frequency effect on the on state dynamic response of phase change was investigated by experimental methods. These effects were interpreted by electron diffusion and drift theory based on the assumption that free electron was inhomogeneously distributed in accordance with the writing beam intensity distribution along the incident direction. The experimental results indicated that the phase ripple could be suppressed by optimizing the wavelength of the writing beam and the driving AC voltage frequency when varying the writing beam intensity to generate phase change in 2π range. The modulation transfer function was also measured.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband single-shot electron spectrometer for GeV-class laser-plasma-based accelerators

Laser-plasma-based accelerators can provide electrons over a broad energy range and/or with large momentum spread. The electron beam energy distribution can be controlled via accurate control of laser and plasma properties, and beams with energies ranging from {approx_equal}0.5 to 1000 MeV have been observed. Measuring these energy distributions in a single shot requires the use of a diagnostic with large momentum acceptance and, ideally, sufficient resolution to accurately measure narrow energy spread beams. Such a broadband single-shot electron magnetic spectrometer for GeV-class laser-plasma-based accelerators has been developed at Lawrence Berkeley National Laboratory. Detailed descriptions of the design concept and hardware are presented, as well as a performance evaluation of the spectrometer. The spectrometer covered electron beam energies raging from 0.01 to 1.1 GeV in a single shot, and enabled the simultaneous measurement of the laser properties at the exit of the accelerator through the use of a sufficiently large pole gap. Based on measured field maps and third-order transport analysis, a few percent-level resolution and determination of the absolute energy were achieved over the entire energy range. Laser-plasma-based accelerator experiments demonstrated the capability of the spectrometer as a diagnostic and its suitability for measuring broadband electron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy characteristics of beam-plasma interaction in a closed volume

Energy exchange between an electron beam and plasma during a beam-plasma discharge in a closed cavity excited by the electron beam is analyzed using computer simulations by the KARAT code. A method allowing one to analyze the beam-plasma interaction in the quasi-steady stage of the discharge is proposed. Qualitative characteristics of energy exchange (such as beam energy losses and the energy distributions of beam electrons and plasma particles leaving the discharge) both during spontaneous discharge excitation and in the presence of initial beam modulation by regular or noiselike signals are determined. The results obtained enable one to estimate the energy characteristics of a plasma processing reactor based on a beam-plasma discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam profiles measured with thermoluminescent dosimeters

Beam profilometer, using thermoluminescent dosimeters, gives a quantitative and qualitative representation of the focus of an external protron beam of a synchrotron. The total number of particles in the beam, particle distribution, and the shape of the beam are determined.

Lucks, H.↗

Changes in the frequency distribution of energy deposited in short pathlengths as a function of energy degradation of the primary beam.

The frequency distributions of event size in the deposition of energy over small pathlengths have been measured after penetration of 44.3 MeV protons through various thicknesses of tissue-equivalent material. Results show that particle energy straggling of an initially monoenergetic proton beam after passage through an absorber causes the frequency distributions of energy deposited in short pathlengths of low atomic number materials to remain broad. In all cases investigated, the ratio of the most probable to the average energy losses has been significantly less than unity.

Baily, N. A.↗

SU-E-T-188: Film Dosimetry Verification of Monte Carlo Generated Electron Treatment Plans

Purpose: The purpose of this study was to compare dose distributions from film measurements to Monte Carlo generated electron treatment plans. Irradiation with electrons offers the advantages of dose uniformity in the target volume and of minimizing the dose to deeper healthy tissue. Using the Monte Carlo algorithm will improve dose accuracy in regions with heterogeneities and irregular surfaces. Methods: Dose distributions from GafChromic{sup ™} EBT3 films were compared to dose distributions from the Electron Monte Carlo algorithm in the Eclipse{sup ™} radiotherapy treatment planning system. These measurements were obtained for 6MeV, 9MeV and 12MeV electrons at two depths. All phantoms studied were imported into Eclipse by CT scan. A 1 cm thick solid water template with holes for bonelike and lung-like plugs was used. Different configurations were used with the different plugs inserted into the holes. Configurations with solid-water plugs stacked on top of one another were also used to create an irregular surface. Results: The dose distributions measured from the film agreed with those from the Electron Monte Carlo treatment plan. Accuracy of Electron Monte Carlo algorithm was also compared to that of Pencil Beam. Dose distributions from Monte Carlo had much higher pass rates than distributions from Pencil Beam when compared to the film. The pass rate for Monte Carlo was in the 80%–99% range, where the pass rate for Pencil Beam was as low as 10.76%. Conclusion: The dose distribution from Monte Carlo agreed with the measured dose from the film. When compared to the Pencil Beam algorithm, pass rates for Monte Carlo were much higher. Monte Carlo should be used over Pencil Beam for regions with heterogeneities and irregular surfaces.

60 APPLIED LIFE SCIENCES↗

Elastic scattering and total reaction cross section of {sup 6}He+{sup 120}Sn

The elastic scattering of {sup 6}He on {sup 120}Sn has been measured at four energies above the Coulomb barrier using the {sup 6}He beam produced at the RIBRAS (Radioactive Ion Beams in Brasil) facility. The elastic angular distributions have been analyzed with the optical model and three- and four-body continuum-discretized coupled-channels calculations. The total reaction cross sections have been derived and compared with other systems of similar masses.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗