Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Transport”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

An isotope harvesting beam blocker for the National Superconducting Cyclotron Laboratory

Harvesting isotopes from beam stops and other activated materials at accelerator facilities is a promising source of environmentally, scientifically and socially important radionuclides. At the Facility for Rare Isotope Beams (FRIB), a multitude of short- and long-lived radionuclides will be collected in a synergistic manner by dumping unused beams into a flowing-water beam stop. Ongoing exploratory research at the National Superconducting Cyclotron Laboratory (NSCL) with an analogous beam blocker aims towards obtaining the necessary radiochemical expertise for this endeavor. Herein we present a beam blocker and an isotope harvesting system which allows collection of a wide variety of aqueous and gaseous radionuclides. The water which flows through the beam blocker functions as an isotope production target and concurrently transports the newly formed radionuclides to collection sites. The system includes analytical instruments for online measurements of conductivity, dissolved oxygen, temperature, pressure and for detection of radiolytic products. To limit the levels of radiolytically produced hydrogen peroxide, a stainless-steel based degradation system was designed and implemented. Here, the suitability of the constructed system for the anticipated radionuclide harvesting project was demonstrated by offline tests and under irradiation with 140 MeV/u 48 Ca 20+ ions at the NSCL Coupled Cyclotron Facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical design for the single crystal neutron diffractometer Pioneer

Pioneer is a single-crystal neutron diffractometer optimized for small-volume samples and weak signals at the Second Target Station at Oak Ridge National Laboratory. This paper presents the preliminary optical design progress, focusing on the rationale behind key design choices. It covers the T 0 and bandwidth disk choppers, guide and beam control system, incident-beam polarizer, scattering beam collimators, and additional strategies. The chopper locations are selected to maximize neutron transport while taking advantage of standardized shielding structures. To accommodate the maintenance shield, operational shutter, and polarizing V-cavity, the guide design includes significant gaps. When these optical components are moved out of the beam path, oversized collimators, rather than guides, will be translated in. Pioneer will utilize slit packages to control beam size and divergence and a translatable polarizing V-cavity. Absorbing panels are strategically placed near the end station to minimize background. An oscillating radial collimator, operating in a shift mode, will be used with the vertical cylindrical detector, while a fixed multi-cone collimator will be used with the bottom flat detector. In conclusion, these collimators will enable the detection of weak signals when complex sample environments are used.

47 OTHER INSTRUMENTATION↗

A spectral metric for collider geometry

By quantifying the distance between two collider events, one can triangulate a metric space and reframe collider data analysis as computational geometry. One popular geometric approach is to first represent events as an energy flow on an idealized celestial sphere and then define the metric in terms of optimal transport in two dimensions. In this paper, we advocate for representing events in terms of a spectral function that encodes pairwise particle angles and products of particle energies, which enables a metric distance defined in terms of one-dimensional optimal transport. This approach has the advantage of automatically incorporating obvious isometries of the data, like rotations about the colliding beam axis. It also facilitates first-principles calculations, since there are simple closed-form expressions for optimal transport in one dimension. Up to isometries and event sets of measure zero, the spectral representation is unique, so the metric on the space of spectral functions is a metric on the space of events. At lowest order in perturbation theory in electron-positron collisions, our metric is simply the summed squared invariant masses of the two event hemispheres. Going to higher orders, we present predictions for the distribution of metric distances between jets in fixed-order and resummed perturbation theory as well as in parton-shower generators. Finally, we speculate on whether the spectral approach could furnish a useful metric on the space of quantum field theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Attosecond-Angstrom free-electron-laser towards the cold beam limit

Electron beam quality is paramount for X-ray pulse production in free-electron-lasers (FELs). State-of-the-art linear accelerators (linacs) can deliver multi-GeV electron beams with sufficient quality for hard X-ray-FELs, albeit requiring km-scale setups, whereas plasma-based accelerators can produce multi-GeV electron beams on metre-scale distances, and begin to reach beam qualities sufficient for EUV FELs. Here we show, that electron beams from plasma photocathodes many orders of magnitude brighter than state-of-the-art can be generated in plasma wakefield accelerators (PWFAs), and then extracted, captured, transported and injected into undulators without significant quality loss. These ultrabright, sub-femtosecond electron beams can drive hard X-FELs near the cold beam limit to generate coherent X-ray pulses of attosecond-Angstrom class, reaching saturation after only 10 metres of undulator. This plasma-X-FEL opens pathways for advanced photon science capabilities, such as unperturbed observation of electronic motion inside atoms at their natural time and length scale, and towards higher photon energies.

43 PARTICLE ACCELERATORS↗

Correlated characterization of 20 Ne-implanted targets using nuclear reaction analysis, Rutherford backscattering spectrometry, and ion transport modeling

In this article, we present the preparation and characterization of a large sample of implanted noble gas targets for use in precision nuclear astrophysics measurements with intense proton beams. Tantalum and titanium backings were prepared using wet-acid etching, outgassed via resistive heating, and implanted with 20 Ne + beams from differing ion sources. These experimental targets were investigated using both nuclear reaction analysis techniques on the 1169-keV resonance in 20 Ne(p, $\gamma$) 21 Na and Rutherford backscattering spectrometry analysis with 2-MeV α-particle beams. Results from these analyses reveal small target-to-target variations in stoichiometry, while exhibiting excellent agreement independent of ion-beam analysis method. We also present a self-consistent validation of the nuclear reaction analysis results using ion transport simulations in TRIM-2013 that rely on input parameters from SIMNRA scattering-yield fits to Rutherford backscattering spectra. In addition to a complete description of the implantation profile, this analysis method provides an alternate solution for characterizing a large sample of implanted targets when no suitable resonances are available for nuclear reaction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a platform for the gas transport, collection, and identification of fission products in the high-intensity laser environment

Recent progress in the production of laser accelerated high flux proton beams opens new possibilities for the study of fission in unique environments. To this end, we are currently pursuing the development of a platform for the swift gas transport, collection, and identification of fission products. Fission is induced in targets fixed inside a sealed chamber through which a carrier gas flows, transporting fission products to a carbon filter for collection and online spectroscopy. This has been recently demonstrated using target normal sheath accelerated protons at the PHELIX laser facility. There were large discrepancies between measured rates and those expected based on established fission yields and measured beam parameters. These discrepancies prompted a large number of tests at the Idaho Accelerator Center (IAC), where fission in uranium is induced by bremsstrahlung photons generated by 21 MeV electrons from a linear electron accelerator. Here, the results are compared to a series of models that account for the slowing of energetic fission fragments in the carrier gas and the fluid dynamics of the gas flow that transports fission products to the collection filter. Characterization of the apparatus reveals a few mechanisms that together account for a portion of the previously observed discrepancies at the PHELIX laser facility. However, additional research is necessary before high-accuracy experiments can be performed with the apparatus. Work performed under the auspices of the U.S. Department of Energy by LLNL under contract DE-AC52-07NA27344.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microstructure-Based Modeling of Laser Beam Shaping During Additive Manufacturing

Recent experimental studies suggest the use of spatially extended laser beam profiles as a strategy to control the melt pool during laser powder bed fusion (LPBF) additive manufacturing. However, linkages connecting laser beam profiles to thermal fields and resultant microstructures have not been established. Herein, we employ a coupled thermal transport-Monte Carlo model to predict the evolution of temperature fields and grain microstructures during LPBF using Gaussian, ring, and Bessel beam profiles. In addition, simulation results reveal that the ring-shaped beam yields lower temperatures compared with the Gaussian beam. Owing to the small melt pool size when using the Bessel beam, the grains are smaller in size and more equiaxed compared to those using the Gaussian and ring beams. Our approach provides future avenues to predict the impact of laser beam shaping on microstructure development during LPBF.

36 MATERIALS SCIENCE↗

Coalescence, the thermal model and multi-fragmentation: the energy and volume dependence of light nuclei production in heavy ion collisions

Here, we present results of a phase space coalescence approach within the UrQMD transport and -hybrid model for a very wide range of beam energies from SIS to LHC. The coalescence model is able to qualitatively describe the whole range of experimental data with a fixed set of parameters. Some systematic deviations are observed for very low beam energies where the role of feed down from heavier nuclei and multi-fragmentation becomes relevant. The coalescence results are mostly very close to the thermal model fits. However, both the coalescence approach as well as thermal fits are struggling to simultaneously describe the triton multiplicities measured with the STAR and ALICE experiment. The double ratio of tp/d 2 , in the coalescence approach, is found to be essentially energy and centrality independent for collisions of heavy nuclei at beam energies of E lab > 10A GeV. On the other hand the clear scaling of the d/p 2 and t/p 3 ratios with the systems volume is broken for peripheral collisions, where a canonical treatment and finite size effects become more important.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast ion relaxation in ITER mediated by Alfvén instabilities

Abstract We address the critical issue for future burning plasmas of whether high-energy fusion products or auxiliary heating-beam ions will be confined for a sufficiently long time to compensate for thermal plasma energy losses. This issue can be mitigated by one of the most deleterious collective phenomena—the instability of low, sub-cyclotron frequency Alfvén eigenmodes (AEs), such as toroidicity-induced AEs and reversed-shear AEs in the ITER steady-state scenario. Using a revised quasi-linear (QL) theory applied to energetic particle (EP) relaxation in the presence of AEs, we find that the AE instabilities can affect both neutral beam ions and alpha particles, although the resulting fast ion transport is expected to be modest if classical particle slowing down is assumed. On the other hand, the QL theory predicts that the AE amplitudes will be enhanced by the background microturbulence, although this topic remains outside our scope due to the significant numerical effort required to evaluate these effects. We report our results for EP relaxation dynamics obtained utilizing several tools: (i) a comprehensive linear stability study of the sub-cyclotron Alfvénic spectrum as computed by ideal magnetohydrodynamic NOVA simulations for the AE eigenproblem, (ii) drift kinetic NOVA-C calculations for wave–particle interaction and AE growth/damping rates, and (iii) predictive QL modeling coupled with the global transport code TRANSP to assess the EP relaxation on the equilibrium timescale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neural network emulation of flow in heavy-ion collisions at intermediate energies

Applications of new techniques in machine learning are speeding up progress in research in various fields. In this work, we construct and evaluate a deep neural network (DNN) to be used within a Bayesian statistical framework as a faster and more reliable alternative to the Gaussian process (GP) emulator of an isospin-dependent Boltzmann-Uehling-Uhlenbeck (IBUU) transport model simulator of heavy-ion reactions at intermediate beam energies. We found strong evidence of the DNN being able to emulate the IBUU simulator's prediction on the strengths of protons' directed and elliptical flow very efficiently even with small training datasets and with accuracy about ten times higher than the GP. Here, limitations of our present work and future improvements are also discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Regulation of Alfvén Eigenmodes by Microturbulence in Fusion Plasmas

Global gyrokinetic simulations of mesoscale reversed shear Alfven eigenmodes (RSAE) excited by energetic particles (EP) in fusion plasmas find that RSAE amplitude and EP transport are much higher than experimental levels at nonlinear saturation, but quickly diminish to very low levels after the saturation when background microturbulence is artificially suppressed. In contrast, in simulations coupling micro-meso scales, the RSAE amplitude and EP transport decrease drastically at the initial saturation but later increases to the experimental levels in the quasi-steady state with bursty dynamics due to regulation by thermal ion temperature gradient (ITG) microturbulence. The quasi-steady state EP transport is larger for a stronger microturbulence. Here, the RSAE amplitude in the quasi-steady state ITG-RSAE turbulence from gyrokinetic simulations, for the first time, agrees very well with experimental measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗

Towards Improving luminosity using optics tuning and data-driven methods

The results of Run 24 experiments at Relativistic Heavy Ion Collider (RHIC) for improving luminosity using optics tuning are presented in this study. In the first experiment, MADx matching was used to output magnet strengths corresponding to specific s star movements around Interaction Region 8 (IR8). The corresponding Zero Degree Calorimeter (ZDC) signal was measured in place of luminosity, and Bayesian Optimization aids search of optimal movements. It was found that values retrieved from matching were inaccurate, resulting in negative feedback loops. The second experiment focused on calculating accurate s star movements. The matching method was replaced with a linear sensitivity matrix, directly relating optics to power supply, and its null space was used to fit constraints such as hysteresis effects. At the experiment, beam losses were observed at collimators around boundary of IR8, which were fixed for the third experiment. Dynamic mode decomposition was also introduced to improve quality of turn-by-turn (TBT) data as well as accuracy and consistency of optics measurements at IR8. These improvements will be tested in the experiment of next RHIC run for luminosity optimization.

Accelerator Physics↗

Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) [and subsequently titled] Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022) (Final Report)

This is the Final Technical Report for the DOE Measurement Innovation grant DE-SC0017998 titled Neutral Atomic Beam Techniques for Diagnosis of Edge and Scrape-Off Layer Plasmas (2017-2019) and subsequently titled Neutral Atomic Beam Techniques for Diagnosis of Interior and Scrape-Off Layer Plasmas (2019-2022). The grant was funded by the Office of Fusion Energy Sciences (FES) for the period 1 September 2017 – 31 May 2022. Work performed through the grant has resulted in diagnostic innovations and new measurement capabilities that could improve understanding of magnetic equilibrium, edge localized modes in tokamaks, and bootstrap and Pfirsch-Schlüter currents in stellarators. We have performed simulations of a novel non-hydrogen beam-based diagnostic that would determine a local value (in the plasma) of the poloidal flux function by measuring the toroidal angle of the beam particles' velocity at a detector external to the plasma. The approach is similar to that of a Heavy Ion Beam Probe (HIBP), but would be able to operate with a smaller, more economical detection systems and, in doing so, may enable substantial extension of scenarios in which beam-based diagnostics are deployed. Key results include: Identification of the neutral and singly charged atoms that are most appropriate for use in the beam based diagnostic and the ionization cross-sections that are important for studying the plasma edge of a large device; Development of a promising geometry for operation in which the beam is injected horizontally near the torus midplane; Implementation of simulations using banana orbit trajectories of secondary beam ions to access plasma regions that are commonly in-accessible to an HIBP diagnostic, including sample volumes near the X-point of a diverted tokamak; Assessment of the ability of the diagnostic concept (originally developed under the assumption of, and reliant on, symmetry) to work in stellarators by performing simulations with both quasi-symmetric fields and non-quasi-symmetric fields; Measurement of noise levels with a prototype detector on a stellarator and exploration of techniques to minimize effects of noise on a diagnostic.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recent progress in laser wire-based H- beam diagnostics at the SNS linac

Laser wire has been used for nonintrusive profile and emittance measurements of operational hydrogen ion (H-) beam at the SNS linac. In this talk, we will describe the following recent developments in the laser wire system. 1) An upgraded light source and laser transport line which enables novel measurement capabilities including longitudinal profile measurement and high-energy proton beam extraction over potentially an entire macropulse. 2) A dual-detector emittance measurement scheme that boosted the dynamic range by an order of magnitude. 3) Design and implementation laser-wire-based nonintrusive longitudinal phase space measurement system.

Liu, Yun↗

General guide concepts for compact, high-brilliance neutron moderators

The trend in neutron sciences is toward integrating compact, high-brightness moderators into new or upgraded facilities. Transporting neutrons from the source to the sample position with a phase-space distribution tailored to specific requirements is crucial to leverage high source brilliance. Here we have investigated four guide concepts using Monte Carlo ray tracing simulations: Montel beamline with nested Kirkpatrick–Baez mirrors, curved-tapered beamline with a bender and straight sections, straight-elliptical beamline, and curved-elliptical beamline. The straight-elliptical (curved-elliptical) beamline features two half-ellipse guides connected by a straight (non-straight) guide section. The neutron transport efficiency and phase space homogeneity have been quantitatively compared. Our results show that the straight-elliptical beamline performs best because of few neutron bounces on the guide surface with small reflection angles, minimizing flux loss. The Montel beamline provides the best spatial confinement of neutrons within the desired region; however, there is a high thermal-neutron loss due to large reflection angles. The curved-tapered beamline suffers from significant flux loss due to high bounces, and it shows a non-uniform angular distribution related to broad ranges of bounces and reflection angles. The non-straight guide section of the curved-elliptical beamline increases the phase space inhomogeneity, leading to a spatially non-uniform beam profile. The results apply to general neutron instruments that require transporting thermal and cold neutrons from a compact, high-brilliance moderator to the sample location with a moderate phase-space volume.

47 OTHER INSTRUMENTATION↗