Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibrating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Detonation Shock Dynamics (DSD) Calibration for LX-17

The goal of this report is to summarize the results of a Detonation shock dynamics (DSD) calibration for the explosive LX-17. Considering that LX-17 is very similar to PBX 9502 (LX-17 is 92.5% TATB with 7.5% Kel-F 800 binder, while PBX 9502 is 95% TATB with 5% Kel-F 800 binder), we proceed with the analysis assuming many of the DSD constants are the same. We only change the parameters $D_{CJ}, B$ and $\bar{C}_6$ ($\bar{C}_6$ controls the how $D_{CJ}$ changes with pressing density). The parameters $D_{CJ}$ and $\bar{C}_6$ were given by Josh Coe and Sam Shaw's EOS. So, only B was optimized in fitting all the calibration data. This report first discusses some general DSD background, followed by a presentation of the available dataset to perform the calibration, and finally gives the results of the calibration and draws some conclusions. A DSD calibration of LX-17 has been conducted using the existing diameter effect data and shock shape records. The new DSD fit is based off the current PBX 9502 calibration and takes into account the effect of pressing density. Utilizing the PBX 9502 calibration, the effects of initial temperature can also be taken into account.

36 MATERIALS SCIENCE↗

Characterization and Valuation of the Uncertainty of Calibrated Parameters in Microsimulation Decision Models

We evaluated the implications of different approaches to characterize the uncertainty of calibrated parameters of microsimulation decision models (DMs) and quantified the value of such uncertainty in decision making. We calibrated the natural history model of CRC to simulated epidemiological data with different degrees of uncertainty and obtained the joint posterior distribution of the parameters using a Bayesian approach. We conducted a probabilistic sensitivity analysis (PSA) on all the model parameters with different characterizations of the uncertainty of the calibrated parameters. We estimated the value of uncertainty of the various characterizations with a value of information analysis. We conducted all analyses using high-performance computing resources running the Extreme-scale Model Exploration with Swift (EMEWS) framework. The posterior distribution had a high correlation among some parameters. The parameters of the Weibull hazard function for the age of onset of adenomas had the highest posterior correlation of -0.958. When comparing full posterior distributions and the maximum-a-posteriori estimate of the calibrated parameters, there is little difference in the spread of the distribution of the CEA outcomes with a similar expected value of perfect information (EVPI) of $\$$653 and $\$$685, respectively, at a willingness-to-pay (WTP) threshold of $\$$66,000 per quality-adjusted life year (QALY). Ignoring correlation on the calibrated parameters’ posterior distribution produced the broadest distribution of CEA outcomes and the highest EVPI of $\$$809 at the same WTP threshold. Different characterizations of the uncertainty of calibrated parameters affect the expected value of eliminating parametric uncertainty on the CEA. Ignoring inherent correlation among calibrated parameters on a PSA overestimates the value of uncertainty.

97 MATHEMATICS AND COMPUTING↗

Bias Impact Analysis and Calibration of UAV-Based Mobile LiDAR System with Spinning Multi-Beam Laser Scanner

Light Detection and Ranging (LiDAR) is a technology that uses laser beams to measure ranges and generates precise 3D information about the scanned area. It is rapidly gaining popularity due to its contribution to a variety of applications such as Digital Building Model (DBM) generation, telecommunications, infrastructure monitoring, transportation corridor asset management and crash/accident scene reconstruction. To derive point clouds with high positional accuracy, estimation of mounting parameters relating the laser scanners to the onboard Global Navigation Satellite System/Inertial Navigation System (GNSS/INS) unit, i.e., the lever-arm and boresight angles, is the foremost and necessary step. This paper proposes a LiDAR system calibration strategy for a Unmanned Aerial Vehicle (UAV)-based mobile mapping system that can directly estimate the mounting parameters for spinning multi-beam laser scanners through an outdoor calibration procedure. This approach is based on the use of conjugate planar/linear features in overlapping point clouds derived from different flight lines. Designing an optimal configuration for calibration is the first and foremost step in order to ensure the most accurate estimates of mounting parameters. This is achieved by conducting a rigorous theoretical analysis of the potential impact of bias in mounting parameters of a LiDAR unit on the resultant point cloud. The dependency of the impact on the orientation of target primitives and relative flight line configuration would help in deducing the configuration that would maximize as well as decouple the impact of bias in each mounting parameter so as to ensure their accurate estimation. Finally, the proposed analysis and calibration strategy are validated by calibrating a UAV-based LiDAR system using two different datasets—one acquired with flight lines at a single flying height and the other with flight lines at two different flying heights. With this being said, the calibration performance is evaluated by analyzing correlation between the estimated system parameters, the a-posteriori variance factor of the Least Squares Adjustment (LSA) procedure and the quality of fit of the adjusted point cloud to planar/linear features before and after the calibration process.

3D point clouds↗

Comparative Analysis of Thrombin Calibration Algorithms and Correction for Thrombin-α2macroglobulin Activity

Background: The thrombin generation (TG) test is useful for characterizing global hemostasis potential, but fluorescence substrate artifacts, such as thrombin-α2macroglobulin (T-α2MG) signal, inner filter effect (IFE), substrate consumption, and calibration algorithms have been suggested as sources of intra- and inter-laboratory variance, which may limit its clinical utility. Methods: Effects of internal vs. external normalization, IFE and T-α2MG on TG curves in normal plasma supplemented with coagulation factors, thrombomodulin, and tissue factor were studied using the Calibrated Automated Thrombinography (CAT; Diagnostica Stago, Parsippany, NJ, USA) and in-house software. Results: The various calibration methods demonstrated no significant difference in producing TG curves, nor increased the robustness of the TG assay. Several TG parameters, including thrombin peak height (TPH), produced from internal linear calibration did not differ significantly from uncalibrated TG parameters. Further, TPH values from internal linear and nonlinear calibration with or without T-α2MG correction correlated well with TPH from external calibration. Higher coefficients of variation (CVs) for TPH values were observed in both platelet-free and platelet-rich plasma with added thrombomodulin. Conclusions: Our work suggests minimal differences between distinct computational approaches toward calibrating and correcting fluorescence signals into TG levels, with most samples returning similar or equivalent TPH results.

59 BASIC BIOLOGICAL SCIENCES↗

Evolutions and Calibrations of Long Gamma-Ray-burst Luminosity Correlations Revisited

Luminosity correlations of long gamma-ray bursts (GRBs) are extensively proposed as an effective complementarity to trace the Hubble diagram of the universe at high redshifts, which is of great importance to explore properties of dark energy. Recently, several empirical luminosity correlations have been statistically proposed from GRB observations. However, to treat a GRB as the distance indicator, there are two key issues: the redshift evolution of luminosity correlations and their calibrations. In this paper, we choose the Amati relation, the correlation between the peak spectra energy and the equivalent isotropic energy of GRBs (E{sub p}--E{sub iso}) as an example and find that the current GRB data set implies that there could be a evolution of the luminosity correlation with respect to the redshift. Therefore, we propose an extended Amati relation with two extra redshift-dependent terms to correct the redshift evolution of the GRB relation. Second, we carefully check the reliability of the calibration method using the low-redshift GRB data. Importantly, we find that the low-redshift calibration method does not take whole correlations between Ω{sub m} and coefficients into account. Neglecting this correlation information can break the degeneracies and obtain the biased constraint on Ω{sub m}, which is very sensitive to values of parameters for the calibration. A small shift in the parameters of the “calibrated” relation could significantly change the final constraint on Ω{sub m} in the low-redshift calibration method. Finally, we simulate several GRB samples with different statistical errors and find that, in order to correctly recover the fiducial value of Ω{sub m}, using the low-redshift calibration method, we need a large number of GRB samples with high precisions.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method to calibrate fission chambers in Campbelling mode

Fission chambers are neutron detectors which are widely used to instrument experimental reactors such as material testing reactors or zero power reactors. In the presence of a high level mixed gamma and neutron flux, fission chambers can be operated in Campbelling mode (also known as 'fluctuation mode' or 'mean square voltage mode') to provide reliable and precise neutron related measurements. Fission chamber calibration in Campbelling mode (in terms of neutron flux) is usually done empirically using a calibrated reference detector. A major drawback of this method is that calibration measurements have to be performed in a neutron environment very similar to the one in which the calibrated detector will be used afterwards. What we propose here is a different approach based on characterizing the fission chamber response in terms of fission rate. This way, the detector calibration coefficient is independent from the neutron spectrum and can be determined prior to the experiment. The fissile deposit response to the neutron spectrum can then be assessed independently by other means (experimental or numerical). In this paper, the response of CEA made miniature fission chambers in Campbelling mode is studied. We use a theoretical model of the signal to calculate the calibration coefficient. Input parameters of the model come from statistical distribution of individual pulses. Supporting measurements have been made in the CEA Cadarache zero power reactor MINERVE. Results are compared to an empirical Campbelling mode calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending Sensor Calibration Intervals in Nuclear Power Plants

Currently in the USA, sensor recalibration is required at every refueling outage, and it has emerged as a critical path item for shortening outage duration. International application of calibration monitoring, such as at the Sizewell B plant in UK, has shown that sensors may operate for eight years, or longer, within calibration tolerances. Online monitoring can be employed to identify those sensors which require calibration, allowing for calibration of only those sensors which need it. The US NRC accepted the general concept of online monitoring for sensor calibration monitoring in 2000, but no plants have been granted the necessary license amendment to apply it. This project addresses key issues in advanced recalibration methodologies and provides the science base to enable adoption of best practices for applying online monitoring, resulting in a public domain standardized methodology for sensor calibration interval extension. Research to develop this methodology will focus on three key areas: (1) quantification of uncertainty in modeling techniques used for calibration monitoring, with a particular focus on non-redundant sensor models; (2) accurate determination of acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and (3) the use of virtual sensor estimates to replace identified faulty sensors to extend operation to the next convenient maintenance opportunity.

Calibration Extension↗

Mathematical Calibration of Modular Plastic Scintillators for Various Assay Applications - 17322

Plastic scintillators provide an inexpensive option to assay and characterize radioactive material. Due to the low cost it is generally possible to an array of large numbers of plastic scintillators to achieve high measurement efficiencies. The beta only thin plastic scintillators used in the Argos contamination monitors provide a convenient and reliable scintillator package that can be grouped together to form an assay system. Mathematical calibrations, using MCNP, have been produced for this detector that allow for rapid construction of various custom measurement geometries. The calibrations were constructed by comparing a series of measurements made with a number of beta and beta/gamma emitting nuclides. Characterization of the beta scintillators utilized beta emitting nuclides that included spectra from low average energy, e.g. C-14, to relatively high average energy, e.g. Sr/Y-90. In order to perform the calibration, custom versions of the standard Argos scintillators were produced that provide an MCA output for spectroscopic investigation. The spectra were then compared to detailed MCNP models in an iterative process to energy calibrate and efficiency calibrate each detector type. The validated models and energy calibrations were then tested against a number of volumetric geometries to confirm that the model would translate well to any other geometry. These validated models can then be used to rapidly construct custom measurement geometries for material measurement and screening. Two examples of measurement applications include a beta screening system for dirt on a conveyor belt and a flow through beta liquid assay system. The mathematical calibration process, validation results, and a number of application examples are discussed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-objective surrogate-assisted calibration of CPFEM models using macroscopic response and in situ EBSD measurements of grain reorientation trajectories

Crystal plasticity finite element method (CPFEM) models are widely used to simulate the deformation behaviour of polycrystalline materials, but their calibration is often limited by their high computational cost and the non-convexity of the optimisation landscape. Here, this study develops a multi-objective surrogate-assisted calibration workflow that couples a multi-objective genetic algorithm (MOGA) with an adaptively trained deep neural network (DNN) surrogate model to efficiently identify CPFEM parameters from experimental data. The workflow is demonstrated on three crystal plasticity (CP) formulations of increasing complexity — Voce hardening (VH), two-coefficient latent hardening (LH2), and six-coefficient latent hardening (LH6) — using in situ electron backscatter diffraction (EBSD) measurements of Alloy 617 under uniaxial tensile loading. The CPFEM models are calibrated against the experimentally observed stress–strain response and reorientation trajectories of eight grains, then validated against eight additional trajectories and overall texture evolution. Across the CP formulations, the macroscopic response was reproduced reliably, while differences emerged in the robustness and accuracy of the grain-scale predictions. Including grain reorientation trajectories in the multi-objective calibration improved texture evolution predictions and filtered out physically inconsistent parameter sets that can arise from calibrating against only the stress–strain data. The workflow also demonstrates good transferability of calibrated parameters from a low- to a high-fidelity microstructural model. These results provide practical guidance for integrating in situ microstructural data into CPFEM through efficient, repeatable, and physically meaningful multi-objective calibration.

Crystal plasticity finite element method↗

An algorithmic calibration approach to identify globally optimal parameters for constraining the DayCent model

he accurate calibration of complex biogeochemical models is essential for the robust estimation of soil greenhouse gases (GHG) as well as other environmental conditions and parameters that are used in research and policy decisions. DayCent is a popular biogeochemical model used both nationally and internationally for this purpose. Despite DayCent’s popularity, its complex parameter estimation is often based on experts’ knowledge which is somewhat subjective. In this study we used the inverse modelling parameter estimation software (PEST), to calibrate the DayCent model based on sensitivity and identifi- ability analysis. Using previously published N2 O and crop yield data as a basis of our calibration approach, we found that half of the 140 parameters used in this study were the primary drivers of calibration dif- ferences (i.e. the most sensitive) and the remaining parameters could not be identified given the data set and parameter ranges we used in this study. The post calibration results showed improvement over the pre-calibration parameter set based on, a decrease in residual differences 79% for N2O fluxes and 84% for crop yield, and an increase in coefficient of determination 63% for N2O fluxes and 72% for corn yield. The results of our study suggest that future studies need to better characterize germination tem- perature, number of degree-days and temperature dependency of plant growth; these processes were highly sensitive and could not be adequately constrained by the data used in our study. Furthermore, the sensitivity and identifiability analysis was helpful in providing deeper insight for important processes and associated parameters that can lead to further improvement in calibration of DayCent model.

Corn yield↗

An empirical calibration of the serpentine-water oxygen isotope fractionation at T = 25–100°C

The ability to precisely constrain the physical–chemical conditions of serpentinization, such as temperature and fluid source, is limited by the accuracy of calibrations for oxygen isotope fractionation between serpentine and water – i.e., 1000 lnα( serpentine-water ) – which disagree by up to 20‰ when extrapolated to T<200°C. In this study, we present a new empirical calibration of 1000 lnα( serpentine-water ) aiming to improve applications of oxygen isotope geochemistry to very low-T serpentinization (T<100°C). We used the high-spatial resolution capabilities of Secondary Ion Mass Spectrometry (SIMS) to analyze oxygen isotope ratios in mineral pairs of calcite + serpentine, quartz + serpentine and talc + serpentine co-crystallized at scales≤50μm in six serpentinite samples from the Samail ophiolite (Oman). SIMS analysis shows that the mineral pairs are relatively homogenous in oxygen isotope ratios with variability in δ 18 O values ≤2‰ (2s). Clumped isotope thermometry and petrological constraints indicate crystallization temperatures from 25 to 100°C for the investigated samples. These independent constraints on temperature allowed us to derive 1000 lnα( serpentine-water ) by combining Δ 18 O( quartz-serpentine ), Δ 18 O( talc-serpentine ) and Δ 18 O( calcite-serpentine ) measured by SIMS in the investigated samples with Δ 18 O( quartz-water ), Δ 18 O( talc-water ) and Δ 18 O( calcite-water ) calibrations available in the literature. Our empirical calibration of 1000 lnα( serpentine-water ) = 1.04±0.20 (2SE) × 10 6 /T 2 (T in K), from T = 25 to 100°C, is within uncertainty of former high-temperature empirical calibrations extrapolated to T<100°C and matches experimental calibrations when extrapolated to T=250°C. In conclusion, the new serpentine-water calibration enables more accurate reconstructions of fluid-rock interactions occurring during low-temperature serpentinization processes in various tectonic settings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Water Calibration Measurements for Neutron Radiography: Application to Water Content Quantification in Porous Media

Using neutron radiography, the measurement of water thickness was performed using aluminum (Al) water calibration cells at the High Flux Isotope Reactor (HFIR) Cold-Guide (CG) 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA. Calibration of water thickness is an important step to accurately measure water contents in samples of interest. Neutron attenuation by water does not vary linearly with thickness mainly due to beam hardening and scattering effects. Transmission measurements for known water thicknesses in water calibration cells allow proper correction of the underestimation of water content due to these effects. As anticipated, strong scattering effects were observed for water thicknesses greater than 2 mm when the water calibration cells were positioned close to the face of the detector / scintillator (0 and 2.4 cm away, respectively). The water calibration cells were also positioned 24 cm away from the detector face. These measurements resulted in less scattering and this position (designated as the sample position) was used for the subsequent experimental determination of the neutron attenuation coefficient for water. Neutron radiographic images of moist Flint sand in rectangular and cylindrical containers acquired at the sample position were used to demonstrate the applicability of the water calibration. Cumulative changes in the water volumes within the sand columns during monotonic drainage determined by neutron radiography were compared with those recorded by direct reading from a burette connected to a hanging water column. In general, the neutron radiography data showed very good agreement with those obtained volumetrically using the hanging water-column method. These results allow extension of the calibration equation to the quantification of unknown water contents within other samples of porous media.

Kang, Misun↗

Data fusion for a vision-aided radiological detection system: Calibration algorithm performance

In order to improve the ability to detect, locate, track and identify nuclear/radiological threats, the University of Florida nuclear detection community has teamed up with the 3D vision community to collaborate on a low cost data fusion system. The key is to develop an algorithm to fuse the data from multiple radiological and 3D vision sensors as one system. The system under development at the University of Florida is being assessed with various types of radiological detectors and widely available visual sensors. A series of experiments were devised utilizing two EJ-309 liquid organic scintillation detectors (one primary and one secondary), a Microsoft Kinect for Windows v2 sensor and a Velodyne HDL-32E High Definition LiDAR Sensor which is a highly sensitive vision sensor primarily used to generate data for self-driving cars. Each experiment consisted of 27 static measurements of a source arranged in a cube with three different distances in each dimension. The source used was Cf-252. The calibration algorithm developed is utilized to calibrate the relative 3D-location of the two different types of sensors without need to measure it by hand; thus, preventing operator manipulation and human errors. The algorithm can also account for the facility dependent deviation from ideal data fusion correlation. Use of the vision sensor to determine the location of a sensor would also limit the possible locations and it does not allow for room dependence (facility dependent deviation) to generate a detector pseudo-location to be used for data analysis later. Using manually measured source location data, our algorithm-predicted the offset detector location within an average of 20 cm calibration-difference to its actual location. Calibration-difference is the Euclidean distance from the algorithm predicted detector location to the measured detector location. The Kinect vision sensor data produced an average calibration-difference of 35 cm and the HDL-32E produced an average calibration-difference of 22 cm. Using NaI and He-3 detectors in place of the EJ-309, the calibration-difference was 52 cm for NaI and 75 cm for He-3. In conclusion, the algorithm is not detector dependent; however, from these results it was determined that detector dependent adjustments are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of cloud and aerosol related parameters for solar irradiance forecasts in WRF-solar

Model parameters are a major source of uncertainty in numerical weather prediction. Recently, the Weather Research and Forecasting model with Solar extensions (WRF-Solar) has been upgraded by enhancing the treatment of sub-grid scale cloud and aerosols with augmentations of a sub-grid scale cloud scheme (CLD3) and an upgraded aerosol-aware Thompson-Eidhammer scheme (TE14). However, the value of model parameters associated with these parameterizations are assigned based on limited measurements or theoretical calculations. Calibrating the most sensitive parameters has the potential to improve solar irradiance predictions. Here, we adopted a multiobjective surrogate-based optimization (SBO) framework to calibrate nine parameters used in CLD3 and TE14 that lead to the largest sensitivity in simulated irradiance. The normalized mean-absolute-error (NMAE) of global horizontal irradiance (GHI) and direct normal irradiance (DNI) are minimized by calibrating WRF-Solar over two regions including the Southern Great Plains (SGP) and Central California, in order to focus on parameter calibration under cloudy conditions with different aerosol loading. The results show that generalized linear model (GLM)-based surrogate models approximate physical models well, particularly when the third order and three-way interaction terms are considered. The SBO framework efficiently searches the parameter space for optimal solutions with less computational costs than directly calibrating the physical model. We first calibrate CLD3 parameters over the less-polluted SGP region. Optimized CLD3 parameters alone result in NMAE reduction by 14% for the site-mean and up to 33% for individual cases over the SGP region. With further calibration of TE14 parameters over the Central California during active fire periods, the optimized parameters lead to over 20% reductions of NMAE. Our investigation reveals, however, that optimizing TE14 has a limited impact on irradiance simulations under less-polluted conditions in the SGP.

14 SOLAR ENERGY↗

J-PLUS: Systematic impact of metallicity on photometric calibration with the stellar locus

Here, we present the photometric calibration of the twelve optical passbands for the Javalambre Photometric Local Universe Survey (J-PLUS) second data release (DR2), comprising 1088 pointings of two square degrees, and study the systematic impact of metallicity on the stellar locus technique. The [Fe/H] metallicity from the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) for 146 184 high-quality calibration stars, defined with signal-to-noise ratio larger than ten in J-PLUS passbands and larger than three in Gaia parallax, was used to compute the metallicity-dependent stellar locus (ZSL). The initial homogenization of J-PLUS photometry, performed with a unique stellar locus, was refined by including the metallicity effect in colors via the ZSL. The variation of the average metallicity along the Milky Way produces a systematic offset in J-PLUS calibration. This effect is well above 1% for the bluer passbands and amounts 0.07, 0.07, 0.05, 0.03, and 0.02 mag in u, J0378, J0395, J0410, and J0430, respectively. We modeled this effect with the Milky Way location of the J-PLUS pointing, also providing an updated calibration for those observations without LAMOST information. The estimated accuracy in the calibration after including the metallicity effect is at 1% for the bluer J-PLUS passbands and below for the rest. Photometric calibration with the stellar locus technique is prone to significant systematic bias in the Milky Way for passbands bluer than λ = 4500 Å. The calibration method for J-PLUS DR2 reaches 1–2% precision and 1% accuracy for 12 optical filters within an area of 2176 square degrees.

79 ASTRONOMY AND ASTROPHYSICS↗

Star formation rate and stellar mass calibrations based on infrared photometry and their dependence on stellar population age and extinction

The stellar mass (M $\star$ ) and the star formation rate (SFR) are among the most important features that characterize galaxies. Measuring these fundamental properties accurately is critical for understanding the present state of galaxies, their history, and future evolution. Infrared (IR) photometry is widely used to measure the M $\star$ and SFR of galaxies because the near-IR traces the continuum emission of the majority of their stellar populations (SPs), and the mid/far-IR traces the dust emission powered by star-forming activity. This work explores the dependence of the IR emission of galaxies on their extinction, and the age of their SPs. It aims to provide accurate and precise IR-photometry SFR and M $\star$ calibrations that account for SP age and extinction while providing quantification of their scatter. We used the CIGALE spectral energy distribution (SED) fitting code to create model SEDs of galaxies with a wide range of star formation histories, dust content, and interstellar medium properties. We fit the relations between M $\star$ and SFR with IR and optical photometry of the model-galaxy SEDs with the Markov chain Monte Carlo (MCMC) method. As an independent confirmation of the MCMC fitting method, we performed a machine-learning random forest (RF) analysis on the same data set. The RF model yields similar results to the MCMC fits, thus validating the latter. This work provides calibrations for the SFR using a combination of the WISE bands 1 and 3, or the JWST NIR-F200W and MIRI-F2100W. It also provides mass-to-light ratio calibrations based on the WISE band-1, the JWST NIR-F200W, and the optical u - r or g - r colors. These calibrations account for the biases attributed to the SP age, while they are given in the form of extinction-dependent and extinction-independent relations. The proposed calibrations show robust estimations while minimizing the scatter and biases throughout a wide range of SFRs and stellar masses. The SFR calibration offers better results, especially in dust-free or passive galaxies where the contributions of old SPs or biases from the lack of dust are significant. Similarly, the M $\star$ calibration yields significantly better results for dusty and high-SFR galaxies where dust emission can otherwise bias the estimations.

79 ASTRONOMY AND ASTROPHYSICS↗

Delving into the depths of NGC 3783 with XRISM II. Cross-calibration of X-ray instruments used in the large, multi-mission observational campaign

Context. Accurate X-ray spectroscopic measurements are fundamental for deriving basic physical parameters of the most abundant baryon components in the Universe. The plethora of X-ray observatories currently operational enables a panchromatic view of the high-energy emission of celestial sources. However, uncertainties in the energy-dependent calibration of the instrument transfer functions (e.g. the effective area, energy redistribution, or gain) can limit - and historically, did limit - the accuracy of X-ray spectroscopic measurements. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign. Aims. We revised the status of the cross-calibration among the scientific payload on board four operation missions: Chandra, NuSTAR, XMM-Newton, and the recently launched XRISM. XRISM carries the micro-calorimeter Resolve, which yields the best energy resolution at energies ≥2 keV. For this purpose, we used the data from a 10-day-long observational campaign targeting the nearby active galactic nucleus NGC 3783, carried out in July 2024. Methods. We present a novel model-independent method for assessing the cross-calibration status that is based on a multi-node spline of the spectra with the highest-resolving power (XRISM/Resolve in our campaign). We also estimated the impact of the intrinsic variability of NGC 3783 on the cross-calibration status due to the different time coverages of participating observatories and performed an empirical reassessment of the Resolve throughput at low energies. Results. Based on this analysis, we derived a set of energy-dependent correction factors of the observed responses, enabling a statistically robust analysis of the whole spectral dataset. They will be employed in subsequent papers describing the astrophysical results of the campaign.

Active Galactic Nuclei, individual: NGC 3783↗