Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calorimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Bi-metallic Nanoparticle Synthesis for Advanced Manufactured Melt Wires

Science Undergraduate Laboratory Internship (SULI) Program Report: Additive manufacturing (AM) based on direct-write technologies has emerged as the predominant method for the fabrication of passive sensors for the harsh operating environments seen in a nuclear reactor. Through the modification of previous methods, Idaho National Laboratory and Villanova University have improved the synthesis process for AM feedstock, which will allow for the improvement of advanced nuclear sensors and instrumentation. A major part of this work includes the synthesis process of relevant AM compatible feedstock to support the development, fabrication, and testing of AM sensors for peak temperature detection. For this report, bismuth, bismuth/platinum, tin, tin/silver, tin/zinc, indium, and indium/silver bi-metallic nanoparticles were synthesized using the polyol method, which will enhance temperature sensitivity and allow for miniaturization. To characterize the synthesized nanoparticles, we used x-ray fluorescence to evaluate the elemental composition of the nanoparticles and differential scanning calorimetry and thermogravimetric analysis to determine the melting point and mass loss of the samples. Results show that bi-metallic nanoparticles are a viable option for the fabrication of high-resolution AM melt wires. The temperature sensitivity can be brought to within 5°C and melt wires can be fabricated that are in the micrometer scale. This will expand the range of irradiation experiments melt wires can be used for and the measured temperature will be significantly more accurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Develop Accurate Techniques for Passive SiC Temperature Monitoring of Miniature Samples for Cross-Cutting Applications

Passive thermometry is critically important because most fuels and materials irradiation experiments are not instrumented, and it is necessary to understand the irradiation temperature to properly interpret any post-irradiation examination data, including evolving properties and/or microstructures. The standard passive thermometry approach uses continuous dilatometry to evaluate changes in the instantaneous coefficient of thermal expansion during post-irradiation thermal annealing. This approach has limitations in terms of sample size (minimum length requirements) and the maximum irradiation temperature that can be accurately determined, which is limited by the reduced swelling (and therefore recovery) following higher temperature irradiation and limitations on the furnaces used with push-rod dilatometers. This work evaluates two new proposed techniques for post-irradiation evaluation of passive SiC temperature monitors: differential scanning calorimetry (DSC) and Raman spectroscopy. DSC is an extremely sensitive technique that can be used for any specimen geometry and is capable of higher temperature operation. Raman spectroscopy is similar in that it is a surface technique capable of examining extremely small samples (submillimeter), can be used with a heated stage up to 1,500°C (planned for future work), and is capable of mapping local irradiation temperatures throughout a sample. Existing SiC samples that were previously irradiated over a wide range of temperatures were cut into multiple pieces to allow for annealing studies using multiple different techniques: dilatometry, DSC, and Raman spectroscopy. This approach mitigates the concern that samples analyzed using one technique may have a slightly different irradiation history than those analyzed using a different technique. Recovery was clearly observed during annealing using both DSC and dilatometry. In some cases, a direct comparison could not be made due to some of the DSC runs accidentally including material from multiple specimens and issues with using an alternative DSC sample holder for the highest temperature annealing studies. Nevertheless, one trend was clear: the DSC runs resulted in higher irradiation temperatures compared to those of the dilatometry runs. Part of this could be attributed to the higher temperature ramp rates used during the DSC runs, which are often preferred to reduce noise in the measurements. By comparison, dilatometry has previously been shown to produce better data at lower ramp rates. Future work should further investigate the ideal ramp rate for both techniques to produce consistent results. Additional work should evaluate the best holder material to use for DSC runs exceeding 1,000°C to provide reliable data while preventing interactions between SiC and the holder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Results from ADRIANO2 Test Beams

A novel high-granularity, dual-readout calorimetric technique (ADRIANO2) is under development as part of the research program of T1604 Collaboration. (Talk Presented at the 19th International Conference on Calorimetry in Particle Physics (CALOR 2022), University of Sussex, Sussex, UK, 16–20 May 2022). The building block of such a calorimeter consists of a pair of optically isolated, small size tiles made of scintillating plastic and lead glass. The prompt Čerenkov light from the glass can be exploited to perform high resolution timing measurements, while the high granularity provides good resolution of the spatial components of the shower. Dual-readout compensation and particle flow techniques can be applied simultaneously to the scintillation and to the Čerenkov section, providing excellent energy resolution as well as PID particle identification. These characteristics make ADRIANO2 a 6-D detector, suited for High Energy as well as High Intensity experiments. A report on the status of the ADRIANO2 project, preliminary measurements of light yield, and current and future R&D plans by T1604 Collaboration are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The SiD Digital ECal Based on Monolithic Active Pixel Sensors

The SiD detector concept capitalizes on high granularity in its tracker and calorimeter to achieve the momentum resolution and particle flow calorimetry physics goals in a compact design. The collaboration has had a long interest in the potential for improved granularity in both the tracker and ECal with an application of monolithic active pixel sensors (MAPS) and a study of MAPS in the SiD ECal was described in the ILC TDR. Work is progressing on the MAPS application in an upgraded SiD design with a prototyping design effort for a common SiD tracker/ECal design based on stitched reticules to achieve 10 × 10 cm2 sensors with 25 × 100 micron2 pixels. Application of large area MAPS in these systems would limit delicate and expensive bump-bonding, provide possibilities for better timing, and should be significantly cheaper than the TDR concept due to being a more conventional CMOS foundry process. The small pixels significantly improve shower separation. Recent simulation studies confirm previous performance projections, indicating electromagnetic energy resolution based on digital hit cluster counting provides better performance than the SiD TDR analog design based on 13 mm2 pixels. Furthermore, the two shower separation is excellent down to the millimeter scale. Geant4 simulation results demonstrate these expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Eu(III) and Cm(III) Complexation by the Aminocarboxylates NTA, EDTA, and EGTA Studied with NMR, TRLFS, and ITC—An Improved Approach to More Robust Thermodynamics

The complex formation of Eu(III) and Cm(III) was studied via tetradentate, hexadentate, and octadentate coordinating ligands of the aminopolycarboxylate family, viz., nitrilotriacetate (NTA 3- ), ethylenediaminetetraacetate (EDTA 4- ), and ethylene glycol-bis(2-aminoethyl ether)-N,N,N',N'-tetraacetate (EGTA 4- ), respectively. Based on the complexones’ pK a values obtained from 1 H nuclear magnetic resonance (NMR) spectroscopic pH titration, complex formation constants were determined by means of the parallel-factor-analysis-assisted evaluation of Eu(III) and Cm(III) time-resolved laser-induced fluorescence spectroscopy (TRLFS). This was complemented by isothermal titration calorimetry (ITC), providing the enthalpy and entropy of the complex formation. This allowed us to obtain genuine species along with their molecular structures and corresponding reliable thermodynamic data. The three investigated complexones formed 1:1 complexes with both Eu(III) and Cm(III). Besides the established Eu(III)–NTA 1:1 and 1:2 complexes, we observed, for the first time, the existence of a Eu(III)–NTA 2:2 complex of millimolar metal and ligand concentrations. Demonstrated for thermodynamic studies on Eu(III) and Cm(III) interaction with complexones, the utilized approach is commonly applicable to many other metal–ligand systems, even to high-affinity ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Behavior of the Ternary NaCl-PuCl 3 -Pu Molten Salt

There is a gap in our understanding of the behavior of fused and molten fuel salts containing unavoidable contamination, such as those due to fabrication, handling, or storage. Therefore, this work used calorimetry to investigate the change in liquidus temperature of PuCl 3 , having an unknown purity and that had been in storage for several decades. Further research was performed by additions of NaCl, making several compositions within the binary system, and summarizing the resulting changes, if any, to the phase diagram. The melting temperature of the PuCl 3 was determined to be 746.5°C, approximately 20°C lower than literature reported values, most likely due to an excess of Pu metal in the PuCl 3 either due to the presence of metallic plutonium remaining from incomplete chlorination or due to the solubility of Pu in PuCl 3 . From the melting temperature, it was determined that the PuCl 3 contained between 5.9 to 6.2mol% Pu metal. Analysis of the NaCl-PuCl 3 samples showed that using the Pu rich PuCl 3 resulted in significant changes to the NaCl-PuCl 3 phase diagram. Most notably an unreported phase transition occurring at approximately 406°C and a new eutectic composition of 52.7mol% NaCl–38.7mol% PuCl 3 –2.5mol% Pu which melted at 449.3°C. Additionally, an increase in the liquidus temperatures was seen for NaCl rich compositions while lower liquidus temperatures were seen for PuCl 3 rich compositions. It can therefore be concluded that changes will occur in the NaCl-PuCl 3 binary system when using PuCl 3 with excess Pu metal. However, melting temperature analysis can provide valuable insight into the composition of the PuCl 3 and therefore the NaCl-PuCl 3 system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Heats of mixing in praseodymium-neodymium solid solutions.

The heats of solution in liquid tin of pure praseodymium, pure neodymium and nine praseodymium-neodymium binary alloys have been measured using liquid metal solution calorimetry. A plot of the measured heat effect for the alloys as a function of composition is linear, with the terminal points being the measured values for the pure components. This linear dependency indicates that the heat of mixing in the binary praseodymium-neodymium system is zero within experimental error, and therefore the binary alloys obey one of the criteria for an ideal solution.

Calorimetry↗

Synthesis, Characterization, and Theoretical Considerations of 1,2-bis(oxyamino)ethane Salts

The synthesis, characterization, theoretical calculations, and safety studies of energetic salts of 1,2- bis(oxyamino) ethane, (H2N-O-CH2-CH2-O-NH2), were carried out. The salts were characterized by vibrational (infrared, Raman), multinuclear nmr studies (1H, 13C), differential scanning calorimetry (DSC); elemental analysis; and initial safety testing (impact and friction sensitivity) . Theoretical calculations on the neutral, monoprotonated, and doubly protonated species of ethylene bisoxyamine were carried out using xxxx level of theory for the lowest energy structure and these theoretical results compared with the experimentally observed bond distances and vibrational (ir, Raman) frequency values. The single crystal X-ray diffraction study was carried out on the mono-perchlorate salt revealing a high degree of hydrogen bonding with an unexpected structure.

1-2-BIS- (OXYAMINO)ETHANE SALTS↗

Endogenous thermoregulatory rhythms of squirrel monkeys in thermoneutrality and cold

Whole body heat production (HP) and heat loss (HL) were examined to determine if the free-running circadian rhythm in body temperature (Tb) results from coordinated changes in HP and HL rhythms in thermoneutrality (27 degrees C) as well as mild cold (17 degrees C). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of Tb and activity. Feeding was also measured. Rhythms of HP, HL, and conductance were tightly coupled with the circadian Tb rhythm at both ambient temperatures (TA). At 17 degrees C, increased HP compensated for higher HL at all phases of the Tb rhythm, resulting in only minor changes to Tb. Parallel compensatory changes of HP and HL were seen at all rhythm phases at both TA. Similar time courses of Tb, HP, and HL in their respective rhythms and the relative stability of Tb during both active and rest periods suggest action of the circadian timing system on Tb set point.

NASA Discipline Regulatory Physiology↗