Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Temperature-dependence of structural and mechanical properties of TiB{sub 2}: A first principle investigation

High temperature mechanical and thermodynamic properties of TiB{sub 2} are important to its applications as ultrahigh temperature ceramic, which were not well understood. In this study, the thermodynamic and mechanical properties of TiB{sub 2} were investigated by the combination of first principle and phonon dispersion calculations. The thermal expansion of TiB{sub 2} was anisotropic, α{sub c}/α{sub a} is nearly constant (1.46) from 300 K to 1500 K, theoretically. The origination of this anisotropy is the anisotropic compressibility. The heat capacity at constant pressure was estimated from the theoretical entropy and fitted the experimental result quite well when higher-order anharmonic effects were considered. Theoretical isentropic elastic constants and mechanical properties were calculated and their temperature dependence agreed with the existed experiments. From room temperature to 1500 K, the theoretical slope is −0.0211 GPa·K{sup −1}, −0.0155 GPa·K{sup −1}, and −0.0384 GPa·K{sup −1} for B, G, and E, respectively. Our theoretical results highlight the suitability of this method in predicting temperature dependent properties of ultrahigh temperature ceramics and show ability in selecting and designing of novel ultrahigh temperature ceramics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

System-Level Comparison of Sodium and Salt Systems in Support of the Gen3 Liquids Pathway

This paper presents the comparison of the annual performance and the Levelised Cost of Energy (LCOE) of two high- temperature solar power tower configurations using a 565MWth chloride salt receiver and a 540 MWth liquid sodium receiver. Each power tower consists of a sodium or salt receiver, a 175 m high concrete tower, and a two-tank chloride salt system for thermal energy storage (TES). The power plants were simulated using SolarTherm to estimate their energy per year, capacity factor, and LCOE. The simulation was verified against the System Advisor Model (SAM), showing that the LCOE calculation differences are within ±1.0%. Results showed that the sodium-receiver system yields 69.60 USD/MWh real LCOE, versus 78.55 USD/MWh for the chloride salt system. Results also showed that sodium wins here due to a smaller and more efficient receiver, enabled by higher flux limits and reduced field size, leading to less mirror reflective area and site improvement cost.

capacity factor↗

Supercritical CO 2 uptake by nonswelling phyllosilicates

Significance Reliable estimates of geologic carbon storage capacities (needed for policymaking) in both saline aquifers and unconventional gas/oil shales rely on understanding trapping mechanisms. We found that CO 2 uptake by muscovite (a common mineral and a conservative proxy for illite) far exceeds the maximum adsorption capacity of its external surface area. Our measurements using different methods collectively suggest that CO 2 enters muscovite interlayers without bulk interlayer expansion, contrary to the conventional wisdom that only swelling clays take up CO 2 into interlayers. Because the nonswelling illitic clay is the major clay mineral in deep subsurface tight rocks, their excess uptake of CO 2 may significantly contribute to CO 2 storage capacity and warrants further in-depth studies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Cell-Level Control for Extending Electric Vehicle Battery Pack Lifetime

A cell-level control approach for electric vehicle battery packs is presented that enhances traditional battery balancing goals to not only provide cell balancing but also achieve significant pack lifetime extension. These goals are achieved by applying a new life-prognostic based control algorithm that biases individual cells differently based on their state of charge, capacity and internal resistance. The proposed life control approach reduces growth in capacity mismatch typically seen in large battery packs over life while optimizing usable energy of the pack. The result is a longer lifetime of the overall pack and a more homogeneous distribution of cell capacities at the end of the first life for vehicle applications. Active cell balancing circuits and associated algorithms are used to accomplish the cell-level life extension objectives. This paper presents details of the cell-level control approach, selection and design of the active balancing system, and low-complexity state-of-charge, capacity, and series-resistance estimation algorithms. A laboratory prototype is used to demonstrate the proposed control approach. The prototype consists of twenty-one 25 Ah Panasonic lithium-Ion NMC battery cells from a commercial electric vehicle and an integrated BMS/DC-DC system that provides 750 W to the vehicle low voltage auxiliary loads.

25 ENERGY STORAGE↗

Integrated Geologic Storage Prefeasibility Study Proximal to Dry Fork Power Station, Powder River Basin, Wyoming

The pre-feasibility study—funded by the Department of Energy CarbonSAFE program (DE-FE0029375)—is centred around Basin Electric’s Dry Fork Station (DFS) in Wyoming’s Powder River Basin. Dry Fork Station, completed in 2011, is a high efficient coal-fired power plant that emits 3.3 million tons of CO2 per annum. The DFS site also host’s the Wyoming Integrated Test Center (ITC) funded by a $15 million investment by the State of Wyoming. The ITC is a public-private partnership test bed for CCS technologies. Geologic storage sites are in immediate vicinity of the DFS providing significant opportunities for co-located source and saline storage. The Powder River Basin (PRB) of Wyoming and Montana, was identified by NETL (2010) as having a “high potential” for commercial-scale carbon sequestration. The basin contains as much as 17,000 feet of sedimentary rock and covers an area of approximately 24,000 square miles. The PRB has a long history of hydrocarbon production and remaining undiscovered reserves. Accumulations and production of hydrocarbons in the basin indicate the presence of reservoir formations with significant pore volumes and impermeable sealing formations. This attribute alone suggests the reservoir and seal characteristics of the formations provide significant opportunities for CO₂ storage in saline reservoirs. Four high quality potential reservoir and sealing complexes have been identified for geologic storage. These formations range in depth from 6,500-9,500 feet underneath DFS including: (1) the Pennsylvanian Minnelusa Formation reservoir and Permian Goose Egg Formation (Opeche Shale) seal; (2) the Jurassic Hulett and Canyon Springs Sandstones of the Sundance Formation sealed by the Late Jurassic Upper Sundance Member and Morrison Formation and (3) the Early Cretaceous Lakota and Dakota, and Muddy Formation reservoirs sealed by the Mowry Shale. The preliminary reservoir characterization results integrate data from petrophysical well logs, core measurements, faults/fractures analysis, artificial penetrations, and published literature to evaluate geologic storage capacity and potential risk, for the Powder River Basin. These reservoir and seal combinations reside within ideal depth constraints and show suitable reservoir and seal characteristics conducive to commercial-scale storage. Specifically, this paper presents 1) high level description of the geologic storage complex 2) a first order risk analysis associated with pre-existing oil and gas wells, and 3) preliminary storage capacity and Area of Review estimates.

Quillinan, Scott↗

U.S. Department of Energy Pacific Region Clean Energy Application Center (PCEAC)

The U.S. Department of Energy Pacific Region Clean Energy Application Center (PCEAC) was formed in 2009 by the U.S. Department of Energy (DOE) and the California Energy Commission to provide education, outreach, and technical support to promote clean energy -- combined heat and power (CHP), district energy, and waste energy recovery (WHP) -- development in the Pacific Region. The region includes California, Nevada, Hawaii, and the Pacific territories. The PCEAC was operated as one of nine regional clean energy application centers, originally established in 2003/2004 as Regional Application Centers for combined heat and power (CHP). Under the Energy Independence and Security Act of 2007, these centers received an expanded charter to also promote district energy and waste energy recovery, where economically and environmentally advantageous. The centers are working in a coordinated fashion to provide objective information on clean energy system technical and economic performance, direct technical assistance for clean energy projects and additional outreach activities to end users, policy, utility, and industry stakeholders. A key goal of the CEACs is to assist the U.S. in achieving the DOE goal to ramp up the implementation of CHP to account for 20% of U.S. generating capacity by 2030, which is estimated at a requirement for an additional 241 GW of installed clean technologies. Additional goals include meeting the Obama Administration goal of 40 GW of new CHP by 2020, key statewide goals such as renewable portfolio standards (RPS) in each state, California’s greenhouse gas emission reduction goals under AB32, and Governor Brown’s “Clean Energy Jobs Plan” goal of 6.5 GW of additional CHP over the next twenty years. The primary partners in the PCEAC are the Department of Civil and Environmental Engineering and the Energy and Resources Group (ERG) at UC Berkeley, the Advanced Power and Energy Program (APEP) at UC Irvine, and the Industrial Assessment Centers (IAC) at San Diego State University and San Francisco State University. The center also worked with a wide range of affiliated groups and industry, government, NGO, and academic stakeholders to conduct a series of CHP education and outreach, project technical support, and related activities for the Pacific region. Key PCEAC tasks have included: - Preparing, organizing and conducting educational seminars on various aspects of CHP - Conducting state baseline assessments for CHP - Working with state energy offices to prepare state CHP action plans - Providing technical support services including CHP/district energy project feasibility screenings - Working with state agencies on CHP policy development - Developing additional CHP educational materials The primary specific services that PCEAC has offered include: - A CHP “information clearinghouse “ website: http://www.pacificcleanenergy.org - Site evaluations and potential projects screenings - Assessment of CHP status, potential, and key issues for each state - Information and training workshops - Policy and regulatory guidance documents and other interactions These services were generally offered at no cost to client groups based on the DOE funding and additional activities supported by the California Energy Commission, except for the in-kind staff resources needed to provide input data and support to PCEAC assessments at host sites. Through these efforts, the PCEAC reached thousands of end-users and directly worked with several dozen organizations and potential CHP “host sites” from 2009-2013. The major activities and outcomes of PCEAC project work are described.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Changes in the Economic Value of Variable Generation at High Penetration Levels: A Pilot Case Study of California

We estimate the long-run economic value of variable renewable generation with increasing penetration using a unique investment and dispatch model that captures long-run investment decisions while also incorporating detailed operational constraints and hourly time resolution over a full year. High time resolution and the incorporation of operational constraints are important for estimating the economic value of variable generation, as is the use of a modeling framework that accommodates new investment decisions. The model is herein applied with a case study that is loosely based on California in 2030. Increasing amounts of wind, photovoltaics (PV), and concentrating solar power (CSP) with and without thermal energy storage (TES) are added one at a time. The marginal economic value of these renewable energy sources is estimated and then decomposed into capacity value, energy value, day-ahead forecast error cost, and ancillary services. The marginal economic value, as defined here, is primarily based on the combination of avoided capital investment cost and avoided variable fuel and operations and maintenance costs from other power plants in the power system. Though the model only captures a subset of the benefits and costs of renewable energy, it nonetheless provides unique insights into how the value of that subset changes with technology and penetration level. Specifically, in this case study implementation of the model, the marginal economic value of all three solar options is found to exceed the value of a flat-block of power (as well as wind energy) by \$20--30/MWh at low penetration levels, largely due to the high capacity value of solar at low penetration. Because the value of CSP per unit of energy is found to be high with or without thermal energy storage at low penetration, we find little apparent incremental value to thermal storage at low solar penetration in the present case study analysis. The marginal economic value of PV and CSP without thermal storage is found to drop considerably (by more than \$70/MWh) as the penetration of solar increases toward 30\percent on an energy basis. This is due primarily to a steep drop in capacity value followed by a decrease in energy value. In contrast, the value of CSP with thermal storage drops much less dramatically as penetration increases. As a result, at solar penetration levels above 10\percent, CSP with thermal storage is found to be considerably more valuable relative to PV and CSP without thermal storage. The marginal economic value of wind is found to be largely driven by energy value, and is lower than solar at low penetration. The marginal economic value of wind drops at a relatively slower rate with penetration, however. As a result, at high penetration, the value of wind can exceed the value of PV and CSP without thermal storage. Though some of these findings may be somewhat unique to the specific case study presented here, the results: (1) highlight the importance of an analysis framework that addresses long-term investment decisions as well as short-term dispatch and operational constraints, (2) can help inform long-term decisions about renewable energy procurement and supporting infrastructure, and (3) point to areas where further research is warranted.

14 SOLAR ENERGY↗

Characterization of the Triassic Newark Basin of New York and New Jersey for geologic storage of carbon dioxide

The Newark Basin is a Triassic-aged rift basin underlying densely populated, industrialized sections of New York, New Jersey and Pennsylvania. The Basin is an elongate half-graben encompassing an area of more than 7,510 square-kilometers (2,900 square-miles), and could represent a key storage component for commercial scale management of carbon dioxide emissions via geologic sequestration. The project team first acquired published reports, surface and subsurface maps, and seismic data, which formed the basis for a three-dimensional model framework for the northern end of the Basin incorporating stratigraphic, hydrologic, and water quality data. Field investigations included drilling, coring, and logging of two stratigraphic test borings in Clarkstown, NY (Exit 14 Tandem Lot Well No. 1), drilled to a depth of 2,099 meters (6,885 feet); and Palisades, NY (Lamont-Doherty Earth Observatory Test Well No. 4) drilled to a depth of 549 meters (1,802 feet). Two two-dimensional seismic reflection data lines arrayed perpendicularly were acquired by Schlumberger/WesternGeco to help characterize the structure and stratigraphy and as part of pre-drilling field screening activities for the deep stratigraphic borehole. A total of 47 meters (155 feet) of continuous whole core was recovered from the Tandem Lot boring from depths of 1,393 meters (4,570 feet) to 1,486 meters (4,877 feet). Twenty-five horizontal rotary cores were collected in mudstones and sandstones in the surface casing hole and fifty-two cores were taken in various lithologies in the deep borehole. Rotary core plugs were analyzed by Weatherford Laboratories for routine and advanced testing. Rotary core plug trim end thin sections were evaluated by the New York State Museum for mineralogical analysis and porosity estimation. Using core samples, Lawrence Berkley National Laboratory designed and completed laboratory experiments and numerical modeling analyses to characterize the dissolution and reaction of carbon dioxide with formation brine and minerals, and resulting effects on injection rate, pressure, effective storage volume, and carbon dioxide migration within a prospective sandstone reservoir. $$Three potential porous and permeable sandstone units were identified in the Passaic Formation at the New York State Thruway Exit 14 location. Potential Flow Unit 1, at a depth of 643 meters (2,110 feet) to 751 meters (2,465 feet); Potential Flow Unit 2 at a depth of 853 meters (2,798 feet) to 1,000 meters (3,280 feet); and Potential Flow Unit 3, at a depth of 1,114 meters (3,655 feet) to 1,294 meters (4,250 feet). Reactive transport simulations of interactions between carbon dioxide, brine and formation minerals were carried out to evaluate changes in formation water chemistry, mineral precipitation and dissolution reactions, and any potential resulting effects on formation permeability. The experimental and modeling analyses suggest that mineral precipitation and dissolution reactions (within the target formation) are not expected to lead to significant changes to the underground hydrologic system over time frames (~30 years) typically relevant for carbon dioxide injection operations. Key findings of this basin characterization study include an estimate of carbon dioxide storage capacity in the Newark Basin. Assuming an average porosity of twelve percent and an aquifer volume of 6.1E+12 meters3, calculated ranges of likely storage capacity range from 1.9 – 20.2 gigatonnes under high temperature (low carbon dioxide density) conditions; and 2.9 – 30.2 gigatonnes under low temperature (low carbon dioxide density) conditions. Intra-basin faulting, geometry of the Palisades Sill, and the presence of altered meta-sediments above and below the Sill, increase potential compartmentalization within the basin. A structural/stratigraphic trap type may occur where porous/permeable sediments are cross-cut by the Palisades Sill. Potential injection intervals are present within the Stockton Formation of the Newark Basin. Additional porous/permeable intervals may be present within sandstones of the Passaic Formation, increasing projected storage capacity. Deeper wedges of strata are likely present in the deeper portions of the basin in southern New York and into northern New Jersey. Abundant mudstones are present in the Passaic, Lockatong, and Stockton Formations. These intervals have the requisite petrophysical properties to form effective primary and secondary containment intervals to industrial-scale sequestration of carbon dioxide in the Newark Basin. Hydro-thermally altered meta-sediments in the region immediately surrounding the top and base of the Palisades Sill is devoid of porosity/permeability and forms an additional effective lateral/vertical sealing cap rock.

58 GEOSCIENCES↗

Developing a Decision Support System for Regional Agricultural Nonpoint Salinity Pollution Management: Application to the San Joaquin River, California

Environmental problems and production losses associated with irrigated agriculture, such as salinity, degradation of receiving waters, such as rivers, and deep percolation of saline water to aquifers, highlight water-quality concerns that require a paradigm shift in resource-management policy. New tools are needed to assist environmental managers in developing sustainable solutions to these problems, given the nonpoint source nature of salt loads to surface water and groundwater from irrigated agriculture. Equity issues arise in distributing responsibility and costs to the generators of this source of pollution. This paper describes an alternative approach to salt regulation and control using the concept of “Real-Time Water Quality management”. The approach relies on a continually updateable WARMF (Watershed Analysis Risk Management Framework) forecasting model to provide daily estimates of salt load assimilative capacity in the San Joaquin River and assessments of compliance with salinity concentration objectives at key monitoring sites on the river. The results of the study showed that the policy combination of well-crafted river salinity objectives by the regulator and the application of an easy-to use and maintain decision support tool by stakeholders have succeeded in minimizing water quality (salinity) exceedances over a 20-year study period.

real-time management economics↗

Simulation of wind and solar energy generation over California with E3SM SCREAM regionally refined models at 3.25 km and 800 m resolutions

This study presents wind and solar power generation estimates derived from the US Department of Energy’s Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM) Regionally Refined Models (RRM) over California at 3.25 km and 800 m horizontal resolutions, using the Python wrapper for the System Advisor Model (PySAM). The resulting wind and solar generation estimates are compared to monthly capacity factors reported to the Energy Information Administration (EIA), High-Resolution Rapid Refresh (HRRR, 3 km resolution) forecast model, and E3SM North American regionally refined model (NARRM, 25 km resolution). We systematically assess the impacts of generation modeling assumptions, meteorological models, and horizontal resolution. Results show that resolution plays a dominant role for wind energy: increasing from 25 to 3.25 km brings qualitative and quantitative improvements, most notably by resolving the phase error in the seasonal cycle found in coarser simulations. However, further refinement to 800 m offers minimal gains. SCREAM performs better than HRRR for solar power generation in single- and dual-axis tracking systems, likely due to more accurate surface radiation. The sensitivity of PySAM to system configuration, particularly for axis-tracking modeling in photovoltaics, is also highlighted. Overall, SCREAM-RRM shows strong potential for high-resolution energy assessments, with future progress depending on more in situ observations and clearer quantification of uncertainties in generation modeling.

Geosciences↗

microbasekaplus.c1

This microbasekaplus datastream is produced by re-writed micorbaseka vap (microbasekaplus) in python under ADI framewrok, and added uncertainties for the microphysics. The original Microbase VAP was developed in 2002. The primary purpose of producing this VAP was to provide the required microphysical values for input to the Broad Band Heating Rate Profiles (BBHRP) VAP in order to generate estimations of radiative heating rates. It served the Radiatively Important Parameters Best Estimate (RIBPE) VAP in the capacity of providing baseline cloud microphysical values as input. Microbase produces cloud microphysical properties based on cloud radar measurements taken at all fixed ARM sites.

54 ENVIRONMENTAL SCIENCES↗

Equity-driven Planning of Distributed Solar PV using Optimal Transport

Typically, distribution system planning processes do not explicitly incorporate energy equity considerations, such as identifying consumers most affected by energy costs and determining how investments in the distribution system can address existing energy burden imbalances. This paper proposes a novel optimal transport (OT)-based method to improve the energy burden distribution of consumers. The approach involves the strategic siting and sizing of solar PV in order to assist customers with high energy burden and improve the overall energy burden distribution of the community. The desired energy burden distribution is defined using the equal distribution equivalent (EDE) concept. The OT-based method is then used to estimate the distributed solar PV capacity to be installed at various locations and the tariffs to be adjusted, all while improving the energy burden distribution and providing valuable insights into distributed generation (DG) planning. The results on IEEE 37 bus test system demonstrate how DG planning, considering EDE and OT, can help reduce the energy burden of low-income consumers. Additionally, the approach also reveals optimal tariff adjustments needed to ensure revenue neutrality for distribution utilities.

Optimal transport, equal distribution equivalent, ↗

80 and 100 Meter Wind Energy Resource Potential for the United States (Poster)

Accurate information about the wind potential in each state is required for federal and state policy initiatives that will expand the use of wind energy in the United States. The National Renewable Energy Laboratory (NREL) and AWS Truewind have collaborated to produce the first comprehensive new state-level assessment of wind resource potential since 1993. The estimates are based onhigh-resolution maps of predicted mean annual wind speeds for the contiguous 48 states developed by AWS Truewind. These maps, at spatial resolution of 200 meters and heights of 60 to 100 meters, were created with a mesoscale-microscale modeling technique and adjusted to reduce errors through a bias-correction procedure involving data from more than 1,000 measurement masts. NREL used the capacityfactor maps to estimate the wind energy potential capacity in megawatts for each state by capacity factor ranges. The purpose of this presentation is to (1) inform state and federal policy makers, regulators, developers, and other stakeholders on the availability of the new wind potential information that may influence development, (2) inform the audience of how the new information was derived,and (3) educate the audience on how the information should be interpreted in developing state and federal policy initiatives.

17 WIND ENERGY↗

Graph-Learning-Assisted State and Event Tracking for Solar-Penetrated Power Grids with Heterogeneous Data Sources

Unlike transmission systems, distribution systems do not typically contain sufficient metering to enable real-time state estimation. The lack of sufficient real-time measurements prohibits accurate and timely monitoring of the state of distribution systems. As a result, control and optimal operation of distribution systems, especially those containing large numbers of renewable generation units are not possible without proper data and information about the current state of the system. The main motivation of this project is to address this shortcoming by developing an approach which provides “predicted” real-time measurements so that they can be used to execute a distribution system state estimator. Thus, the objective of the project is to make the distribution systems fully observable, such that the hosting capacity for solar generation can be accurately estimated, and unnecessary solar curtailments can be avoided. In order to accomplish this goal, the project investigated the use of a grid-model-informed machine learning (ML) tool which integrates heterogeneous data streams obtained from AMI meters, SCADA as well as PMU measurements and created synchronous measurement snapshots for the state estimator (SE); and developed a hybrid robust SE which provides not only accurate state estimates but also real-time feedback for the ML model refinement.

14 SOLAR ENERGY↗

"Hidden" hydrothermal technical potential & technoeconomics: Revealing permeability & fluids with more data

Historical hydrothermal estimates have largely relied on temperature or heat flow estimates ignoring the need for natural flowing fluids. More accurate hydrothermal estimates require some indication of permeability and fluids that naturally exist in the subsurface. This paper describes a novel approach that includes proxies of permeability and fluids in hydrothermal estimates by leveraging the relatively data-rich Great Basin. Specifically, nameplate capacities (megawatts) of operating geothermal plants, negative (0 megawatt) locations and 48 geophysical and geologic features are used to used in eXtreme Gradient Boosting (XGBoost) regression to make hydrothermal capacity predictions. Additionally, this work inputs the XGBoost-based hydrothermal predictions into the Renewable Energy Potential (reV) model to quantify technical capacity, its uncertainty and techno-economics. Compared to historical hydrothermal estimates, these predictions adhere to the 37 operating geothermal plants and negative locations. We present a method for subsampling the negative sites to bring the labels into balance that uses the geologic domain knowledge to proportionally represent negatives. Overall, the distributions of the hydrothermal technical capacity and the site levelized cost of energy are respectively much tighter, lower and more accurate than the previous estimates for the Great Basin, as they include geological and geophysical surrogates for permeability and fluids. Percentile (50th and 90th, median and high estimate, respectively) models provide bookends for these metrics.

13 HYDRO ENERGY↗

A Field Study on Simulation of CO 2 Injection and ECBM Production and Prediction of CO 2 Storage Capacity in Unmineable Coal Seam

CO 2 sequestration into a coal seam project was studied and a numerical model was developed in this paper to simulate the primary and secondary coal bed methane production (CBM/ECBM) and carbon dioxide (CO 2 ) injection. The key geological and reservoir parameters, which are germane to driving enhanced coal bed methane (ECBM) and CO 2 sequestration processes, including cleat permeability, cleat porosity, CH 4 adsorption time, CO 2 adsorption time, CH 4 Langmuir isotherm, CO 2 Langmuir isotherm, and Palmer and Mansoori parameters, have been analyzed within a reasonable range. The model simulation results showed good matches for both CBM/ECBM production and CO 2 injection compared with the field data. The history-matched model was used to estimate the total CO 2 sequestration capacity in the field. The model forecast showed that the total CO 2 injection capacity in the coal seam could be 22,817 tons, which is in agreement with the initial estimations based on the Langmuir isotherm experiment. Total CO 2 injected in the first three years was 2,600 tons, which according to the model has increased methane recovery (due to ECBM) by 6,700 scf/d.

He, Qin↗

Performance Assessment for the E-Area Low-Level Radioactive Waste Disposal Facility at the Savannah River Site: Appendix I

As stated in Section 9.1.2.2, a final inventory of parent radionuclides is projected for every DU at the time of facility operational closure in 2065. These final closure inventories are upper-bound estimates wherein each DU is assumed to reach its activity capacity. Composition vectors based on existing DU inventories are employed to estimate the final compositions of all existing and future DUs. Specifically, (1) the existing DU compositions are assumed to remain constant; (2) future DUs are assigned averaged existing compositions based on appropriately averaged DUs. This information is detailed in Appendix H, Section H.7. In addition, the variability in composition among existing DUs is used to generate log-normal distributions for uncertainty quantification, which is detailed in Section I.1.1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strain measurement based battery testing

A method and system for strain-based estimation of the state of health of a battery, from an initial state to an aged state, is provided. A strain gauge is applied to the battery. A first strain measurement is performed on the battery, using the strain gauge, at a selected charge capacity of the battery and at the initial state of the battery. A second strain measurement is performed on the battery, using the strain gauge, at the selected charge capacity of the battery and at the aged state of the battery. The capacity degradation of the battery is estimated as the difference between the first and second strain measurements divided by the first strain measurement.

25 ENERGY STORAGE↗