Search NASA⌕ Search

SEARCH · Search NASA

Results for “Computational imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

MO-AB-207-03: ACR Update in Nuclear Medicine

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-04: ACR Update in Mammography

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

MO-AB-207-01: ACR Update in CT

A goal of an imaging accreditation program is to ensure adequate image quality, verify appropriate staff qualifications, and to assure patient and personnel safety. Currently, more than 35,000 facilities in 10 modalities have been accredited by the American College of Radiology (ACR), making the ACR program one of the most prolific accreditation options in the U.S. In addition, ACR is one of the accepted accreditations required by some state laws, CMS/MIPPA insurance and others. Familiarity with the ACR accreditation process is therefore essential to clinical diagnostic medical physicists. Maintaining sufficient knowledge of the ACR program must include keeping up-to-date as the various modality requirements are refined to better serve the goals of the program and to accommodate newer technologies and practices. This session consists of presentations from authorities in four ACR accreditation modality programs, including magnetic resonance imaging, computed tomography, nuclear medicine, and mammography. Each speaker will discuss the general components of the modality program and address any recent changes to the requirements. Learning Objectives: To understand the requirements of the ACR MR Accreditation program. The discussion will include accreditation of whole-body general purpose magnets, dedicated extremity systems well as breast MRI accreditation. Anticipated updates to the ACR MRI Quality Control Manual will also be reviewed. To understand the requirements of the ACR CT accreditation program, including updates to the QC manual as well as updates through the FAQ process. To understand the requirements of the ACR nuclear medicine accreditation program, and the role of the physicist in annual equipment surveys and the set up and supervision of the routine QC program. To understand the current ACR MAP Accreditation requirement and present the concepts and structure of the forthcoming ACR Digital Mammography QC Manual and Program.

60 APPLIED LIFE SCIENCES↗

Biochemical Disease-Free Rate and Toxicity for Men Treated With Iodine-125 Prostate Brachytherapy With D{sub 90} {>=}180 Gy

Purpose: Iodine-125 ({sup 125}I) prostate brachytherapy is planned with a prescribed dose of 145 Gy and minimal dose received by 90% of the prostate (D{sub 90}) of 120-125% (174-181 Gy). We examined the clinical outcomes and toxicity profile of men receiving a D{sub 90} (isodose enclosing 90% of the prostate) of {>=}180 Gy. Methods and Materials: Between March 1999 and May 2006, 129 men (17% of our total brachytherapy population) treated with {sup 125}I monotherapy for Stage T1-T2 prostate cancer received a D{sub 90} {>=}180 Gy. Implants were performed using transrectal ultrasonography and fluoroscopic guidance. The 1-month postplan dosimetry used magnetic resonance imaging-computed tomography fusion. The minimal follow-up was 2 years. Toxicity was scored according to the National Cancer Institute Common Terminology Criteria for Adverse Events toxicity scale, version 3. Results: The median patient age was 63 years (range, 50-76), and the pretreatment prostate-specific antigen level was 5.5 ng/mL (range, 0.6-13.5). The Gleason score was {<=}6 in 125 patients and was 7 in 4 patients. The median follow-up period was 40 months (range, 24-111), and the median D{sub 90} was 186 Gy. The median minimal dose received by 30% of the urethra was 203 Gy, and the median rectal volume receiving a minimum of 100% of the prescribed dose was 0.81 cm{sup 3}. Acute Grade 2 genitourinary toxicity was seen in 5.4% and late Grade 2 in 7%. Late urinary retention (Grade 3) was seen in 2 patients (1.5%). Grade 1 rectal bleeding occurred in 9.3% and Grade 2 in 2.3%. On univariate logistic regression analysis, none of the clinical and dosimetric parameters predicted for rectal bleeding. Of 110 men who were potent before treatment, 81% remained potent 5 years after treatment. Three biochemical failures and only one local failure developed. The 5-year biochemical no evidence of disease rate using the 'nadir plus 2' definition was 96.8%. Conclusion: A D{sub 90} of {>=}180 Gy is associated with excellent biochemical disease-free survival and acceptable toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrodynamic and Radiographic Toolbox (HART)

With a multi-lab and university team, we propose to develop new methods for a Hydrodynamic and Radiographic Toolbox (HART) that will enable a fuller and more extensive use of experimental radiographic data towards better characterizing and reducing uncertainties in predictive modeling of weapons performance. We will achieve this by leveraging recent developments in areas of computational imaging, statistical and machine learning, and reduced order modeling of hydrodynamics. In terms of software practices, by partnering with XCP (RISTRA Project) we will conform to recent XCP standards that are inline with modern software practices and standards and ensure compatibility and ease of inter-operability with existing codes. Three new activities under this proposal include (a) the development and use of deep learning-based surrogates to accelerate reconstruction and variational inference of density fields from radiographs of hydrotests, (b) a model-data fusion strategy that couples deep learning-based density reconstructions with fast hydrodynamics simulators to better constrain the reconstruction, and (c) a method for treating asymmetries using techniques adopted from limited view tomography. All three new activities will be based on improved treatment of scatter, noise, beam spot movement, detector blur, and flat fielding in the forward model, and a use of sophisticated priors to aid in the re construction. The improvements to the forward model and improved algorithmic design of the reconstruction when complete will be contained in the iterative reconstruction code SHIVA—a code project that we have recently initiated. The many ways in which machine learning can be used in the reconstruction work will be contained in a code HERMES that has been initiated with DTRA support. For example, the significant levels of acceleration that will likely be achieved by the use of machine learning techniques will permit us (and are required) to quantify uncertainties in density retrievals. Next, the two-way coupling between density reconstruction and model-based simulation of the hydrodynamics will be contained in code EREBUS, and will permit a fuller realization of the potential of the data to constrain the hydrodynamic model and better address issues related to asymmetries in the problem. Finally, we anticipate that the better consistency with physics achieved in our reconstructions will allow them to be used by X-Division more so than today.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Validation of a DIXON-based fat quantification technique for the measurement of visceral fat using a CT-based reference standard

Purpose: The purpose of the study is to determine whether a novel semi-automated DIXON-based fat quantification algorithm can reliably quantify visceral fat using a CT-based reference standard. Methods: This was an IRB-approved retrospective cohort study of 27 subjects who underwent abdominopelvic CT within 7 days of proton density fat fraction (PDFF) mapping on a 1.5T MRI. Cross-sectional visceral fat area per slice (cm{sup 2}) was measured in blinded fashion in each modality at intervertebral disc levels from T12 to L4. CT estimates were obtained using a previously published semi-automated computational image processing system that sums pixels with attenuation − 205 to − 51 HU. MR estimates were obtained using two novel semi-automated DIXON-based fat quantification algorithms that measure visceral fat area by spatially regularizing non-uniform fat-only signal intensity or de-speckling PDFF 2D images and summing pixels with PDFF ≥ 50%. Pearson’s correlations and Bland–Altman analyses were performed. Results: Visceral fat area per slice ranged from 9.2 to 429.8 cm{sup 2} for MR and from 1.6 to 405.5 cm{sup 2} for CT. There was a strong correlation between CT and MR methods in measured visceral fat area across all studied vertebral body levels (r = 0.97; n = 101 observations); the least (r = 0.93) correlation was at T12. Bland–Altman analysis revealed a bias of 31.7 cm{sup 2} (95% CI [− 27.1]–90.4 cm{sup 2}), indicating modestly higher visceral fat assessed by MR. Conclusion: MR- and CT-based visceral fat quantification are highly correlated and have good cross-modality reliability, indicating that visceral fat quantification by either method can yield a stable and reliable biomarker.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An asymmetric hybrid cryptosystem using equal modulus and random decomposition in hybrid transform domain

In this paper, an asymmetric hybrid cryptosystem with coherent superposition, equal modulus and random decomposition in hybrid transform domain is proposed. To further strengthen the security of the cryptosystem, a hyperchaotic system is used as a pixel-swapping procedure. The hybrid transform is generated by utilizing fractional Fourier transform of various orders and Walsh transform. The hyperchaotic framework’s parameters and starting conditions alongside the fractional orders of the fractional Fourier transform extend the key-space and consequently give extra strength to the proposed cryptosystem. The designed cryptosystem has an extended key-space to avoid any brute-force attack and is non-linear in nature. The scheme is validated on gray-scale images. Computer based simulations have been performed to verify the validity and the performance of the proposed cryptosystem against different types of attacks. Results demonstrate that the proposed cryptosystem not only offers higher protection against noise attacks but is also invulnerable to special attack.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging Approaches for Coronary Artery Anomalies: Purpose and Techniques

Purpose of Review: Comprehensive discussion of alternative techniques in imaging coronary artery anomalies (CAAs) in different diagnostic scenarios. Recent Findings: At primary screening, intramural course essentially correlates with stenosis and clinical repercussion in some types of CAAs. Potential clinical aims in imaging patients with CAAs may be primary screening, severity evaluation, preoperative planning, and postoperative follow-up. Appropriate techniques are echocardiography, magnetic resonance imaging, computed tomography angiography, and intravascular ultrasound (IVUS). Rarely, IVUS may be needed in patients with potentially serious CAAs and has unique advantages and limitations. IVUS data are essential for in-depth knowledge of mechanisms of coronary dysfunction (exercise-related dynamic stenosis of variable severity) and for indicating interventional treatment. Summary: In adolescents or adults, intramural course of an anomalous coronary artery is the only important feature accompanied by stenosis of potential severity and is especially relevant in patients with a high-risk status (elite sport athletes, military recruits).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser-assisted cell removing (LACR) technology contributes to the purification process of the undifferentiated cell fraction during pluripotent stem cell culture

Highlights: • Purification of undifferentiated cells is a critical step in stem cell culture. • We developed an automated laser-assisted cell removing technology. • This system successfully removed contaminated/differentiated cells in human iPS cell culture. Purification of undifferentiated cells by removing differentiated parts is an essential step in pluripotent stem cell culture. This process has been traditionally performed manually using a fine glass capillary or plastic tip under a microscope, or by culturing in a selective medium supplemented with anti-differentiation inhibitors. However, there are several inevitable problems associated with these methods, such as contamination or biological side-effects. Here, we developed a laser-assisted cell removing (LACR) technology that enables precise, fast, and contact-less cell removal. Using LACR combined with computational image recognition/identification-discriminating technology, we achieved automatic cell purification (A-LACR). Practicability of A-LACR was evaluated by two demonstrations: selective removal of trophoblast stem (TS) cells from human iPS and TS cell co-cultures, and purification of undifferentiated iPS cells by targeting differentiated cells that spontaneously developed. Our results suggested that LACR technology is a novel approach for stem cell processing in regenerative medicine.

60 APPLIED LIFE SCIENCES↗

Viewing is understanding: Graphite microstructure effects on infiltrated molten salt distribution revealed by 3D neutron tomography

Molten salt infiltration in the pore network of nuclear graphite may cause unwanted changes to graphite's local structure and mechanical and thermal properties. A detailed and comprehensive understanding of molten salt intrusion (distribution across sample cross section and penetration depth) is needed to assess its effects. Here, in this work, we report on an improved methodology for the use of neutron imaging (computed tomography) to evaluate salt penetration and distribution of a wide range of graphite grades with diverse microstructures. Neutron tomography data were acquired on the same graphite sample before and after salt intrusion; the 3D reconstructed volumes were digitally co-registered and subtracted. The difference in neutron attenuation coefficient represents direct visualization of FLiNaK (LiF–NaF–KF) salt distribution in the salt-impregnated graphite samples. This improved methodology was applied to investigate the effect of exposure times (12 h and 336 h) and of graphite microstructure when exposed to FLiNaK at 750 °C and 3 bar (gauge) pressure, starting from flowing argon at near atmospheric pressure. The results show that medium-grained and fine-grained graphites evolve to equilibrium at significantly different rates: fast salt uptake in medium-grained graphites produces salt deposits throughout the volume of graphite specimens, whereas salt infiltration in fine-grained graphites is much slower and limited to exposed surfaces.

FLiNaK infiltration↗

Microstructures in the 6060 aluminium alloy after various severe plastic deformation treatments

This paper presents the results concerning the microstructural refinement of the industrial 6060 aluminium alloy processed by severe plastic deformation (SPD). The high level of plastic deformation was achieved using the three methods: hydrostatic extrusion (HE), equal channel angular extrusion (ECAE) and extrusion torsion (ET), which differed in the dynamics of the loading, intensity and homogeneity of the plastic strain field. Microstructure analyses were performed before and after SPD deformation using a transmission (TEM) and a scanning electron microscope (SEM). The refined microstructures were examined qualitatively and quantitatively by the stereological methods and computer image analyses. The microstructure of the industrial 6060 aluminium alloy after deformation was characterized by an average grain size of about 0.4 {mu}m. The results show that the precipitates strongly affect the degree of refinement and the mechanism of microstructural transformations. During the SPD, the second phase particles break apart and homogenize. The HE method generates the largest increase of the volume fraction of the small primary particles. Moreover, the HE process is most effective in reducing the primary particle size. During HE and ECAE processes the second phase precipitates dissolve partially and change their shape. - Research Highlights: {yields} SPD results in a significant increase in the density of the small primary particles. {yields} SPD homogenizes the particle size distribution. {yields} HE and ECAE processes bring nano-grains in the vicinity of the primary particles. {yields} HE and ECAE processing results in the {beta}' precipitates partial dissolutions. {yields} During HE and ECAE processes the {beta}' particles change their shape.

36 MATERIALS SCIENCE↗

Advances in relaxation and memory effects of magnetic nanoparticles for biomedical applications

Functionalized magnetic nanoparticles are pivotal in magnetic resonance imaging, computed tomography, controlled drug delivery, and hyperthermia treatments due to their exceptional magnetic relaxation and functional properties. The magnetic core composition and structure significantly affects the complex magnetic properties of these nanoparticles necessitating a thorough examination of magnetism fundamentals related to these systems. One important aspect is the ability of magnetic nanoparticles to retain previous magnetic state configurations known as memory effect, primarily governed by domain structure and magnetic anisotropy. Despite its relevance to advanced applications, comprehensive studies on magnetic relaxation and memory effects remain limited. Here, the present review aims to bridge this gap by investigating relaxation mechanisms, synthesis strategies, and applications, fostering further innovation. It investigates the memory effects and their dependence on particle composition and morphology along with key synthesis techniques for large-scale production in industrial adoption. Structured into focused sections on magnetic properties and their influence on biomedical and technological applications, this review provides essential insights into memory effects, magneto-relaxation mechanisms, influencing factors, and both experimental and theoretical methodologies. It also delves into computational modelling and AI-driven design, which are revolutionizing the prediction, discovery, and optimization of materials with tailored properties.

36 MATERIALS SCIENCE↗

Receptor tyrosine kinase inhibition causes simultaneous bone loss and excess bone formation within growing bone in rats

During postnatal skeletal growth, adaptation to mechanical loading leads to cellular activities at the growth plate. It has recently become evident that bone forming and bone resorbing cells are affected by the receptor tyrosine kinase (RTK) inhibitor imatinib mesylate (STI571, Gleevec (registered)) . Imatinib targets PDGF, ABL-related gene, c-Abl, c-Kit and c-Fms receptors, many of which have multiple functions in the bone microenvironment. We therefore studied the effects of imatinib in growing bone. Young rats were exposed to imatinib (150 mg/kg on postnatal days 5-7, or 100 mg/kg on postnatal days 5-13), and the effects of RTK inhibition on bone physiology were studied after 8 and 70 days (3-day treatment), or after 14 days (9-day treatment). X-ray imaging, computer tomography, histomorphometry, RNA analysis and immunohistochemistry were used to evaluate bone modeling and remodeling in vivo. Imatinib treatment eliminated osteoclasts from the metaphyseal osteochondral junction at 8 and 14 days. This led to a resorption arrest at the growth plate, but also increased bone apposition by osteoblasts, thus resulting in local osteopetrosis at the osteochondral junction. The impaired bone remodelation observed on day 8 remained significant until adulthood. Within the same bone, increased osteoclast activity, leading to bone loss, was observed at distal bone trabeculae on days 8 and 14. Peripheral quantitative computer tomography (pQCT) and micro-CT analysis confirmed that, at the osteochondral junction, imatinib shifted the balance from bone resorption towards bone formation, thereby altering bone modeling. At distal trabecular bone, in turn, the balance was turned towards bone resorption, leading to bone loss. - Research Highlights: > 3-Day imatinib treatment. > Causes growth plate anomalies in young rats. > Causes biomechanical changes and significant bone loss at distal trabecular bone. > Results in loss of osteoclasts at osteochondral junction.

60 APPLIED LIFE SCIENCES↗

Three-Dimensional Nanostructures Formed by Single Step, Two-Photon Exposures through Elastomeric Penrose Quasicrystal Phase Masks

We describe the fabrication of unusual classes of three-dimensional (3D) nanostructures using single step, two-photon exposures of photopolymers through elastomeric phase masks with 5-fold, Penrose quasicrystalline layouts. Confocal imaging, computational studies, and 3D reconstructions reveal the essential aspects of the flow of light through these quasicrystal masks. Here, the resulting nanostructures show interesting features, including quasicrystalline layouts in planes parallel to the sample surfaces, with completely aperiodic variations through their depths, consistent with the optics. Spectroscopic measurements of transmission and reflection provide additional insights.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Anticipating decoherence in quantum systems

Large-scale quantum technologies require coherence across distant nodes, necessitating indistinguishable quantum states. However, environmental disorder, including dephasing, spectral diffusion, and spin-bath interactions, undermines coherence. Using statistical methods, we uncover correlations in decoherence channels induced by slowly varying environments. Spectral diffusion serves as a representative demonstration case that can be extended to other remote, disordered systems such as spins in nitrogen-vacancy centers and quantum-dot spin qubits, as well as flux noise in superconducting qubits. In this work, we employ replica-theory-inspired trajectory analysis to reveal predictable temporal structures in decoherence dynamics, and validate these through an anticipatory systems framework with internal prediction of unseen spectral dynamics in multiple quantum systems, showing that this framework could, if implemented, reduce spectral shift by average factors of approximately 2 to 19, depending on emitter stability, thereby enabling enhanced coherence and multi-node synchronization for scalable quantum communication, computation, imaging, and sensing.

Maan, Pranshu [Purdue University]↗

Ptychography at all wavelengths

Ptychography is a computational imaging technique that operates across multiple wavelength regimes, from electron (picometres) to X-ray (~0.1 nm), extreme ultraviolet (~10 nm) and visible light (micrometres). By reconstructing both amplitude and phase from diffraction patterns, ptychography enables high-resolution, quantitative imaging without conventional limitations imposed by lens-based optics. Ptychography has enabled advances across a range of scales: achieving deep-sub-angstrom resolution with electron microscopy, becoming an indispensable tool at X-ray synchrotron facilities worldwide and overcoming the trade-offs between resolution and field-of-view in optical imaging. This Primer provides a unified treatment of ptychography across these wavelength regimes. First, we discuss theoretical foundations, reconstruction algorithms, experimental considerations and wavelength-specific challenges. We then give examples of raw and processed data from various configurations and wavelengths. Next, we highlight key applications of ptychography in life sciences, materials science and industry. We also discuss data standards, open-source software implementations and best practices for ensuring reproducibility across different wavelength regimes. Finally, we consider limitations and future opportunities for ptychography. Together with accompanying datasets and code implementations, this Primer aims to serve newcomers and experienced practitioners in the field, facilitating broader adoption of ptychography across different disciplines.

47 OTHER INSTRUMENTATION↗

Ultra-Fine Grain Structures Of Model Al-Mg-Si Alloys Produced By Hydrostatic Extrusion

Microstructure and mechanical properties were studied in model Al-Mg-Si alloys (Al-1 % Mg-0.8% Si and Al-0.5% Mg-0.3% Si-wt %) deformed by hydrostatic extrusion (HE) to strains of 1.4 and 3.8. In these alloys the different percentage of two hardening second-phase precipitates (Mg{sub 2}Si and Si) were observed. The microstructure was characterized by transmission electron microscopy and optical microscopy. The microstructure of the alloys in the initial state was built of coarse grains of an average diameter of {approx}30 rim. The refined microstructure was examined qualitatively and quantitatively using the stereological method and a computer image analysis. The deformation-processed structures evolved very rapidly, forming ultrafine grained (UFG) materials with grains of about 0.4 {mu}m. In addition, the grain refinement in the HE-treated materials has a substantial effect on their properties, such as the mechanical strength and micro-hardness which increase significantly. It has been found that, after {epsilon} = 3.8 in the Al-1% Mg-0.8% Si alloy, the micro-hardness increases approximately twofold. The yield stress is more than four times higher in the UFG alloys, in comparison to the initial state. Similar results were identified in the Al-0.5% Mg-0.3% Si. This is due to the very rapid refinement of the microstructure during the deformation and presence of second-phase particles.

36 MATERIALS SCIENCE↗