Nonlinear Model Predictive Control using Decoupled A-B Net Formulation for Carbon Capture Systems – Comparison with Algorithmic Differentiation Approach
Presented by NETL at 2018 American Control Conference, 6/18
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Presented by NETL at 2018 American Control Conference, 6/18
Monitoring the operation of sodium purification system is essential for efficient operation of sodium fast reactors. In this work, a heat transfer model has been developed for monitoring the plugging meter and cold trap systems at the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The model of the purification system was developed by treating the respective aspects of the cold trap purification loop and plugging meter diagnostic loop as two separate control volumes using information from the METL piping and instrumentation diagram (P&ID). A model predictive controller was designed using first order differential equations with the specified boundary conditions. The system behavior was studied with a tuned optimized procedure using the internal cold trap temperature and plugging meter outlet temperature as control variables, and the air blower temperature as an independent variable respectively. Results of computer simulations obtained in this study compared favorably with experimental data showing very good reference tracking response with negligible overshoot as both plugging meter and cold trap physical models approach the setpoint.
We explore a variant of the Φ 6 model originally proposed in Phys. Rev.D 12 (1975) 1606 as a prototypical, so-called, “bag” model in which domain walls play the role of quarks within hadrons. We examine the steady state of the model, namely an apparent bound state of two kink structures. We explore its linearization, and we find that, as a function of a parameter controlling the curvature of the potential, an effectively arbitrary number of internal modes may arise in the point spectrum of the linearization about the domain wall profile. We explore some of the key characteristics of kink-antikink collisions, such as the critical velocity and the multi-bounce windows, and how they depend on the principal parameter of the model. We find that the critical velocity exhibits a non-monotonic dependence on the parameter controlling the curvature of the potential. For the multi-bounce windows, we find that their range and complexity decrease as the relevant parameter decreases (and as the number of internal modes in the model increases). We use a modified collective coordinates method [in the spirit of recent works such as Phys. Rev.D 94 (2016) 085008] in order to capture the relevant phenomenology in a semi-analytical manner.
In the transactive energy (TE) paradigm, the devices of participative consumers, or prosumers, may be aggregated and employed to drive operational objectives at the network level. Home heating, ventilation and air-conditioning (HVAC) systems in particular are well-suited to modulate their behaviours based on both home thermal flexibility and requests from the utility grid. This paper develops a robust, hierarchical power dispatch scheme in the context of a residential distribution network. The formulation couples a unique, multiphase linear distribution optimal power flow (OPF) at the upper level with model predictive control (MPC)-based HVAC fleet controllers at the lower level. The proposed approach is tested on nearly 2000 homes with a three-phase distribution network in an intraday market setting, where two major applications are explored and analysed.
Purpose: To fit the individual biochemical recurrence-free survival (bRFS) data from patients treated with postprostatectomy radiation therapy (RT) with a comprehensive tumor control probability (TCP) model. Methods and Materials: Considering pre-RT prostate-specific antigen (PSA) as a surrogate of the number of clonogens, bRFS may be expressed as a function of dose-per-fraction–dependent radiosensitivity (α{sub eff}), the number of clonogens for pre-RT PSA = 1 ng/mL (C), and the fraction of patients who relapse because of clonogens outside the treated volume (K), assumed to depend (linearly or exponentially) on pre-RT PSA and Gleason score (GS). Data from 894 node-negative, ≥pT2, pN0 hormone-naive patients treated with adjuvant (n=331) or salvage (n=563) intent were available: 5-year bRFS data were fitted grouping patients according to GS (<7:392, =7:383, >7:119). Results: The median follow-up time, pre-RT PSA, and dose were 72 months, 0.25 ng/mL, and 66.6 Gy (range 59.4-77.4 Gy), respectively. The best-fit values were 0.23 to 0.26 Gy{sup −1} and 10{sup 7} for α{sub eff} and C for the model considering a linear dependence between K and PSA. Calibration plots showed good agreement between expected and observed incidences (slope: 0.90-0.93) and moderately high discriminative power (area under the curve [AUC]: 0.68-0.69). Cross-validation showed satisfactory results (average AUCs in the training/validation groups: 0.66-0.70). The resulting dose-effect curves strongly depend on pre-RT PSA and GS. bRFS rapidly decreases with PSA: the maximum obtainable bRFS (defined as 95% of the maximum) declined by about 2.7% and 4.5% for each increment of 0.1 ng/mL for GS <7 and ≥7, respectively. Conclusions: Individual data were fitted by a TCP model, and the resulting best-fit parameters were radiobiologically consistent. The model suggests that relapses frequently result from clonogens outside the irradiated volume, supporting the choice of lymph-node irradiation, systemic therapy, or both for specific subgroups (GS <7: PSA >0.8-1.0 ng/mL; GS ≥7: PSA >0.3 ng/mL). Early RT should be preferred over delayed RT; the detrimental effect of PSA increase can never be fully compensated by increasing the dose, especially for patients with GS ≥7.
With the increasing demand for energy in day-today life, the need for integrating renewable energy is growing. In this paper, we take a step in addressing the issue by employing solar photovoltaic (PV) energy to maintain indoor temperatures in buildings. The objective we aim to meet is to use as much of the generated PV energy as possible while maintaining the indoor comfort temperatures. We set this objective in order to reduce wastage of renewable energy and cut down the need for storage devices. We formulate a thermal model of the building HVAC system and employ the model-free control (MFC) technique to achieve the defined objective. Although recently introduced, MFC has shown promising results in various domains and it is more appealing due to its light computational complexity. Furthermore, we analyze the relationship between the generated PV energy and the total energy consumption of the buildings. The results show that the aforementioned relationship is linear in nature as the number of buildings increases.
District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.
We introduce a continuum modeling method to approximate a class of large wireless networks by nonlinear partial differential equations (PDEs). This method is based on the convergence of a sequence of underlying Markov chains of the network indexed by N , the number of nodes in the network. As N goes to infinity, the sequence converges to a continuum limit, which is the solution of a certain nonlinear PDE. We first describe PDE models for networks with uniformly located nodes and then generalize to networks with nonuniformly located, and possibly mobile, nodes. Based on the PDE models, we develop a method to control the transmissions in nonuniform networks so that the continuum limit is invariant under perturbations in node locations. This enables the networks to maintain stable global characteristics in the presence of varying node locations.
Purpose: A fully heterogeneous population averaged mechanistic tumor control probability (TCP) model is appropriate for the analysis of external beam radiotherapy (EBRT). This has been accomplished for EBRT photon treatment of intermediate-risk prostate cancer. Extending the TCP model for low and high-risk patients would be beneficial in terms of overall decision making. Furthermore, different radiation treatment modalities such as protons and carbon-ions are becoming increasingly available. Consequently, there is a need for a complete TCP model. Methods: A TCP model was fitted and validated to a primary endpoint of 5-year biological no evidence of disease clinical outcome data obtained from a review of the literature for low, intermediate, and high-risk prostate cancer patients (5218 patients fitted, 1088 patients validated), treated by photons, protons, or carbon-ions. The review followed the preferred reporting item for systematic reviews and meta-analyses statement. Treatment regimens include standard fractionation and hypofractionation treatments. Residual analysis and goodness of fit statistics were applied. Results: The TCP model achieves a good level of fit overall, linear regression results in a p-value of <0.000 01 with an adjusted-weighted-R{sup 2} value of 0.77 and a weighted root mean squared error (wRMSE) of 1.2%, to the fitted clinical outcome data. Validation of the model utilizing three independent datasets obtained from the literature resulted in an adjusted-weighted-R{sup 2} value of 0.78 and a wRMSE of less than 1.8%, to the validation clinical outcome data. The weighted mean absolute residual across the entire dataset is found to be 5.4%. Conclusions: This TCP model fitted and validated to clinical outcome data, appears to be an appropriate model for the inclusion of all clinical prostate cancer risk categories, and allows evaluation of current EBRT modalities with regard to tumor control prediction.
Lean-burn gasoline engines have demonstrated 10–20% engine efficiency gain over stoichiometric engines and are widely considered as a promising technology for meeting the 54.5 miles-per-gallon (mpg) Corporate Average Fuel Economy standard by 2025. Nevertheless, NOx emissions control for lean-burn gasoline for meeting the stringent EPA Tier 3 emission standards has been one of the main challenges towards the commercialization of highly-efficient lean-burn gasoline engines in the United States. Passive selective catalytic reduction (SCR) systems, which consist of a three-way catalyst and SCR, have demonstrated great potentials of effectively reducing NOx emissions for lean gasoline engines but may cause significant fuel penalty due to ammonia generation via rich engine combustion. The purpose of this study is to develop a model-predictive control (MPC) scheme for a lean-burn gasoline engine coupled with a passive SCR system to minimize the fuel penalty associated with passive SCR operation while satisfying stringent NOx and NH3 emissions requirements. Simulation results demonstrate that the MPC-based control can reduce the fuel penalty by 47.7% in a simulated US06 cycle and 32.0% in a simulated UDDS cycle, compared to the baseline control, while achieving over 96% deNOx efficiency and less than 15 ppm tailpipe ammonia slip. The proposed MPC control can potentially enable high engine efficiency gain for highly-efficient lean-burn gasoline engine while meeting the stringent EPA Tier 3 emission standards.
Not Available
Control design for an autonomous wheel loader requires a high-fidelity and low-order dynamics model. The objective of order reduction is to decrease the number of states in the model while maintaining performance comparable to the original model. Of all the power components in a wheel loader, the model order reduction for steering and working hydraulic systems is most demanding due to its nonlinear and stiff dynamical nature. This paper describes a physics-inspired model order reduction method that can reduce the model order by close to thirty percent. It is achieved by discarding orders with fast dynamics and consolidating multiple states into less new states. Furthermore, this method can also be extended to other types of off-road vehicles such as excavators, bulldozers, etc. Simulation results demonstrate that the reduced-order model exhibits very similar performance to the full-order model under typical operating conditions of wheel loaders, with an output error of less than six percent.
This research develops a novel hybrid fuel heat pump system for space heating of residential and small commercial buildings with built-in optimization and control. Whereas conventional dual fuel systems either run on gas or electricity at any given moment, the proposed seamlessly fuel flexible heat pump (SFFHP) simultaneously consumes gas and electricity and continuously optimizes the proportion of each. The building air flows across the heat pump condenser first and then flows across the furnace coil, and this reduces the heat pump temperature lift. The SFFHP delivers energy savings by allowing each subsystem (gas furnace and electric heat pump) to operate where it performs best to improve energy efficiency, minimize energy cost, and minimize carbon footprint. The capacities of the electric heat pump and gas furnace are continuously adjusted based on ambient conditions, utility price signals, and marginal grid emission signals. An optimal model predictive control strategy was developed with the goal of minimizing utility cost and minimizing CO2 emission. Two case studies were conducted to simulate the performance of SFFHP during the heating season in Chicago and Los Angeles, respectively. Compared with a conventional electric heat pump, SFFHP yields 33% utility cost reduction and 49% CO2 emission reduction in Chicago. Similarly, it achieves 23% utility cost reduction and 17% CO2 emission reduction in Los Angeles. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. Due to the hybrid fuel nature of this novel equipment, user comfort will always be maintained. The fuel flexibility makes it an attractive option for demand response programs.
Not Available
The simulator is an isothermal, three-dimensional, four-phase, compositional, equation-of–state (EOS) simulator. We have named the simulator UTDOE-CO2 capable of simulating various recovery processes (i.e., primary, secondary waterflooding, and miscible and immiscible gas flooding). We include both the Peng-Robinson EOS and the Redlich-Kwong EOS models. A Gibbs stability test is also included in the model to perform a phase identification test to consistently label each phase for subsequent property calculations such as relative permeability, viscosity, density, interfacial tension, and capillary pressure. Our time step strategy is based on an IMPEC-type method (implicit pressure and explicit concentration). The gridblock pressure is solved first using the explicit dating of saturation-dependent terms. Subsequently, the material balance equations are solved explicitly for the total concentration of each component. The physical dispersion term is also included in the governing equations. The simulator includes (1) several foam model(s) for gas mobility control, (2) compositional relative permeability models with the hysteresis option, (3) corner point grid and several efficient solvers, (4) geomechanics module to compute stress field as the result of CO 2 injection/production, (5) the format of commercial visualization software, S3graf from Science-soft Ltd., was implemented for user friendly visualization of the simulation results. All tasks are completed and the simulator was fully tested and delivered to the DOE office including a user’s guide and several input files and the executable for Windows Pcs. We have published several SPE papers, presented several posters, and one MS thesis is completed (V. Pudugramam, 2013) resulting from this DOE funded project.
This project develops the dynamic modeling of hydro plants and wind generation in Sitka, Alaska. A dynamic penetration of renewables was evaluated under various conditions. The impact of altering hydro generation control to synchronous condenser control was evaluated. While the existing hydro generations are sufficient to address voltage instability, a detailed study of the active-reactive capability limits of hydro generation operation should be conducted to uptake at various wind penetration levels.
Closed-circuit reverse osmosis (CCRO) offers a flexible and energy-efficient alternative to conventional reverse osmosis by operating in a semi-batch mode that recycles brine, enabling higher recovery rates and reduced specific energy consumption (SEC). However, developing accurate, system-level dynamic models for CCRO remains challenging due to its nonlinear, multi-phase operation and sensitivity to variable feed water conditions. Traditional modeling approaches, such as NARMAX (nonlinear autoregressive moving average with exogenous inputs), often struggle to generalize across varying inlet feed concentrations, necessitating frequent parameter re-estimation and limiting their utility for real-time control applications. To address these limitations, we developed a long short-term memory (LSTM) neural network model trained on an extensive experimental data set from a CCRO pilot plant. The model accepts three inputs, feed flow rate, recirculation flow rate, and initial feed conductivity, and predicts three key outputs: reject conductivity, feed pump power draw, and recirculation pump power draw. We validated the LSTM model against experimental data, demonstrating its ability to distinguish between different feed conductivities and adapt to variable flow rates. Subsequently, we incorporated the LSTM model within a nonlinear model predictive control (MPC) scheme and conducted closed-loop simulations to optimize the integrated SEC (iSEC). In conclusion, the results project up to a 6% reduction in iSEC by using MPC to optimize performance over the entire experiment duration, without requiring any random excitation for data collection or parameter re-estimation.
Yaw control has proven to be promising in alleviating the wake effects that plague the efficiency of wind farms. In this work, the actuator line modeling (ALM) method is adopted to simulate the flows over two tandem turbines distanced by 3–7 rotor diameters, with the yaw angle of the upstream rotor varying from γ 1 = 0° to 50°. The aim is to provide a comprehensive aerodynamic characterization of this simple wind farm under yaw misalignment control. With increasing yaw angle, the power generated by the downstream rotor increases, compensating the power loss in the upstream rotor, and resulting in significantly higher total power of the two turbines than that without yaw control. The maximum power output is achieved as the upstream wake of the yawed rotor is redirected away from the downstream rotor plane. Behind the downstream rotor, the secondary steering phenomenon is observed, where the wake is also redirected from the centerline. The use of the actuator line model also reveal unsteady aerodynamic characteristics that cannot be captured by lower-fidelity models. For the upstream rotor, the yaw misalignment results in time-varying change in the local angle of attack on the blade, giving rise to unsteady loading. The downstream rotor is partially submerged in the deflected wake incurred by the yawed upstream rotor. As the blade revolves into and out of the wake deficit, the blade experiences cyclic loading, leading to even stronger fluctuations in the aerodynamic loads than the upstream rotor. These analysis provides a comprehensive understanding of the yaw control effects on the two tandem rotors from the perspectives of aerodynamic performance, wake profiles, and unsteady characteristics. In conclusion, the insights gained from the present study can aid the design of collective yaw control strategies of wind farms, and lay the foundation for assessing the fatigue damage associated with yaw misalignment.