Search NASA⌕ Search

SEARCH · Search NASA

Results for “Conversion System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Design and Analysis for a Floating Oscillating Surge Wave Energy Converter: Preprint

This paper presents a recent study on the design and analysis of an oscillating surge wave energy converter. A successful wave energy conversion design requires the balance between the design performance and cost. The cost of energy is often used as the metric to judge the design of the wave energy conversion system. It is often determined based on the device power performance, the cost for manufacturing, deployment, operation and maintenance, as well as the effort to ensure the environmental compliance. The objective of this study is to demonstrate the importance of a cost driven design strategy and how it can affect a WEC design. Three oscillating surge wave energy converter (OSWEC) designs were used as the example. The power generation performance of the design was modeled using a time-domain numerical simulation tool, and the mass properties of the design were determined based on a simple structure analysis. The results of those power performance simulations, the structure analysis and a simple economic assessment were then used to determine the cost-efficiency of selected OSWEC designs. Finally, a discussion on the environmental barrier, integrated design strategy and the key areas that need further investigation is also presented.

17 WIND ENERGY↗

SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis is inventor and runs a consulting company for radiochromic films.

07 ISOTOPE AND RADIATION SOURCES↗

Aprepro - Algebraic Preprocessor

Aprepro is an algebraic preprocessor that reads a file containing both general text and algebraic, string, or conditional expressions. It interprets the expressions and outputs them to the output file along with the general text. Aprepro contains several mathematical functions, string functions, and flow control constructs. In addition, functions are included that, with some additional files, implement a units conversion system and a material database lookup system.

Sjaardema, Gregory↗

The future of ship engines: Renewable fuels and enabling technologies for decarbonization

Shipping is one of the most efficient transportation modes for moving freight globally. International regulations concerning decarbonization and emission reduction goals drive rapid innovations to meet the 2030 and 2050 greenhouse gas reduction targets. The internal combustion engines used for marine vessels are among the most efficient energy conversion systems. Internal combustion engines dominate the propulsion system architectures for marine shipping, and current marine engines will continue to serve for several decades. However, to meet the aggressive goals of low-carbon-intensity shipping, there is an impetus for further efficiency improvement and achieving net zero greenhouse gas emissions. These factors drive the advancements in engine technologies, low-carbon fuels and fueling infrastructure, and emissions control systems. This editorial presents a perspective on the future of ship engines and the role of low-life cycle-carbon-fuels in decarbonizing the marine shipping sector. A selection of zero-carbon, net-zero carbon, and low-lifecycle-carbon-fuels are reviewed. This work focuses on the opportunities and challenges of displacing distillate fossil fuels for decarbonizing marine shipping. In conclusion, enabling technologies such as next-generation air handling, fuel injection systems, and advanced combustion modes are discussed in the context of their role in the future of low-CO 2 intensity shipping.

33 ADVANCED PROPULSION SYSTEMS↗

Assessment of First Wall and Blanket Options with the Use of Liquid Breeder

As candidate blanket concepts for a U.S. advanced reactor power plant design, with consideration of the time frame for ITER development, we assessed first wall and blanket design concepts based on the use of reduced activation ferritic steel as structural material and liquid breeder as the coolant and tritium breeder. The liquid breeder choice includes the conventional molten salt Li 2 BeF 4 and the low melting point molten salts such as LiBeF 3 and LiNaBeF 4 (FLiNaBe). Both self-cooled and dual coolant molten salt options were evaluated. We have also included the dual coolant leadeutectic Pb-17Li design in our assessment. We take advantage of the molten salt low electrical and thermal conductivity to minimize impacts from the MHD effect and the heat losses from the breeder to the actively cooled steel structure. For the Pb-17Li breeder we employ flow channel inserts of SiC f /SiC composite with low electrical and thermal conductivity to perform respective insulation functions. We performed preliminary assessments of these design options in the areas of neutronics, thermal-hydraulics, safety, and power conversion system. Status of the R&D items of selected high performance blanket concepts is reported. Results from this study will form the technical basis for the formulation of the U.S. ITER test module program and corresponding test plan.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Stress testing on silicon carbide electronic devices for prognostics and health management.

Power conversion systems for energy storage and other distributed energy resource applications are among the drivers of the important role that power electronics plays in providing reliable electricity. Wide band gap semiconductors such as silicon carbide (SiC) and gallium nitride (GaN) will help increase the performance and efficiency of power electronic equipment while condition monitoring (CM) and prognostics and health management (PHM) will increase the operational availability of the equipment and thereby make it more cost effective. Voltage and/or temperature stress testing were performed on a number of SiC devices in order to accelerate failure modes and to identify measureable shifts in electrical characteristics which may provide early indication of those failures. Those shifts can be interpreted and modeled to provide prognostic signatures for use in CM and/or PHM. Such experiments will also lead to a deeper understanding of basic device physics and the degradation mechanisms behind failure.

42 ENGINEERING↗

SCWR Once-Through Calculations for Transmutation and Cross Sections

It is the purpose of this report to document the calculation of (1) the isotopic evolution and of (2) the 1-group cross sections as a function of burnup of the reference Super Critical Water Reactor (SCWR), in a format suitable for the Fuel Cycle Option Campaign Transmutation Data Library. The reference SCWR design was chosen to be that described in [McDonald, 2005]. Super Critical Water Reactors (SCWR) are intended to operate with super-critical water (i.e. H2O at a pressure above 22 MPa and a temperature above 373oC) as a cooling – and possibly also moderating – fluid. The main mission of the SCWR is to generate lower cost electricity, as compared to current standard Light Water Reactors (LWR). Because of the high operating pressure and temperature, SCWR feature a substantially higher thermal conversion efficiency than standard LWR – i.e. about 45% versus 33%, mostly due to an increase in the exit water temperature from ~300oC to ~500oC – potentially resulting in a lower cost of generated electricity. The coolant remains single phase throughout the reactor and the energy conversion system, thus eliminating the need for pressurizers, steam generators, steam separators and dryers, further potentially reducing the reactor construction capital cost. The SCWR concept presented here is based on existing LWR technology and on a large number of existing fossil-fired supercritical boilers. However, it was concluded in [McDonald, 2005], that: “Based on the results of this study, it appears that the reference SCWR design is not feasible.” This conclusion appears based on the strong sensitivity of the design to small deviations in nominal conditions leading to small effects having a potentially large impact on the peak cladding temperature of some fuel rods. “This was considered a major feasibility issue for the SCWR” [McDonald, 2005]. After a description of the reference SCWR design, the Keno V 3-D single assembly model used for this analysis, as well as the calculated results, are presented. Additionally, the follwing information, presented in the appendixes, is intended to provide enough guidance that a researcher repeating the same task in the future should be able to obtain a vector of nuclei and cross sections ready for insertion into the transmutation library without any need for further instructions: (1) Complete TRITON/KENO-V input used for the analysis; (2) Inputs and detailed description of the usage of the OPUS utility, used to postproces and to extract the nuclei concentrations for the transmutation library; (3) Inputs and detailed description of the usage of the XSECLIST utility, used to postproces and to extract the 1-group cross sections for the transmutation library; (4) Details of an ad-hoc utility program developed to sort the nuclei and cross sections for the transmutation library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phenylnaphthalene Derivatives as Heat Transfer Fluids for Concentrating Solar Power: Loop Experiments and Final Report

ORNL and subcontractor Cool Energy completed an investigation of higher-temperature, organic thermal fluids for solar thermal applications. Although static thermal tests showed promising results for 1-phenylnaphthalene, loop testing at temperatures to 450 C showed that the material isomerized at a slow rate. In a loop with a temperature high enough to drive the isomerization, the higher melting point byproducts tended to condense onto cooler surfaces. So, as experienced in loop operation, eventually the internal channels of cooler components such as the waste heat rejection exchanger may become coated or clogged and loop performance will decrease. Thus, pure 1-phenylnaphthalene does not appear to be a fluid that would have a sufficiently long lifetime (years to decades) to be used in a loop at the increased temperatures of interest. Hence a decision was made not to test the ORNL fluid in the loop at Cool Energy Inc. Instead, Cool Energy tested and modeled power conversion from a moderate-temperature solar loop using coupled Stirling engines. Cool Energy analyzed data collected on third and fourth generation SolarHeart Stirling engines operating on a rooftop solar field with a lower temperature (Marlotherm) heat transfer fluid. The operating efficiencies of the Stirling engines were determined at multiple, typical solar conditions, based on data from actual cycle operation. Results highlighted the advantages of inherent thermal energy storage in the power conversion system.

concentrating solar power↗

NREL Pyrheliometer Comparison: September 16 to 27, 2013 (NPC-2013)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for the development and deployment of solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations traceable to an international standard is the first step in producing research-quality solar irradiance measurements. As with all measurement systems, absolute cavity radiometers and other types of pyrheliometers are subject to performance changes over time. NREL has developed and maintained a group of absolute cavity radiometers with direct calibration traceability to the World Radiometric Reference (WRR). These reference instruments are used by NREL to calibrate pyrheliometers and pyranometers using the ISO 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). NPCs are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all pyrheliometer owners/operators, e.g. NREL, NASA, NIST, NOAA, USA industry and academia, USA-DOE and other national laboratories, and national and international organizations. Each NPC provides an opportunity to determine the unique World Radiometric Reference (WRR) transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the International System of Units through WRR.

14 SOLAR ENERGY↗

Process/Equipment Co-Simulation on Syngas Chemical Looping Process

The chemical looping strategy for fossil energy applications promises to achieve an efficient energy conversion system for electricity, liquid fuels, hydrogen and/or chemicals generation, while economically separate CO 2 by looping reaction design in the process. Chemical looping particle performance, looping reactor engineering, and process design and applications are the key drivers to the success of chemical looping process development. In order to better understand and further scale up the chemical looping process, issues such as cost, time, measurement, safety, and other uncertainties need to be examined. To address these uncertainties, advanced reaction/reactor modeling and process simulation are highly desired and the modeling efforts can accelerate the chemical looping technology development, reduce the pilot-scale facility design time and operating campaigns, as well as reduce the cost and technical risks. The purpose of this work is thus to conduct multiscale modeling and simulations on the key aspects of chemical looping technology, including particle reaction kinetics, reactor design and operation, and process synthesis and optimization.

42 ENGINEERING↗

Development of a Smart MicroGrid Testbed

Demand for electricity is rapidly increasing thereby applying pressure to expand generation and distribution capacity worldwide. The expansion of traditional services not only imposes burdens on financial resources but also encounters many challenges from community residents who oppose the construction of new power generation plants or transmission facilities in their backyard. From the integrated resource planning point of view, a feasible and economical remedy is, therefore, to utilize existing dispersed generation capacity known as distributed generation (DG) and/or renewable energy resources that may exist in the vicinity of the load centers. The main criteria for selecting the type of fuel source for a DG is its local availability, conversion system technological advancement, impact on the environment, and operating cost. DG’s have existed in the market for many years. Large diesel or gas powered generation sets are used in stand-by mode to power up vital services such as hospitals, financial and commercial compounds, telecommunication centers and industrial premises. Wind turbines, photovoltaic energy sources, and fuel cells are new comers that are now competing in size and efficiency with many standard generating sets. With this in mind, they are being used in many places not only as stand-by units but as the prime source of power particularly when the $\$$/kWhr rate is high.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NREL Pyrheliometer Comparisons: September 22-26, 2014 (NPC-2014)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. As with all measurement systems, absolute cavity radiometers and other types of pyrheliometers are subject to performance changes over time. NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the World Radiometric Reference (WRR), and uses these reference instruments to calibrate pyrheliometers and pyranometers using the ISO 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process. National Renewable Energy Laboratory (NREL) pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all pyrheliometer owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR. NPC-2014 was held September 22-26, 2014. Participants operated 36 absolute cavity radiometers and 22 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky direct normal solar irradiance during this period, and this report documents the findings.

14 SOLAR ENERGY↗

FY 2014 Sodium-Supercritical CO 2 Interactions in the SNAKE Experiment Facility

One appealing feature of the supercritical carbon dioxide Brayton cycle energy conversion system is the small footprint that the hardware requires, which is in part due to the use of compact diffusion-bonded heat exchangers such as Printed Circuit Heat Exchanger (PCHEs) or Hybrid Heat Exchangers (H 2 X) as the heat source heat exchanger (sodium-to-CO 2 ) as well as the recuperator and cooler modules. Although PCHEs and H 2 Xs have a high degree of structural integrity, the potential for leaks to develop between the sodium and CO 2 coolant channels in the heat exchanger cannot be ruled out, and this would lead to discharge of high pressure CO 2 into the secondary coolant circuit. Due to the robustness of the PCHE design, catastrophic failure leading to CO 2 jet blowdown into the secondary sodium loop is not deemed likely. Rather, small cracks (or micro-leaks) may develop in which CO 2 will bleed into the secondary system at a relatively low rate and chemically react with the sodium. The goal of the sodium-CO 2 interaction tests is to gain a fundamental understanding of sodium-CO 2 interactions under prototypical conditions of compact diffusion-bonded heat exchanger failure, a fundamental understanding of self-plugging if it occurs, and the development of one-dimensional phenomenological models for the interactions between high-pressure CO 2 issuing into liquid sodium from a micro-leak across a stainless steel pressure boundary. These models will be validated using experiment data. Therefore, an experiment program at Argonne was initiated in Fiscal Year 2010 to investigate the reaction behavior between sodium and CO 2 under micro-leak conditions. Several reports have described the facility scaling rationale and design. Assembly of the SNAKE (S-CO 2 , Na Kinetics Experiment) began in Fiscal Year 2011 and was completed in July 2012. The sodium inventory in this facility consists of approximately 44 lbs (20 kg; ~21 L/5.5 gal).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Description of the First Observed Sodium-C0 2 Reactions in the Sodium CO 2 Interaction Experiment (SNAKE)

One appealing feature of the supercritical carbon dioxide Brayton cycle energy conversion system is the small footprint that the hardware requires, which is in part due to the use of Printed Circuit Heat Exchangers (PCHEs) as the heat source heat exchanger (sodium-to-CO 2 ) as well as the recuperator and cooler modules. Although PCHEs have a high degree of structural integrity, the potential for leaks to develop between the sodium and CO 2 coolant channels in the secondary heat exchanger cannot be ruled out, and this would lead to discharge of high pressure CO 2 into the secondary coolant circuit. Due to the robustness of the PCHE design, catastrophic failure leading to CO 2 jet blowdown into the secondary sodium loop is not deemed likely. Rather, small cracks (or micro-leaks) may develop in which CO 2 will bleed into the secondary system at a relatively low rate and chemically react with the sodium. The goal of the sodium-CO 2 interaction tests is to gain a fundamental understanding of sodium-CO 2 interactions under prototypical conditions of compact diffusion-bonded heat exchanger failure, a fundamental understanding of self-plugging if it occurs, and the development of one-dimensional phenomenological models for the interactions between high-pressure CO 2 issuing into liquid sodium from a micro-leak across a stainless steel pressure boundary. These models will be validated using experiment data. Therefore, an experiment program at Argonne was initiated in Fiscal Year 2010 to investigate the reaction characteristics between sodium and CO 2 under micro-leak conditions. Several reports have described the facility scaling rationale and design. Assembly of the SNAKE (S-CO 2 , Na Kinetics Experiment) began in Fiscal Year 2011 and was completed in July 2012. Approximately 44 lbs (20 kg; ~21 L/5.5 gal) of sodium was transferred into the SNAKE dump tank from a drum of clean sodium in July 2012.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conjugated ionomers for photovoltaic applications: electric field driven charge separation in organic photovoltaics (Final Technical Report)

The central goal of the work we completed was been to understand the photochemical and photovoltaic properties of ionically functionalized conjugated polymers (conjugated ionomers or polyelectrolytes) and energy conversion systems based on them. We primarily studied two classes of conjugated polymer interfaces that we developed based either upon undoped conjugated polymers with an asymmetry in ionic composition (the ionic junction) or doped conjugated polymers with an asymmetry in doping type (the p-n junction). The materials used for these studies have primarily been the polyacetylene ionomers. We completed a detailed study of p-n junctions with systematically varying dopant density, photochemical creation of doped junctions, and experimental and theoretical work on charge transport and injection in polyacetylene ionomers. We have also completed related work on the use of conjugated ionomers as interlayers that improve the efficiency or organic photovoltaic systems and studied several important aspects of the chemistry of ionically functionalized semiconductors, including mechanisms of so-called "anion-doping", the formation of charge transfer complexes with oxygen, and the synthesis of new polyfluorene polyelectrolytes. We also worked worked with the Haley group at the University of Oregon on new indenofluorene-based organic acceptors.

14 SOLAR ENERGY↗

FASTER test reactor preconceptual design report summary

The FASTER reactor plant is a sodium-cooled fast spectrum test reactor that provides high levels of fast and thermal neutron flux for scientific research and development. The 120MWe FASTER reactor plant has a superheated steam power conversion system which provides electrical power to a local grid allowing for recovery of operating costs for the reactor plant.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NREL Pyrheliometer Comparisons: September 26-October 7, 2016 (NPC-2016)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. National Renewable Energy Laboratory (NREL) pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all pyrheliometer owners and operators, each NPC provides an opportunity to determine the unique World Radiometric Reference transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR. NPC-2016 was September 26 through October 7, 2016. Participants operated 45 absolute cavity radiometers and 27 conventional thermopile-based pyrheliometers to simultaneously measure clear-sky, direct normal solar irradiance during this period.

14 SOLAR ENERGY↗