Search NASA⌕ Search

SEARCH · Search NASA

Results for “Critical Velocity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

An examination of a group-velocity criterion for the breakdown of an idealized vortex flow

The phenomenon of vortex breakdown is believed to be associated with a finite amplitude wave that has become trapped at the critical or breakdown location. The conditions at which the propagating waves become trapped at a certain axial location were examined by use of a group-velocity criterion implied by Landahl's general theory of wave trapping. An ideal vortex having constant vorticity and uniform axial velocity at the inlet of a slowly diverging duct was studied. The linear wave propagation analysis is applied to the base flow at several axial stations for several values of the ratio of swirl velocity to axial velocity at the inlet of the divergent duct, assuming a locally parallel flow. The dipsersion relations and hence the group velocities of both the symmetric (n = 0) and asymmetric modes (n = + or - 1) were investigated. The existence of a critical state in the flow (at which the group velocity vanishes), and its relationship to the stagnation point on the axis of the duct and to the occurrence of an irregular singularity in the equations governing wave propagation in the flow field are discussed.

Tsai, C. Y.↗

On the propagation velocity of a detonation-shock combined wave

A quasi-one-dimensional analysis and a generalized Chapman-Jouguet condition are developed for a gaseous free detonation in an inert environment. Two characteristic features derived from the results are that there exists a lower limit on the heat of combustion, the charge diameter, and the molecular weight of the ambient gas and that there are two propagation velocities for a parameter combination above a certain critical value. Therefore the detonation failure of a free gas column is a hydrodynamic rather than a chemical phenomenon.

Tsuge, S.↗

EUV spectroscopic plasma diagnostics for the solar wind acceleration region

Possibilities are considered for probing physical conditions in the solar corona with strong EUV resonance lines from ions such as N V, O VI, Ne VIII, Mg X, and Si XII. Through measurements of the intensities and profiles of EUV spectral lines with coronagraphic instrumentation employing normal incidence reflecting optics, it is possible to acquire information on electron, proton, and ion temperatures and velocity distributions; electron, H I, and ion densities; mass flow and nonthermal velocities; and chemical abundances. This information will provide critical empirical constraints on physical processes responsible for plasma heating, solar wind acceleration, and transport of mass, momentum, and energy in the solar corona, as well as providing constraints on theoretical models for solar and stellar coronae and mass loss.

Kohl, J. L.↗

Comments on 'Frontogenesis in a moist semigeostrophic model'

The development of narrow updrafts or jetlike features in the vertical motion field (VMF) over the leading edge of a surface frontal zone is examined on the basis of model simulations, summarizing and clarifying the results presented by Keyser and Anthes (1982) and responding to critical remarks by Mak and Bannon (1984). Typical velocity and potential-temperature cross sections are shown, and it is concluded that the inclusion of generally parameterized planetary-boundary-layer (PBL) physics in the model has a significant effect on the VMF, suggesting that frictional processes alone (without latent heating) can explain the formation of jetlike frontal updrafts. In a reply by Mak and Bannon it is argued that the increased strength of the VMF in models including PBL physics is not significant, whereas other models show that the VMF can be significantly strengthened and narrowed by condensational heating alone.

Keyser, D.↗

Resolution of holograms produced by the fluid experiment system and the holography ground system

The Fluid Experiment System (FES) was developed to study low temperature crystal growth of triglycine sulfate from solution in a low gravity environment onboard Spacelab. The first flight of FES was in 1985. FES uses an optical system to take holograms of the growing crystal to be analyzed after the mission in the Holography Ground System (HGS) located in the Test Laboratory at Marshall Space Flight Center. Microscopic observation of the images formed by the reconstructed holograms is critical to determining crystal growth rate and particle velocity. FES and HGS were designed for a resolution of better than 20 micrometers, but initial observation of the flight holograms show a limit of 80 micrometers. The resolution of the FES holograms is investigated, as well as the role of beam intensity ratio and exposure time on the resolution of HGS produced holograms.

Brooks, Howard L.↗

Acousto-ultrasonic input-output characterization of unidirectional fiber composite plate by SV waves

A unidirectional fiberglass epoxy compostie specimen is modelled as a homogeneous transversely isotropic continuum plate medium. Acousto-ultrasonic noncontact input-output characterization is studied theoretically with a transmitting and a receiving transducer located on the same face of the plate. The single reflection problem for an incident SV wave at a plane boundary in transversely isotropic medium is analyzed. An obliquely incident SV wave results in a reflected SV wave and a reflected P wave for an angle of incidence of the incident SV wave less than the critical angle. Otherwise, there exists only an SV wave in the medium as the reflected P wave degenerates into a surface wave travelling parallel to the plane boundary. The amplitude ratio of the reflected SV wave is -1 when the angle of incidence is greater than or = the critical angle. The directional dependence of the phase velocity of the SV wave propagating in the transversely isotropic medium has a significant effect on the delay time, as opposed to the directional independence of the phase velocity of a shear wave propagating in an isotropic medium. The displacements associated with the SV wave in the plate and which may be detected by the noncontact receiving transducer are approximated by an asymptotic solution for an infinite transversely isotropic medium subjected to a harmonic point load.

Liao, Peter↗

Flight survey of the 757 wing noise field and its effects on laminar boundary layer transition. Volume 1: Program description and data analysis

It was previously observed that an incident acoustic field on a wing with laminar flow can cause transition to turbulent flow if the fluctuating acoustic velocities are of sufficient amplitude and in the critical frequency range for an unstable laminar boundary layer. A section of a wing was modified with a natural laminar flow (NLF) glove to allow direct measurement of the effect of varying engine noise on the extent of laminar flow. The flight test program was completed in June, 1985. At each flight condition, the engine power was varied from about 2600 r/min (idle) to about 4500 r/min (maximum continuous power). The spectral data provides considerable insight into the influences of the various sound sources that contribute to the overall noise levels. Additional analysis will be required to assess the impact of these sources on boundary layer transition. These results demonstrate that substantial laminar flow on the wing of a transport configuration with wing-mounted engines can be obtained.

Source record↗

The determination of time-stationary two-dimensional convection patterns with single-station radars

A critical examination of the accuracy of ionospheric vector velocity determinations, using realistic modeled flow patterns that are time-stationary but not spatially uniform, is presented. Under certain circumstances the actual and inferred flow fields are found to exhibit considerable discrepancy, sometimes not even agreeing in the sense of flow direction. It is shown that the natural curvature present in ionospheric convection on varying spatial scales can introduce significant error in the velocity estimate, particularly when the radius of curvature of the flow structure is less than or equal to the radar range to the scattering volume. It is argued that the ionospheric convection should be measured by bidirectional or multidirectional observations of a common ionospheric volume and that a synthesis of coherent and incoherent radar observations from different sites is preferable to multidirectional single-station observations using either radar alone.

Freeman, M. P.↗

Secondary processing of chondrules and refractory inclusions (CAIs) by gasdynamic heating

Results of calculations performed to determine the conditions necessary for producing the opaque rims on chondrules and CAI rims by high-speed entry into the transient atmosphere of an accreting meteorite parent body are presented. The sensitivity of these results to variations in critical parameters is investigated. The range of entry velocities which can produce such rims is shown to depend on the size, melting temperature, and thermal conductivity of the particles. For particles greater than 2 mm in radius, with thermal conductivities of 20,000 ergs/sm s K or lower, entry velocities of about 3 km/s suffice. For particle sizes less than 1 mm in radius, the range of encounter velocities that can produce rims is narrow or vanishing, regardless of the thermal conductivity, unless the melting temperature in the outer part of the chondrule has been reduced by compositional heterogeneity.

Podolak, M.↗

Characterization of Aircraft Structural Damage Using Guided Wave Based Finite Element Analysis for In-Flight Structural Health Management

The development of multidisciplinary Integrated Vehicle Health Management (IVHM) tools will enable accurate detection, diagnosis and prognosis of damage under normal and adverse conditions during flight. The adverse conditions include loss of control caused by environmental factors, actuator and sensor faults or failures, and structural damage conditions. A major concern is the growth of undetected damage/cracks due to fatigue and low velocity foreign object impact that can reach a critical size during flight, resulting in loss of control of the aircraft. To avoid unstable catastrophic propagation of damage during a flight, load levels must be maintained that are below the load-carrying capacity for damaged aircraft structures. Hence, a capability is needed for accurate real-time predictions of safe load carrying capacity for aircraft structures with complex damage configurations. In the present work, a procedure is developed that uses guided wave responses to interrogate damage. As the guided wave interacts with damage, the signal attenuates in some directions and reflects in others. This results in a difference in signal magnitude as well as phase shifts between signal responses for damaged and undamaged structures. Accurate estimation of damage size and location is made by evaluating the cumulative signal responses at various pre-selected sensor locations using a genetic algorithm (GA) based optimization procedure. The damage size and location is obtained by minimizing the difference between the reference responses and the responses obtained by wave propagation finite element analysis of different representative cracks, geometries and sizes.

Seshadri, Banavara R.↗

Structural Health Management of Damaged Aircraft Structures Using the Digital Twin Concept

The development of multidisciplinary integrated Structural Health Management (SHM) tools will enable accurate detection, and prognosis of damaged aircraft under normal and adverse conditions during flight. As part of the digital twin concept, methodologies are developed by using integrated multiphysics models, sensor information and input data from an in-service vehicle to mirror and predict the life of its corresponding physical twin. SHM tools are necessary for both damage diagnostics and prognostics for continued safe operation of damaged aircraft structures. The adverse conditions include loss of control caused by environmental factors, actuator and sensor faults or failures, and structural damage conditions. A major concern in these structures is the growth of undetected damage/cracks due to fatigue and low velocity foreign object impact that can reach a critical size during flight, resulting in loss of control of the aircraft. To avoid unstable, catastrophic propagation of damage during a flight, load levels must be maintained that are below a reduced load-carrying capacity for continued safe operation of an aircraft. Hence, a capability is needed for accurate real-time predictions of damage size and safe load carrying capacity for structures with complex damage configurations. In the present work, a procedure is developed that uses guided wave responses to interrogate damage. As the guided wave interacts with damage, the signal attenuates in some directions and reflects in others. This results in a difference in signal magnitude as well as phase shifts between signal responses for damaged and undamaged structures. Accurate estimation of damage size, location, and orientation is made by evaluating the cumulative signal responses at various pre-selected sensor locations using a genetic algorithm (GA) based optimization procedure. The damage size, location, and orientation is obtained by minimizing the difference between the reference responses and the responses obtained by wave propagation finite element analysis of different representative cracks, geometries, and sizes.

Seshadri, Banavara R.↗

Transport processes in boiling and two-phase systems, including near-critical fluids

Aspects of pool boiling are considered, taking into account nucleate boiling, the nucleate boiling mechanism, film boiling, and the transition between nucleate and film boiling. The characteristics of two-phase flow are also investigated, giving attention to two-phase flow parameters and equations, the flow pattern in two-phase flow, the pressure drop in two-phase flow, heat transfer in two-phase flow, two-phase flow dynamics, the boiling crisis in two-phase flow, the critical flow rate, the propagation of the pressure pulse and the sonic velocity in two-phase media, instrumentation for two-phase flow, and geometry and field effects on boiling and two-phase flow. Near-critical fluids are also considered.

Hsu, Y.-Y.↗

Forced Convection Boiling and Critical Heat Flux of Ethanol in Electrically Heated Tube Tests

Electrically heated tube tests were conducted to characterize the critical heat flux (transition from nucleate to film boiling) of subcritical ethanol flowing at conditions relevant to the design of a regeneratively cooled rocket engine thrust chamber. The coolant was SDA-3C alcohol (95% ethyl alcohol, 5% isopropyl alcohol by weight), and tests were conducted over the following ranges of conditions: pressure from 144 to 703 psia, flow velocities from 9.7 to 77 ft/s, coolant subcooling from 33 to 362 F, and critical heat fluxes up to 8.7 BTU/in(exp 2)/sec. For the data taken near 200 psia, critical heat flux was correlated as a function of the product of velocity and fluid subcooling to within +/- 20%. For data taken at higher pressures, an additional pressure term is needed to correlate the critical heat flux. It was also shown that at the higher test pressures and/or flow rates, exceeding the critical heat flux did not result in wall burnout. This result may significantly increase the engine heat flux design envelope for higher pressure conditions.

Meyer, Michael L.↗

Mitral inertance in humans: critical factor in Doppler estimation of transvalvular pressure gradients

The pressure-velocity relationship across the normal mitral valve is approximated by the Bernoulli equation DeltaP = 1/2 rhoDeltav(2) + M. dv/dt, where DeltaP is the atrioventricular pressure difference, rho is blood density, v is transmitral flow velocity, and M is mitral inertance. Although M is indispensable in assessing transvalvular pressure differences from transmitral flow, this term is poorly understood. We measured intraoperative high-fidelity left atrial and ventricular pressures and simultaneous transmitral flow velocities by using transesophageal echocardiography in 100 beats (8 patients). We computed mean mitral inertance (M) by M = integral((DeltaP)-(1/2 x rho v(2))dt/integral(dv/dt)dt and we assessed the effect of the inertial term on the transmitral pressure-flow relation. ranged from 1.03 to 5.96 g/cm(2) (mean = 3.82 +/- 1.22 g/cm(2)). DeltaP calculated from the simplified Bernoulli equation (DeltaP = 1/2. rhov(2)) lagged behind (44 +/- 11 ms) and underestimated the actual peak pressures (2.3 +/- 1.1 mmHg). correlated with left ventricular systolic pressure (r = -0.68, P < 0.0001) and transmitral pressure gradients (r = 0.65, P < 0.0001). Because mitral inertance causes the velocity to lag significantly behind the actual pressure gradient, it needs to be considered when assessing diastolic filling and the pressure difference across normal mitral valves.

NASA Discipline Cardiopulmonary↗

Reflection Properties of Metallic Gratings on ZnO Films over GaAs Substrates

A potential application for piezoelectric film deposited on GaAs substrates is the monolithic integration of surface acoustic wave (SAW) devices with GaAs electronics. Metallic gratings are basic elements required for the construction of such devices, and analyzing the reflectivity and the velocity change due to metallic gratings is often a critical design parameter. In this article, Datta and Hunsinger technique is extended to the case of a multilayered structure, and the developed technique is applied to analyze shorted and open gratings on ZnO films sputtered over (001)-cut (110)-propagating GaAs substrates. The analysis shows that zero reflectivity of shorted gratings can be obtained by a combination of the ZnO film and the metal thickness and the metalization ratio of the grating. Experiments are performed on shorted and an open gratings (with the center frequency of about 180 MHz) for three different metal thicknesses over ZnO films which are 0.8 and 2.6 micrometers thick. From the experiments, zero reflectivity at the resonant frequency of the grating is observed for a reasonable thickness (h/Alpha = 0.5%) of aluminum metalization. The velocity shift between the shorted and the open grating is also measured to be 0.18 MHz and 0.25 MHz for 0.8 and 1.6 micrometers respectively. The measured data show relatively good agreement with theoretical predictions.

Hickernell, Fred S.↗

Characterization of Large Drop Velocity in the NASA Icing Research Tunnel

This paper presents experimental work conducted in the Icing Research Tunnel at NASA Glenn Research Center to characterize the velocity of large drops in the test section. Some icing spray clouds with large drops were generated with Mod1 nozzles at low nozzle air pressure of 2 to 4 psig for various tunnel air speeds. Drop diameters and drop velocities were measured via high-resolution imaging with a Particle Imaging Particle Tracking Velocimetry probe developed by Artium Technologies. The probe was mounted at four different locations aligned with the centerline of the test section from near the end of the contraction to the constant height test section part of the tunnel. CFD analyses were performed. It showed that the probe head geometry affects the local air flow in the measurement area of the probe between the prongs and in front of the probe. Initial analysis of the air velocity data during the test also indicated that the probe mounting stand has blockage effect on the local tunnel air velocity measurement by a pitot-static probe affixed on the mounting plate next to the stand. Those findings were later verified in the Icing Research Tunnel using a new pitot-static probe design with a linear motion system to measure the local tunnel air velocity with and without the probe. As a result, additional drop trajectory simulations were performed with the airflow moving towards the probe head with a Langmuir-D 7-bin distribution cloud containing large drops. The simulation results helped identify a critical drop-size threshold of 300 μm above which the velocities of larger drops are negligibly affected by the adverse pressure gradient generated by the probe head due to their large drop inertia. From the dimensional analysis of the drop velocity measurement data obtained, it showed that at the tunnel test section reference location a generalized empirical correlation was developed for the non-dimensional drop velocity as a function of the non-dimensional corrected drop diameter independent of the actual spraybar pressure settings and the tunnel air speeds. The generalized curve-fit correlation showed that the drop velocity was universally asymptotic to about 86 percent of the corresponding tunnel air speed at the test section reference location for the largest drop diameter captured by the probe. Further evaluation of this correlation is recommended to assess its applicability for Supercooled Large Drop icing scaling applications in the Icing Research Tunnel.

SLD↗

Surface representations of two- and three-dimensional fluid flow topology

We discuss our work using critical point analysis to generate representations of the vector field topology of numerical flow data sets. Critical points are located and characterized in a two-dimensional domain, which may be either a two-dimensional flow field or the tangential velocity field near a three-dimensional body. Tangent curves are then integrated out along the principal directions of certain classes of critical points. The points and curves are linked to form a skeleton representing the two-dimensional vector field topology. When generated from the tangential velocity field near a body in a three-dimensional flow, the skeleton includes the critical points and curves which provide a basis for analyzing the three-dimensional structure of the flow separation. The points along the separation curves in the skeleton are used to start tangent curve integrations to generate surfaces representing the topology of the associated flow separations.

Helman, James L.↗

Influence of a Backward-Facing Step on Swept-Wing Boundary-Layer Transition

Experimental measurements were performed on a swept flat-plate model with an airfoil leading edge and imposed chordwise pressure gradient to determine the effects of a backward-facing step on transition in a low-speed stationary crossflow-dominated boundary layer. Detailed hot-wire measurements were performed for three step heights ranging from 36 to 49% of the boundary-layer thickness at the step and corresponding to subcritical, nearly critical, and critical cases. In general, the step had a small localized effect on the growth of the stationary crossflow vortex, whereas the unsteady disturbance amplitudes increased with increasing step height. Intermittent spikes in instantaneous velocity began to appear for the two larger step heights. A physical explanation was provided for the mechanism leading to transition and the sudden movement in the transition front due to the critical steps. The large localized velocity spikes, which ultimately led to an intermittent breakdown of the boundary layer, were the result of nonlinear interactions of the different types of unsteady instabilities with each other and with the stationary crossflow vortices. Thus, the unsteady disturbances played the most important role in transition, but the stationary crossflow vortices also had a significant role via the modulation and the increased amplitude of the unsteady disturbances.

Eppink, Jenna L.↗