Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETAILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Evolution effects on parton energy loss with detailed balance

The initial conditions in the chemically nonequilibrated medium and Bjorken expanding medium at Relativistic Heavy Ion Collider (RHIC) are determined. With a set of rate equations describing the chemical equilibration of quarks and gluons based on perturbative QCD, we investigate the consequence for parton evolution at RHIC. With considering parton evolution, it is shown that the Debye screening mass and the inverse mean free-path of gluons reduce with increasing proper time in the QGP medium. The parton evolution affects the parton energy loss with detailed balance, both parton energy loss from stimulated emission in the chemically nonequilibrated expanding medium and in Bjorken expanding medium are linear dependent on the propagating distance rather than square dependent in the static medium. The energy absorption cannot be neglected at intermediate jet energies and small propagating distance of the energetic parton in contrast with that it is important only at intermediate jet energy in the static medium. This will increase the energy and propagating distance dependence of the parton energy loss and will affect the shape of suppression of moderately high P{sub T} hadron spectra.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axion Dark Matter eXperiment: Run 1A analysis details

The ADMX Collaboration gathered data for its Run 1A axion dark matter search from January 2017 to June 2017, scanning with an axion haloscope over the frequency range 645–680 MHz ( 2.66 – 2.81 μ eV in axion mass) at Dine-Fischler-Srednicki-Zhitnitskii (DFSZ) sensitivity. The resulting axion search found no axionlike signals comprising all the dark matter in the form of a virialized galactic halo over the entire frequency range, implying lower bound exclusion limits at or below DFSZ coupling at the 90% confidence level. This paper presents expanded details of the axion search analysis of Run 1A, including review of relevant experimental systems, data-taking operations, preparation and interpretation of raw data, axion search methodology, candidate handling, and final axion limits. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm

We present details on a new measurement of the muon magnetic anomaly, a μ =(g μ −2)/2. The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses 3.1 GeV/c polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of a μ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure a μ =116592057(25)×10 −11 (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield a μ (FNAL)=116592055(24)×10 −11 (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is a μ (exp)=116592059(22)×10 −11 (0.19 ppm).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detailed discussions and calculations of quantum Regge calculus of Einstein-Cartan theory

This article presents detailed discussions and calculations of the recent paper 'Quantum Regge calculus of Einstein-Cartan theory' in [9]. The Euclidean space-time is discretized by a four-dimensional simplicial complex. We adopt basic tetrad and spin-connection fields to describe the simplicial complex. By introducing diffeomorphism and local Lorentz invariant holonomy fields, we construct a regularized Einstein-Cartan theory for studying the quantum dynamics of the simplicial complex and fermion fields. This regularized Einstein-Cartan action is shown to properly approach to its continuum counterpart in the continuum limit. Based on the local Lorentz invariance, we derive the dynamical equations satisfied by invariant holonomy fields. In the mean-field approximation, we show that the averaged size of 4-simplex, the element of the simplicial complex, is larger than the Planck length. This formulation provides a theoretical framework for analytical calculations and numerical simulations to study the quantum Einstein-Cartan theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inhibition of d-xylose isomerase by polyols: atomic details by joint X-ray/neutron crystallography

A joint X-ray/neutron structure of d-xylose isomerase in complex with the inhibitor sorbitol was determined at room temperature at an acidic pH of 5.9. Protonation of the O5 O atom of the sugar was directly observed in the nuclear density maps. Under acidic conditions sorbitol gains a water-mediated interaction with the enzyme active site, which may explain the increased potency of the inhibitor at low pH. d-Xylose isomerase (XI) converts the aldo-sugars xylose and glucose to their keto analogs xylulose and fructose, but is strongly inhibited by the polyols xylitol and sorbitol, especially at acidic pH. In order to understand the atomic details of polyol binding to the XI active site, a 2.0 Å resolution room-temperature joint X-ray/neutron structure of XI in complex with Ni{sup 2+} cofactors and sorbitol inhibitor at pH 5.9 and a room-temperature X-ray structure of XI containing Mg{sup 2+} ions and xylitol at the physiological pH of 7.7 were obtained. The protonation of oxygen O5 of the inhibitor, which was found to be deprotonated and negatively charged in previous structures of XI complexed with linear glucose and xylulose, was directly observed. The Ni{sup 2+} ions occupying the catalytic metal site (M2) were found at two locations, while Mg{sup 2+} in M2 is very mobile and has a high B factor. Under acidic conditions sorbitol gains a water-mediated interaction that connects its O1 hydroxyl to Asp257. This contact is not found in structures at basic pH. The new interaction that is formed may improve the binding of the inhibitor, providing an explanation for the increased affinity of the polyols for XI at low pH.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards the spatial resolution of metalloprotein charge states by detailed modeling of XFEL crystallographic diffraction

Oxidation states of individual metal atoms within a metalloprotein can be assigned by examining X-ray absorption edges, which shift to higher energy for progressively more positive valence numbers. Indeed, X-ray crystallography is well suited for such a measurement, owing to its ability to spatially resolve the scattering contributions of individual metal atoms that have distinct electronic environments contributing to protein function. However, as the magnitude of the shift is quite small, about +2 eV per valence state for iron, it has only been possible to measure the effect when performed with monochromated X-ray sources at synchrotron facilities with energy resolutions in the range 2–3 × 10 −4 (Δ E / E ). This paper tests whether X-ray free-electron laser (XFEL) pulses, which have a broader bandpass (Δ E / E = 3 × 10 −3 ) when used without a monochromator, might also be useful for such studies. The program nanoBragg is used to simulate serial femtosecond crystallography (SFX) diffraction images with sufficient granularity to model the XFEL spectrum, the crystal mosaicity and the wavelength-dependent anomalous scattering factors contributed by two differently charged iron centers in the 110-amino-acid protein, ferredoxin. Bayesian methods are then used to deduce, from the simulated data, the most likely X-ray absorption curves for each metal atom in the protein, which agree well with the curves chosen for the simulation. The data analysis relies critically on the ability to measure the incident spectrum for each pulse, and also on the nanoBragg simulator to predict the size, shape and intensity profile of Bragg spots based on an underlying physical model that includes the absorption curves, which are then modified to produce the best agreement with the simulated data. This inference methodology potentially enables the use of SFX diffraction for the study of metalloenzyme mechanisms and, in general, offers a more detailed approach to Bragg spot data reduction.

59 BASIC BIOLOGICAL SCIENCES↗

Trelliscope: A System for Detailed Visualization in Analysis of Large Complex Data

Visualization plays a critical role in the statistical model building and data analysis process. Data analysts, well-versed in statistical and machine learning methods, visualize data to hypothesize and validate models. These analysts need flexible, scalable visualization tools that are not decoupled from their analysis environment. In this paper we introduce Trelliscope, a visualization framework for statistical analysis of large complex data. Trelliscope extends Trellis, an effective visualization framework that divides data into subsets and applies a plotting method to each subset, arranging the results in rows and columns of panels. Trelliscope provides a way to create, arrange and interactively view panels for very large datasets, enabling flexible detailed visualization for data of any size. Scalability is achieved using distributed computing technologies coupled with . We discuss the underlying principles, design, and scalable architecture of Trelliscope, and illustrate its use on three analysis projects in the domains of proteomics, high energy physics, and power systems engineering.

Hafen, Ryan P.↗

Byte-precision level of detail processing for variable precision analytics

I/O bottlenecks in HPC applications are becoming a more pressing problem as compute capabilities continue to outpace I/O capabilities. While double-precision simulation data often must be stored losslessly, the loss of some of the fractional component may introduce acceptably small errors to many types of scientific analyses. Given this observation, we develop a precision level of detail (APLOD) library, which partitions double-precision datasets along user-defined byte boundaries. APLOD parameterizes the analysis accuracy-I/O performance tradeoff, bounds maximum relative error, maintains I/O access patterns compared to full precision, and operates with low overhead. Using ADIOS as an I/O use-case, we show proportional reduction in disk access time to the degree of precision. Finally, we show the effects of partial precision analysis on accuracy for operations such as k-means and Fourier analysis, finding a strong applicability for the use of varying degrees of precision to reduce the cost of analyzing extreme-scale data.

Jenkins, John↗

Optimal Operation of Grid-Tied Energy Storage Systems Considering Detailed Device-Level Battery Models

The current optimization-based algorithms to operate grid-tied battery energy storage systems (BESS) typically do not look much under the hood of the BESS, i.e., the device-level characteristics of the batteries. This is often due to modeling as well as optimization complexities. However, simplified models may significantly degrade the performance of BESS operation in practice. Therefore, in this article, we propose a new BESS scheduling optimization framework that accounts for features such as cell-to-cell variations in maximum capacity, charge level balance, and internal resistance. The proposed framework is in the form of tractable mixed integer linear programs. Our approach is to estimate and update the device-level battery model parameters continuously, without the need to interrupt BESS normal operation. We validate the performance compared to an offline approach, which is based on dedicated model testing and calibration. To assure accurate performance evaluation, this article also includes developing a power hardware-in-the-loop testbed that allows for flexible operation and detailed monitoring of BESS under different design scenarios.

25 ENERGY STORAGE↗

A detailed radiobiological and dosimetric analysis of biochemical outcomes in a case-control study of permanent prostate brachytherapy patients

The purpose of this study is to determine dosimetric and radiobiological predictors of biochemical control after recalculation of prostate implant dosimetry using updated AAPM Task Group 43 (TG-43) parameters and the radiobiological parameters recommended by TG-137. All biochemical failures among patients implanted with {sup 125}I or {sup 103}Pd sources between 1994 and March 2006 were matched 2:1 with nonfailure controls. The individual matching was by risk group, radionuclide, prescribed dose, and time of implant (one match before and one after the failed patient) resulting in a median follow-up of 10.9 years. Complete dose volume histogram (DVH) data were recalculated for all 55 cases and 110 controls after updating the original source strength by the retrospectively determined ratios of TG-43. Differential DVH data were acquired in 179 increments of prostate volume versus percentage prescribed dose. At each incremental dose level i, the biologically equivalent dose BED{sub i}, equivalent uniform dose EUD{sub i}, and tumor control probability TCP{sub i} were calculated from the implant dose plus any external beam delivered to the patient. Total BED, EUD, and TCP were then derived from the incremental values for comparison with single point dosimetric quality parameters and DVH-based averages. There was no significant difference between failures and controls in terms of total BED (143 vs 142 Gy), EUD (95 vs 94 Gy), or TCP (0.87 vs 0.89). Conditional logistic regression analysis factored out the matching variables and stratified the cohort into each case and its controls, but no radiobiological parameter was predictive of biochemical failure. However, there was a significant difference between radiobiological parameters of {sup 125}I and {sup 103}Pd due to less complete coverage of the target volume by the former isotope. The implant BED and TCP were highly correlated with the D{sub 90} and natural prescription doses and a series of mean DVH-based doses such as the harmonic mean and expressions of the generalized EUD. In this case-control study of prostate brachytherapy biochemical failures and nonfailures, there were no radiobiological parameters derived from detailed DVH-based analysis that predicted for biochemical control. This may indicate that in our approach, implant dosimetry is at or near the limits of clinically effective dose escalation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-DE-207A-01: Impact of Statistical Weights On Detection of Low-Contrast Details in Model-Based Iterative CT Reconstruction

Purpose: Penalized-weighted least-square reconstruction has become an important research topic in CT, to reduce dose without affecting image quality. Two components impact image quality in this reconstruction: the statistical weights and the use of an edge-preserving penalty term. We are interested in assessing the influence of statistical weights on their own, without the edge-preserving feature. Methods: The influence of statistical weights on image quality was assessed in terms of low-contrast detail detection using LROC analysis. The task amounted to detect and localize a 6-mm lesion with random contrast inside the FORBILD head phantom. A two-alternative forced-choice experiment was used with two human observers performing the task. Reconstructions without and with statistical weights were compared, both using the same quadratic penalty term. The beam energy was set to 30keV to amplify spatial differences in attenuation and thereby the role of statistical weights. A fan-beam data acquisition geometry was used. Results: Visual inspection of images clearly showed a difference in noise between the two reconstructions methods. As expected, the reconstruction without statistical weights exhibited noise streaks. The other reconstruction appeared better in this aspect, but presented other disturbing noise patterns and artifacts induced by the weights. The LROC analysis yield the following 95-percent confidence interval for the difference in reader-averaged AUC (reconstruction without weights minus reconstruction with weights): [0.0026,0.0599]. The mean AUC value was 0.9094. Conclusion: We have investigated the impact of statistical weights without the use of edge-preserving penalty in penalized weighted least-square reconstruction. A decrease rather than increase in image quality was observed when using statistical weights. Thus, the observers were better able to cope with the noise streaks than the noise patterns and artifacts induced by the statistical weights. It may be that different results would be obtained if the penalty term was used with a pixel-dependent weight. F Noo receives research support from Siemens Healthcare GmbH.

60 APPLIED LIFE SCIENCES↗

Aspects of Higgs Physics at a $\sqrt{s}=3$ TeV Muon Collider with detailed detector simulation

The Muon Collider is one of the most promising future collider facilities with the potential to reach multi-TeV center-of-mass energy and high luminosity. Due to the significant Higgs boson production cross section in muon-antimuon collisions at such high energies, the collider offers an excellent opportunity for in-depth exploration of Higgs boson properties. It holds the capability to significantly advance our understanding of the Higgs sector to a very high level of precision. However, the presence of beam-induced background resulting from the decay of the beam muons poses unique challenges for detector development and event reconstruction. In this paper, the prospects for measuring various Higgs boson properties at a center-of-mass energy of 3 TeV are presented, using a detailed detector simulation in a realistic environment. The study demonstrates the feasibility of achieving high precision results with the current state-of-the-art detector design. In addition, the paper discusses the detector requirements necessary to achieve this level of accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detailed Aerosol Optical Depth Intercomparison between Brewer and Li-Cor 1800 Spectroradiometers and a Cimel Sun Photometer

We present here representative results about a comparison of aerosol optical depth (AOD) using different instruments during three short and intensive campaigns carried out from 1999 to 2001 at El Arenosillo (Huelva, Spain). The specific aim of this study is to determine the level of agreement between three different instruments operating at our station. This activity, however, is part of a broader objective to recover an extended data series of AOD in the UV range obtained from a Brewer spectroradiometer. This instrument may be used to obtain AOD at the same five UV wavelengths used during normal operation for ozone content determination. As part of the validation of the Brewer AOD data recovery process, a Cimel sun photometer and another spectroradiometer, a Licor1800, were used. The Licor1800 spectroradiometer (which covers the spectral range 300-1100 nm) was the first instrument used at this station for aerosol monitoring (1996-99) and it was operated during these intercomparison campaigns (1999-2001) specifically to assess the continuity of the AOD data series. The Cimel sunphotometer was installed at our station at the beginning of 2000 as part of AERONET to provide AOD data over the visible and near infrared spectrum. A detailed comparison of these three instruments is carried out by means of near-simultaneous measurements, with particular emphasis on examining any diurnal AOD variability that may be linked with calibration and/or measurement errors or real atmospheric variability. Because the comparison is carried out from UV (320nm) to near infrared (1020nm) wavelengths under all possible atmospheric conditions (including clouds), AOD values range from near zero up to 1. Absolute AOD uncertainties range from 0.02 for the Cimel to 0.08 for the Brewer, with intermediate values for the Licor1800. All the values during the comparison are in reasonable agreement, when taking into account the different performance characteristics of each instrument. The comparison also demonstrates current deficiencies in the Brewer data and thus the difficulty to determine AOD values with low errors.

54 ENVIRONMENTAL SCIENCES↗

Detailed characterization of particulate matter emitted by lean-burn gasoline direct injection engine

This study presents detailed characterization of the chemical and physical properties of PM emitted by a 2.0L BMW lean-burn turbocharged GDI engine operated under a number of combustion strategies that include lean homogeneous, lean stratified, stoichiometric, and fuel rich conditions. We characterized PM number concentrations, size distributions, and the size, mass, compositions, and effective density of fractal and compact individual exhaust particles. For the fractal particles, these measurements yielded fractal dimension, average diameter of primary spherules, and number of spherules, void fraction, and dynamic shape factors as function of particle size. Overall, the PM properties were shown to vary significantly with engine operation condition. Lean stratified operation yielded the most diesel-like size distribution and the largest PM number and mass concentrations, with nearly all particles being fractal agglomerates composed of elemental carbon with small amounts of ash and organics. In contrast, stoichiometric operation yielded a larger fraction of ash particles, especially at low speed and low load. Three distinct forms of ash particles were observed, with their fractions strongly dependent on engine operating conditions: sub-50 nm ash particles, abundant at low speed and low load, ash-containing fractal particles, and large compact ash particles that significantly contribute to PM mass loadings

Environmental Molecular Sciences Laboratory↗

A detailed gene expression study of the Miscanthus genus reveals changes in the transcriptome associated with the rejuvenation of spring rhizomes

Background: The Miscanthus genus of perennial C4 grasses contains promising biofuel crops for temperate climates. However, few genomic resources exist for Miscanthus, which limits understanding of its interesting biology and future genetic improvement. A comprehensive catalog of expressed sequences were generated from a variety of Miscanthus species and tissue types, with an emphasis on characterizing gene expression changes in spring compared to fall rhizomes. Results: Illumina short read sequencing technology was used to produce transcriptome sequences from different tissues and organs during distinct developmental stages for multiple Miscanthus species, including Miscanthus sinensis, Miscanthus sacchariflorus, and their interspecific hybrid Miscanthus × giganteus. More than fifty billion base-pairs of Miscanthus transcript sequence were produced. Overall, 26,230 Sorghum gene models (i.e., ~ 96% of predicted Sorghum genes) had at least five Miscanthus reads mapped to them, suggesting that a large portion of the Miscanthus transcriptome is represented in this dataset. The Miscanthus × giganteus data was used to identify genes preferentially expressed in a single tissue, such as the spring rhizome, using Sorghum bicolor as a reference. Quantitative real-time PCR was used to verify examples of preferential expression predicted via RNA-Seq. Contiguous consensus transcript sequences were assembled for each species and annotated using InterProScan. Sequences from the assembled transcriptome were used to amplify genomic segments from a doubled haploid Miscanthus sinensis and from Miscanthus × giganteus to further disentangle the allelic and paralogous variations in genes. Conclusions: This large expressed sequence tag collection creates a valuable resource for the study of Miscanthus biology by providing detailed gene sequence information and tissue preferred expression patterns. We have successfully generated a database of transcriptome assemblies and demonstrated its use in the study of genes of interest. Analysis of gene expression profiles revealed biological pathways that exhibit altered regulation in spring compared to fall rhizomes, which are consistent with their different physiological functions. The expression profiles of the subterranean rhizome provides a better understanding of the biological activities of the underground stem structures that are essentials for perenniality and the storage or remobilization of carbon and nutrient resources.

59 BASIC BIOLOGICAL SCIENCES↗

CFD Analysis and Design of Detailed Target Configurations for an Accelerator-Driven Subcritical System

High-fidelity analysis has been utilized in the design of beam target options for an accelerator driven subcritical system. Designs featuring stacks of plates with square cross section have been investigated for both tungsten and uranium target materials. The presented work includes the first thermal-hydraulic simulations of the full, detailed target geometry. The innovative target cooling manifold design features many regions with complex flow features, including 90 bends and merging jets, which necessitate three-dimensional fluid simulations. These were performed using the commercial computational fluid dynamics code STAR-CCM+. Conjugate heat transfer was modeled between the plates, cladding, manifold structure, and fluid. Steady-state simulations were performed but lacked good residual convergence. Unsteady simulations were then performed, which converged well and demonstrated that flow instability existed in the lower portion of the manifold. It was established that the flow instability had little effect on the peak plate temperatures, which were well below the melting point. The estimated plate surface temperatures and target region pressure were shown to provide sufficient margin to subcooled boiling for standard operating conditions. This demonstrated the safety of both potential target configurations during normal operation.

43 PARTICLE ACCELERATORS↗

Measurement of angle and axis of rotation in a carousel interferometer: a detailed analysis

A detailed analysis of a carousel interferometer is presented for the measurement of an unknown angle and axis of rotation. The technique exploits a set of compensator glass plates and a right-angle prism that is placed in each of the two arms of the interferometer. The two sets are placed at the same rotational stage, while the end mirrors of the interferometer are static. When rotation takes place, individual and relative optical path differences are generated in the two beams of the interferometer. The generated phase differences contribute toward finding the angle and axis of rotation. The analysis is presented for any initial position of the interferometer, i.e., the radial vector from the axis of rotation to the apex of one of the prisms used. The results show the slight variations in the error and nonlinearity when different parameters are manipulated. Moreover, the trade-off between the maximum size of the prisms and the radial distances are also presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗