Search NASA⌕ Search

SEARCH · Search NASA

Results for “DIAPHRAGM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic pros-thesis fixtion, and dental implants.

Banks, B. A.↗

Potential biomedical applications of ion beam technology

Electron bombardment ion thrusters used as ion sources have demonstrated a unique capability to vary the surface morphology of surgical implant materials. The microscopically rough surface texture produced by ion beam sputtering of these materials may result in improvements in the biological response and/or performance of implanted devices. Control of surface roughness may result in improved attachment of the implant to soft tissue, hard tissue, bone cement, or components deposited from blood. Potential biomedical applications of ion beam texturing discussed include: vascular prostheses, artificial heart pump diaphragms, pacemaker fixation, percutaneous connectors, orthopedic prosthesis fixation, and dental implants.

Banks, B. A.↗

A role for glucose in hypothermic hamsters

Hypothermic hamsters at a rectal temperature of 7 C showed a fivefold increase in survival times from 20 to 100.5 hr when infused with glucose which maintained a blood level at about 45 mg/100 ml. A potential role for osmotic effects of the infusion was tested and eliminated. There was no improvement in survival of 3-O-methylglucose or dextran 40-infused animals. The fact that death eventually occurs even in the glucose-infused animal after about 4 days and that oxygen consumption undergoes a slow decrement in that period suggests that hypothermic survival is not wholly substrate limited. Radioactive tracer showed that localization of the C-14 was greatest in brain tissue and diaphragm, intermediate in heart and kidney, and lowest in skeletal muscle and liver. The significance of the label at sites important to respiration and circulation was presented.

Resch, G. E.↗

Improved control of medical x-ray film exposure

Exposure sensing system for light-intensified motion-picture X-ray system uses aperture or adjustable diaphragm to sample light from image region of interest. Approach, along with approximate optics, can optimize exposure sensitivity.

Berdahl, C. M.↗

Remotely-powered intracranial pressure monitor

Implantable RF powered monitor uses capacitive transducer and stiff metal diaphragm that gives high stability for long term intracranial pressure monitoring. Design of monitor reduces risk of infection while improving patient comfort and mobility.

Fryer, T. B.↗

Mathematical modelling of a human external respiratory system

A closed system of algebraic and common differential equations solved by computer is investigated. It includes equations which describe the activity pattern of the respiratory center, the phrenic nerve, the thrust produced by the diaphragm as a function of the lung volume and discharge frequency of the phrenic nerve, as well as certain relations of the lung stretch receptors and chemoreceptors on various lung and blood characteristics, equations for lung biomechanics, pulmonary blood flow, alveolar gas exchange and capillary blood composition equations to determine various air and blood flow and gas exchange parameters, and various gas mixing and arterial and venous blood composition equations, to determine other blood, air and gas mixing characteristics. Data are presented by means of graphs and tables, and some advantages of this model over others are demonstrated by test results.

Source record↗

Constrained sloshing of liquid mercury in a flexible spherical tank

The mercury propellant tank system developed for use with solar electric propulsion was studied to analytically determine the resonant frequencies of the tank system and compare them with the anticipated control natural frequency of the spacecraft. The system consisted of a stainless steel spherical shell and a hemispherical elastometric diaphragm. The major analytical tool used was the NASTRAN program. Six mathematical models were developed. Resonant frequencies for six harmonics were obtained for each of the six models considered. The results show that the lowest resonant frequency for the tank system is about an order of magnitude greater than the anticipated control frequency of the spacecraft.

Lestingi, J.↗

Infrared observations of the galactic center. II - Forbidden Ne II emission

The forbidden Ne II line flux has been measured with a 5-arcsec diaphragm at eight positions in the galactic-center (Sgr A-West) region. The line fluxes - and hence the density of ionized gas - are not correlated with the presence of discrete compact sources of 10-micron continuum radiation. The discrete sources probably contain sources of energy that heat nearby dust instead of being regions of enhanced dust density.

Willner, S. P.↗

Instrumentation for propulsion systems development

Various types of instrumentation for the development of propulsion systems are discussed. For the steady-state measurement of local temperature, pressure and flow velocity in gases the devices include: a multielement probe, calibrated thermocouple probes, thermocouple probes designed for low gas velocities, pressure measuring devices for high-speed rotors, and instruments for data pickup from rotating members. For the dynamic measurements of the same factors attention is given to 2-mm diameter pressure transducers, flush-diaphragm transducers, resistance thermometers or thermocouples, and miniature transducers for velocity measurements. Instruments for compressor and turbine-blade instrumentation are described with reference to a pyrometer for mapping turbine-blade surface temperature, a capacitance method for making rotor clearance measurements, and optical detection procedures for blade vibration amplitude.

Warshawsky, I.↗

The light curve of the nucleus of comet d'Arrest

This paper reports new photoelectric photometry of the nucleus of P/d'Arrest (1976e) during August 4, 5, and 6, 1976 (UT), just before perihelion passage. The comet appeared as a bright stellar nucleus with a faint surrounding coma. The average visual magnitude from the nuclear region (16-arcsec diaphragm) was 11.60. The visual brightness varies with an amplitude of 0.15 plus or minus 0.02 mag. There is evidence for a period of 5.17 plus or minus 0.01 hr. We interpret such a periodic variation as due to the rotation of the nucleus. The colors of the nuclear region are very similar to those of a solar-type star, and they do not vary significantly with aspect angle.

Fay, T. D., Jr.↗

Bifunctional gas-flow regulator

Simple modification converts conventional high-pressure regulator to combination pressure-regulator/shutoff valve. Modification entails adding second diaphragm and pressure compartment. Modified valve is switched between its two functions by external two-position low-pressure valve.

Koch, E. F.↗

Instrumentation for measuring the dynamic pressure on rotating compressor blades

To establish the capability for measurement of oscillatory pressure on rotating blades, miniature fast response semiconductor strain gage pressure transducers (2mm x 0.33mm) were mounted in several configurations on thin titanium and steel compressor blades and subjected to pressure cycles from 1 to 310 kPa during static tests and spin tests. Static test conditions included 20 C to 150 C, 0 to 3000 tensile microstrain, -1000 to +1000 bending microstrain and + or - 650G vibration. The spin test conditions included 20 C to 82 C at 0 to 90,000G. Durability was excellent. Pressure transducer sensitivity changed by only a few percent over this range of environmental conditions. Noise signal due to oscillatory acceleration normal to the diaphragm was acceptable (0.33Pa/G). Noise signal due to oscillatory strain was acceptable (0.5 Pa/microstrain) when the transducer was mounted on a 0.05mm rubber pad, with a total buildup of 0.38mm on the measure surface. Back mounting or partial recessing to eliminate buildup, increased the strain effect to 1.2 Pa/microstrain. Flush mounting within the blade to eliminate buildup reduced the strain effect, but required development of a special transducer shape. This transducer was not available in time for spin tests. Unpredictable zero drift + or - 14 kPa ruled out the use of these mounting arrangements for accurate steady-state (D.C.) measurements on rotating blades. The two best configurations fully developed and spin tested were then successfully applied in the NAS3-20606 rotating fan flutter program for quantitative measurement of oscillatory pressure amplitudes.

Grant, H. P.↗

Acoustic sensor engineering evaluation test report

Two types of one-inch diameter sound pressure level sensors, which are candidates for monitoring ambient noise in the shuttle orbiter crew compartment during rest periods, were exposed to temperature, passive humidity, and vibration. One unexposed sensor of each type served as a reference unit. Except for the humidity exposures, each of the three capacitive microphones was individually tested in sequence with the essential voltage power supply and preamplifier. One unit exibited anomalous characteristics after the humidity exposure but returned to normal after being dried in an oven at 115 deg for two hours. Except for the humidity exposures, each of the three piezoelectric microphones was individually tested with a laboratory type amplifier. Two apparent failures occurred during these tests. The diaphragm on one was found ruptured after the fourth cycle of the humidity test. A second sensor showed an anomaly after the random vibration tests at which time its sensitivity was consistent at about one-half its former value.

Phillips, E. L., Jr.↗

Measuring unsteady pressure on rotating compressor blades

Miniature semiconductor strain gage pressure transducers mounted in several arrangements were studied. Both surface mountings and recessed flush mountings were tested. Test parameters included mounting arrangement, blade material, temperature, local strain in the acceleration normal to the transducer diaphragm, centripetal acceleration, and pressure. Test results show no failures of transducers or mountings and indicate an uncertainty of unsteady pressure measurement of approximately + or - 6 percent + 0.1 kPa for a typical application. Two configurations were used on a rotating fan flutter program. Examples of transducer data and correction factors are presented.

Englund, D. R.↗

Retractable environmental seal

A retractable environmental seal for use in sealing the opening of the exit cone for a rocket nozzle is described. A diaphragm-like cover having a central region adapted to be seated in sealing relation with the periphery of the opening is discussed. Radially extended failure zones for facilitating a pressure-induced rupture of the cover, and a plurality of angularly spaced tension springs connected with the peripheral portion of the cover are characterized.

Dettling, J. R.↗

Ozone measurement system for NASA global air sampling program

The ozone measurement system used in the NASA Global Air Sampling Program is described. The system uses a commercially available ozone concentration monitor that was modified and repackaged so as to operate unattended in an aircraft environment. The modifications required for aircraft use are described along with the calibration techniques, the measurement of ozone loss in the sample lines, and the operating procedures that were developed for use in the program. Based on calibrations with JPL's 5-meter ultraviolet photometer, all previously published GASP ozone data are biased high by 9 percent. A system error analysis showed that the total system measurement random error is from 3 to 8 percent of reading (depending on the pump diaphragm material) or 3 ppbv, whichever are greater.

Tiefermann, M. W.↗

Apparatus and method of inserting a microelectrode in body tissue or the like using vibration means

An arrangement for and method of inserting a glass microelectrode having a tip in the micron range into body tissue is presented. The arrangement includes a microelectrode. The top of the microelectrode is attached to the diaphragm center of a first speaker. The microelectrode tip is brought into contact with the tissue by controlling a micromanipulator. Thereafter, an audio signal is applied to the speaker to cause the microelectrode to vibrate and thereby pierce the tissue surface without breaking the microelectrode tip. Thereafter, the tip is inserted into the tissue to the desired depth by operating the micromanipulator with the microelectrode in a vibratory or non-vibratory state.

Feldstein, C.↗

Support for joint infrared and Copernicus X-Ray observations of Cygnus X-3

Simultaneous X-ray and infrared measurements were carried out of the flares from Cygnus X-3 from the Copernicus spacecraft observatory. The detectors, InSb, were arranged so that 1.65 and 2.2 micrometer broadbend photometry was performed through a common diaphragm. The measurements were used to determine the energy distribution during a flare and thus learn about the infrared spectrum and its changes during the flare.

Source record↗