Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOSIMETRY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Preliminary Thermoluminescent Dosimeter Glow Curve Analysis with Automated Glow Peak Identification for LiF Mg,Ti

When appropriately analyzed, thermoluminescent dosimeter glow curve analysis allows for improved quantification of thermoluminescent material behavior while flagging abnormalities. The mathematical separation of a glow curve into contributions from energetically unique trap states, or glow curve analysis, may be used to remove undesired effects of signal fading for complex materials. A generalized glow curve analysis software for the separation of glow curves is presented in this paper. Written in C ++ , the software uses the first-order kinetics model with automatic peak identification. The automatic identification of peaks is achieved through a unique peak-finding algorithm. Here, the program was performance tested using experimental glow curve data from LiF:Mg,Ti, and comparative results are presented.

47 OTHER INSTRUMENTATION↗

Applying ALARA Principles in the Design of New Radiological Facilities

The application of ALARA (As Low As Reasonably Achievable) principles to the design of new radiological facilities at Argonne National Laboratory provides a consistent radiation safety basis for future facility operations. The Department of Energy Rule 10 CFR 835 specifies design objectives to be adopted during the design of new facilities for controlling personal radiation exposure. One is to keep exposure levels below 20% of the applicable standards in 10 CFR 835.202. For a radiation worker 20% of the standard corresponds to 5 µSv hr -1 for a 2,000 hour work year. For a member of the public the DOE design objective corresponds to 0.2 mSv in a calendar year. For a new facility worst case radionuclides and their source strengths are chosen. Local shielding is specified to reduce exposure rates to less than 50 µSv hr -1 at 30 cm from the shielding. The current version MCNP6 of the Los Alamos radiation shielding computer program MCNP is then used to calculate the exposure rates elsewhere. Design modifications are made to meet the criteria. The calculations and resulting facility design modifications are discussed for two new radiological facilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiological HEPA Filter 10-year Lifetime Evaluation in Research Facilities

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifetime deployment and its other performance indicators. This 10-year-long endeavor to collect and analyze data regarding the service life of HEPA filters at the Pacific Northwest National Laboratory began in 2010. A set of HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. The study has now been completed, and over the past decade all the HEPA filters have been replaced, due to either technical issues as listed in this report or the previously recommended filter “age limit” of 10 years as prescribed by the oversight bodies. Experimentally determined failure rates are also determined from the data set and can be used to estimate the chances of HEPA filters surviving 15, 20, or even 30 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

Alternate Analysis of an In Vitro Solubility Study on the Lung Dissolution Rate of 238PuO2 Material Involved in the 2020 Incident at Los Alamos National Laboratory

Here this work presents an alternate analysis of an in vitro solubility study on the lung dissolution rate of 238 PuO 2 material involved in a recent inhalation incident at Los Alamos National Laboratory (LANL). The original dataset used in this work was retrieved from a recently published report. The present work shows an analysis of the same dataset by modeling the dissolution in separate time intervals rather than modeling the cumulative dissolution.

238Pu↗

Methods to Account for CAP-88 PC-Omitted Nuclides in Radioactive Air Emissions From DOE Facilities

Routine research and development activities at US Department of Energy facilities can result in the release of radioactive emissions, potentially exposing the public and the environment. Such emissions are subject to certain Clean Air Act regulations, specifically those outlined in 40 CFR Part 61, Subpart H, which are enforced by the US Environmental Protection Agency. Compliance is determined in part with a dose standard. Doses to members of the public from most US Department of Energy facility airborne emissions are modeled using CAP-88 PC software, the latest version of which contains more than 1,200 radionuclides. Radioactive effluents from US Department of Energy facilities may contain radioisotopes that are not available in CAP-88 PC, and those radioisotopes must still be evaluated to determine whether doses to members of the public are below established limits. CAP-88 PC-omitted radionuclides can be accounted for using alternate methods, including the use of surrogate radionuclides. Here, this paper elucidates the process of accounting for CAP-88 PC-omitted radionuclides by providing criteria and rationale for surrogate selection, a compilation of surrogate radionuclides used in the past by US Department of Energy facilities, a discussion of alternate methods used to account for CAP-88 PC-omitted radionuclides and a comparison of methods and impacts on receptor doses. Ultimately, this paper aims to aid in the process of surrogate selection and consequently to simplify and expedite compliance with Clean Air Act regulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

Minimum Detectable Intakes and Doses for Uranium Bioassays—Comparison between Alpha Spectrometry and ICP-MS

Naturally occurring uranium complicates monitoring for occupational exposures. There are several retroactive methods that can be used to monitor for occupational exposures, with benefits and drawbacks to each. Analysis of uranium in urine by mass spectrometry and alpha spectrometry is compared, and methods of determining an occupational exposure are presented. Furthermore, the minimum detectable concentrations from each analysis and a method for intake determination based on the analytical results are compared for various solubility types and mixtures. Mass spectrometry with radiochemical separation was found to be the most sensitive analysis for detecting occupational exposures to anthropogenic mixtures based on minimum detectable doses calculated from the proposed method for intake determination.

bioassay↗

Conversion of Site-Specific Meteorological Data for use in CAP-88 PC

CAP-88 PC is a commonly used radiological atmospheric dispersion model. This US EPA-approved model is used to demonstrate compliance with atmospheric emission regulations for radionuclides. While the model includes a large library of meteorological data for use across the United States, there are applications when users may wish to use onsite meteorological data as an input to the CAP-88 PC model. Here, in this work, we present a work-around process for preparing and converting onsite data for use in CAP-88 PC. However, the use of local data should provide a more realistic estimate of doses to members of the public in the immediate vicinity of a facility, although the regulatory agency having jurisdiction may not accept the use of local data for compliance. Additionally, the historical meteorological records from 20+ years ago (at a site many kilometers away) might not be representative of current local weather patterns, highlighting another benefit of using local meteorological data.

54 ENVIRONMENTAL SCIENCES↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

The Systems of Radiological Protection for Ionizing and Non-Ionizing Radiation

This paper summarizes the presentations and panel discussion held at Plenary Session 1 of the 16th IRPA International Congress/69th Health Physics Society Annual Meeting, in Orlando, FL, in July 2024. Plenary Session 1 discussed the basics of the systems of radiological protection (RP) for ionizing radiation (IR) and non-ionizing radiation (NIR) and included five presentations and a panel discussion. Rodney Croft, Chair of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), delivered the first presentation. Croft introduced the System of RP for NIR and provided an overview of ICNIRP’s coverage and current areas of work. Werner Rühm, Chair of the International Commission on Radiological Protection (ICRP), delivered the second presentation. He gave an overview of the System of RP for IR and covered the key principles of justification, optimization, and dose limitation, including the current plans of ICRP toward the envisaged revision of the System of RP. The third speaker, Sigurður Magnús Magnússon, from the International Radiation Protection Association (IRPA), provided the perspective of the RP professionals on the development of the Systems of RP for IR and NIR. Emilie van Deventer, from the World Health Organization (WHO), presented WHO’s views of both Systems of RP and discussed the relevant current activities of WHO with regard to IR and NIR. Kathryn Higley, President of the National Council on Radiation Protection and Measurements (NCRP), delivered the final presentation. Higley outlined the history of NCRP, the differences between ICRP and NCRP, and discussed the role of the NCRP in the System of RP, including NCRP’s role to analyze mechanisms of interaction of NIR with biological systems, including humans. The session concluded with a fruitful panel discussion, where the audience had the opportunity to ask the five invited speakers questions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Enhancing Distribution Grid Resilience Through Model Predictive Controller Enabled Prioritized Load Restoration Strategy

Effective resilience improvement strategies enable the power grid to cope with disruptive extreme events. Most power grid outages are caused by disruptions in distribution grids. Motivated by the urgent need for power system resilience research, this paper proposes a priority-weighted optimal load restoration technique to enhance the resilience of distribution grids against extreme events. The proposed technique is based on smart distribution technology and framed as sequential multi-step decision process (MDP) and mixed integer linear program (MILP). It is formulated as optimal control problem with a model predictive control (MPC) approach. We applied the devised MILP-MPC-based load restoration technique to a simplified single-bus version of the IEEE 13-bus distribution system with integrated distributed energy resources (DERs) such as wind turbine, photovoitaic array, microturbine, and energy storage device. The technique executes a reducing and rolling horizon optimization in each control step in real-time using the forecasted information of the renewables, the fuel status of the microturbine and the state of charge of the energy storage device. We consider an extreme event which triggered outage of the upstream utility grid and caused islanded operation of the distribution grid. We demonstrated the effectiveness of the proposed MPC approach in restoring the distribution grid loads based on their priority during the main grid outage-caused islanded operation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experiments to Quantify the Shielding Efficacy of Materials to be Implemented for Portable Shielding Enclosures that Adequately Mitigate EMI from Lighting Attachment Events

Mitigating electric and magnetic fields induced by lightning strike events is critical for the security and longevity of electrical components. Electromagnetic interference originating from a lightning strike is categorized into the low to medium frequency ranges, commonly referred to as the “magnetic coupling” regime. This low-frequency characteristic brings about the problem of shielding magnetic flux lines. Such shielding can be accomplished with highly conductive materials via the generation of eddy currents or by diverting the flux lines using materials with a large relative permeability. The shielding effectiveness of materials with varying thicknesses and geometry are tested using a pulse forming network having comparable characteristics to a scaled lighting strike. A four-stage Marx generator with a peak current of ~33 kA and a risetime of 1.4 μs is used as the pulse forming network to emulate the scaled electric and magnetic fields. The data collected from these experiments provide information and techniques that can be implemented into the design of a portable, deployable shielding enclosure.

61 RADIATION PROTECTION AND DOSIMETRY↗

Restoring Distribution System Under Renewable Uncertainty Using Reinforcement Learning

Distributed energy resources (DERs) in distribution systems, including renewable generation, micro-turbine, and energy storage, can be used to restore critical loads following extreme events to increase grid resiliency. However, properly coordinating multiple DERs in the system for multi-step restoration process under renewable uncertainty and fuel availability is a complicated sequential optimal control problem. Due to its capability to handle system non-linearity and uncertainty, reinforcement learning (RL) stands out as a potentially powerful candidate in solving complex sequential control problems. Moreover, the offline training of RL provides excellent action readiness during online operation, making it suitable to problems such as load restoration, where in-time, correct and coordinated actions are needed. In this study, a distribution system prioritized load restoration based on a simplified single-bus system is studied: with imperfect renewable generation forecast, the performance of an RL controller is compared with that of a deterministic model predictive control (MPC). Our experiment results show that the RL controller is able to learn from experience, adapt to the imperfect forecast information and provide a more reliable restoration process when compared with the baseline controller.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Deep Multitask Learning Models for Radiation Estimation at High Energy Accelerator Facility

Controlling the dose of radiation exposure in potential radioactive facilities is critical for ensuring the safety of staff and the public. Here, in this paper, we developed machine learning models to estimate radiation exposure efficiently at the Thomas Jefferson National Accelerator Facility (JLab), aiming to enhance safety in both accelerator facilities and public areas. Multiple sensors were deployed around the three experimental halls at JLab. Data on single-beam currents, energy levels, and radiation values at the sensor locations were collected during accelerator operation. We proposed a multi-task learning model for radiation estimation, utilizing either one-dimensional convolutional neural networks (1-D CNNs) or long short-term memory networks (LSTMs) as the backbone. The proposed model was trained to simultaneously estimate radiation levels at the sensor locations. Experimental results demonstrated that the proposed model with LSTM backbone achieved the best estimation performance, with an average R 2 score of 0.7557 for estimation within the same year and 0.7157 for estimation across different years. These results significantly surpassed those of competing models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

History of Pu-238 Production Restart Efforts at Idaho National Laboratory and Oak Ridge National Laboratory

In the early 2010s, efforts to restart production in the U.S. of plutonium-238 heat source (HSPu) material for NASA deep space missions were initiated. Processes, procedures, hardware, and chemical separations were developed and implemented to enable the production of heat source material at Oak Ridge National Laboratory (ORNL) and Idaho National Laboratory (INL). Here, this review provides an overview of the timeline and efforts associated with the restart of production, as well as upcoming efforts to increase production.

07 ISOTOPE AND RADIATION SOURCES↗