Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Laser diagnostics to characterize the in-flame growth of platinum nanoparticles manufactured by the reactive spray deposition technology

Reactive Spray Deposition Technology (RSDT) is an atmospheric pressure, flame-based advanced manufacturing method used to fabricate Membrane Electrode Assemblies (MEAs) for proton exchange fuel cells and water electrolyzers. RSDT combines the flame synthesis of catalyst nanoparticles and their deposition onto the membrane in one step. The properties of the synthesized nanoparticles, such as their Size Distribution Function (SDF), determine the manufactured electrodes’ performance, which can be evaluated when the deposition is complete via ex-situ characterization of the products. Efforts to improve RSDT for manufacturing state-of-the-art MEAs can be significantly enhanced with integrated laser diagnostics that enable in situ measurement of the synthesized catalyst nanoparticles. This paper reports the implementation of laser diagnostics in an RSDT facility and evaluates their potential to assist the manufacturing process. Laser Light Scattering (LS) and Laser-Induced Incandescence (LII) measurements are performed in the oxygen-rich zone of the flame at various distances from the flame fuel jet nozzle downstream of its luminous region. The measurements quantitatively track the evolution in size and volume fraction of platinum-based nanoparticles in two flames that yield different catalytic properties in the manufactured electrodes. The profiles of the measured nanoparticles’ volume fraction along the flame axis can be estimated a priori so that the average nanoparticle sizes can be measured in quasi-real time via LS. Nanoparticles experience an extremely slow growth rate while being convected at distances from 150 nm to 300 nm from the fuel nozzle. Complementary characterizations of the synthesized nanoparticles are performed ex-situ via High-Angle Annular Darkfield Scanning Transmission Electron Microscopy (HAADF-STEM) image analyses of samples collected on grids at a fixed distance from the fuel jet nozzle. Comparing the results from laser and microscopy techniques not only cross-validates the findings but also provides the parameters to infer the bimodal SDF in-situ and yields evidence that the coagulation efficiency of the synthesized nanoparticles has extremely low values in the investigated zone of the flames.

Rayleigh Light Scattering (LS)↗

Jacobian-based model diagnostics and application to equation oriented modeling of a carbon capture system

It can be difficult to identify the specific variables or equations responsible for convergence issues in large mathematical programming models. The Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES-IP) contains a tool to identify poorly scaled constraints and variables by searching for rows and columns of the Jacobian matrix with small L2-norms. A singular value decomposition is then performed to identify degenerate sets of equations and remaining scaling issues. Here, this work presents a flowsheet developed for post-combustion carbon capture using a monoethanolamine (MEA) solvent system as a case study. This work takes the reader through the entire process of model diagnostics and reformulation, from a basic introduction to the mathematics behind these model diagnostics to the reformulations necessary to make the model numerically robust, including a significantly modified enhancement factor model.

IDAES↗

High-power non-perturbative laser delivery diagnostics at the final focus of 100-TW-class laser pulses

Controlling the delivery of multi-terawatt and petawatt laser pulses to final focus, both in position and angle, is critical to many laser applications such as optical guiding, laser–plasma acceleration, and laser-produced secondary radiation. We present an online, non-destructive laser diagnostic, capable of measuring the transverse position and pointing angle at focus. The diagnostic is based on a unique double-surface-coated wedged-mirror design for the final steering optic in the laser line, producing a witness beam highly correlated with the main beam. By propagating low-power kilohertz pulses to focus, we observed spectra of focus position and pointing angle fluctuations dominated by frequencies below 70 Hz. The setup was also used to characterize the excellent position and pointing angle correlation of the 1 Hz high-power laser pulses to this low-power kilohertz pulse train, opening a promising path to fast non-perturbative feedback concepts even on few-hertz-class high-power laser systems.

47 OTHER INSTRUMENTATION↗

Methods to Evaluate Subcolumn Profiles Based on Two-Point Diagnostics

In atmospheric models, stochastic generation of subgrid-scale profiles or “subcolumns” has been used for a variety of purposes. Such subcolumns can be generated from subgrid probability density functions (PDFs) at different vertical levels, when such PDFs are available. To do so, the generator needs to decide how strongly points should be correlated in the vertical, that is, how much the values should be overlapped. This is sometimes called “PDF overlap.” To assess vertical correlation in a simplified, observable setting, here the vertical correlation of vertical velocity in subcloud layers is examined. Doppler lidar is used to evaluate the vertical profiles of vertical velocity produced by a large-eddy simulation (LES) model and the Subgrid Importance Latin Hypercube Sampler (SILHS) subcolumn generator. In order to diagnose unrealistic features in subcolumn profiles, various statistical diagnostics are examined here, including the bivariate PDF of vertical velocity at two separated points (i.e., altitudes), the two-point velocity correlation, the integral correlation length, the PDF of two-point velocity differences, and the skewness and kurtosis of two-point velocity differences. The profiles produced by LES match lidar well, except that they are too smooth at small scales. The profiles produced by SILHS exhibit sharp jumps from updraft to downdraft that are not observed in the lidar data. To reduce the generation of these unrealistically sharp jumps, the SILHS sampling method is revised. The diagnostics confirm that the revised sampling method reduces the overprediction of sharp jumps.

54 ENVIRONMENTAL SCIENCES↗

Probabilistic machine learning for battery health diagnostics and prognostics—review and perspectives

Abstract Diagnosing lithium-ion battery health and predicting future degradation is essential for driving design improvements in the laboratory and ensuring safe and reliable operation over a product’s expected lifetime. However, accurate battery health diagnostics and prognostics is challenging due to the unavoidable influence of cell-to-cell manufacturing variability and time-varying operating circumstances experienced in the field. Machine learning approaches informed by simulation, experiment, and field data show enormous promise to predict the evolution of battery health with use; however, until recently, the research community has focused on deterministic modeling methods, largely ignoring the cell-to-cell performance and aging variability inherent to all batteries. To truly make informed decisions regarding battery design in the lab or control strategies for the field, it is critical to characterize the uncertainty in a model’s predictions. After providing an overview of lithium-ion battery degradation, this paper reviews the current state-of-the-art probabilistic machine learning models for health diagnostics and prognostics. Details of the various methods, their advantages, and limitations are discussed in detail with a primary focus on probabilistic machine learning and uncertainty quantification. Last, future trends and opportunities for research and development are discussed.

25 ENERGY STORAGE↗

Examination of synthetic gas puff imaging diagnostic data from a gyrokinetic turbulence code

A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of microwave broadband CMOS transmitter and receiver circuits for MIR and ECEI plasma diagnostics

To efficiently determine the plasma electron density fluctuations using the MIR diagnostic technique, a 55–75 GHz 65 nm-CMOS transmitter has been developed where four separate intermediate frequency (IF) signals are up-converted, amplified, and then combined to generate an 8-tone RF output; a broadband 90 nm-CMOS receiver has also been constructed, which consists of an RF-low noise amplifier (LNA), mixer, and IF amplifier. The circuits and their corresponding modules will soon be deployed on the DIII-D and NSTX-U fusion devices. A 110–140 GHz 65 nm-CMOS receiver has also been designed, which is suitable for measuring the deep-core temperature fluctuations in the DIII-D tokamak using the electron cyclotron emission imaging diagnostic system. In addition to the RF-LNA/balun, mixer, and IF amplifier, an LO balun/tripler and driving amplifier are now included in this highly integrated circuit chip. By adopting the microwave and millimeterwave system-on-chip concept in the front-end system design, this paper demonstrates that compact transmitter and receiver modules can be easily built, which, in turn, facilitates array implementation and maintenance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upgrades to the ion cyclotron emission diagnostic on the DIII-D tokamak

The ion cyclotron emission diagnostic on the DIII-D tokamak comprises seven single-turn loops that measure high-frequency (1–100 MHz) magnetic field fluctuations that are often excited by energetic particles in the plasma. The raw voltage signals induced in the loops in response to these fluctuations travel through a series of cables, isolation transformer DC blocks, low-pass filters, and finally a digitizer before being analyzed in frequency space. The diagnostic has been recently upgraded, most notably to include four additional graphite tile loops and a new eight-channel digitizer. The previous three loops are all on the low-field side of the tokamak. The measurement capabilities of the system have been expanded by the addition of a new horizontally oriented loop on the low-field side, an additional toroidal loop on the low-field side, and two toroidal loops on the high-field side. These loops will be used to provide approximate mode polarization, improved toroidal mode number calculations, and information on modes in inward-shifted plasmas, respectively.

47 OTHER INSTRUMENTATION↗

Calibration of a versatile multi-energy soft x-ray diagnostic for WEST long pulse plasmas

A compact multi-energy soft x-ray diagnostic is being installed on the W Environment in Steady-state Tokamak (WEST), which was designed and built to test ITER-like tungsten plasma facing components in a long pulse (~1000 s) scenario. The diagnostic consists of a pinhole camera fielded with the PILATUS3 photon-counting Si-based detector (≲100 kpixel). The detector has sensitivity in the range 1.6–30 keV and enables energy discrimination, providing a higher energy resolution than conventional systems with metal foils and diodes with adequate space and time resolution (≲1 cm and 2 ms). The lower-absorption cut-off energy is set independently on each one of the ~100 kpixels, providing a unique opportunity to measure simultaneously the plasma emissivity in multiple energy ranges and deduce a variety of plasma parameters (e.g., T e , n Z , and ΔZ eff ). The energy dependence of each pixel is calibrated here over the range 3–22 keV. The detector is exposed to a variety of monochromatic sources—fluorescence emission from metallic targets—and for each pixel, the lower energy threshold is scanned to calibrate the energy dependence. The data are fit to a responsivity curve (“S-curve”) that determines the mapping between the possible detector settings and the energy response for each pixel. Here, the calibration is performed for three energy ranges: low (2.3–6 keV), medium (4.5–13.5 keV), and high (5.4–21 keV). We determine the achievable energy resolutions for the low, medium, and high energy ranges as 330 eV, 640 eV, and 950 eV, respectively. The main limitation for the energy resolution is found to be the finite width of the S-curve.

47 OTHER INSTRUMENTATION↗

Optimization of the gamma reaction history diagnostic for double-shell pusher areal density and reaction history measurements on the National Ignition Facility

The double-shell inertial confinement fusion campaign, which consists of an aluminum ablator, a foam cushion, a high-Z pusher (tungsten or molybdenum), and liquid deuterium–tritium (DT) fuel, aims for its first DT filled implosions on the National Ignition Facility (NIF) in 2024. The high-Z, high density pusher does not allow x-rays to escape the double-shell capsule. Therefore, nuclear diagnostics such as the Gamma Reaction History (GRH) diagnostic on the NIF are crucial for understanding high-Z implosion performance. To optimize the GRH measurement of fusion reaction history and the pusher’s areal density, the MCNP6.3-based forward model of the detector was built. When calculating the neutron-induced inelastic gamma ray production, the interaction of neutrons with the compressed fuel was additionally included. By folding the calculated gamma ray spectrum output and the previously calibrated GRH detector responses, the optimum set of GRH energy thresholds for measuring the pusher areal density is determined to be 2.9 and 6.3 MeV for DT double-shell experiments. In addition, the effect of the down-scattering of neutrons on the gamma ray spectrum, the minimum required yield for measurements, and the attenuation of the gamma rays through the pusher are analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

A new synthetic correlation electron cyclotron emission diagnostic for validating nonlinear gyrokinetic simulations of electron temperature turbulence

To validate nonlinear gyrokinetic simulations of electron temperature turbulence, the experimental correlation electron cyclotron emission (CECE) measurements are to be compared using a synthetic CECE diagnostic, which generates modeled CECE measurement quantities by implementing realistic measurement parameters (e.g., spatial and wavenumber resolutions, radial location, etc.) to nonlinear gyrokinetic simulations. In this work, we calculate the radial and vertical spatial and wavenumber transfer functions, which are defined by the electron cyclotron emission emissivity radial profile and vertical probing antenna pattern, respectively. These transfer functions are applied to nonlinear gyrokinetic simulations of electron temperature turbulence using the continuum gyrokinetic code. A simultaneous comparison of the experimental electron temperature turbulence power spectrum and root-mean-square (RMS) level, as well as the radial correlation length with the new synthetic CECE diagnostic at a core location ρ ∼ 0.75 in an L-mode DIII-D tokamak plasma, is presented. Here, the preliminary result shows that the synthetic CECE output underestimates the RMS level by ∼42% and overestimates the radial correlation length by ∼40%.

Cyclotron radiation↗

LAMP Diagnostics at the Point-of-Care: Emerging Trends and Perspectives for the Developer Community

Over the past decade, loop-mediated isothermal amplification (LAMP) technology has played an important role in molecular diagnostics. Amongst numerous nucleic acid amplification assays, LAMP stands out in terms of sample-to-answer time, sensitivity, specificity, cost, robustness, and accessibility, making it ideal for field-deployable diagnostics in resource-limited regions. In this review, we outline the front-end LAMP design practices for point-of-care (POC) applications, including sample handling and various signal readout methodologies. Next, we explore existing LAMP technologies that have been validated with clinical samples in the field. We summarize recent work that utilizes reverse transcription (RT) LAMP to rapidly detect SARS-CoV-2 as an alternative to standard PCR protocols. Finally, we describe challenges in translating LAMP from the benchtop to the field and opportunities for future LAMP assay development and performance reporting. Despite the popularity of LAMP in the academic research community and a recent surge in interest in LAMP due to the COVID-19 pandemic, there are numerous areas for improvement in the fundamental understanding of LAMP, which are needed to elevate the field of LAMP assay development and characterization.

60 APPLIED LIFE SCIENCES↗

Liquid Metal Diagnostics

Liquid metal (LM) plasma-facing components (PFCs) (LM-PFCs) within next-generation fusion reactors are expected to enhance plasma confinement, facilitate tritium breeding, improve reactor thermal efficiency, and withstand large heat and particle fluxes better than solid components made from tungsten, molybdenum, or graphite. Some LM divertor concepts intended for long-pulse operation at >20 MW/m 2 incorporate thin (~1 cm), fast-moving (~5 to 10 m/s), free-surface flows. Such systems will require a range of diagnostics to monitor and control the velocity, flow depth, temperature, and impurity concentration of the LM. As such, this paper will highlight technologies developed for the fission and casting/metallurgical industries that can be adapted to meet the needs of LM-PFC research. This paper is divided into four major parts. The first part will look at noncontact flowmeter technologies that are suitable for high-temperature alkali metal systems. These technologies include rotating Lorentz-force flowmeters for bulk flow rate measurements and particle tracking techniques for surface velocity measurements. Second, this paper will detail the operation of a new inductive level sensor that can be used within free-surface LM-PFCs. This robust level sensor can be mounted below the substrate that supports the LM, so it is simple to install and is protected from the damaging conditions inside a fusion reactor. It has been shown that this level sensor can be calibrated using either numerical or experimental techniques. Third, distributed temperature sensors based on fiber-optic technologies will be discussed. This advanced measurement technique provides temperature data with high spatial resolution and has recently been successfully tested in LM systems. Last, diagnostics to measure impurity concentration, such as electrochemical cells, plugging meters, and spectroscopic systems, will be addressed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observations of xenon spectra on the EAST x-ray crystal spectrometer for high-temperature plasma diagnostics

The Xe 44+ 2.7203 Å line, which has been proposed as one of the diagnostic lines for the x-ray imaging crystal spectrometer on ITER, is observed on the EAST tokamak together with its several satellite lines. The observations are made under high electron temperature (T e ) conditions (core T e > 5 keV). Most of the observed xenon lines are identified by comparing the experiment results with the atomic simulation results. The first ion temperature measurements made by the xenon spectra on EAST are also reported in this article. These xenon spectra observations contribute to the justification for using xenon as the diagnostic impurity in x-ray crystal spectrometers in future reactor-scale high-temperature plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Blade Designs For Improved Multi-Phase Performance In sCO 2 Compressors; Part II - Optical Diagnostics In sCO 2 And Experimental Evaluation With Particle Image Velocimetry

This paper presents the second part of a study in which the leading-edge and suction surface of a compressor blade was modified to delay onset of phase change for sCO 2 compressors operating near the critical point. Using a first-of-its-kind apparatus for the measurement of sCO 2 flow fields, Particle Image Velocimetry (PIV) is used for local flow field measurements of two compressor blade geometries: the modified “biased-wedge,” and a conventional constant thickness blade. Utilizing the developed hardware, the feasibility of a simple, laser-based diagnostic for qualitatively measuring liquid phase regions, is also presented. The design of the optical diagnostics rig, a discussion of numerous challenges, and necessary considerations involved in performing optical-based measurements like PIV, in sCO 2 , are discussed. Velocity field measurements for the modified compressor profile show a much lower suction peak compared to a conventional blade. Furthermore, these results validate numerical results at the tested conditions, where the suction side profile of the biased wedge works to minimize the local pressure gradient.

14 SOLAR ENERGY↗

Development of HEK-293 Cell Lines Constitutively Expressing Flaviviral Antigens for Use in Diagnostics

Flaviviruses are important human pathogens worldwide. Diagnostic testing for these viruses is difficult because many of the pathogens require specialized biocontainment. To address this issue, we generated 39 virus-like particle (VLP)- and nonstructural protein 1 (NS1)-secreting stable cell lines in HEK-293 cells of 13 different flaviviruses, including dengue, yellow fever, Japanese encephalitis, West Nile, St. Louis encephalitis, Zika, Rocio, Ilheus, Usutu, and Powassan viruses. Antigen secretion was stable for at least 10 cell passages, as measured by enzyme-linked immunosorbent assays and immunofluorescence assays. Thirty-five cell lines (90%) had stable antigen expression over 10 passages, with three of these cell lines (7%) increasing in antigen expression and one cell line (3%) decreasing in antigen expression. Antigen secretion in the HEK-293 cell lines was higher than in previously developed COS-1 cell line counterparts. These antigens can replace current antigens derived from live or inactivated virus for safer use in diagnostic testing.

59 BASIC BIOLOGICAL SCIENCES↗

FY19 L2 MRT 6744 Milestone Completion: Digital Time-Resolved Spot Diagnostic (D-TRSD)

This milestone report describes development of the Digital Time-Resolved Spot Diagnostic (D-TRSD) into a functioning diagnostic that has been proven in the laboratory. Laboratory tests complete the MRT 6744 exit criteria with the recording and analysis of a spot size measurement for two consecutive pulses on a two-pulse source. Additional channels will be added in the near future to provide an 84-channel measurement capability. The new modular design is more portable than the previous generations and will be much easier to set up at radiographic facilities across the complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗