Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diffractive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Optical design and efficiency measurement of an extreme ultraviolet high-resolution spectrometer for unresolved transition array research

Understanding the structures of the unresolved transition array (UTA) observed in extreme ultraviolet (EUV) spectra from many-electron atoms is crucial for various applications, including fusion science and nanolithography. Here, to measure the fine structure of the UTA from tungsten and tin at around 5 and 13.5 nm at the Tokyo electron beam ion trap, we developed a high-resolution EUV spectrometer. The designed spectrometer achieves a resolving power of λ/dλ > 5000 at 5 and 13.5 nm. The fabricated large-area grating was experimentally examined at beamline BL5B of the UVSOR synchrotron facility to evaluate the diffraction efficiencies and their variation across the ruled area. The measured diffraction efficiencies are 0.65% ± 0.07% at 5 nm (second order) and 7.9% ± 0.2% at 13.5 nm (first order). The variation in the diffraction efficiency across the ruled area is 2.2%, 13.6%, and 10.0% in zeroth, first, and second order diffractions, respectively. The discrepancies in diffraction efficiencies between the experiments and the calculations were 5.2%, 29%, and 35% for the zeroth, first, and second diffraction orders, respectively.

47 OTHER INSTRUMENTATION↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

Detector pixel calibration of time-of-flight neutron diffractometers accelerated by machine learning

Modern time-of-flight neutron diffractometers at spallation neutron source are equipped with two dimensional detectors with fine pixelations. The flight path of neutrons from the moderator to the sample and to the detector needs to be precisely calibrated at detector pixel level using standard powders so the diffraction data from all the detector pixels can be correctly time-focused to produce high resolution diffraction peaks. The number of pixels can reach to millions which makes a single-pixel calibration process time-consuming, or even impossible, with conventional fitting routine. Here we presented a machine learning aided calibration process via a “training and predict” process by training machine learning models with the relations between the individual pixel time-of-flight diffraction pattern and fitted diffraction constant. The training models take a portion of the available pixels to predict the diffraction constants precisely and rapidly for massive pixel diffraction patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative measurements of dislocations in metals for advancing predictive simulations

LLNL applications require scientists to predict how materials evolve under various thermomechanical conditions. While this is achieved through physics-based simulations, uncertainty in the predictions of mechanical properties remains a serious challenge that limits the predictive capabilities of models because we lack methods to compare predictions of atomic-scale defects (dislocations) with experimental measurements. High energy X-ray diffraction (HEXRD) is the most relevant technique that can provide the necessary statistical information on dislocations. However, this technique is not yet quantitative because we lack a precise understanding of the relationship between X-ray diffraction patterns and the underlying material dislocation content and arrangements. To address this need, we used our novel computational X-ray diffraction method to simulate the effect of dislocations on the diffraction patterns. We compared virtual and experimental diffraction patterns. Results allowed us to clearly establish the relationship between X-ray diffraction patterns and the underlying dislocation structures, proving that it is feasible to quantitatively measure dislocation statistics with HEXRD. This project delivered a method that can provide the missing piece to LLNL’s mechanical property simulations in advanced metals by obtaining experimentally long-needed quantitative dislocation data, which could fully enable predictive capabilities.

36 MATERIALS SCIENCE↗

Temperature-tuned ultrafast X-ray shutter using optics-on-a-chip

Typically modulation systems are incapable of performing synchronous modulation for high-energy radiation systems. A method and system for performing high-energy synchronous radiation modulating is described. The method includes providing an oscillatory diffractive element, with the oscillatory diffractive element capable of being oscillated over a range of angles. A radiation source provides radiation to the oscillatory diffractive element. An electrical signal is provided to electrodes that oscillate the oscillatory diffractive element to modulate the radiation. A temperature controller controls the temperature of the oscillatory diffractive element to tune the oscillatory motion of the oscillatory diffractive element.

Wang, Jin↗

Dissecting Disorder: Defect-Driven Structural Complexity in Layered Li3InCl6 Solid Electrolyte

Halide solid electrolytes have emerged as promising candidates for solid-state batteries owing to their high oxidative stability and ionic conductivity. Among them, Li3InCl6 (LIC) has attracted significant attention. However, diffraction patterns of LIC synthesized via different methods exhibit distinct differences particularly at low-angle reflectionsindicative of underlying structural disorder. These variations are attributed to deviations from ideal crystallographic order, especially stacking faults, whose impact on structure and ion transport remains poorly understood. Here, we identify and quantify stacking faults in LIC samples prepared under different synthetic conditions. Using X-ray diffraction and time-of-flight neutron diffraction, we construct and refine stacking fault models that accurately reproduce the experimental diffraction features. LIC samples with higher degrees of stacking faults exhibit only negligible differences in ionic conductivities and activation energies. This indicates that stacking faults have a limited impact on altering the Li+ diffusion pathway along the c-axis, likely due to the high concentration of vacancies in the In layers, while Li+ diffusion remains nearly unchanged in the ab-plane. Our results account for the observed differences in diffraction patterns across samples and provide a quantitative assessment of faulting probabilities and stacking sequences. The insights gained from this study are expected to be broadly applicable to other layered halide solid electrolytes and contribute to a deeper understanding of the role of structural disorder in ion transport.

Liu, Jue [ORNL] (ORCID:000000024453910X)↗

Single-Crystal Diffuse Neutron Scattering Study of the Dipole-Octupole Quantum Spin-Ice Candidate Ce 2⁢ Zr 2 ⁢O 7 : No Apparent Octupolar Correlations Above 𝑇 = 0.05 K

The insulating magnetic pyrochlore Ce 2 ⁢Zr 2 ⁢O 7 has gained attention as a quantum spin-ice candidate with dipole-octupole character that arises from the crystal-electric-field ground-state doublet for the Ce 3+ Kramers ion. This dipole-octupole character permits both spin-ice phases based on magnetic dipoles and those based on more-exotic octupoles. This work reports low-temperature neutron diffraction measurements on single-crystal Ce 2 ⁢Zr 2⁢ O 7 with 𝑄 coverage both at low 𝑄, where the magnetic form factor for dipoles is near maximal, and at high 𝑄, covering the region where the magnetic form factor for Ce 3+ octupoles is near maximal. This study was motivated by recent powder neutron diffraction studies of other Ce-based dipole-octupole pyrochlores, Ce 2 ⁢Sn 2 ⁢O 7 and Ce 2 ⁢Hf 2 ⁢O 7 , which each showed temperature-dependent diffuse diffraction at high 𝑄, interpreted as arising from octupolar correlations. Our measurements use an optimized single-crystal diffuse scattering instrument that allows us to screen against strong Bragg scattering from Ce 2 ⁢Zr 2 ⁢O 7 . The temperature-difference neutron diffraction reveals a low-𝑄 peak consistent with dipolar spin-ice correlations reported in previous work, and an alternation between positive and negative net intensity at higher 𝑄. These features are consistent with our numerical-linked-cluster calculations using pseudospin interaction parameters previously reported for Ce 2 ⁢Zr 2⁢ O 7 , Ce 2 ⁢Sn 2 ⁢O 7 , and Ce 2 ⁢Hf 2 ⁢O 7 . Importantly, neither the measured data nor any of the NLC calculations show evidence for increased scattering at high 𝑄 resulting from octupolar correlations. We conclude that at the lowest attainable temperature for our measurements (𝑇 = 0.05 K), scattering from octupolar correlations in Ce 2 ⁢Zr 2 ⁢O 7 is not present in the neutron diffraction signal on the level of our observation threshold of around 0.1% of the low-𝑄 dipole scattering. We compare these results to those obtained earlier on powder Ce 2 ⁢Sn 2 ⁢O 7 and Ce 2⁢ Hf 2⁢ O 7 , and to low-energy inelastic neutron scattering from single-crystal Ce 2 ⁢Zr 2 ⁢O 7 .

36 MATERIALS SCIENCE↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

Status Report on Design of In-situ Thermomechanical Testing at LANSCE

Nuclear fuel encounters severe thermomechanical environments in which its mechanical response is determined by its microstructure, temperature and stress level histories. Simulating the response of such microstructures is crucial for predicting both performance and transient fuel mechanical responses and experimental verification of such predictions is therefore of great interest. While most of the deformation in a nuclear fuel rod occurs in the cladding, deformation of the fuel itself is still of interest with deformation mechanisms at operating temperature and above including creep, swelling, cracking as well as pellet-clad interaction. Characterization of these properties and understanding of the underlying deformation phenomena at operating or excursion temperatures is therefore of great importance for development and ultimately licensing of improved and novel nuclear fuel forms. Diffraction techniques offer unique insight on the atomistic (e.g. crystal structure) and microstructure (e.g. phase transformations, texture, defects) length scales and have a long history of providing unique data to inform relevant deformation models that enable the required predictive capabilities. For example, dislocations lead to diffraction peak broadening that can be characterized to estimate the dislocation density and study the role of dislocations on the deformation while measuring lattice strains allows to studie load sharing in two phase materials. In this report the requirements for a sample environment for high temperature deformation of nuclear fuels are defined. The HIPPO neutron time-of-flight diffractometer at LANSCE will host this sample environment and is also described. This instrument covers diffraction angles from 140° to 40° and is also equipped with an event-mode neutron imaging detector system, enabling energy-resolved neutron imaging in parallel with the diffraction that could measure sample temperature from Doppler broadening of neutron absorption resonances or measure pore densities from changes in the attenuation. Designs of devices to characterize thermomechanical properties of nuclear fuel without diffraction are also considered to guide the design. While this report is focused on applications for nuclear fuels, the device can also characterize cladding, moderator or structural materials and therefore contribute to other fields of research and development for advanced reactors. The temperatures planned to be reached are above 2000℃, thus enabling characterization of LWR reactor fuels under accident scenarios but also reaching temperatures of fuels developed for nuclear thermal propulsion and providing opportunities to characterize those. In conjunction with the energy-resolved neutron imaging detector, this setup would allow to measure neutron cross-sections at high temperatures, filling a gap towards development of reactors operating at high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiscale investigation of thermomechanical and compositional developments in Ni alloy 718 under laser processing

Laser processing has been widely employed in various applications due to its exceptional spatial resolution. However, the rapid temperature gradients generated in localized areas present significant challenges for experimental characterization using conventional instruments. To characterize Ni alloy 718 during laser processing, we employed in-situ synchrotron X-ray diffraction with a high-speed detector, a method particularly well-suited for probing processes with high temporal and spatial resolution. Through a series of in-situ experiments, we investigated the local variations in the evolution of microstructures and thermomechanical behaviors within a keyhole mode melt pool. The in situ macroscopic thermomechanical behaviors were quantified using an empirical model derived from diffraction patterns, with experimental results showing reasonable agreement with finite element analysis. Various laser parameters were tested to assess their influences on the residual strains in the melt pools. The results revealed that the residual strain in the keyhole mode melt pool is relatively insensitive to variations in the parameters and is smaller than that in the melt pool created under conduction mode laser scanning. Additionally, we analyzed the shapes of individual diffraction spots, providing insights into the plastic behaviors and compositional developments in the resolidified alloy. The analysis confirmed that compositional variations in a dendritic microstructure manifest as asymmetric broadening of the diffraction spots.

Ni alloy 718↗

Venturing into Unexplored Phase Space: Synthesis, Structure, and Properties of MgCo 3 B 2 Featuring a Rumpled Kagomé Network

MgCo 3 B 2 , a novel ternary boride in a previously unexplored phase space, was synthesized using the hydride route. In situ powder X-ray diffraction and DFT calculations aided in the discovery of this compound, whose structure was then determined by single-crystal X-ray diffraction. Like the closely related CeCo 3 B 2 , MgCo 3 B 2 crystallizes in centrosymmetric space group P6/mmm (a = 4.883(2) Å, c = 2.926(2) Å at 210 K, Z = 1). Unlike CeCo 3 B 2 , however, it adopts a disordered structure that features a rumpled Kagomé network of Co atoms, and Mg atoms fill the channels of a Co–B framework. Although the structural disorder leads to motifs that are similar to those observed in MgNi 3 B 2 and other related ternary borides, no evidence of an ordered superstructure was found by single-crystal X-ray diffraction or high-resolution powder X-ray diffraction. In the case of CeCo 3 B 2 , boron atoms occupy the center of regular Co 6 trigonal prisms; in MgCo 3 B 2 , boron atoms are shifted from the center of the prism to form B–B dimers with roughly the same length as those found in MgNi 3 B 2 . Magnetic susceptibility data exhibit an unusual temperature dependence that cannot be convincingly modeled by the modified Curie–Weiss equation, consistent with DFT calculations predicting a nonmagnetic ground state. Intrinsic susceptibility at 300 K is 1.42 × 10 –3 emu/mol Oe, which is comparable to that of paramagnetic YCo 3 B 2 and CeCo 3 B 2 with a similar structure and composition. Here, this study showcases the efficacy of combining several methodologies to discover new solids in unexplored phase spaces. This approach includes in situ PXRD data to monitor reactions of precursors upon heating, a diffusion-enhanced synthesis method, and DFT assessment of compound stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strength, deformation, and the fcc–hcp phase transition in condensed Kr and Xe to the 100 GPa pressure range

The rare gas solids exhibit systematic differences in crystal structure, phase transition conditions, bond strength, and other physical properties. The physical properties of heavy rare gas solids krypton and xenon are modified by the martensitic phase transition from face-centered cubic to hexagonal close packed structure over a broad pressure range. Crystal structure, strength, and plastic deformation of krypton and xenon have been investigated at 300 K using compression in the diamond-anvil cell with synchrotron angle-dispersive x-ray diffraction and complementary ruby fluorescence spectroscopy for Xe. Stacking faults indicative of the fcc–hcp phase transition are observed at pressures at and above 1.23 ± 0.05 and 1.9 ± 0.6 GPa in Kr and Xe, respectively. The transition remains incomplete in both solids to pressures greater than 100 GPa. Strength determined from stress measurements in Pt and ruby standards at pressures up to 111 GPa and complemented by observations of strain and texture measurements obtained by x-ray diffraction in the radial geometry to 100 GPa indicates similar or higher strength than Ar at all conditions, with significant stiffening at 15–20 GPa. Radial diffraction data reveal the persistence of broad highly textured fcc diffraction lines to 101 GPa in Xe, suggesting that the axial measurements may underestimate the metastable persistence of the fcc phase due to biased sampling of hcp crystallites resulting from preferred crystallite orientation. Kr and Xe are compared with He, Ne, and Ar for a systematic understanding of physical properties and phase equilibria of rare gas solids.

Compressive stress↗

Mechanism of the wurtzite to rocksalt phase transformation in cadmium sulfide single crystals shock compressed along the 𝑐-axis to elastic impact stresses of ∼ 5 GPa

Cadmium sulfide (CdS), which exhibits a wurzite (WZ) to rocksalt (RS) phase transformation at elevated stresses, is an ideal system to address the role of deformation on phase transformation mechanisms and kinetics. CdS has been shown to have very different elastic-inelastic behavior for shock propagation along the WZ 𝑐- and 𝑎-axes, and also exhibits significant differences in the time scale for the phase transformation when shocked along these different axes. As an important first step in examining the role of deformation in shock-induced phase transformations, here we present in situ, time-resolved x-ray diffraction (XRD) measurements in single-event, shock wave experiments on CdS single crystals shocked along the WZ 𝑐-axis to elastic impact stresses near or above ∼ 5 GPa, where a marked increase in the kinetics of this transformation has been reported. The XRD measurements are compared with forward diffraction simulations to evaluate different proposed phase transformation mechanisms and are shown to be consistent with a shearing mechanism that results in the RS [001] direction being aligned with the original WZ 𝑐-axis and the RS [110] direction being aligned with the original WZ 𝑎-axis. In order to reproduce all observed RS diffraction spots the forward diffraction simulations required three different RS crystalline domains, each with a [110] direction aligned with one of the three original WZ 𝑎-axes, and a significant mosaicity, particularly about the RS [001] direction (the direction of shock propagation). In conclusion, this large mosaicity is likely due to variations in the possible shearing mechanisms that connect the WZ and RS structures, which can create crystallites with up to ∼ ±10° of relative rotations about the RS [001] direction, as well as further rotation of these crystallites as they grow, merge, and coalesce.

Crystal structure↗

In situ characterization of metastable Pb3O5 and Pb2O3 phases during thermal decomposition of PbO2 to PbO

Nonstoichiometric lead oxides play a key role in the formation and cycling of the positive electrodes in a lead acid battery. These phases have been linked to the underutilization of the positive active material but also play a key role in the battery’s cycle life, providing inter-particle adhesion and the connection to the underlying lead grid. Similar phases have previously been identified by mass loss or color change during thermal annealing of PbO2 to PbO, suggesting that at least two intermediate PbOx phases exist. Using multiple in situ analysis techniques (powder diffraction, x-ray absorption, x-ray photoelectron spectroscopy) and ex situ nuclear magnetic resonance measurements, the structural conversion and changes in the lead oxidation states were identified during this process. Isolation of the PbOx phases enabled confirmation of Pb3O5 and Pb2O3 by diffraction and the first 207Pb NMR measurement of these intermediates.

Kinnibrugh, Tiffany L.↗

Nitrate-To-Ammonia Electroconversion at Neutral pH on Polycrystalline Vanadium Sulfide Derived from Vanadium Disulfide

The electrochemical nitrate reduction reaction (NO3RR) offers a pathway to produce NH3 for fuel and fertilizer from waste NO3-. In this work, a polycrystalline vanadium sulfide (VSx), which is derived from solvothermally grown and annealed VS2, is shown to exhibit excellent NO3RR activity (2.3 +- 0.6 mg.cm-2 geo..h-1 @ -0.92 VRHE) and Faradaic efficiency to NH4+ (69 +- 6% at -0.69 VRHE) in buffered neutral pH electrolyte containing 0.1 M NO3-. A variety of characterization techniques are leveraged to support the VSx assignment, including X-ray photoelectron spectroscopy, near-edge X-ray absorption fine structure spectroscopy, selected area electron diffraction, and X-ray diffraction measurements. The VS2 annealing step reduces the oxide character and generates VSx, which, based on the improved NO3RR activity, results in the creation of active sites for NO3- binding. To help shed light on NO3RR on VSx, VS2 is used as a model system, and a grand-canonical density functional theory (GC-DFT) investigation of VS2 shows strong evidence that S vacancies are active sites for NO3RR, where NO3- outcompetes H+ for adsorption at the S-vacancy sites. Moreover, GC-DFT results highlight a thermodynamically favorable reaction to generate NH4+ in an aqueous electrolyte at relevant cathodic potentials. As an annealed material, VSx may contain undersaturated V sites, which show an electronic structure similar to the theoretically calculated S-vacancy site of VS2, and these sites may contribute to the observed increase in NO3RR activity and selectivity for NH4+ on VSx versus unannealed VS2. Finally, kinetic isotope effect measurements suggest that the kinetic rate-limiting step of the NO3RR on VSx is not proton-coupled, indicating it may be the first electron transfer to adsorbed NO3*.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Multidimensional images and aberrations in STEM

Recent advances in scanning transmission electron microscopy (STEM) have led to increased development of multi-dimensional STEM imaging modalities and novel image reconstruction methods. This interest arises because the main electron lens in a modern transmission electron microscope usually has a diffraction-space information limit that is significantly better than the real-space resolution of the same lens. This state-of-affairs is sometimes shared by other scattering methods in modern physics and contributes to a broader excitement surrounding multidimensional techniques that scan a probe while recording diffraction-space images, such as ptychography and scanning nano-beam diffraction. However, the contrasting resolution in the two spaces raises the question as to what is limiting their effective performance. Here, we examine this paradox by considering the effects of aberrations in both image and diffraction planes, and likewise separate the contributions of pre- and post-sample aberrations. In conclusion, this consideration provides insight into aberration-measurement techniques and might also indicate improvements for super-resolution techniques.

Hoglund, Eric R.↗

Unsupervised Segmentation and Clustering Workflow for Efficient Processing of 4D-STEM and 5D-STEM Data

Four-dimensional scanning transmission electron microscopy (4D-STEM) enables mapping of diffraction information with nanometer-scale spatial resolution, offering detailed insight into local structure, orientation, and strain. However, as data dimensionality and sampling density increase, particularly for in situ scanning diffraction experiments (5D-STEM), robust segmentation of structurally consistent behavior across sequential measurements becomes essential for efficient and physically meaningful analysis. Here, we introduce a clustering framework that identifies crystallographically distinct domains from 4D-STEM datasets. By using local diffraction-pattern similarity as a metric, the method extracts closed contours delineating spatially contiguous regions. This approach produces cluster-averaged diffraction patterns that improve signal quality while reducing data volume by orders of magnitude, enabling rapid and accurate orientation, phase, and strain mapping. We demonstrate the applicability of this approach to in situ liquid-cell 4D-STEM data of gold nanoparticle growth. Our method provides a scalable and generalizable route for spatially coherent segmentation, data compression, and quantitative structure–strain mapping across diverse 4D-STEM modalities. The full analysis code and example workflows are publicly available to support reproducibility and reuse.

4D-STEM↗