Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Systems and methods for regulating a microgrid

A microgrid system includes one or more power generators configured to provide electrical energy. The microgrid system also includes a localized distribution network coupled to the one or more power generators, coupled to the one or more loads, and coupled to an external grid. The microgrid system further includes a microgrid controller configured to predict microgrid demand for the one or more loads for a predetermined period of time. The microgrid controller is also configured to receive demand information for the external grid for the predetermined period of time. The microgrid controller is further configured to determine an operation plan for the one or more power generators based on the predicted microgrid demand and the received demand information. Moreover, the microgrid controller is configured to determine a schedule to transmit electrical energy to the external grid based on the operation plan.

Baone, Chaitanya Ashok↗

On a Future for Smart Inverters with Integrated System Functions

The modern electric power grid is gradually evolving to include high penetration power electronics in a distributed architecture which will pose pressing new challenges on power quality, system control, and operation. The state-of-the-art smart inverters for solar photovoltaics may not be sufficient to address some of the stability and control challenges such as harmonic resonances due to the interactions of multiple power electronics converters. This paper discusses a future of smart inverters with integrated system functions and its associated challenges, and identifies smart inverter research trends and features in the context of flexible control architectures. Future power electronics research will shift from hardware solutions to more control solutions with integrated system functions under distributed power grid scenarios with small-scale power electronics interfaced with distributed generations and loads.

Xue, Yaosuo↗

Synthetic Ancillary Service Generator (SynAS) v1

The balance of demand and supply in the electric power grid is a crucial element to grid reliability. While balancing is typically provided by conventional power plants, with spinning generators, distributed energy resources (DER) and especially electric vehicles (EVs) pose a great potential to provide such service. This project conducted a field demonstration at the Los Angeles Air Force Base (LA-AFB) where a fleet of mixed-use bi-directional EVs were actively participating in the California Independent System Operator (CAISO) market for frequency regulation. While participation in regulation markets is promising, a major drawback in designing control systems and assessing potential revenue is the lack of example frequency regulation signals. This project introduces an open-source dataset for 143 days of four-second regulation data, and the SynAS Python module to synthetically generate frequency regulation signals of arbitrary length.

Black, DouglasR↗

Storm DEPART(Damage Estimate Prediction And Recovery Tool)

Damage prediction, materials needed, and resource allocation modeling capability in order to support pre-incident planning and preparation by predicting damage to the power generation capacity, transmission grids, distribution networks, and communications assets. The capabilities will be developed by multiple factors to include wind bands, storm surge, and flooding forecasts to participant’s assets which will result in a report of predicted damages. Additional factors to include available participants infrastructure data to include class, age, construction, location, wind rating, and additional information not in the public domain. Based on predicted damages, the output will be a bill of materials (BOM) to support short-term recovery operations. The extensiveness and level of detail for this BOM will depend on the replacement configuration specifications provided for each individual participant asset. Any limiting factors for the model will be applied related supply chain and resource constraints.

Klett, Mary↗

ARPA-E Impacts: A Sampling of Project Outcomes, Volume II

The Advanced Research Projects Agency-Energy (ARPA-E) is demonstrating that a collaborative model has the power to deliver real value. The Agency’s first compilation booklet of impact sheets, published in 2016, began to tell the story of how ARPA-E has already made an impact in just seven years—funding a diverse and sophisticated research portfolio on advanced energy technologies that enable the United States to tackle our most pressing energy challenges. One year later our research investments continue to pay off, with a number of current and alumni project teams successfully commercializing their technologies and advancing the state of the art in transformative areas of energy science and engineering. There is no single measure that can fully illustrate ARPA-E’s success to date, but several statistics viewed collectively begin to reveal the Agency’s impact. Since 2009, ARPA-E has provided more than $1.5 billion in funding for 36 focused programs and three open funding solicitations, totaling over 580 projects. Of those, 263 are now alumni projects. Many teams have successfully leveraged ARPA-E’s investment: 56 have formed new companies, 68 have partnered with other government agencies to continue their technology development, and 74 teams have together raised more than $1.8 billion in reported funding from the private sector to bring their technologies to market. However, even when viewed together, those measures do not capture ARPA-E’s full impact. To best understand the Agency’s success, the specific scientific and engineering challenges that ARPA-E project teams have overcome must be understood. This booklet provides concrete examples of those successes, ranging from innovations that will bear fruit in the future to ones that are beginning to penetrate the market as products today. Importantly, half of the projects highlighted in this volume stem from OPEN solicitations, which the agency has run in 2009, 2012, and 2015. ARPA-E’s OPEN programs are an extraordinary opportunity for the R&D community to challenge ARPA-E in areas of technology not covered by the agency’s focused technology programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Survey of aircraft electrical power systems

Areas investigated include: (1) load analysis; (2) power distribution, conversion techniques and generation; (3) design criteria and performance capabilities of hydraulic and pneumatic systems; (4) system control and protection methods; (5) component and heat transfer systems cooling; and (6) electrical system reliability.

Lee, C. H.↗

Overview of environmental test plans for Space Station Freedom work package 4

The generation and distribution of electric power for Space Station Freedom (SSF) is critical to the station's success. Work Package 4 (WP-04) has the responsibility for the design, development, test, and delivery of the Electric Power System (EPS) for the SSF. During launch, assembly, and operation, the EPS will be subjected to various environments. A test and verification approach has been developed to assure that the EPS will function in these environments. An overview of that test program is presented with emphasis on environmental testing of hardware. Two key areas of the test program are highlighted in the overview. One area is the verification of the Solar Power Module (SPM) and associated cargo element hardware. This area includes detailing the plans for development and qualification testing of the SPM hardware. One series of tests, including modal and acoustic, has been completed on a development cargo element. Another area highlighted is the acceptance testing of high-power Orbital Replacement Units (ORU). The environmental test equipment plans are presented and reviewed in light of an aggressive production rate, which delivers ORU's to the WP-04 and other Space Station Work Packages. Through implementing the test program as outlined, the EPS hardware will be certified for flight and operation on the Space Station Freedom.

Peterson, Tom J.↗

Space Solar Power Technical Interchange Meeting 2: SSP TIM 2

The 2nd Space Solar Power Technical Interchange Meeting (SSP TIM 2) was conducted September 21st through 24th with the first part consisting of a Plenary session. The summary results of this Plenary session are contained in part one of this report. The attendees were then organized into Working Breakout Sessions and Integrated Product Team (IPT) Sessions for the purpose of conducting in-depth discussions in specific topic areas and developing a consensus as to appropriate study plans and actions to be taken. The Second part covers the Plenary Summary Session, which contains the summary results of the Working Breakout Sessions and IPT Sessions. The appendix contains the list of attendees. The ob'jective was to provide an update for the study teams and develop plans for subsequent study activities. This SSP TIM 2 was initiated and the results reported electronically over the Internet. The International Space Station (ISS) could provide the following opportunities for conducting research and technology (R&T) which are applicable to SSP: (1) Automation and Robotics, (2) Advanced Power Generation, (3) Advanced Power Management & Distribution (PMAD), (4) Communications Systems and Networks, (5) Energy Storage, (6) In Space Propulsion (ISP), (7) Structural Dynamics and Control, and Assembly and (8) Wireless Power Transmission.

Sanders, Jim↗

Space Solar Power Demonstrations: Challenges and Progress

The prospects of using electrical power beamed from space are coming closer to reality with the continued pursuit and improvements in the supporting space solar research and technology. Space Solar Power (SSP) has been explored off and on for approximately three decades as a viable alternative and clean energy source. Results produced through the more recent Space Solar Power Exploratory Research and Technology (SERT) program involving extensive participation by industry, universities, and government has provided a sound technical basis for believing that technology can be improved to the extent that SSP systems can be built, economically feasible, and successfully deployed in space. Considerable advancements have been made in conceptual designs and supporting technologies including solar power generation, wireless power transmission, power management distribution, thermal management and materials, and the integrated systems engineering assessments. Basic technologies have progressed to the point were the next logical step is to formulate and conduct sophisticated demonstrations involving prototype hardware as final proof of concepts and identify high end technology readiness levels in preparation for full scale SSP systems designs. In addition to continued technical development issues, environmental and safety issues must be addressed and appropriate actions taken to reassure the public and prepare them for the future use of this alternative renewable energy resource. Accomplishing these objectives will allow informed future decisions regarding further SSP and related R&D investments by both NASA management and prospective external partners. In particular, accomplishing these objectives will also guide further definition of SSP and related technology roadmaps including performance objectives, resources and schedules; including 'multi-purpose' applications (terrestrial markets, science, commercial development of space, and other government missions).

Howell, Joe T.↗

Understanding and Controlling Hybrid Electric Gas Turbine Engine Transient Dynamics

The electrification of the gas turbine engine is known to increase the flexibility of aircraft architectures by enabling the generation of electrical power to distribute to other electrically based, thrust producing subsystems. It also has potential for direct performance benefits in the gas turbine engine itself, both at steady state and dynamically. Although the design focus of the gas turbine engine performance is primarily at steady state, it is often the instabilities occurring during transients that cause disequilibrium and constrain performance improvements. Instabilities arise due to the disequilibrium of the energy storage mechanisms within the traditional engine system and likewise for the electrified engine system. The primary energy storage mechanisms in the traditional system are the rotational inertia, gas path volumes, the thermal masses that make up the mechanical structure, and now, the electrical power system will provide additional contributions. Understanding the effect each of these energy storage mechanisms has on the others and controlling them appropriately allows for the suppression of state changes within the turbomachinery components to the degree that the components remain near steady state, thus reducing the disequilibrium within the system. The ability to tightly regulate the state changes of turbomachinery components, such as the compressor, minimizes the excursion of the compressor operating point from the operating line (operability), allowing for higher performing, more efficient compressor designs by decreasing the amount of stall margin needed for safe engine power level changes. Preliminary studies with the electrification of the turbine engine have shown that this is possible, and this concept can lead to design trades benefitting engine performance, weight, and volume. This paper explores in detail the energy storage mechanisms and control approaches for coordinating their state changes, and ultimately proposes that a higher performing, more efficient compressor design can result.

transient dynamics↗

Low reflectance high power RF load

A load for traveling microwave energy has an absorptive volume defined by cylindrical body enclosed by a first end cap and a second end cap. The first end cap has an aperture for the passage of an input waveguide with a rotating part that is coupled to a reflective mirror. The inner surfaces of the absorptive volume consist of a resistive material or are coated with a coating which absorbs a fraction of incident RF energy, and the remainder of the RF energy reflects. The angle of the reflector and end caps is selected such that reflected RF energy dissipates an increasing percentage of the remaining RF energy at each reflection, and the reflected RF energy which returns to the rotating mirror is directed to the back surface of the rotating reflector, and is not coupled to the input waveguide. Additionally, the reflector may have a surface which generates a more uniform power distribution function axially and laterally, to increase the power handling capability of the RF load. The input waveguide may be corrugated for HE11 mode input energy.

43 PARTICLE ACCELERATORS↗

Subharmonic power line carrier based island detection systems and methods

Systems and methods for identifying an island condition in a power distribution system and disconnecting distributed generators in the case of islanding. The systems and methods are used to enable reliable detection of island formation with high false-trip immunity, for any combination of distributed energy resources, and for distributed energy resources using grid support functions.

Ropp, Michael↗

Power Grid Contingency Analysis with Machine Learning: A Brief Survey and Prospects

We briefly review previous applications of machine learning (ML) in power grid analyses and introduce our ongoing effort toward developing a generative-adversarial (GA) model for fast and reliable grid contingency analyses. According to our review, the persisting limitation of traditional ML techniques in grid analyses is the need for an exhaustive amount of training data for model generalization and accurate predictions. GA models overcome this limitation by first learning true data distribution from a small training set, from which new samples assimilating true data are generated with some variations. Subsequently, GA models can transfer learn or super-generalize with increased accuracy, that is, accurately predict n - (k + 2) contingencies from a small n - k training set and generated n - (k + 1) data. The joint effort between Idaho National Lab and Florida State University strives to develop a zero-shot and deep learning-based contingency analysis tool, named Smart Contingency Analysis Neural Network (SCANN), by leveraging the aforementioned advantages of GA models. The basic architecture of SCANN stems from the Latent Encoding of Atypical Perturbations network combined with an adversarial network, and it is designed to generate imbalanced power flow data from learned true data distributions for prediction purposes. Here we also introduce the abstract concept of resilience-chaos plots, a new resilience characterization tool proposed to complement SCANN by aiding in the assessment of large amounts of high-order contingency predictions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

Robust Decentralized State Estimation

The health of a distribution grid is maintained by a distribution management system (DMS). Before the rise of distributed energy resource (DER), the DMS primarily managed the unidirectional power flow through the distribution grid from external sources (e.g. power brought from a large generating plant to the distribution grid by a transmission grid). Now, a typical DMS will utilize distributed energy resource manage systems (DERMS) to account for DER such as rooftop solar, community solar, and wind turbines. Each DERMS is responsible for an area of the distribution grid, issuing commands to the associated real-time automation controller (RTAC) to regulate power flow and maintain health of that section of the grid.

42 ENGINEERING↗

Protection schemes used in North American microgrids

This study reviewed existing conventional and nonconventional protection schemes for grid-connected and islanded mode operations in North American microgrid projects. The microgrid projects investigated in this study used different types of distributed energy resources (DERs) and integrated hydropower/diesel generators, gas/steam/wind turbines, and photovoltaic systems with energy storage. In this work, conventional protection schemes were defined as those within the IEEE Standard C37.2-2008, whereas nonconventional schemes were those not defined within this standard. The pros and cons of conventional and nonconventional protection schemes were discussed in detail. The overvoltage, undervoltage, and frequency elements were the most common conventional protection schemes applied in microgrid projects in North America. These protection elements were used to detect the islanded conditions and faults that could not be sensed by overcurrent relays because of small fault currents contributed by low-inertia DERs and power-electronic sources. Directional overcurrent elements were used to distinguish between external (grid) and internal (microgrid) faults. Adaptive protection was the most popular nonconventional protection scheme applied to the microgrid projects. In conclusion, different types of DERs and operational modes must be considered in order to address the protection and control challenges of each microgrid and to obtain the best technical and economical solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗