Anisotropic multiband superconductivity in 2 M − WS 2 probed by controlled disorder

The intrinsically superconducting Dirac semimetal 2 M − WS 2 is a promising candidate for realizing proximity-induced topological superconductivity in its protected surface states. A precise characterization of the bulk superconducting state is essential to understand the nature of surface superconductivity in the system. Here, we report a detailed experimental study of the temperature-dependent London penetration depth, λ ( T ) , the upper critical field, H c 2 ( T ) , and the effects of nonmagnetic disorder on these quantities, as well as on the superconducting transition temperature T c in single crystals of 2 M − WS 2 . We observe a power-law variation of λ ( T ) ∝ T 3 at temperatures below 0.35 T c . Nonmagnetic pointlike disorder induced by 2.5 MeV electron irradiation at various doses results in a significant suppression of T c . These observations are markedly different from expectations for a fully gapped isotropic s − wave superconductor. Together with the substantial increase of slope, d H c 2 / d T | T = T c , with increasing disorder, our results suggest a strongly anisotropic s + + multiband superconducting state. These results have direct consequences for the expected proximity-induced superconductivity of the topological surface states. Published by the American Physical Society 2024

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Bridging microscale to macroscale mechanical property measurements and predication of performance limitation for FeCrAl alloys under extreme reactor applications

Microscale mechanical testing has greatly benefited nuclear materials studies in at least two aspects: one is its feasibility to integrate with SEM and TEM microscopes for in situ atomic scale or microscale structural characterization to reveal fundamental details, and the other is its significance in development of accelerator-based ion irradiation technique as a surrogate method to simulate neutron damage. Ion irradiation is able to reach damage creation at a level at least three orders of magnitudes higher than test reactors. However, limited ion penetration depths, which are about a few microns for MeVs heavy ions and 10s microns for MeV light ions, make microscale mechanical tests a necessity. But, there is a great challenge to bridge microscale tests to macroscale tests because a bulk specimen of irradiated nuclear materials for high dose applications cannot be obtained in laboratory.

36 MATERIALS SCIENCE↗

Mechanisms of QT prolongation by buprenorphine cannot be explained by direct hERG channel block

Buprenorphine is a μ-opioid receptor (MOR) partial agonist used to manage pain and addiction. QT C prolongation that crosses the 10 msec threshold of regulatory concern was observed at a supratherapeutic dose in two thorough QT studies for the transdermal buprenorphine product BUTRANS®. Because QT C prolongation can be associated with Torsades de Pointes (TdP), a rare but potentially fatal ventricular arrhythmia, these results have led to further investigation of the electrophysiological effects of buprenorphine. Drug-induced QT C prolongation and TdP are most commonly caused by acute inhibition of hERG current (I hERG ) that contribute to the repolarizing phase of the ventricular action potentials (APs). Concomitant inhibition of inward late Na + (I NaL ) and/or L-type Ca 2+ (I CaL ) current can offer some protection against proarrhythmia. Therefore, we characterized the effects of buprenorphine and its major metabolite norbuprenorphine on cardiac hERG, Ca 2+ , and Na + ion channels, as well as cardiac APs. For comparison, methadone, a MOR agonist associated with QT C prolongation and high TdP risk, and naltrexone and naloxone, two opioid receptor antagonists, were also studied. Whole cell recordings were performed at 37°C on cells stably expressing hERG, Ca V 1.2, and Na V 1.5 proteins. Microelectrode array (MEA) recordings were made on human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs). The results showed that buprenorphine, norbuprenorphine, naltrexone, and naloxone had no effect on I hERG , I CaL , I NaL , and peak Na + current (I NaP ) at clinically relevant concentrations. In contrast, methadone inhibited I hERG , I CaL , and I NaL . Experiments on iPSC-CMs showed a lack of effect for buprenorphine, norbuprenorphine, naltrexone, and naloxone, and delayed repolarization for methadone at clinically relevant concentrations. The mechanism of QT C prolongation is opioid moiety-specific. This remains undefined for buprenorphine, while for methadone it involves direct hERG channel block. There is no evidence that buprenorphine use is associated with TdP. Whether this lack of TdP risk can be generalized to other drugs with QT C prolongation not mediated by acute hERG channel block warrants further study.

59 BASIC BIOLOGICAL SCIENCES↗

Summer 2021 Co-op Report: X-Ray Scintillation Detector (A Co-op Work Experience Report)

The M-3 team was in need of a detector that could be used properly characterize their X-Ray machines. It can also be used to diagnose the X-ray in the case that problems arise before or during an experiment. They put me in charge of designing, ordering, and constructing said detector. After doing research, I found that scintillation-based detectors would be the best diagnostic tool for this purpose. It will allow the team to collect a full photon count of the X-ray pulse as well as provide spectroscopy functions with which we can view photon counts at different energy levels. This will also allow them to calculate an accurate dose given from the machine. Due to lead times, the crystals are still in manufacturing, thus the detector could not be completed. Although the designs and calculations needed to construct and operate the scintillator have been completed which is what I will be presenting in this document. Compared to the detectors being used before, my design offers a cheaper and far more efficient alternative.

42 ENGINEERING↗

Irradiation creep model for α-Fe: Dislocation climb in the presence of stress fields (Final Report)

Irradiation creep is known to be an important process for structural materials in nuclear environments, potentially leading to creep failure at temperatures where thermal creep is generally negligible. While there is a great deal of data for irradiation creep in steels and zirconium alloys in light water reactor conditions, much less is known for first wall materials under fusion energy conditions. Lacking suitable fusion neutron sources for detailed experimentation, modeling, and simulation can help bridge the dose-rate and spectral-effects gap and produce quantifiable expectations for creep deformation of first wall materials under standard fusion conditions. In this work, we present a comprehensive model for irradiation creep created from merging a crystal plasticity representation of the dislocation microstructure and a defect evolution simulator that accounts for the entire cluster dimensionality space. Both approaches are linked by way of a climb velocity that captures dislocation-biased defect absorption and a dislocation strengthening term that reflects the accumulation of defect clusters in the system. We carry out our study in Fe under first wall fusion reactor conditions, characterized by a fusion neutron spectrum at temperatures between 300 and 800°K.

36 MATERIALS SCIENCE↗

Performance evaluation of pulse shape discrimination capable organic scintillators for space applications

Scintillators with pulse-shape discrimination (PSD) capability are of great interest to many fields in the scientific community. The ability to discern a gamma ray from a neutron using PSD varies between different types of scintillator materials and dopants. Here a new generation of organic scintillator materials with PSD capability were studied to determine their radiation hardness to neutron and gamma-ray radiation. The PSD capability, average pulse shapes, and light output of four types of organic scintillator were characterized before and after neutron and gamma-ray irradiation. The main goal of this investigation is to study the effects of long-term irradiation that may be experienced in space applications on the light output and particle discriminating capabilities of each material. EJ-270, EJ-276, organic glass, and Stilbene were tested. Damage due to neutron irradiation (displacement damage) was not observed in any of the scintillators up to 2.56 x 10 11 n/cm 2 , except for Stilbene which showed a small (12%) decrease in light output. All scintillators presented some light output reduction after gamma-ray irradiation (total ionizing dose), with reductions of 17% (EJ-276 and OGS), 32% (EJ-270), and 42% (Stilbene) observed immediately after 100 kRad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Seaweed-derived fucoidans and rhamnan sulfates serve as potent anti-SARS-CoV-2 agents with potential for prophylaxis

Seaweeds represent a rich source of sulfated polysaccharides with similarity to heparan sulfate, a facilitator of myriad virus host cell attachment. For this reason, attention has been drawn to their antiviral activity, including the potential for anti-SARS-CoV-2 activity. We have identified and structurally characterized several fucoidan extracts, including those from different species of brown macroalga, and a rhamnan sulfate from a green macroalga species. A high molecular weight fucoidan extracted from Saccharina japonica (FSjRPI-27), and a rhamnan sulfate extracted from Monostroma nitidum (RSMn), showed potent competitive inhibition of spike glycoprotein receptor binding to a heparin-coated SPR chip. This inhibition was also observed in cell-based assays using hACE2 HEK-293 T cells infected by pseudotyped SARS-CoV-2 virus with IC50 values <1 μg/mL. Effectiveness was demonstrated in vivo using hACE2–transgenic mice. Intranasal administration of FSjRPI-27 showed protection when dosed 6 h prior to and at infection, and then every 2 days post-infection, with 100 % survival and no toxicity at 104 plaque-forming units per mouse vs. buffer control. At 5-fold higher virus dose, FSjRPI-27 reduced mortality and yielded reduced viral titers in bronchioalveolar fluid and lung homogenates vs. buffer control. Furthermore, these findings suggest the potential application of seaweed-based sulfated polysaccharides as promising anti-SARS-CoV-2 prophylactics.

60 APPLIED LIFE SCIENCES↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

Post-Irradiation Fracture Toughness Characterization of Generation II FeCrAl Alloys

FeCrAl alloys are promising candidate materials for the accident tolerant fuel (ATF) cladding application due to their exceptional resistance to oxidation in elevated temperature steam environments. Currently, limited fracture toughness data are available for the FeCrAl alloys, including the FeCrAl alloys newly developed at Oak Ridge National Laboratory (ORNL) under the U.S. Department of Energy’s Advanced Fuels Campaign (AFC) program. In this study, two Generation II candidate FeCrAl alloys, i.e., C06M (81.8Fe-10Cr-6Al-0.03Y-2Mo-0.2Si) and C36M (78.8Fe-13Cr-6Al-0.03Y-2Mo-0.2Si), were irradiated in the High Flux Isotope Reactor (HFIR) at ORNL to assess the fracture characteristics of these alloys after neutron irradiation. A total of six rabbit capsules were irradiated in HFIR at target temperatures of 200°C, 330°C, and 500°C up to target damage doses of 8 displacements per atom (dpa) and 16 dpa. Post-irradiation fracture toughness testing was performed following the Master Curve method in the ASTM E1921 standard. The main findings of this study are:1) Both the C06M and C36M alloys exhibited a similar response to irradiation concerning irradiation hardening and embrittlement.2) The irradiation temperature played different roles in terms of irradiation hardening and embrittlement for both C06M and C36M: after irradiation between 166°C and 204°C, both materials exhibited significant irradiation hardening and embrittlement; after irradiation between 315°C and 343°C, both materials showed small irradiation hardening without irradiation embrittlement. After irradiation between 501°C and 507°C, however, the irradiation softening without irradiation embrittlement was observed in both materials.3) Comparing the microhardness and Master Curve reference temperature T0q before and after neutron irradiation, we did not observe a linear correlation between the two parameters for both C06M and C36M steels. This should be mainly due to a flat response of the Master Curve reference temperature T0q to the irradiations at 166–204°C and 315–343°C ranges4) C06M showed a lower T0q, meaning better toughness, than C36M at the unirradiated condition, and such trend was kept even after neutron irradiation except for the 166–204°C irradiation after which both materials had similar T0q.5) In terms of hardening and embrittlement, the irradiation effect on both C06M and C36M appeared to saturate after an irradiation dose of 7 dpa.

Chen, Xiang↗

Microstructural evolution in doped high entropy alloys NiCoFeCr-3X (X=Pd/Al/Cu) under irradiation

Commonly studied equatomic single-phase FCC high entropy alloys based on 3d transition metals like NiCoFeCr do not provide adequate strength and radiation resistance at high doses for nuclear structural applications. In the current study, the major alloying effects like lattice distortion, ordering and clustering tendencies were investigated by adding low concentration of Pd, Al, or Cu respectively to study the doping effects on the ion irradiation response of NiCoFeCr alloy. The alloys were irradiated with 3 MeV Ni 2+ ions at 500 °C to a fluence of 1 × 10 17 /cm 2 at a beam flux of approximately 2.8 × 10 12 ions/cm 2 /s. The microstructural evolution upon irradiation i.e., formation of dislocation networks, radiation induced segregation and precipitation, and void formation were studied in detail. Further, post-irradiation characterization results showed that a Pd addition leads to a high void nucleation rate but controlled void growth, which may be attributed to increased lattice distortion. In Al added HEA, our microstructural analysis indicates that radiation induced ordered L1 2 precipitates do not affect void swelling significantly. Cu addition led to Cu precipitation that drastically suppressed dislocation density and void swelling of the alloy. Additionally, a model was developed to qualitatively describe the trend in void swelling of typical FCC alloys under ion irradiation. This model was able to qualitatively explain the suppression and reappearance of void swelling in ion irradiated alloys that generally occurs near the region with peak implanted ion concentration.

36 MATERIALS SCIENCE↗

Electrochemical Detection of Oxycodone and Its Main Metabolites with Nafion-Coated Single-Walled Carbon Nanotube Electrodes

Oxycodone is a strong opioid frequently used as an analgesic. Although proven efficacious in the management of moderate to severe acute pain and cancer pain, use of oxycodone imposes a risk of adverse effects such as addiction, overdose, and death. Fast and accurate determination of oxycodone blood concentration would enable personalized dosing and monitoring of the analgesic as well as quick diagnostics of possible overdose in emergency care. However, in addition to the parent drug, several metabolites are always present in the blood after a dose of oxycodone, and to date, there is no electrochemical data available on any of these metabolites. In this paper, a single-walled carbon nanotube (SWCNT) electrode and a Nafion-coated SWCNT electrode were used, for the first time, to study the electrochemical behavior of oxycodone and its two main metabolites, noroxycodone and oxymorphone. Both electrode types could selectively detect oxycodone in the presence of noroxycodone and oxymorphone. However, we have previously shown that addition of a Nafion coating on top of the SWCNT electrode is essential for direct measurements in complex biological matrices. Therefore, in this work, the Nafion/SWCNT electrode was further characterized and used for measuring clinically relevant concentrations of oxycodone in buffer solution. The limit of detection for oxycodone with the Nafion/SWCNT sensor was 85 nM, and the linear range was 0.5–10 μM in buffer solution. Furthermore, this study shows that the fabricated Nafion/SWCNT sensor has potential to be applied in clinical concentration measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intrinsic Li Distribution in Layered Transition-Metal Oxides Using Low-Dose Scanning Transmission Electron Microscopy and Spectroscopy

Understanding Li distribution in layered lithium transition-metal oxide (LiTMO) cathodes in Li-ion batteries has been a major challenge at the atomic scale and nanoscale. Li is extremely difficult to study by transmission electron microscopy (TEM) because the high-energy electrons impart significant energy and cause massive migration. Here, we directly map the intrinsic spatial distribution and bonding of Li in LiNiO 2 -layered cathode materials using low-dose and low-loss electron energy loss spectroscopy (EELS). EELS spectra of the Li–K edge are measured simultaneously with O–K and Ni–L, M 3,2 edges from layered, cation-mixed, and rock-salt phases and directly matched with atomic-resolution scanning TEM images to correlate the changes in peak intensities and positions to the stoichiometry changes with continual loss of Li and O. Changes in the Li content in the LiNiO 2 particles as a function of electron beam dose are studied by sequential Li spectroscopic mapping. We show that the “intrinsic” Li distribution can be observed using a total dose of less than ~1.5 × 10 8 e – nm –2 at an accelerating voltage of 80 kV. The method of nanoscale mapping of Li distribution introduced in this study is applicable to high-Ni LiTMO cathode materials (>89% of Ni) as well as LiNiO 2 . Further study on the extra peaks of the Li–K edge reveals that the peak at ~59 eV is from the Li ions intercalated in between NiO 2 layers barely interacting with each other with less Li K shell electrons pulled to the L shell electrons in NiO 2 . Furthermore, the results shown here provide improved low-loss TEM characterization approaches that can be used to understand the intrinsic fundamental behaviors in Li-ion batteries.

25 ENERGY STORAGE↗

THF co-solvent pretreatment prevents lignin redeposition from interfering with enzymes yielding prolonged cellulase activity

Background: Conventional aqueous dilute sulfuric acid (DSA) pretreatment of lignocellulosic biomass facilitates hemicellulose solubilization and can improve subsequent enzymatic digestibility of cellulose to fermentable glucose. However, much of the lignin after DSA pretreatment either remains intact within the cell wall or readily redeposits back onto the biomass surface. This redeposited lignin has been shown to reduce enzyme activity and contribute to rapid enzyme deactivation, thus, necessitating significantly higher enzyme loadings than deemed economical for biofuel production from biomass. Results: In this study, we demonstrate how detrimental lignin redeposition on biomass surface after pretreatment can be prevented by employing Co-solvent Enhanced Lignocellulosic Fractionation (CELF) pretreatment that uses THF–water co-solvents with dilute sulfuric acid to solubilize lignin and overcome limitations of DSA pretreatment. We first find that enzymatic hydrolysis of CELF-pretreated switchgrass can sustain a high enzyme activity over incubation periods as long as 5 weeks with enzyme doses as low as 2 mg protein/g glucan to achieve 90% yield to glucose. A modified Ninhydrin-based protein assay revealed that the free-enzyme concentration in the hydrolysate liquor, related to enzyme activity, remained unchanged over long hydrolysis times. DSA-pretreated switchgrass, by contrast, had a 40% drop in free enzymes in solution during incubation, providing evidence of enzyme deactivation. Furthermore, measurements of enzyme adsorption per gram of lignin suggested that CELF prevented lignin redeposition onto the biomass surface, and the little lignin left in the solids was mostly integral to the original lignin–carbohydrate complex (LCC). Scanning electron micrographs and NMR characterization of lignin supported this observation. Conclusions: Enzymatic hydrolysis of solids from CELF pretreatment of switchgrass at low enzyme loadings was sustained for considerably longer times and reached higher conversions than for DSA solids. Analysis of solids following pretreatment and enzymatic hydrolysis showed that prolonged cellulase activity could be attributed to the limited lignin redeposition on the biomass surface making more enzymes available for hydrolysis of more accessible glucan.

09 BIOMASS FUELS↗

A Chimeric LBT-GFP Biosensor Exhibits Antithetical Fluorescence Responses to Ca 2+ and Dy 3+ Binding

Rare earth elements (REEs) are critical components in emerging technologies, but their mining and refining processes are often laborious, costly, and environmentally damaging. Developing green and efficient separation methods for REEs is crucial. Biomolecular approaches using lanthanide-binding proteins and peptides show promise for selective REE extraction and separation. In this study, we present the design and characterization of a genetically encoded fluorescence indicator (GEFI) construct that combines a superfolder green fluorescent protein (sfGFP) with a dual lanthanide-binding tag (2×dLBT). The 2×dLBT insert induces conformational changes in sfGFP upon lanthanide binding, modulating the fluorescence intensity. The sfGFP-2×dLBT biosensor exhibited distinct fluorescence responses to different lanthanide ions, with the highest dynamic range observed for heavy REEs like dysprosium (Dy 3+ ). Interestingly, the sensor displayed an antithetical response, where low concentrations of lanthanides initially quenched the fluorescence, but higher concentrations led to a significant fluorescence increase (1.5-fold). The Ca 2+ ion on the other hand showed only a dose-dependent quenching of the fluorescence response. Based on these observations, the biphasic response of the biosensor to lanthanides was eliminated by pretreating the sensor with calcium, which further expanded the dynamic range up to 3-fold for Dy 3+ . The lanthanide-selective and concentration-dependent fluorescence changes of the sfGFP-2×dLBT biosensor demonstrate its potential as a platform for developing specific sensors for various REEs. These sensors could enable rapid and cost-effective determination of REE composition in complex mixtures, facilitating the separation and recovery of critical REEs from electronic waste and other REE-containing sources.

59 BASIC BIOLOGICAL SCIENCES↗

STEM Imaging of Materials: Final Report for DE-FG02-08ER46547

This project supported research advancing the state of the art in scanning transmission electron microscopy (STEM) imaging and characterization of materials, especially electronic materials. The project began with studies of point defects in materials using high-resolution Z-contrast STEM, then evolved to including methods in four-dimensional (4D) STEM and machine learning. Highlights include: (1) the discovery of stable, p-type ZnO via Sb doping, (2) demonstration that the high performance of InGaN LEDs is not due to In composition fluctuations as previously proposed, (3) the demonstration of the first sub-pm precision high-resolution STEM images using non-rigid registration of a series of STEM images, (4) the extension of high-precision STEM to low dose imaging and spectrum imaging, (5) discovery of a synthesis method for twisted spiral growth of transition-metal dichalcogenide materials via chemical vapor deposition, and (6) development of machine-learning methods for analysis and denoising of enormous 4D STEM data sets.

36 MATERIALS SCIENCE↗

Microstructural Effects of High Dose Helium Implantation in ErD 2

Metal hydrides can store hydrogen isotopes with high volumetric density. In metal tritides, tritium beta decay can result in accumulation of helium within the solid, in some cases exceeding 10 at.% helium after only 4 years of aging. Helium is insoluble in most materials, but often does not readily escape, and instead coalesces to form nanoscale bubbles when helium concentrations are near 1 at.%. Blistering or spallation often occurs at higher concentrations. Radioactive particles shed during this process present a potential safety hazard. This study investigates the effects of high helium concentrations on erbium deuteride (ErD 2 ), a non-radioactive surrogate material for erbium tritide (ErT 2 ). To simulate tritium decay in the surrogate, high doses of 120 keV helium ions were implanted into ErD 2 films at room temperature. Scanning and transmission electron microscopy indicated spherical helium bubble formation at a critical concentration of 1.5 at.% and bubble linkage leading to nanoscale crack formation at a concentration of 7.5 at.%. Additionally, crack propagation occurred through the nanocrack region, resulting in spallation extending from the implantation peak to the surface. Electron energy loss spectroscopy was utilized to confirm the presence of high-pressure helium in the nanocracks, suggesting that helium gas plays a predominant role in deformation. This work improves the overall understanding of helium behavior in ErD 2 by using modern characterization techniques to determine: the critical helium concentration required for bubble formation, the material failure mechanism at high concentration, and the nanoscale mechanisms responsible for material failure in helium implanted ErD 2 .

36 MATERIALS SCIENCE↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.