Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Receiver Design, Performance Analysis, and Evaluation for Space-Borne Laser Altimeters and Space-to-Space Laser Ranging Systems

This progress report consists of two separate reports. The first one describes our work on the use of variable gain amplifiers to increase the receiver dynamic range of space borne laser altimeters such as NASA's Geoscience Laser Altimeter Systems (GLAS). The requirement of the receiver dynamic range was first calculated. A breadboard variable gain amplifier circuit was made and the performance was fully characterized. The circuit will also be tested in flight on board the Shuttle Laser Altimeter (SLA-02) next year. The second report describes our research on the master clock oscillator frequency calibration for space borne laser altimeter systems using global positioning system (GPS) receivers.

Davidson, Frederic M.↗

3D parallel-detection microwave tomography for clinical breast imaging

A biomedical microwave tomography system with 3D-imaging capabilities has been constructed and translated to the clinic. Updates to the hardware and reconfiguration of the electronic-network layouts in a more compartmentalized construct have streamlined system packaging. Upgrades to the data acquisition and microwave components have increased data-acquisition speeds and improved system performance. By incorporating analog-to-digital boards that accommodate the linear amplification and dynamic-range coverage our system requires, a complete set of data (for a fixed array position at a single frequency) is now acquired in 5.8 s. Replacement of key components (e.g., switches and power dividers) by devices with improved operational bandwidths has enhanced system response over a wider frequency range. High-integrity, low-power signals are routinely measured down to −130 dBm for frequencies ranging from 500 to 2300 MHz. Adequate inter-channel isolation has been maintained, and a dynamic range >110 dB has been achieved for the full operating frequency range (500–2900 MHz). For our primary band of interest, the associated measurement deviations are less than 0.33% and 0.5° for signal amplitude and phase values, respectively. A modified monopole antenna array (composed of two interwoven eight-element sub-arrays), in conjunction with an updated motion-control system capable of independently moving the sub-arrays to various in-plane and cross-plane positions within the illumination chamber, has been configured in the new design for full volumetric data acquisition. Signal-to-noise ratios (SNRs) are more than adequate for all transmit/receive antenna pairs over the full frequency range and for the variety of in-plane and cross-plane configurations. For proximal receivers, in-plane SNRs greater than 80 dB are observed up to 2900 MHz, while cross-plane SNRs greater than 80 dB are seen for 6 cm sub-array spacing (for frequencies up to 1500 MHz). We demonstrate accurate recovery of 3D dielectric property distributions for breast-like phantoms with tumor inclusions utilizing both the in-plane and new cross-plane data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Developments in LC-MS and Other Hyphenated Techniques

Extensive challenges faced by analytical chemists in studying real world complex samples such as biological body fluids, tissue samples, environmental and geological samples have lead to the development of advanced analytical approaches. The vast array of contemporary technologies can be categorized into two major areas: sample separation and mass spectrometry analysis. Current state-of-the-art sample separation methods include gas chromatography, high performance liquid chromatography, ultra high pressure liquid chromatography, solid phase extraction, capillary electrophoresis, and gas phase separation techniques such as ion mobility spectrometry. The recent trend in sample separation is to combine (or hyphenate) multiple techniques that employ different separation mechanisms to maximize separation efficiency. The most widely used combinations include two-dimensional gas chromatography, strong cation exchange or weak cation exchange chromatography followed by reversed-phase liquid chromatography, two-dimensional reversed-phase liquid chromatography, liquid chromatography followed by ion mobility spectrometry and two-dimensional electrophoresis techniques. The introduction of atmospheric pressure ionization techniques such as electrospray ionization and matrix assisted laser desorption ionization and variations of the two have drastically increased the impact of mass spectrometry on bioanalytical applications. Mass spectrometry itself has tremendously improved over the years in terms of sensitivity, detection limits, dynamic range and sequencing capabilities. Currently, mass spectrometers can attain zeptomolole detection limits with five orders of magnitude dynamic range. In this chapter, we summarize recent developments in hyphenated techniques and their applications to complex sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The MAVEN Magnetic Field Investigation

The MAVEN magnetic field investigation is part of a comprehensive particles and fields subsystem that will measure the magnetic and electric fields and plasma environment of Mars and its interaction with the solar wind. The magnetic field instrumentation consists of two independent tri-axial fluxgate magnetometer sensors, remotely mounted at the outer extremity of the two solar arrays on small extensions ("boomlets"). The sensors are controlled by independent and functionally identical electronics assemblies that are integrated within the particles and fields subsystem and draw their power from redundant power supplies within that system. Each magnetometer measures the ambient vector magnetic field over a wide dynamic range (to 65,536 nT per axis) with a quantization uncertainty of 0.008 nT in the most sensitive dynamic range and an accuracy of better than 0.05%. Both magnetometers sample the ambient magnetic field at an intrinsic sample rate of 32 vector samples per second. Telemetry is transferred from each magnetometer to the particles and fields package once per second and subsequently passed to the spacecraft after some reformatting. The magnetic field data volume may be reduced by averaging and decimation, when necessary to meet telemetry allocations, and application of data compression, utilizing a lossless 8-bit differencing scheme. The MAVEN magnetic field experiment may be reconfigured in flight to meet unanticipated needs and is fully hardware redundant. A spacecraft magnetic control program was implemented to provide a magnetically clean environment for the magnetic sensors and the MAVEN mission plan provides for occasional spacecraft maneuvers - multiple rotations about the spacecraft x and z axes - to characterize spacecraft fields and/or instrument offsets in flight.

Magnetic↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arc minute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

Coronal Imaging with the Solar Ultraviolet Imager

Coronal imaging capabilities of the Solar UltraViolet Imager (SUVI) on the Geostationary Operational Environmental Satellite-16 (GOES-16) are investigated. Launched in 2016, GOES-16 is stationed at 75.2 deg W longitude and accommodates both terrestrial and space weather instruments. SUVI is one of two instruments observing the Sun, providing solar images in six extreme ultraviolet (EUV) wavelengths: 94A, 131A, 171A, 195A, 284A and 304A. Mounted on a two axis gimballed Sun Pointed Platform (SPP), its 53 arcminute square field of view is nominally Sun-centered to provide high dynamic range images in all six wavelengths every four minutes. Analyses of on-orbit data indicated that SUVI had sufficient dynamic range and sensitivity in the 171A and 195A wavelengths to image the corona to the largest heights above the Sun to date while simultaneously imaging the Sun. The 1.6 megapixel Charge Coupled Device (CCD) detector enables the capture of the fine features of the corona. On-orbit calibration tests requiring movement of the SUVI line-of-sight off the Sun, demonstrated that the resulting dynamic disturbance didn't adversely impact the earth-pointing instrument performance. Combining these factors, we conducted a test to assess the performance of SUVI as an EUV extremely wide-field coronal imager by off-pointing the SPP around the Sun and synthesizing an image that's about 4 times the diameter of the Sun. The capability to perform coronal imaging at these two wavelengths is demonstrated by off-pointing the SUVI boresight to nine locations around the Sun and generating a composite coronal image that extends to approx. 4 solar radii. For this purpose, we exploited the satellite's ability to provide stable, fine pointing, even during the slews. Various exposure durations were considered during the first trial and a composite coronal image is obtained for each wavelength. The results are promising. The off-pointing locations and the exposure duration are being refined for the subsequent trials. The routine use of an ultraviolet solar imager as both an imager and a EUV coronagraph would be the first of its kind and is an exciting development. The on-orbit solar coronagraphs to date provide white light images with fields of view extending from 4-15 solar radii. Earlier, Seaton, et al investigated the evolution of the corona in EUV near the solar surface with the data from the Sun Watcher with Active Pixels and Image Processing (SWAP) EUV solar telescope on board the Project for On-Board Autonomy 2 (PROBA2). The presence of corona in EUV even to 4 solar radii is not known. The results of these experiments will begin to fill this void.

Tadikonda, Sivakumara K.↗

A 100,000 pulse height analyzer for use in High Energy Cosmic Ray Experiments (HECRE) on high altitude balloon flights

A description is given of a wide dynamic range pulse height analyzer system developed for use on High Energy Cosmic Ray Experiment (HECRE) Balloon Flights. A wide dynamic range of 100,000 is obtained by extending the range of a basic 1024 channel analyzer through the use of multiple ranges and range selection. The system described here contains four 100,000 pulse height analyzers. Each 100,000 pulse height analyzer consists of a group of cordwood welded modules mounted and interconnected on a printed circuit card. Four of these card assemblies, the required clock drive circuitry (discrete components mounted and interconnected on a separate card) and three input-output connectors are interconnected and mounted on the system board.

Cancro, C. A.↗

Performance comparison for Barnes model 12-1000, Exotech model 100, and Ideas Inc. Biometer Mark 2

Results of tests show that all channels of all instruments, except channel 3 of the Biometer Mark 2, were stable in response to input signals were linear, and were adequately stable in response to temperature changes. The Biometer Mark 2 is labelled with an inappropriate description of the units measured and the dynamic range is a inappropriate for field measurements causing unnecessarily high fractional errors. This instrument is, therefore, quantization limited. The dynamic range and noise performance of the Model 12-1000 are appropriate for remote sensing field research. The field of view and performance of the Model 100A and the Model 12-1000 are satisfactory. The Biometer Mark 2 has not, as yet, been satisfactorily equipped with an acceptable field of view determining device. Neither the widely used aperture plate nor the 24 deg cone are acceptable.

Robinson, B.↗

Optimizing Performance of a Charge-Sensitive Amplifier for the LEGEND-200 Experiment

The observation of neutrinoless double-beta decay would provide evidence for the proposition that neutrinos are their own antiparticle, a property that is not prescribed in the Standard Model. The proposed Large Enriched Germanium Experiment for Neutrinoless double beta Decay (LEGEND) will search for this decay mode in 76Ge by deploying high-purity germanium (HPGe) detectors enriched in this isotope. The signal from two hundred kilograms of HPGe detectors will be fed to low-radioactivity, charge-sensing amplifiers (CSA) deployed in the first phase of the LEGEND experiment: LEGEND-200. We optimized the performance of the CSA in different test conditions by varying the operating parameters (including voltages supplied to the active components of the CSA) and measured the properties of the amplified waveform, such as rise time, dynamic range, and electronic noise. The optimized parameters lead to waveforms with the following characteristics: 90 ns rise time, a dynamic range from 0-10 MeV, and noise of 620 keV (FWHM) at a total power consumption of 156 mW in liquid nitrogen. The optimization process will continue as the circuit is integrated with other components of the experiment.

Lawley, Gannon↗

HIGH RESOLUTION 36 GHz IMAGING OF THE SUPERNOVA REMNANT OF SN 1987A

The aftermath of supernova (SN) 1987A continues to provide spectacular insights into the interaction between an SN blastwave and its circumstellar environment. We here present 36 GHz observations from the Australia Telescope Compact Array of the radio remnant of SN 1987A. These new images, taken in 2008 April and 2008 October, substantially extend the frequency range of an ongoing monitoring and imaging program conducted between 1.4 and 20 GHz. Our 36.2 GHz images have a diffraction-limited angular resolution of 0.''3-0.''4, which covers the gap between high resolution, low dynamic range VLBI images of the remnant and low resolution, high dynamic range images at frequencies between 1 and 20 GHz. The radio morphology of the remnant at 36 GHz is an elliptical ring with enhanced emission on the eastern and western sides, similar to that seen previously at lower frequencies. Model fits to the data in the Fourier domain show that the emitting region is consistent with a thick inclined torus of mean radius 0.''85, and a 2008 October flux density of 27 +- 6 mJy at 36.2 GHz. The spectral index for the remnant at this epoch, determined between 1.4 GHz and 36.2 GHz, is alpha = -0.83. There is tentative evidence for an unresolved central source with flatter spectral index.

79 ASTRONOMY AND ASTROPHYSICS↗

Versatile, reprogrammable area pixel array detector for time-resolved synchrotron x-ray applications

The final technical report for DOE grant DE-SC0004079 is presented. The goal of the grant was to perform research, development and application of novel imaging x-ray detectors so as to effectively utilize the high intensity and brightness of the national synchrotron radiation facilities to enable previously unfeasible time-resolved x-ray research. The report summarizes the development of the resultant imaging x-ray detectors. Two types of detector platforms were developed: The first is a detector platform (called a Mixed-Mode Pixel Array Detector, or MM-PAD) that can image continuously at over a thousand images per second while maintaining high efficiency for wide dynamic range signals ranging from 1 to hundreds of millions of x-rays per pixel per image. Research on an even higher dynamic range variant is also described. The second detector platform (called the Keck Pixel Array Detector) is capable of acquiring a burst of x-ray images at a rate of millions of images per second.

47 OTHER INSTRUMENTATION↗

Texas Instruments /TI/ 800 x 800 charge-coupled device /CCD/ image sensor

Very-large area high-performance CCD image sensors with 800 x 800 pixel format have been successfully fabricated and operated on the basis of a three-level polysilicon gate technology. They are thinned to 8 microns over the entire 12.2 x 12.2 mm active area, and are used in the rear illumination mode. The light transfer characteristic has a gamma value of 1.000 + or - 0.002 over most of the dynamic range. Analysis of the noise behavior shows that the device SNR is shot-noise-limited over most of the dynamic range. Simple on-chip signal processing can be performed using an integration well to noiselessly collect signal charge from multiple pixels prior to reading out the charge. A UV-sensitive phosphor has been applied to the chip, yielding a device capable of imaging at wavelengths from the vacuum UV to the near IR.

Blouke, M. M.↗

Ground-to-Ground Optical Communications Demonstration

A bidirectional horizontal-path optical link was demonstrated between Strawberry Peak (SP), Lake Arrowhead, California, and the JPL Table Mountain Facility (TMF), Wrightwood, California, during June and November of 1998. The 0.6-m telescope at TMF was used to broadcast a 4-beam 780-nm beacon to SP. The JPL-patented Optical Communications Demonstrator (OCD) at SP received the beacon, performed ne tracking to compensate for the atmosphere-induced beacon motion and retransmitted a 844-nm communications laser beam modulated at 40 to 500 Mb/s back to TMF. Characteristics of the horizontal-path atmospheric channel as well as performance of the optical communications link were evaluated. The normalized variance of the irradiance fluctuations or scintillation index delta2/I at either end was determined. At TMF where a single 844-nm beam was received by a 0.6-m aperture, the measured delta2/I covered a wide range from 0.07 to 1.08. A single 780-nm beam delta2/I measured at SP using a 0.09-m aperture yielded values ranging from 0.66 to 1.03, while a combination of four beams reduced the scintillation index due to incoherent averaging to 0.22 to 0.40. This reduction reduced the dynamic range of the fluctuations from 17 to 21 dB to 13 to 14 dB as compared with the OCD tracking sensor dynamic range of 10 dB. Predictions of these values also were made based on existing theories and are compared. Generally speaking, the theoretical bounds were reasonable. Discussions on the probability density function (PDF) of the intensity fluctuations are presented and compared with the measurements made. The lognormal PDF was found to agree for the weak scintillation regime as expected. The present measurements support evidence presented by earlier measurements made using the same horizontal path, which suggests that the aperture averaging effect is better than theoretically predicted.

Biswas, A.↗

AugerPrime surface detector electronics

Operating since 2004, the Pierre Auger Observatory has led to major advances in our understanding of the ultra-high-energy cosmic rays. The latest findings have revealed new insights that led to the upgrade of the Observatory, with the primary goal of obtaining information on the primary mass of the most energetic cosmic rays on a shower-by-shower basis. In the framework of the upgrade, called AugerPrime, the 1660 water-Cherenkov detectors of the surface array are equipped with plastic scintillators and radio antennas, allowing us to enhance the composition sensitivity. To accommodate new detectors and to increase experimental capabilities, the electronics is also upgraded. This includes better timing with up-to-date GPS receivers, higher sampling frequency, increased dynamic range, and more powerful local processing of the data. In this paper, the design characteristics of the new electronics and the enhanced dynamic range will be described. The manufacturing and test processes will be outlined and the test results will be discussed. The calibration of the SD detector and various performance parameters obtained from the analysis of the first commissioning data will also be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lidar System for Airborne Measurement of Clouds and Aerosols

A lidar system for measuring optical properties of clouds and aerosols at three wavelengths is depicted. The laser transmitter is based on a Nd:YVO4 laser crystal pumped by light coupled to the crystal via optical fibers from laser diodes that are located away from the crystal to aid in dissipating the heat generated in the diodes and their drive circuits. The output of the Nd:YVO4 crystal has a wavelength of 1064 nm, and is made to pass through frequency-doubling and frequency-tripling crystals. As a result, the net laser output is a collinear superposition of beams at wavelengths of 1064, 532, and 355 nm. The laser operates at a pulse-repetition rate of 5 kHz, emitting per-pulse energies of 50 microJ at 1064 nm, 25 microJ at 532 nm and 50 microJ at 355 nm. An important feature of this system is an integrating sphere located between the laser output and the laser beam expander lenses. The integrating sphere collects light scattered from the lenses. Three energy-monitor detectors are located at ports inside the integrating sphere. Each of these detectors is equipped with filters such that the laser output energy is measured independently for each wavelength. The laser output energy is measured on each pulse to enable the most accurate calibration possible. The 1064-nm and 532-nm photodetectors are, more specifically, single photon-counting modules (SPCMs). When used at 1064 nm, these detectors have approximately 3% quantum efficiency and low thermal noise (fewer than 200 counts per second). When used at 532 nm, the SPCMs have quantum efficiency of about 60%. The photodetector for the 355-nm channel is a photon-counting photomultiplier tube having a quantum efficiency of about 20%. The use of photon-counting detectors is made feasible by the low laser pulse energy. The main advantage of photon-counting is ease of inversion of data without need for complicated calibration schemes like those necessary for analog detectors. The disadvantage of photon-counting detectors is that they inherently have narrow dynamic ranges. However, by using photon-counting detectors along with a high-repetition rate laser, it is possible to obtain wide dynamic range through accumulation of counts over many pulses.

McGill, Matthew↗

Radiometric infrared focal plane array imaging system for thermographic applications

This document describes research performed under the Radiometric Infrared Focal Plane Array Imaging System for Thermographic Applications contract. This research investigated the feasibility of using platinum silicide (PtSi) Schottky-barrier infrared focal plane arrays (IR FPAs) for NASA Langley's specific radiometric thermal imaging requirements. The initial goal of this design was to develop a high spatial resolution radiometer with an NETD of 1 percent of the temperature reading over the range of 0 to 250 C. The proposed camera design developed during this study and described in this report provides: (1) high spatial resolution (full-TV resolution); (2) high thermal dynamic range (0 to 250 C); (3) the ability to image rapid, large thermal transients utilizing electronic exposure control (commandable dynamic range of 2,500,000:1 with exposure control latency of 33 ms); (4) high uniformity (0.5 percent nonuniformity after correction); and (5) high thermal resolution (0.1 C at 25 C background and 0.5 C at 250 C background).

Esposito, B. J.↗

Evaluation of CEA SMAD Digitizer for CTBTO-IMS Application (2012)

Sandia National Laboratories has tested and evaluated the new SMAD digitizer (revision A) design by CEA, France. The digitizer was tested at the acquisition rate of 50 Hz and gain factors of 1x, 2x, 4x, and 8x. The purpose of this digitizer evaluation was to perform seismic system noise analysis with estimates of system band-width dynamic range for an STS2 application and to determine the following device specifications: bit-weight, input terminated noise with a 2x50 Ohms load, bandwidth limited dynamic range, power consumption, common-mode rejection, cross-talk, analog bandwidth, relative transfer function, total harmonic distortion, time-tag accuracy, time-tag statistics, and time-tag drift. The test results included in this report were in response to static and to tonal-dynamic input signals. Wherever possible test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters.

42 ENGINEERING↗

Extension of the energy range accessible with a TES using bath temperature variations

The energy range of transition-edge sensor (TES) X-ray microcalorimeters with a multiplexed readout depends upon the width and shape of the TES superconducting transition, and also on the dynamic range of the readout. In many detector systems, the multiplexed readout slew rate capability will be the limiting factor for the energy range. In these cases, if we are willing to accept some energy resolution degradation, we can significantly extend the energy range by increasing the bath temperature of operation, essentially creating a second “extended energy range” mode of operation. For example, if we require the very highest energy resolution up to 7 keV, and wish to optimize the design up to this energy, for some measurements it could be very beneficial to have a mode where we can extend the energy range to 15–20 keV even if some energy resolution is sacrificed. In this paper, we explore the trade-off between dynamic range and energy resolution from changing the bath temperature of the TES. We present measurements of TES resolution and slew rate as a function of bath temperature and compare to numerical simulations.

S Beaumont↗