Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Management System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Aromatic amino acid metabolism and active transport regulation are implicated in microbial persistence in fractured shale reservoirs

Abstract Hydraulic fracturing has unlocked vast amounts of hydrocarbons trapped within unconventional shale formations. This large-scale engineering approach inadvertently introduces microorganisms into the hydrocarbon reservoir, allowing them to inhabit a new physical space and thrive in the unique biogeochemical resources present in the environment. Advancing our fundamental understanding of microbial growth and physiology in this extreme subsurface environment is critical to improving biofouling control efficacy and maximizing opportunities for beneficial natural resource exploitation. Here, we used metaproteomics and exometabolomics to investigate the biochemical mechanisms underpinning the adaptation of model bacterium Halanaerobium congolense WG10 and mixed microbial consortia enriched from shale-produced fluids to hypersalinity and very low reservoir flow rates (metabolic stress). We also queried the metabolic foundation for biofilm formation in this system, a major impediment to subsurface energy exploration. For the first time, we report that H. congolense WG10 accumulates tyrosine for osmoprotection, an indication of the flexible robustness of stress tolerance that enables its long-term persistence in fractured shale environments. We also identified aromatic amino acid synthesis and cell wall maintenance as critical to biofilm formation. Finally, regulation of transmembrane transport is key to metabolic stress adaptation in shale bacteria under very low well flow rates. These results provide unique insights that enable better management of hydraulically fractured shale systems, for more efficient and sustainable energy extraction.

04 OIL SHALES AND TAR SANDS↗

Considerations for Managing DOE Standard Canisters within an Over-canister as Part of an Integrated Waste Management System PPT

To better enable informed decision making regarding the back-end of the nuclear fuel cycle, the Integrated Waste Management Program within the U.S. Department of Energy, Office of Nuclear Energy (DOE-NE) has been sponsoring research into a comprehensive integrated waste management system (IWMS) that considers all major back-end aspects of the nuclear fuel cycle (i.e., transportation, storage, and disposal). An important aspect of the IWMS is DOE-managed Spent Nuclear Fuel (SNF). DOE and its predecessor agencies have generated, transported, received, stored, and reprocessed SNF at DOE facilities nationwide, and DOE is responsible for managing the SNF currently in its possession. These fuels come from a wide range of reactor types that employ various cladding materials, fuel materials, and enrichments. To enable interim, road-ready dry storage (RRDS) of the wide variety of SNF types found in the DOE inventory, a standardized canister system (i.e., the DOE Standard Canister) was proposed for the packaging demonstration. This robust, welded canister system is designed to confine radionuclides, prevent criticality by precluding content moderation, and satisfy other requirements as part of a larger storage, transportation, and disposal system. While SNF has yet to be loaded into a DOE Standard Canister, DOE Standard Canister designs were included in past storage facility and disposal facility design licensing endeavors. In a renewed effort to evaluate packaging SNF at Idaho National Laboratory (INL) in a RRDS configuration, researchers are planning the RRDS Packaging Demonstration. This demonstration is supplemented by analytical structural, criticality, and material compatibility evaluations that support management of SNF in DOE Standard Canisters, taking advantage of past analysis work to the extent possible. One of the largest differences between the current Packaging Demonstration and past analytical evaluations is the inclusion of an over-canister containing multiple DOE Standard Canisters. For the Packaging Demonstration, DOE Standard Canisters loaded with SNF are planned to be placed in a larger diameter over-canister. The sealed over-canister could then be placed in a storage overpack for onsite storage, or in a transportation overpack for shipment to an offsite storage location or disposal site once one becomes available. This paper examines the relevant considerations and provides a preliminary evaluation of integrating the over-canister configuration into the storage, transportation, and disposal processes of the overall waste management system. For storage and transportation, the over-canister can be considered analogous to a multi-purpose canister (MPC) for commercial SNF. For disposal, the DOE Standard Canisters could be removed from the over-canister and placed in a co-disposal waste package with canisters containing vitrified high-level radioactive waste (HLW) similar to configurations examined previously, or the sealed over-canisters might be capable of direct disposal in a waste package.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Factors Influencing the Decisions and Actions of Pilots and Air Traffic Controllers in Three Plausible NextGen Environments

In the current air traffic management (ATM) system, pilots and air traffic controllers have well-established roles and responsibilities: pilots fly aircraft and are concerned with energy management, fuel efficiency, and passenger comfort; controllers separate aircraft and are concerned with safety and management of traffic flows. Despite having different goals and obligations, both groups must be able to effectively communicate and interact with each other for the ATM system to work. This interaction will become even more challenging as traffic volume increases dramatically in the near future. To accommodate this increase, by 2025 the national air transportation system in the U.S. will go through a transformation that will modernize the ATM system and make it safer, more effective, and more efficient. This new system, NextGen, will change how pilots and controllers perform their tasks by incorporating advanced technologies and employing new procedures. It will also distribute responsibility between pilots, controllers and automation over such tasks as maintaining aircraft separation. The present chapter describes three plausible concepts of operations that allocate different ATM responsibilities to these groups. We describe how each concept changes the role of each operator and the types of decisions and actions performed by them.

Vu, Kim-Phuong L.↗

Understanding Electric Vehicle Range and Charging Needs: Interactions Between Ambient Temperature, Commute Patterns, and State-of-Charge Usage

Electric vehicle (EV) performance can vary substantially under real-world operating conditions, particularly due to ambient temperature effects on energy consumption, battery behavior, and thermal management requirements. This study quantifies how weather conditions, daily driving patterns, and State-of-Charge (SOC) usage strategies jointly influence EV driving range, charging frequency, and overall energy efficiency. A detailed and experimentally validated Autonomie vehicle model is developed, integrating a powertrain, a mono-zonal cabin model, and a battery electro-thermal model. Three battery sizes (200-, 300-, and 400-mile homologated ranges) are assessed across five commute profiles (20–200 miles) and six ambient temperatures (−18 °C to 50 °C), including scenarios with and without preconditioning. Results show that extreme temperatures could significantly decrease the maximum achievable range by up to 55% in cold conditions (−18 °C) and 40% in hot conditions (50 °C), relative to moderate conditions. Larger battery packs retain a greater fraction of their nominal range under thermal stress, while smaller packs experience sharper relative penalties due to the higher contribution of thermal loads to total energy demand. The analysis further demonstrates that limiting operation to partial SOC windows (e.g., 80–20%), a common real-world practice, significantly reduces achievable range and increases charging frequency, particularly in cold weather. Thermal preconditioning while plugged in is shown to mitigate these effects for short trips, reducing energy consumption by up to 31% in hot conditions and 7% in cold conditions. The findings demonstrate how climate, SOC usage behavior, and thermal management jointly shape the practical driving capability of EVs, highlighting the importance of efficient thermal management and realistic user charging strategies for ensuring reliable EV operation across diverse climatic scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Leveraging Energy Sales Agreements (ESA) Under ESPC ENABLE and DOE's IDIQ Contract

There is an increasing interest in solar photovoltaics, battery energy storage systems, and geothermal heat pumps to help meet decarbonization and resilience goals. However, facility managers may not know that energy sales agreement (ESA) contracting can be an effective, efficient, and lower cost way to procure and install these projects. FEMP, national labs, and agency partners will discuss best practices and examples that attendees may be able to leverage at their own sites.

DOE FEMP↗

Cost-optimized energy storage operation for a grid-connected solar PV system at community and individual scales

This study provides a comparative analysis of grid-connected PV-integrated battery storage at individual and community scales. The paper addresses the challenge of managing energy demand-generation mismatch by using a battery energy storage optimization algorithm, which minimizes operational costs while accounting for battery degradation. Also, this work introduces a broader evaluation basis that includes seasonal variability, grid exchange smoothness, and scalability across different battery capacities. Results show that community-scale storage more effectively dampens grid exchange power fluctuations and reduces system costs, particularly with moderate price differences between electricity buying and selling prices and low battery capacities. The paper also analyzes the impacts of static control versus cost-optimized battery system management. Here, it is shown that the gap in system costs between the cost-optimized and static control scenarios widens as the price difference increases.

25 ENERGY STORAGE↗

A Systems Model for Power Technology Assessment

A computer model is under continuing development at NASA Glenn Research Center that enables first-order assessments of space power technology. The model, an evolution of NASA Glenn's Array Design Assessment Model (ADAM), is an Excel workbook that consists of numerous spreadsheets containing power technology performance data and sizing algorithms. Underlying the model is a number of databases that contain default values for various power generation, energy storage and power management and distribution component parameters. These databases are actively maintained by a team of systems analysts so that they contain state-of-art data as well as the most recent technology performance projections. Sizing of the power subsystems can be accomplished either by using an assumed mass specific power (W/kg) or energy (Wh/kg) or by a bottoms-up calculation that accounts for individual component performance and masses. The power generation, energy storage and power management and distribution subsystems are sized for given mission requirements for a baseline case and up to three alternatives. This allows four different power systems to be sized and compared using consistent assumptions and sizing algorithms. The component sizing models contained in the workbook are modular so that they can be easily maintained and updated. All significant input values have default values loaded from the databases that can be over-written by the user. The default data and sizing algorithms for each of the power subsystems are described in some detail. The user interface and workbook navigational features are also discussed. Finally, an example study case that illustrates the model's capability is presented.

Hoffman, David J.↗

Enhancing Power Resilience for Remote Communities: A Comprehensive Renewable Energy Solution for Itbayat Island

The island of Itbayat, Philippines, faces significant challenges in maintaining a reliable and resilient power supply due to its current reliance on a vulnerable power distribution system managed by a local electric cooperative. The existing infrastructure, which includes diesel generators and a radial network configuration with some above-ground lines, is highly susceptible to frequent typhoons and adverse weather conditions. These factors, combined with inadequate staffing and high operational costs, result in frequent power outages that disrupt daily life and hinder economic development. This white paper proposes a comprehensive solution to enhance the resilience and reliability of Itbayat's power system by integrating renewable energy sources, specifically solar photovoltaic (PV) systems, battery storage, and a microgrid controller. The proposed solution aims to reduce dependency on diesel fuel, optimize energy use, and provide a sustainable and robust power supply for the island. Key components of the solution include: 1. Solar PV Installation: Deploying solar PV panels to harness abundant solar energy, reducing reliance on diesel fuel. 2. Battery Storage Systems: Installing battery storage to store excess solar energy and ensure a continuous power supply during low solar generation periods. 3. Microgrid Controller: Implementing a microgrid controller to manage and optimize the integration of solar PV, battery storage, and existing diesel generators. The proposed solution addresses several critical issues, including system vulnerability, generator dependency, and operational inefficiencies. By adopting this innovative approach, Itbayat Island can achieve a more resilient, efficient, and sustainable energy infrastructure, ensuring a stable power supply for its residents and enhancing overall energy security.

14 SOLAR ENERGY↗

SULI End of Summer Presentation

This presentation made on Power Point is a brief summary of my work enhancing the Supervisory Control and Data Acquisition (SCADA) architecture for Idaho National Lab’s Critical Infrastructure Test Range Complex (CITRC). This work was part of an on-going project to create a digital twin of CITRC that will be implemented for resiliency research. Resiliency is growing more important as extreme weather, aging infrastructure, and increasing load all exert stress on the United States power grid. This presentation highlights how I documented the existing devices and data flow on site and then updated specific device settings to better support the needs of the project. It also examines future use of this data in the digital twin data warehouse (DeepLynx), and future Artificial Intelligence and Advanced Distribution Management System applications. It will be presented to the B751 Water and Energy Systems Analysis group at INL during my last week.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

How Improved Forecasting Can Increase the Bulk Power System Value of Price-Responsive Electric Vehicle Managed Charging

Personal light-duty vehicle (LDV) electric vehicle managed charging (EVMC) can reduce power system costs by better aligning electric vehicle (EV) charging with locations and times of low energy cost or infrastructure use. The need to coordinate charging demand across thousands to millions of vehicles while preserving mobility service is a barrier to realizing the value of EVMC. Price-responsive dispatch mechanisms like time-of-use rates (TOU) and hourly real-time prices (RTP) are attractive compared to direct load control (DLC) because they only require one-way communications and local controls. However, increasing participation in price responsive mechanisms can induce costly-to-serve spikes in load and otherwise increase, rather than decrease, production costs. We quantify the ability of improved EVMC forecasting to sustain savings from price responsive mechanisms beyond the limit of 14% of LDVs actively participating observed in previous work. Perfect forecasting of price-responsive EV load makes TOU and RTP value-competitive with a low-error DLC formulation with up to 27% (within-week flexibility) to 45% or more (within-session flexibility) of LDVs participating in EVMC in an envisioned New England power system with 84% clean energy. Additional costs of implementing DLC should be no more than tens of dollars per vehicle-year if DLC is to be value-competitive with accurately forecast price-responsive EVMC for double-digit percentage shares of LDVs participating.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mars Sample Return, Sample Retrieval Lander, Reaction Control System Jet Interaction Supersonic Wind Tunnel Test Overview with CFD Predictions

NASA's Mars Sample Return campaign will be launching several missions over the next decade that will work together to return rock samples from Mars back to Earth. The Sample Retrieval Lander (SRL) will deliver the Mars Ascent Vehicle and fetch rover to the surface of Mars in 2006. Rock samples collected by the Mars 2020 Perseverance rover, landing in early 2021, will be loaded on the the ascent vehicle to be launched into Mars orbit for retrieval by yet another spacecraft. The Sample Retrieval Lander will be a blunt entry capsule similar to past Mars entry vehicles like Mars Science Laboratory and Viking. The vehicle will fly a guided entry, using a small lift vector produced by a non-zero trim angle of attack to eliminate downrange and crossrange position errors at the point of parachute deploy. This energy and heading management is achieved with a reaction control system (RCS) that directs the bank angle of the vehicle and also minimizes unwanted capsule dynamics. The reaction control system and control design is based on the Mars Science Laboratory and Mars 2020 RCS systems. However, due to packaging constraints, the backshell of this new entry vehicle has a different geometry than those earlier designs. To certify the RCS system for flight the project must characterize the jet plume interactions with the capsule backshell that could impair or significantly augment the RCS control authority. This characterization will be done through a combination of computational fluid dynamics (CFD) analysis and wind tunnel test. Two candidate arrangements of the RCS jets have been identified for the SRL vehicle and are currently under evaluation before final selection. The aero/RCS plume interactions of these candidate configurations have been measured in a supersonic wind tunnel test in NASA Langley's Unitary Plan Wind Tunnel. The test was conducted in the fall of 2020 and data is currently being reduced. An overview of the candidate RCS configurations are presented here with an overview of the wind tunnel model design, jet scaling and scaled nozzle design, and the test matrix. Preliminary CFD runs are presented with an assessment of the predicted plumes and their interaction with the wake flow of the vehicle. The predicted effects of the model sting is provided as well. This high fidelity wind tunnel test is being conducted much earlier in the SRL project than would normally be done. The test was funded as part of a CFD evaluation task funded by NASA's Aerosciences Evaluation and Test Capabilities Project. The objective of the evaluation task was to compare the ability of CFD to predict complex flows with data that can be measured in the Langley Unitary Plan Wind Tunnel. RCS Jet interactions were selected as a type of complex flow that is important to NASA missions. In addition to providing useful data to the SRL project, there was added emphasis on quantifying the accuracy of the CFD predictions and wind tunnel test data. An overview of the uncertainty quantification methodologies for computational and experimental portions of this test is presented.

blunt body↗

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE↗

Buildings Sector Scenarios: Demand-side data to support energy system planning in the United States

The US energy system is in a period of high uncertainty about load growth, its implications for the energy generation mix, and downstream impacts on customer energy costs. In this context, there is a need for comprehensive, credible, and readily-customized projections of energy demand to ensure that planning decisions account for end-use management opportunities to improve system reliability and affordability. Here we introduce the Buildings Sector Scenarios (BSS) dataset, which includes a benchmark suite of such projections for the buildings sector — a key source of energy consumption, peak electricity demand, and consumer energy expenditures. The dataset contains projections through 2050 covering the contiguous United States (CONUS) resolved down to the county, hourly level by sector and end use for electricity demand and to the state, annual level by sector and end use for non-electric fuels. We summarize the BSS analysis workflow and the tools and datasets that support it, document key BSS scenario inputs and modeling assumptions, and outline BSS scenario outputs. We assess the technical quality of the dataset against historical surveys and projected estimates of buildings sector demand. Finally, we provide guidance on how stakeholders can access, use, and reproduce the dataset, and/or create new scenarios to explore their own analysis questions.

Langevin, Jared↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online and Offline Identification of False Data Injection Attacks in Battery Sensors Using a Single Particle Model

The cells in battery energy storage systems are monitored, protected, and controlled by battery management systems whose sensors are susceptible to cyberattacks. False data injection attacks (FDIAs) targeting batteries’ voltage sensors affect cell protection functions and the estimation of critical battery states like the state of charge (SoC). Inaccurate SoC estimation could result in battery overcharging and over discharging, which can have disastrous consequences on grid operations. This paper proposes a three-pronged online and offline method to detect, identify, and classify FDIAs corrupting the voltage sensors of a battery stack. To accurately model the dynamics of the series-connected cells a single particle model is used and to estimate the SoC, the unscented Kalman filter is employed. FDIA detection, identification, and classification was accomplished using a tuned cumulative sum (CUSUM) algorithm, which was compared with a baseline method, the chi-squared error detector. Online simulations and offline batch simulations were performed to determine the effectiveness of the proposed approach. Throughout the batch simulations, the CUSUM algorithm detected attacks, with no false positives, in 99.83% of cases, identified the corrupted sensor in 97% of cases, and determined if the attack was positively or negatively biased in 97% of cases.

25 ENERGY STORAGE↗

Space station electrical power distribution analysis using a load flow approach

The space station's electrical power system will evolve and grow in a manner much similar to the present terrestrial electrical power system utilities. The initial baseline reference configuration will contain more than 50 nodes or busses, inverters, transformers, overcurrent protection devices, distribution lines, solar arrays, and/or solar dynamic power generating sources. The system is designed to manage and distribute 75 KW of power single phase or three phase at 20 KHz, and grow to a level of 300 KW steady state, and must be capable of operating at a peak of 450 KW for 5 to 10 min. In order to plan far into the future and keep pace with load growth, a load flow power system analysis approach must be developed and utilized. This method is a well known energy assessment and management tool that is widely used throughout the Electrical Power Utility Industry. The results of a comprehensive evaluation and assessment of an Electrical Distribution System Analysis Program (EDSA) is discussed. Its potential use as an analysis and design tool for the 20 KHz space station electrical power system is addressed.

Emanuel, Ervin M.↗

Spatially and Temporally Detailed Water and Carbon Footprints of U.S. Electricity Generation and Use

Electricity generation in the United States entails significant water usage and greenhouse gas emissions. However, accurately estimating these impacts is complex due to the intricate nature of the electric grid and the dynamic electricity mix. Existing methods to estimate the environmental consequences of electricity use often generalize across large regions, neglecting spatial and temporal variations in water usage and emissions. Consequently, electric grid dynamics, such as temporal fluctuations in renewable energy resources, are often overlooked in efforts to mitigate environmental impacts. The U.S. Department of Energy (DOE) has initiated the development of resilient energyshed management systems, requiring detailed information on the local electricity mix and its environmental impacts. This study supports DOE's goal by incorporating geographic and temporal variations in the electricity mix of the local electric grid to better understand the environmental impacts of electricity end users. We offer hourly estimates of the U.S. electricity mix, detailing fuel types, water withdrawal intensity, and water consumption intensity for each grid balancing authority through our publicly accessible tool, the Water Integrated Mapping of Power and Carbon Tracker (Water IMPACT). While our primary focus is on evaluating water intensity factors, our dataset and programming scripts for historical and real-time analysis also include evaluations of carbon dioxide (equivalence) intensity within the same modeling framework. This integrated approach offers a comprehensive understanding of the environmental footprint associated with electricity generation and use, enabling informed decision-making to effectively reduce Scope 2 water usage and emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗