Search NASA⌕ Search

SEARCH · Search NASA

Results for “Engineering - Other instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

APS Science 2020 (Vol. 1)

The U.S. Department of Energy's Advanced Photon Source (APS) is one of the world’s most productive x-ray light source facilities. Each year, the APS provides high-brightness x-ray beams to a diverse community of more than 5,000 researchers in materials science, chemistry, condensed matter physics, the life and environmental sciences, and applied research. Researchers using the APS produce over 2,000 publications each year detailing impactful discoveries, and solve more vital biological protein structures than users of any other x-ray light source research facility. APS x-rays are ideally suited for explorations of materials and biological structures; elemental distribution; chemical, magnetic, electronic states; and a wide range of technologically important engineering systems from batteries to fuel injector sprays, all of which are the foundations of our nation’s economic, technological, and physical well-being. The APS occupies an 80-acre site on the Argonne campus, about 25 miles from downtown Chicago, Illinois. It shares a site with the Center for Nanoscale Materials and the Advanced Protein Characterization Facility.

25 ENERGY STORAGE↗

Femtosecond Reflectance Spectroscopy for Energetic Material Diagnostics

Understanding the fundamental mechanisms underpinning shock initiation is critical to predicting energetic material (EM) safety and performance. Currently, the timescales and pathways by which shock-excited lattice modes transfer energy into specific chemical bonds remains an open question. Towards understanding these mechanisms, our group has previously measured the vibrational energy transfer (VET) pathways in several energetic thin films using broadband, femtosecond transient absorption spectroscopy. However, new technologies are needed to move beyond these thin film surrogates and measure broadband VET pathways in realistic EM morphologies. Herein, we describe a new broadband, femtosecond, attenuated total reflectance spectroscopy apparatus. Performance of the system is benchmarked against published data and the first VET results from a pressed EM pellet are presented. This technology enables fundamental studies of VET dynamics across sample configurations and environments (pressure, temperature, etc .) and supports the potential use of VET studies in the non-destructive surveillance of EM components.

42 ENGINEERING↗

Digital Infrastructure Migration Framework Report

This document presents a full-scope Digital Infrastructure implementation and associated lifecycle support recommendations that enable a plant life of 80+ years. Specific technologies and software applications are researched, developed, selected, implemented, and then integrated by utilities to enhance safety, reliability, and economic performance such that the result provides much more than the sum of its parts. Specific selection of these technologies is driven by business case analyses which are utility, station, and unit specific.

42 ENGINEERING↗

IER-539 CED-1: Preliminary Design of a New Horizontal Split Table

This report presents the preliminary design (CED-1) of IER-539, focused on a new Horizontal Split Table (HST) critical assembly machine. The Department of Energy (DOE) National Nuclear Criticality Safety Program (NCSP) funds critical experiment R&D and its Mission and Vision document identifies a long-standing technical gap of a general purpose HST. HSTs have historically been used for experiments that are impractical to assemble on a vertical lift machine (VLM), usually due to their large physical size or weight. While many HSTs were historically employed in the US (including at LLNL), there are currently no surviving HSTs in the US. While there are two critical experiments facilities remaining in the US, the National Critical Experiments Research Center (NCERC) operated by LANL and the Critical Experiments Facility (CX) operated by SNL, these facilities are not equipped with a general purpose HST. There are a number of experiment designs that require an HST, including needs for Defense Programs and Nuclear Energy. Lack of an HST constraints the national ability to perform large and heavy experiments. Large footprints are needed to successfully create mockup experiments for advanced reactors (mock-up cold critical reactor cores, which is a urgent need for new reactor designs using novel materials and longer cycle lengths), to create solution experiments in lattices, or to test nuclear data of heavy metals. A new HST is a vital piece of criticality experiment infrastructure that would allow for the conduct of integral critical experiments to address needs in the nuclear criticality safety, nuclear data, and other DOE stakeholder communities.

42 ENGINEERING↗

Flow Sensor Test Article (F-STAr) - Status Report for FY2021

This report will review updates on the status of F-STAr. First, the report will describe a general overview of the test article and how each component interacts. Then, each main component will be discussed in a deep dive section which will review the design and other relevant details. F-STAr components which are discussed in more detail include the 120 GPM-pump, the support structure and test sections, 5 kW-heater, the 2 kW-cooler and cooling system, and the submersible flowmeter. Finally, this report will conclude with a brief recap and a bulleted outline of the path moving forward.

42 ENGINEERING↗

High Fidelity Tomographic Density Reconstructions [Slides]

Pressed high explosives have small density variations associated with the pressing process, from a few to sub percent depending on the material. Variations at these levels are known to have an impact on HE performance. Currently, a destructive testing method based on physical sectioning followed by immersion density measurements (slice and dice) is utilized. However, this method has poor spatial resolution limited by the the sectioning size, 1-2 cm. If possible, radiographic methods including Computed Tomography (CT) would be preferred, as they are non-destructive and have higher (less than .1 mm) spatial resolution. However, beam hardening, scattered radiation, and detector effects make density reconstructions at this level extremely challenging.

42 ENGINEERING↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Cineradiography System and Initial 3D-printed Brain Phantoms

Traumatic brain injury (TBI) is a significant cause of death in tactical, sport and civilian populations. According to the Center for Disease Control (CDC) report in 2016, TBI accounted for 227,000 hospitalizations and 60,000 related deaths. In the military, the prevalence of traumatic brain injuries is related to the type of conflict U.S. forces are involved in and are typically classified as mild traumatic brain injuries (mTBIs). Troops returning from Operation Enduring Freedom and Operation Iraqi Freedom had a TBI rate estimated at 15.2% to 22.8%; nearly 320,000 troops. These mTBIs were primarily blast-induced and often lacked any accompanying symptoms. Left untreated, these mild injuries have been linked to chronic disorders and cognitive alterations. One such disorder that has been frequently recorded in literature is chronic traumatic encephalopathy (CTE). CTE is a progressive neurodegenerative tauopathy resulting from repetitive mTBIs. The repetitive head injuries involved in sport, classified as mTBIs, has resulted in CTE development in athletes involved in contact sports. While the association between mTBIs and CTE has been pathologically verified, the mechanisms have yet to be identified. In order to better understand these mechanisms, the use of flash x-ray radiography is being considered.

42 ENGINEERING↗

FY2021 Report on Magnetic Microcalorimeter Development for the IAEA NML

The goal of this project is to develop high-resolution decay energy spectroscopy (DES) of actinides using magnetic microcalorimeters (MMCs). This requires testing different techniques to fully enclose a source inside an absorber and coupling it to an MMC with optimized energy resolution and speed. The goal is to develop DES with MMCs to allow its transfer to the IAEA Nuclear Materials Laboratory (NML).

42 ENGINEERING↗

Summer 2021 Co-op Report: X-Ray Scintillation Detector (A Co-op Work Experience Report)

The M-3 team was in need of a detector that could be used properly characterize their X-Ray machines. It can also be used to diagnose the X-ray in the case that problems arise before or during an experiment. They put me in charge of designing, ordering, and constructing said detector. After doing research, I found that scintillation-based detectors would be the best diagnostic tool for this purpose. It will allow the team to collect a full photon count of the X-ray pulse as well as provide spectroscopy functions with which we can view photon counts at different energy levels. This will also allow them to calculate an accurate dose given from the machine. Due to lead times, the crystals are still in manufacturing, thus the detector could not be completed. Although the designs and calculations needed to construct and operate the scintillator have been completed which is what I will be presenting in this document. Compared to the detectors being used before, my design offers a cheaper and far more efficient alternative.

42 ENGINEERING↗

Requirements Documents for the Large Mechanical Parts Precision Cleaner (LMPPC) in the Optics Assembly Building (OAB)

The National Ignition Facility (NIF) is the world's largest energetic laser whose missions include sresearch in inertial confinement fusion, experiments for the Stockpile Stewardship, and other high fluence laser research. Due to the high fluence of lasers, extreme environmental conditions, and radiation presence, all mechanical parts (metal, plastic, etc.) installed on NIF must be precision cleaned. Precision cleaned parts are also required in supporting facilities like the Optics Processing Facility (OPF). Small debris inside the laser beams or on optics can cause optic damage, interfere with diagnostics, and interfere with experiments.

42 ENGINEERING↗

Legacy surface change analyses of the 1993 Rock Valley earthquake sequence for direct comparison to planned NA-22 underground conventional high-explosive experiments (Source Physics Experiment 3 (SPE3) - RV/DC Task 1.3 FY22 Final Report)

Recent work under two previous phases of the NNSA NA-22 Source Physics Experiment (SPE) have shown that underground chemical high-explosive experiments can produce detectable surface changes that differ in spatial extent and vertical magnitude depending on the geologic media at the site (Schultz-Fellenz et al., 2018; 2020; Crawford et al., 2021). Neither of these two prior phases of SPE identified natural earthquake-related surface effects in the same region that occurred at a similar depth as the explosive experiments for direct comparison. While earthquakes can also produce surface changes that are detectable using remote sensing data analyses, it is expected that the pattern and spatial extent of surface changes would vary between earthquakes and explosions. However, no direct-observed surface-change signature comparison between earthquakes and explosions has ever been performed. The SPE Phase 3 Rock Valley/Direct Comparison (RV/DC) program presents a unique opportunity to investigate and characterize co-occurrence of both earthquakes and explosions. In this project, we worked to address five tasks in a workflow, as follows: 1. Identify and obtain existing high-resolution legacy satellite and aerial imagery as close in time before and after the 1993 Rock Valley earthquake sequence to temporally constrain the analyses. 2. Transform these pre-earthquake and post-earthquake datasets into digital elevation models (DEMs) using geospatial analysis software packages (e.g., ArcGIS, Agisoft Metashape, and Google Earth Engine). 3. Perform DEM differencing analyses to assess and quantify earthquake-related changes from the 1993 sequence, and develop map products that visualize these analyses. 4. Use the analyses from (3) to: (a) assess spatial distribution and magnitude of surface changes due to the 1993 Rock Valley earthquake sequence, and (b) determine parameters of forthcoming, planned explosion-related surface change data collection from sensors mounted on unmanned aerial vehicles (UAVs) (e.g., spatial extent of collection, design and density of survey control, sensors to deploy, forward speed and line spacing of UAV flight lines, flight altitude). 5. Develop a summary report on the analyses, including how the analyses define parameters and identify focus areas for any future surface change analytical field campaigns related to the explosive experiment. Analyzing these legacy data and identifying whether they can detect any surface changes related to the earthquake sequence facilitates opportunities for direct signature comparison of surface change from explosions at one location, which has never previously been performed. Comparing the surface change signatures from a co-located and depth-equivalent earthquake and an explosion could help to advance remote sensing event discrimination techniques. This report summarizes the work completed toward this ambitious goal.

42 ENGINEERING↗

Microstructural Effects of PETN on Detonator Performance

The strategic motivation of the project is guided by the Need to understand: material characteristics important to performance; how to most appropriately measure/monitor these characteristics; and, evolution of these characteristics through lifetime and storage conditions.

36 MATERIALS SCIENCE↗

Criticality Safety Calculations for General Handling of B-25 Box

This project’s purpose is to determine the neutron multiplication factor (keff ) for the general handling of the B-25 Box in normal and credible abnormal conditions. This project is part of the container improvement effort at Y-12.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗