Search NASA⌕ Search

SEARCH · Search NASA

Results for “Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Active heat exchange system development for latent heat thermal energy storage

Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application (300 MW sub t storage for 6 hours). Two concepts were selected for hardware development: (1) a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and (2) a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which was nickel plated to decrease adhesion forces. In addition to improving performance by providing a nearly constant transfer rate during discharge, these active heat exchanger concepts were estimated to cost at least 25% less than the passive tube-shell design.

Alario, J.↗

Active heat exchange system development for latent heat thermal energy storage

Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion Phase Change Materials (PCM's) in the temperature range of 250 C to 350 C for solar and conventional power plant applications. Over 24 heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were chosen for small-scale experimentation: a coated tube and shell that exchanger, and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over fifty inorganic salt mixtures investigated. Preliminary experiments with various tube coatings indicated that a nickel or chrome plating of Teflon or Ryton coating had promise of being successful. An electroless nickel plating was selected for further testing. A series of tests with nickel-plated heat transfer tubes showed that the solidifying sodium nitrate adhered to the tubes and the experiment failed to meet the required discharge heat transfer rate of 10 kW(t). Testing of the reflux boiler is under way.

Lefrois, R. T.↗

The exchange of infrared radiative energy in the troposphere

On the basis of an atmospheric condition of a six-layer general circulation model of the National Center for Atmospheric Research, the spatial and the spectral partition of the long-wave radiation energy exchange in the model atmosphere is investigated and its implications are discussed. It is found that most of the energy is exchanged between adjacent layers and through the wings of strong lines. The strong line approximation is found to be a good approximation for water vapor transmittance. Cooling to space, however, is found to be a poor approximation for the total cooling rate. Both the strong line and cooling to space approximation are discussed in the content of the energy exchange findings.

Wu, M.-L. C.↗

Heat-Exchanger Method of Crystal Growth

Large crystals of silicon are grown from melt, in either vacuum or pressurized atmosphere, without moving crucible, furnace, or anything else. Seed crystal is mounted on helium-cooled heat exchanger, which prevents seed from melting when furnace melts rest of silicon material in crucible; heat exchanger draws off heat from melt so that a solid ingot grows outward from seed in a regular crystal structure. Bottom of crucible is insulated so that heat exchanger cools only seed.

Khattak, C. P.↗

Analysis of capacitive heat exchangers, part 1

Governing equations are developed for a simple capacitive heat exchanger. This type of heat exchanger consists of hot spherical particles falling through an ascending cold gas stream. The assumptions made in deriving the continuity, momentum and energy equations are clearly stated. The analysis yields a system of first order, ordinary, nonlinear equations which form a complex boundary value problem. The method of solution is presented together with a comparison between the performance of capacitive heat exchangers and conventional counter flow ones.

Schonfeld, D.↗

Transport, charge exchange and loss of energetic heavy ions in the earth's radiation belts - Applicability and limitations of theory

Computer simulations of processes which control the relative abundances of ions in the trapping regions of geospace are compared with observations from discriminating ion detectors. Energy losses due to Coulomb collisions between ions and exospheric neutrals are considered, along with charge exchange losses and internal charge exchanges. The time evolution of energetic ion fluxes of equatorially mirroring ions under radial diffusion is modelled to include geomagnetic and geoelectric fluctutations. Limits to the validity of diffusion transport theory are discussed, and the simulation is noted to contain provisions for six ionic charge states and the source effect on the radiation belt oxygen ion distributions. Comparisons are made with ion flux data gathered on Explorer 45 and ISEE-1 spacecraft and results indicate that internal charge exchanges cause the radiation belt ion charge state to be independent of source charge rate characteristics, and relative charge state distribution is independent of the radially diffusive transport rate below the charge state redistribution zone.

Spjeldvik, W. N.↗

The role of charge exchange in the solar wind absorption by Venus

The amount of solar wind absorbed because of charge exchange processes in the dayside ionosheath of Venus is calculated. The calculations suggest the existence of a lower limiting ionopause altitude, below which all solar wind particles are removed from the flow by charge exchange. The cold, slow ions resulting from this interaction are thought to play an important role in building the magnetic barrier observed just outside the ionopause and in creating the dayside 'mantle' and downstream 'penumbra' regions. The total absorption caused by charge exchange is typically 2-5%, although when the solar wind dynamic pressure is very high, it can reach 16%.

Gombosi, T. I.↗

A comparison of experimental and computer model results on the charge-exchange plasma flow from a 30 cm mercury ion thruster

Ion thrusters can be used in a variety of primary and auxiliary space-propulsion applications. A thruster produces a charge-exchange plasma which can interact with various systems on the spacecraft. The propagation of the charge-exchange plasma is crucial in determining the interaction of that plasma with the spacecraft. This paper compares experimental measurements with computer model predictions of the propagation of the charge-exchange plasma from a 30 cm mercury ion thruster. The plasma potentials, and ion densities, and directed energies are discussed. Good agreement is found in a region upstream of, and close to, the ion thruster optics. Outside of this region the agreement is reasonable in view of the modeling difficulties.

Gabriel, S. B.↗

Heat-Exchanger Computational Procedure For Temperature-Dependent Fouling

Computer program predicts heat-exchanger performance under variety of conditions. Program provides rapid means of calculating distribution of fluid and wall temperatures, fuel deposit formation, and pressure losses at various locations in heat exchanger. Developed for use with heat exchanger that vaporizes fuel prior to fuel ignition; other applications possible.

Chiappetta, L.↗

Inclusion of exact exchange in the noniterative partial-differential-equation method of electron-molecule scattering - Application to e-N2

The noniterative partial-differential-equation (PDE) approach to electron-molecule scattering of Onda and Temkin (1983) is modified to account for the effects of exchange explicitly. The exchange equation is reduced to a set of inhomogeneous equations containing no integral terms and solved noniteratively in a difference form; a method for propagating the solution to large values of r is described; the changes in the polarization potential of the original PDE method required by the inclusion of exact static exchange are indicated; and the results of computations for e-N2 scattering in the fixed-nuclei approximation are presented in tables and graphs and compared with previous calculations and experimental data. Better agreement is obtained using the modified PDE method.

Weatherford, C. A.↗

Criteria for scaling heat exchangers to miniature size

The purpose of this work is to highlight the particular aspects of miniature heat exchangers performance and to determine an appropriate design approach. A thermodynamic analysis is performed to express the generated entropy as a function of material and geometric characteristics of the heat exchangers. This expression is then used to size miniature heat exchangers.

Rudolfvonrohr, P. B.↗

Heat transfer and pressure drop performance of a finned-tube heat exchanger proposed for use in the NASA Lewis Altitude Wind Tunnel

A segment of the heat exchanger proposed for use in the NASA Lewis Altitude Wind Tunnel (AWT) facility has been tested under dry and icing conditions. The heat exchanger has the largest pressure drop of any component in the AWT loop. It is therefore critical that its performance be known at all conditions before the final design of the AWT is complete. The heat exchanger segment is tested in the NASA Lewis Icing Research Tunnel (IRT) in order to provide an icing cloud environment similar to what will be encountered in the AWT. Dry heat transfer and pressure drop data are obtained and compared to correlations available in the literature. The effects of icing sprays on heat transfer and pressure drop are also investigated.

Vanfossen, G. J.↗

Aeorodynamic characteristics of an air-exchanger system for the 40- by 80-foot wind tunnel at Ames Research Center

A 1/50-scale model of the 40- by 80-Foot Wind Tunnel at Ames Research Center was used to study various air-exchange configurations. System components were tested throughout a range of parameters, and approximate analytical relationships were derived to explain the observed characteristics. It is found that the efficiency of the air exchanger could be increased (1) by adding a shaped wall to smoothly turn the incoming air downstream, (2) by changing to a contoured door at the inlet to control the flow rate, and (3) by increasing the size of the exhaust opening. The static pressures inside the circuit then remain within the design limits at the higher tunnel speeds if the air-exchange rate is about 5% or more. Since the model is much smaller than the full-scale facility, it is not possible to completely duplicate the tunnel, and it will be necessary to measure such characteristics as flow rate and tunnel pressures during implementation of the remodeled facility. The aerodynamic loads estimated for the inlet door and for nearby walls are also presented.

Rossow, V. J.↗

Development of a prototype automated on-orbit contact heat exchanger

An automated contact heat exchanger is being developed for use aboard the manned Space Station, serving as an interface heat exchanger between the pressurized module internal thermal buses and the central external thermal bus. The concept makes use of an array of flattened, thin-walled, flexible tubes that expand or contract to make or break the thermal connection as the internal pressure changes. Because of its simplicity, it permits on-orbit assembly by the remote manipulator system, thus eliminating the need for expensive EVA to make connections. A design methodology based on stress and thermal analyses has been developed and used to perform trade-offs between performance and cost, and to optimize design parameters. Simple verification tests have been performed to confirm the stress analysis model. Two conceptual variants of the contact heat exchanger are described, each designed for a 25 kW total heat load and a minimum uniform heat flux of 2.15 W/sq cm.

Lee, C. Y.↗

Heat exchanger for electrothermal devices

An improved electrothermal device is disclosed. An electrothermal thruster utilizes a generally cylindrical heat exchanger chamber to convert electricity to heat which raises the propellant temperature. A textured, high emissivity heat element radiatively transfers heat to the inner wall of this chamber that is ion beam morphologically controlled for high absorptivity. This, in turn, raises the temperature of a porous heat exchanger material in an annular chamber surrounding the cylindrical chamber. Propellant gas flows through the annular chamber and is heated by the heat exchanger material.

Zavesky, Ralph J.↗

High heat transfer oxidizer heat exchanger design and analysis

The RL10-2B engine, a derivative of the RL10, is capable of multimode thrust operation. This engine operates at two low thrust levels: tank head idle (THI), which is approximately 1 to 2% of full thrust, and pumped idle (PI), which is 10% of full thrust. Operation at THI provides vehicle propellant settling thrust and efficient engine thermal conditioning; PI operation provides vehicle tank pre-pressurization and maneuver thrust for low-g deployment. Stable combustion of the RL10-2B engine during the low thrust operating modes can be accomplished by using a heat exchanger to supply gaseous oxygen to the propellant injector. The oxidizer heat exchanger (OHE) vaporizes the liquid oxygen using hydrogen as the energy source. The design, concept verification testing and analysis for such a heat exchanger is discussed. The design presented uses a high efficiency compact core to vaporize the oxygen, and in the self-contained unit, attenuates any pressure and flow oscillations which result from unstable boiling in the core. This approach is referred to as the high heat transfer design. An alternative approach which prevents unstable boiling of the oxygen by limiting the heat transfer is referred to as the low heat transfer design and is reported in Pratt & Whitney report FR-19135-2.

Kmiec, Thomas D.↗

The influence of charge exchange on the velocity distribution of hydrogen in the Venus exosphere

The simulation of the exosphere of Venus by a Monte Carlo technique has been extended to provide velocity distribution profiles that can be used with radiative transfer simulation to model the Lyman-alpha emission seen by spacecraft. The line profiles show a narrow core due to the exobase thermal source of hydrogen superimposed on the broad profile of hot hydrogen from charge exchange with hot ions in the nighttime ionosphere. Nightside radial profiles show long tails of upward flowing, escaping atoms. There are some downward and lateral superescape signatures, because the charge exchange source extends well above the exobase. At higher altitudes, flattening and even shallow central valleys appear in the transverse profiles. The planetary average escape rate due to charge exchange was found to be 2.8 x 10 to the 7th/sq cm per s, which is several times larger than escape rates for other candidate mechanisms.

Hodges, Richard R., Jr.↗

Oxidizer heat exchangers for rocket engine operation in idle modes

The heat exchanger concept is discussed together with its role in rocket engine operation in idle modes. Two heat exchanger designs (low and high heat transfer) utilizing different approaches to achieve stable oxygen vaporization are presented as well as their performance test results. It is concluded that compact and lightweight heat exchangers can be used in a stable manner under the 'idle' operating conditions expected with the RL10 rocket engine.

Kanic, P. G.↗