Search NASA⌕ Search

SEARCH · Search NASA

Results for “Explosion Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Tracing explosive in solvent using quantum cascade laser with pulsed electric discharge system

We demonstrated highly sensitive detection of explosive dissolved in solvent with a portable spectroscopy system (Q-MACS) by tracing the explosive byproduct, N{sub 2}O, in combination with a pulsed electric discharge system for safe explosive decomposition. Using Octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), the gas was monitored and analyzed by Q-MACS and the presence of the dissolved explosive clearly detected. While HMX presence could be identified directly in the air above the solutions even without plasma, much better results were achieved under the decomposition. The experiment results give an estimated detection limit of 10 ppb, which corresponds to a 15 pg of HMX.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and implementation of an underwater sound recording device

To monitor the underwater sound and pressure waves generated by activities such as underwater blasting and pile driving, an autonomous system used to record underwater acoustic signals was designed. The device designed allows two hydrophones or other dynamic pressure sensors to be connected, filters out high frequency noise, has a gain that can be independently set for each sensor, and allows two hours of data to be collected. Two versions of the USR were created; one is submersible to a maximum depth of 300 m, and the other, although watertight, is not intended to be fully submersed. Tests were performed in the laboratory using a data acquisition system to send single-frequency sinusoidal voltages directly to the each component. These tests verified that the device performs as well as larger commercially available data acquisition systems, which are not suited for field use. A prototype of the device was used in a case study to investigate the effect of underwater rock blasting on juvenile Chinook salmon and rainbow trout. The case study demonstrated that the device was able to tolerate being operated in harsh environments, making it a valuable tool for collecting field measurements.

47 OTHER INSTRUMENTATION↗

Measurements of the Dielectric Properties of Thin High-Explosive Samples Using a Parallel Plate Test Fixture

This report presents results of a study of the dielectric properties of several high explosive materials, including Composition B, C-4, Detasheet, Semtex 1A, Semtex 1H, and Semtex 10. The capacitance and dispersion of samples up to ten mm thick were measured at 24 and 65°C using a parallel plate test fixture. In this configuration, capacitance is proportional to the real component of the complex dielectric constant (or permittivity) of the material, while the dispersion is equal to the imaginary component of the dielectric constant divided by the real component. Measurements were performed at two temperatures to determine whether these dielectric properties might be used to monitor moderate temperature changes within these materials using an external fringing field capacitor. It was found that the real dielectric constant of the high explosives generally changed by only about 1% on heating from 24 to 65°C, and that the externally measured capacitance is therefore not a reliable parameter for monitoring temperature changes in these explosives. Temperature- based changes in the dispersion were often 20% or greater, and for several materials (e.g., Composition B, Detasheet) the temperature and dispersion showed good correlation as the temperature of the explosive was cycled up and down. It is thus possible that for some high explosives the externally measured dispersion is a useful parameter for monitoring temperature changes. However, other factors may limit the usefulness of this technique, including the need to have the plates of a fringing field capacitor in direct contact with the high explosive to obtain measurements, and the limited penetration depth of the fringing field into the explosive material.

36 MATERIALS SCIENCE↗

The 2014 Integrated Field Exercise of the Comprehensive Nuclear-Test-Ban Treaty revisited: The case for data fusion

The International Monitoring System of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO) uses a global network of radionuclide monitoring stations to detect evidence of a nuclear explosion. The two radionuclide technologies employed—particulate and noble gas (radioxenon) detection—have applications for data fusion to improve detection of a nuclear explosion. Using the hypothetical 0.5 kT nuclear explosive test scenario of the CTBTO 2014 Integrated Field Exercise, the intrinsic relationship between particulate and noble gas signatures has been examined. Here this study shows that, depending upon the time of the radioxenon release, the particulate progeny can produce the more detectable signature. Thus, as both particulate and noble gas signatures are inherently coupled, the authors recommend that the sample categorization schemes should be linked.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Muon trackers for imaging a nuclear reactor

A detector system for assessing damage to the cores of the Fukushima Daiichi nuclear reactors by using cosmic-ray muon tomography was developed. Furthermore, the system consists of a pair of drift-tube tracking detectors of 7.2× 7.2-m 2 area. In each muon tracker there consists 6 x-layer and 6 y-layer drift-tube detectors. Each tracker is capable of measuring muon tracks with 12 mrad angular resolutions, and is capable of operating under 50-μ Sv/h radiation environment by removing gamma induced background with a novel time-coincidence logic. An estimated resolution to observe nuclear fuel debris at Fukushima Daiichi is 0.3 m when the core is imaged from outside the reactor building.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Direct Injection/Ionization Mass Spectrometry Methods for Whole Molecule Characterization

The objective of this work is to adapt ambient ionization mass spectrometry (AMS) techniques for the rapid analysis of intact uranium complexes, stable strontium, cerium, and explosive compounds. The methods used were “soft ionization” techniques, which facilitate the detection of whole molecule complexes. The soft ionization mass spectrometry (MS) techniques that were investigated include paper spray ionization (PSI), matrix-assisted ionization (MAI), electrospray ionization (ESI) and direct analysis in real time (DART). For the first time, PSI-MS methods were successfully developed for whole molecule uranium-containing analytes (uranyl acetate, uranyl nitrate, and uranyl-tributylphosphate complexes). This was also the first demonstration of uranium complex detection and characterization and one of the few examples of inorganic analysis using MAI techniques. Proof of concept experiments also putatively identified matrix-derived ions and ion complexes that have not previously been described in the literature. Additionally, PSI-MS on cotton swipe samples doped with a multi-element standard containing μg levels of U, Bi, Pb, Cd, Fe, and Zn were directly analyzed without purification, representing a major improvement over existing methods. Both PSI and MAI methods demonstrated limits of detection (LODs) in the 10 - 100’s ng for various uranyl species within a range of 10’s ppm - 100’s ppb, dependent on analytical method and analyte species. AMS methods were also developed for other inorganics, including Ce and Sr, and organic explosive residues to address specific challenges in environmental monitoring and forensics. Further refinement and qualification of the AMS techniques developed within this effort would lead to significant cost reduction and timeliness by facilitating the triage and queueing of samples for subsequent more sensitive and time-consuming analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonproliferation and Arms Control Research and Development (NPAC R&D) [Slides]

NPAC R&D focus areas include: Advancing U.S. capabilities to detect and characterize nuclear weapon development activities globally, including material production, the movement of special nuclear materials and nuclear weapons, and the testing or use of nuclear weapons, Supporting the development and testing of policy options and technical capabilities for international nuclear safeguards, arms control / treaty verification, nuclear export controls, and nonproliferation initiatives consistent with U.S. Government goals and objectives to enable monitoring and verification, Utilizing uranium, lithium, and high explosives (HE) materials expertise to support national-level activities in nuclear forensics and nuclear detection technology testing and evaluation, Providing unique training and capacity-building programs, particularly with the Nuclear Detection and Sensor Testing Center (NDSTC), and Engaging internationally to promote nonproliferation and arms control norms and best practices through bilateral and multilateral work.

36 MATERIALS SCIENCE↗

Interference Terms for Xenon-135

Systems to measure radioxenon concentrations are continually being improved to provide greater sensitivity and precision. As the systems become more capable, additional terms need to be added to the calculations to account for small previously insignificant effects such as minor decay branches. Recently, additional terms present in the {sup 135}Xe decay were added to the calculations to account for the small (5.2%) fraction of decays that produce cesium K-shell x-rays with an average energy of 32 keV and the Compton scatter of the dominant 250-keV gamma ray. These events overlap with the regions of interest of {sup 133}Xe, {sup 131m}Xe, and {sup 133m}Xe. In typical field applications, the amount of expected {sup 135}Xe is low due to the short half-life (9.14 hours) therefore the small fraction that could be mis-categorized as other isotopes is insignificant in most cases. However, for much more active samples, such as those recently measured in calibration and testing samples with high activity, the amount of mis-categorization can be significant. The additions to the calculations use calibration values to estimate the amount of a possible interference of {sup 135}Xe in the other regions of interest, which are then subtracted out. The calibration values, which are ratios of counts in one region of interest to another, are obtained by measuring with single isotope gases during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the individual channel correlation traces to achieve significant array gain. In previous years we have characterized the decrease in detection threshold afforded by correlation detection across an array or network when observations of a previous event provide an adequate template for signals from subsequent events located near the calibration event. Last year we examined two related issues: (1) the size of the source region calibration footprint afforded by a master event, and (2) the use of temporally incoherent detectors designed to detect the gross envelope structure of the signal to extend the footprint. In Case 1, results from the PETROBAR-1 marine refraction profile indicated that array correlation gain was usable at inter-source separations out to one or two wavelengths. In Case 2, we found that incoherent detectors developed from a magnitude 6 event near Svalbard were successful at detecting aftershocks where correlation detectors derived from individual aftershocks were not. Incoherent detectors might provide 'seed' events for correlation detectors that then could extend detection to lower magnitudes. This year we addressed a problem long known to limit the acceptance of correlation detectors in practice: the labor intensive development of templates. For example, existing design methods cannot keep pace with rapidly unfolding aftershock sequences. We successfully built and tested an object-oriented framework (as described in our 2005 proposal) for autonomous calibration of waveform correlation detectors for an array. The framework contains a dynamic list of detectors of several types operating on a continuous array data stream. The list has permanent detectors: beam forming power (STA/LTA) detectors which serve the purpose of detecting signals not yet characterized with a waveform template. The framework also contains an arbitrary number of subspace detectors which are launched automatically using the waveforms from validated power detections as templates. The implementation is very efficient such that the computational cost of adding subspace detectors was low. The framework contains a supervisor that oversees the validation of power detections, and periodically halts the processing to revise the portfolio of detectors. The process of revision consists of collecting the waveforms from all detections, performing cross-correlations pairwise among all waveforms, clustering the detections using correlations as a distance measure, then creating a new subspace detector from each cluster. The collection of new subspace detectors replaces the existing portfolio and processing of the data stream resumes. This elaborate scheme was implemented to prevent proliferation of closely-related subspace detectors. The method performed very well on several simple sequences: 2005 'drumbeat' events observed locally at Mt. St. Helens, and the 2003 Orinda, CA aftershock sequence. Our principal test entailed detection of the aftershocks of the San Simeon earthquake using the NVAR array; in this case, the system automatically detected and categorized approximately 2/3 of the events above magnitude 2.8.

58 GEOSCIENCES↗

Incident Involving 30-Ah Li-ion Cell at NASA Glenn Research Center

The key lesson learned from the February 17, 2006 cell explosion incident is that PC-based test-systems, even those having built-in watchdog monitors, can lose control and malfunction. In the case of lithiumion cell/battery testing, the stored energy can be released explosively causing considerable injury and damage to facilities. The investigation showed that although the Arbin system has a built-in watchdog monitor, the circumstances of the incident defeated the action of the watchdog and allowed the cycler to continue operation without control. An upgrade to the most recent version of Arbin software (version 4) was provided as a fix to the presumed control problem. This upgrade included newer EPROM s for the cycler microprocessor. Investigation revealed that similar incidents have occurred at other NASA centers with a variety of PC-based test instruments. JPL suffered an incident with Maccor testers and the GRC fuel cell group observed similar problems with LabView software. This is not exclusively an Arbin problem, but an issue with all PC-based systems. In this incident, it was fortunate that the event occurred after-hours with no-one in the room. The facility arrangement placed control consoles adjacent to the test chamber doors. Had someone been in the room during the event, they would have been exposed to hot debris and toxic combustion products. It was also fortunate that the exploded cell stayed inside the chamber after the door was forced open. If the cell had been ejected into the room it could have caused serious facility damage by impact and possibly caused a fire in the facility.

Bennett, William↗

Infrasound signatures from buried chemical explosions during the SPE Phase 1

Strong ground motion induces acoustic waves in the atmosphere that can be detected at great distances. These waves provide a record of acceleration at the epicenter of the subterranean event. While this information is valuable for nuclear monitoring purposes, a systematic study of the variation in acoustic parameters with explosive yield and depth has not yet been conducted. Here, we provide a survey of low frequency sound waves generated during the Source Physics Phase 1 experiment, in which six chemical explosions were detonated in granite. We found that pressure amplitudes increase with explosion size but decrease with depth as expected. Pressure amplitude variability increased with signal magnitude. Surprisingly, peak frequency appears to increase with depth. A possible directional signal was identified for one of the events as well. The results presented here may aid the nuclear monitoring community in developing means of determining event depth and yield using acoustic methods. This will complement existing algorithms based on seismic radiation.

58 GEOSCIENCES↗

Swift Observations of Supernovae during and after Shock Breakout

Over the past few years, space-based observatories have allowed detailed studies of energetic supernova explosions in previously unexplored time domains and wavelength regimes. NASA's Swift observatory is playing an important role in probing the early emission of SNe during and after shock breakout due to its fast response, flexible scheduling capabilities, and large wavelength band coverage, ranging from the optical, W, and X-ray to the Gamma-ray bands. By studying the outgoing SN shocks with material in its surroundings, the explosion physics and nature of progenitor stars can be studied. Furthermore, monitoring the X-ray emission of SNe with space-based X-ray observatories is being used to map the density structure in SN environments out to large radii from the sites of the explosions (>E20 cm), the transition of a SN into an old supernova remnant can be studied, and the mass-loss rates of the progenitor stars are being probed over significant timescales (>E4 years) in the stellar wind history. In combination, these observations give unprecedented insights into the nature of energetic explosions and their environments. During this talk, I will present highlights from recent observations, among them the first observation of a SN DURING the actual explosion with Swift, and I will discuss the "naked eye" burst at a redshift of -1, which was the most distant object humans could ever see with their own eyes.

Immler, Stefan↗

Simulating High-Frequency Seismograms in Realistic Earth Models to Better Understand Source Discrimination Based on Differential Magnitudes ( M L− M c)

Discriminating low-yield underground nuclear explosions from small earthquakes is a key task in monitoring nuclear test ban treaties. P/S amplitude ratios have been an effective discriminant for moderate-sized events recorded at regional distances, but it is unclear if they are as effective in discriminating small seismic events recorded at local distances (<150 km). The difference between local magnitude (M L ) and coda duration magnitude (M c ) has been proposed as a new discriminant that may complement P/S amplitude ratios at local distances. Here, in this work, we calculate high-frequency (up to ∼4 Hz) synthetic seismograms at epicentral distances of 0–30 km in realistic models of the Salt Lake basin (Utah, United States) to better understand how variations in source type and depth affect M L −M c values. The Earth models incorporate simplified 1D and deterministic 3D structures, small-wavelength stochastic velocity perturbations, and surface topography. Coda waves are enhanced for the more complicated models compared to the base 1D model, but still underpredict observed durations by about a factor of two, which results in overprediction of amplitude to duration ratios (i.e., M L −M c values) for a near-surface explosion and a 7 km deep earthquake. For both source types, the predicted M L and M c values decrease as source depth increases, and M L −M c shows only minor variation with depth; however, M L −M c is on average ∼0.5 units smaller for explosions than earthquakes. This finding may imply that M L −M c has sensitivity to source type, in addition to being a depth discriminant, but more modeling is needed given the limitations of the current study. Future modeling should incorporate higher-frequency (≳5 Hz) simulations over a larger distance range (0–150 km), where M L and M c are commonly measured, while honoring low shear velocities (<300 m/s) near the surface and sampling a wider range of earthquake and explosion source mechanisms.

Hutchings, Sean J. [Univ. of Utah, Salt Lake City,↗

Waterhole auroral arc modification experiments Electrodynamic response

The Waterhole series of experiments, which tested current theories of the electrodynamic structure of auroral arcs, is discussed. In these experiments, the current-carrying capability of the ionospheric plasma was modified by the explosive release of a large number of reactive molecules in the ionospheric F region, with the net effect of reducing the local plasma density over spatial scales comparable to the auroral forms. The response of the aurora to this perturbation was monitored directly by plasma diagnostic instruments on the rocket carrying the explosive release and indirectly from the ground by various photometric and imaging devices. Model predictions of the perturbation induced by the two releases are summarized, and the rocket-borne and ground-based instrumentation is described. Results from both flights are summarized, and a theoretical model is presented which relates the differences in observed response to the topological relationship between the releases and the auroral form.

Whalen, B. A.↗

Floodplain statement of findings for corrective actions in Potrillo Canyon technical area-36, Los Alamos National Laboratory, Los Alamos, New Mexico

In 2014, baseline storm water monitoring samples for Potrillo Canyon Sample Management Area at Los Alamos National Laboratory (LANL) exceeded the National Pollutant Discharge Elimination System Individual Permit No. NM0030759 target action level (TAL) of 15 picocuries per liter (pCi/L) for gross-alpha radioactivity (393 pCi/L) and a TAL of 30 pCi/L for radium-226 and radium-228 (95.9 pCi/L). Consequently, erosion control measures within the management area are proposed to minimize sediment migration, a corrective action under the permit that is a requirement of the New Mexico Environment Department consent decree and a good management practice to limit off-site sediment migration. The area proposed for erosion controls consists of portions of Technical Area 36 that were used as firing sites primarily involving high explosives (HE) and metal (e.g., depleted uranium, lead, copper, aluminum, and steel), small-explosives experiments and burn pits (burn pits were used for burning and disposal of test debris). In addition, underground explosive tests at an approximate depth of 100 feet were also conducted. These watershed-based storm water controls will focus on addressing erosion occurring within the floodplain through mitigating and reducing both current and future channelization and head cutting.

54 ENVIRONMENTAL SCIENCES↗

Abatement of Xenon and Iodine Emissions from Medical Isotope Production Facilities

The capability of the International Monitoring System (IMS) to detect xenon from underground nuclear explosions is dependent on the radioactive xenon background. Adding to the background, medical isotope production (MIP) by fission releases several important xenon isotopes including xenon-133 and iodine-133 that decays to xenon-133. The amount of xenon released from these facilities may be equivalent to or exceed that released from an underground nuclear explosion. Thus the release of gaseous fission products within days of irradiation makes it difficult to distinguish MIP emissions from a nuclear explosion. In addition, recent shortages in molybdenum-99 have created interest and investment opportunities to design and build new MIP facilities in the United States and throughout the world. Due to the potential increase in the number of MIP facilities, a discussion of abatement technologies provides insight into how the problem of emission control from MIP facilities can be tackled. A review of practices is provided to delineate methods useful for abatement of medical isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Current status of the Explosive Transient Camera

The current configuration and performance of the Explosive Transient Camera (ETC), a wide-field sky monitor capable of detecting short-timescale optical transients, are briefly reviewed, as are plans for future improvements. The primary objective of the ETC is to detect an optical transient that is spatially and temporally coincident with a gamma-ray burster. However, the ETC is sensitive to all sources of short-timescale optical transients and will conduct a systematic survey of the night sky for all optical transients. Results of preliminary observations of the night sky conducted since January 1991 are summarized, and long-term variability searches with the ETC are discussed.

Vanderspek, Roland↗

Miniature Reversal Electron-Attachment Detector

Miniature reversal electron-attachment detector (miniREAD) enables direct injection of air or vapor at atmospheric pressure from monitored area into mass-spectrometric instrument to detect explosives, narcotics, or other substances, vapors of which suspected of being present in low concentrations. In comparison with older reversal electron-attachment detector, miniREAD simpler in design; more rugged; and easier to build, repair, and maintain. In addition, probably more sensitive.

Chutjian, Ara↗